RenewAire HE 1.5XIN Energy Recovery Ventilator

Indoor Unit

Specifications & Dimensions

Energy recovery core is AHRI Certified® ✔️

Model HE1.5XINH shown.

Certifications: ETL LISTED ⚡

General Specifications

Ventilation TypeStatic plate, heat and humidity transfer
Airflow Range375-1,650 CFM
AHRI 1060 Certified CoreOne L62-G5 and one L125-G5
Standard FeaturesNon-fused disconnect, 24VAC transformer/relay package, Cross-core differential pressure ports
FiltersTotal Qty. 4, MERV 8: (2) 14" x 20" x 2" and (2) 16" x 20" x 2"
Unit Weight337-504 lbs., varies by option(s)
Max. Shipping Dimensions & Weight (on pallet)H: 70" L x 47" W x 53" H (571 lbs.), V: 70" L x 47" W x 59" H (71 lbs.)
Motor(s)Qty. 2, 1.0 HP ea., Direct drive standard motorized impellers

Available Options

Accessories

Airflow Performance

External Static Pressure (Inches Water Column)

Blower RPM 0.00 0.25 0.50 0.75 1.00 1.25 1.50
SCFMWattsSCFMWattsSCFMWattsSCFMWattsSCFMWattsSCFMWattsSCFMWatts
147515751545147015251570140013501435150013801225147510901435
1475950138094012107951300

Operation in this zone outside of core airflow limits.

Note: Watts is for the entire unit (2 motors). Airflow performance includes effect of clean, standard filter supplied with unit.

Electrical Data

Watts Volts Hz Phase FLA per motor Min. Cir. Amps Max. Overcurrent Protection Device
112060Single6.514.620
1208-23060Single3.3-3.47.715
127760Single2.76.115
1208-23060Three2.2-2.25.015
146060Three1.132.515

Augmented Reality (AR)

Scan QR code to see life size version of HE1.5X, or view here: https://ar.marketscale.com/renewaire/he

[QR Code Placeholder: Scan for Augmented Reality view]

Unit Mounting & Application

Can be mounted in any orientation. RA/EA airstream can be switched with OA/FA airstream unless certain options are selected. Duct configuration is field convertible.

Installation Orientation: Unit may be installed in any orientation.

Notes:

Dimensional Views & Airflow Configuration

The following describes the unit's dimensions and airflow paths. Specific models mentioned include HE1.5XINH and HE1.5XINV.

Top View

Depicts the unit's top profile. Key features include: overall dimensions (e.g., HE1.5XINH: 48 3/4" Overall width, 32" Case width, 42 5/8" Case depth; HE1.5XINV: 46 1/4" Overall width, 49 5/8" Case width, 32 5/8" Case depth), patch pan (opening used for alternative unit configurations), door swing, and duct receiving flanges (18" x 18" Typ.).

Front View

Shows the front of the unit. Features include: overall dimensions (e.g., HE1.5XINH: 52 3/4" Case height, 48 3/4" Overall width; HE1.5XINV: 59 1/2" Overall height with Damper Frames), pressure ports (4) Typ., door-interlocked disconnect switch, damper frames (5" Typ.), and duct receiving flanges (18" x 18" Typ.). Airflow paths are indicated: OA (Outside Air), RA (Room Air), FA (Fresh Air), EA (Exhaust Air).

Left View

Illustrates the left side of the unit. Features include: case dimensions (e.g., HE1.5XINH: 53 5/8" Overall height, 52 3/4" Case height; HE1.5XINV: 45 3/4" Case height), duct receiving flanges (18" x 18" Typ.), power wiring inlet (7/8" dia.), control wiring inlet (7/8" dia.), and damper locations (FA Damper Location - Optional, EA Damper Location - Optional).

Right View

Presents the right side of the unit. Features include: overall dimensions, minimum service area (20 1/8"), case dimensions, door swing, and duct receiving flanges (18" x 18" Typ.).

Airflow Configuration

Available as shown in dimension drawings. The unit supports various airflow configurations, typically involving Outside Air (OA), Exhaust Air (EA), Room Air (RA), and Fresh Air (FA).

Bypass Economizer Options

Models with bypass economizers (e.g., HE1.5XINV) include additional features and considerations.

Bypass Airflow Schematic (Top View)

Illustrates the bypass airflow. Key components shown are: 12" Bypass Duct Connection (Direct Mount to Damper, By Others), Face Damper, Bypass Damper, and air streams: RA, EA, FA, BP (Bypass Air outlet). The schematic indicates that OA/FA airstream is not shown in this specific diagram.

Bypass Unit Notes:

Unit Mounting & Application (Bypass): Can be mounted in any orientation. Airstreams cannot be switched.

PDF preview unavailable. Download the PDF instead.

Submittal-HE15XIN-June2024 Adobe PDF Library 17.0

Related Documents

Preview RenewAire EV 130 Energy Recovery Ventilator Specifications and Dimensions
Explore the technical specifications, performance data, and dimensions for the RenewAire EV 130 Energy Recovery Ventilator. This HVI-certified unit is ideal for residential and light commercial HVAC systems, offering efficient air exchange and energy recovery.
Preview RenewAire EV 200 Energy Recovery Ventilator: Specifications & Dimensions
Technical specifications, performance data, and dimensional details for the RenewAire EV 200 Energy Recovery Ventilator (ERV), an indoor unit designed for residential and light commercial applications.
Preview Ventilateurs à Récupération d'Énergie Série HE RenewAire
Découvrez les ventilateurs à récupération d'énergie (ERV) de la série HE de RenewAire, conçus pour améliorer la qualité de l'air intérieur (QAI), réduire les coûts énergétiques et favoriser des environnements sains et productifs dans les bâtiments commerciaux. Ces unités offrent une récupération totale d'énergie, des moteurs à haut rendement, et une conception flexible pour diverses applications.
Preview RenewAire Engineered Combo Curbs: HVAC Integration Solution
Discover RenewAire Engineered Combo Curbs, a solution for seamlessly integrating Master Rooftop Units (RTUs) with RenewAire Energy Recovery Ventilators (ERVs). This guide details benefits, applications, specifications, and construction for efficient HVAC system design.
Preview RenewAire CA-3XIN Air-to-Air Energy Recovery Ventilator Specifications
Comprehensive CSI specifications for the RenewAire CA-3XIN ERV, detailing product features, quality assurance, installation, and execution requirements for HVAC systems.
Preview RenewAire CA-2XIN ERV: Air-to-Air Energy Recovery Ventilator Specification Guide
Detailed CSI specification guide for the RenewAire CA-2XIN Air-to-Air Energy Recovery Ventilator (ERV). Covers general requirements, product specifications, quality assurance, submittals, and execution for indoor or outdoor installation, adhering to industry standards like AHRI 1060 and UL 723.
Preview RenewAire Enhanced Commercial Controls Installation, Operation, and Maintenance Manual
This manual provides comprehensive instructions for the installation, operation, and maintenance of RenewAire's Enhanced Commercial Controls for HE1.5-8X and LE-Series ERV units. It covers control sequences, system overview, sensor information, configuration, troubleshooting, and advanced service procedures.
Preview RenewAire ERVs: Maximize Financial Performance and Energy Savings
Discover how RenewAire Energy Recovery Ventilators (ERVs) deliver significant long-term value through enhanced indoor air quality (IAQ) and substantial energy savings, featuring detailed Net Present Value (NPV) and Internal Rate of Return (IRR) calculations for the HE2XINH model.