PAL Lighting PCR-3DMX-8Z Controller Instructions
Dimensions
The enclosure features 6 conduit holes. Remove the cap to utilize a conduit hole and leave unused conduits capped. The center front hole is designated for the power cable.
There are 13/16" / 21.0mm knockouts for connecting the power supply. There are 4 available on the right side of the enclosure and 3 available on the left. One knockout on the left is used for the air valve.
Knockout Instructions
It is recommended that the cover is fitted and the cover screws are tight when removing the knockouts. To remove a knockout, place a flat blade screwdriver with a 3/16" (4mm) blade as shown in the diagram. A light hit with a hammer on the head of the screwdriver will allow the knockout to be removed.
Alternatively, drill location points are located in the center of each knockout, allowing the use of a hole saw to remove them.
INSTALLATION & MAINTENANCE INSTRUCTIONS ON THE 16/35/65 WATT PCR-3DMX CLASS 2 OUTDOOR DRIVER/RECEIVER FOR 12V D/C PAL 4 WIRE LED LIGHTS
Features
- Easy to Install
- UL Listed Class 2 Power Supply / Swimming Pool and Spa Transformer (WDGV)
- IP65 Wet Location Construction
- Constant 24V DC Output Voltage over the Supply
- 3 Year Warranty Period
Important Information
This PCR-3DMX Class 2 power supply is specifically designed to supply 24V DC to power the PAL 4 Wire UL Listed LED Pool lights. The PCR-3DMX must be installed in accordance with the National Electrical Code by a Certified Electrician or Qualified Pool Technician.
Note: No bonding is required from this Class 2 power supply to the UL Listed PAL Pool Light fixtures as they are made of an all plastic construction and comply with NEC article 680 requirements.
INSTALLATION INSTRUCTIONS FOR PCR-2MX RGB OUTDOOR DRIVER
Step 1. Mounting the Driver
The 8Z DMX Driver is a Class 2 Power Supply with Weatherproof construction (IP65). It should be mounted on a flat surface using the mounting legs on the enclosure with appropriate fixtures for the mounting substrate. Position it suitably for the intended location of the PAL 4 Wire LED Pool Lights and install to comply with all requirements of the National Electrical Code (NEC) and relevant local codes and ordinances.
Note: The Driver Enclosure must be located a minimum distance of 5 feet measured horizontally from the inside wall of the pool and not less than 1 foot above the maximum pool water level measured to the top of the Driver Enclosure.
Note: The enclosure must be mounted using the mounting legs on the enclosure with the supplied screw set. If mounting on a concrete or block wall, mark the mounting hole locations, drill 3/16” holes using a masonry drill, fit the supplied Star Plugs into the holes, and secure with the supplied stainless steel screws.
Step 2. Connecting Power Supply
Using the front left entry, connect the 100-240V power supply according to NEC code requirements. Note: BLUE IS NEGATIVE (NEUTRAL) and BROWN IS POSITIVE (HOT).
Step 3. Connecting LED Lights
Using the remaining conduit entries at the bottom of the 8Zone DMX, connect the 4-core wire from the PAL 4 WIRE LED LIGHTS. Ensure the 4 cores are connected to the correct terminals.
INSTALLATION INSTRUCTIONS FOR PCR-3DMX RGB OUTDOOR DRIVER
Notes:
- If using twist-on wire connectors, ensure the wires are not pulled out from the JST (White) Clip in the back. Tightening wire connectors with excessive tension on the PAL wires can cause them to pull out from the clip, resulting in a poor connection.
- The driver can only be tested with a DMX signal present.
- All dipswitches (SW 6, SW 7, SW 9, SW 5) should be in the vertical orientation (OFF position).
PCR DMX Operation
The DMX input module allows remote DMX control over the two zone outputs in the PCR 2Z.
Installation
Note: It is recommended to use shielded DMX wire/cable or shielded twisted-pair cable (e.g., CAT5e or 6 cable).
- Connect DMX input to the “IN” screw terminal block, with connections as indicated on the PCB.
- Connect DMX loop to the “THRU” screw terminal block.
- If no loop out is used, place the supplied shunt across the “TERM” pins.
- Set the DMX address as per the table on the following page.
Operation
Signal LED
When in DMX mode, the “CPU” LED on the PCB functions as a DMX signal indicator. This LED illuminates during a DMX packet, and its flash rate depends on the DMX controller used. At high refresh rates, the signal LED may appear to be constantly lit.
The Signal LED is located at the first VERTICAL DIP SWITCH (SW 6), positioned below the Ethernet port and to the left of the fuses. Refer to the diagram for its location.
The next three LEDs along the VERTICAL dip switches (SW 6, SW 7, SW 9, and SW 5) should be illuminated when the driver has power.
Loss of DMX
The output levels are maintained for 60 seconds after the DMX signal is lost, after which the output is turned off. After an additional 60 seconds of no DMX signal, the fan will turn off.
Other
The software includes temperature limiting. If the temperature exceeds approximately 60°C, the output levels are reduced. The PCR DMX input does not support RDM.
If using only one driver for DMX, only the far-right HORIZONTAL dip switch (SW 1) should be in the “ON” position, signifying the starting channel is 1.
If using multiple drivers, each 8 Zone driver has a total of 24 channels. For example, if you have one 8 zone driver and one 2 zone driver, your 8 zone driver will handle channels 1-24, and your 2 zone driver will start on channel 25. Follow the Dipswitch chart provided.
Starting Channel Table
DIP SWITCH | ||||||||||||
SW9 | SW8 | SW7 | SW6 | SW5 | SW4 | SW3 | SW2 | SW1 | ||||
Verify These |
VALUE | 256 | 128 | 64 | 32 | 16 | 8 | 4 | 2 | 1 | ||
8 Zone Driver # |
STARTING CHANNEL |
STARTING CHANNEL |
OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | ON | |
1 | 1 | 1 | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | ON | |
2 | 25 | 25 | OFF | OFF | OFF | OFF | ON | ON | OFF | OFF | ON | |
3 | 49 | 49 | OFF | OFF | OFF | ON | ON | OFF | OFF | OFF | ON | |
4 | 73 | 73 | OFF | OFF | ON | OFF | OFF | ON | OFF | OFF | ON | |
5 | 97 | 100 | OFF | OFF | ON | ON | OFF | OFF | ON | OFF | OFF | |
6 | 121 | 124 | OFF | OFF | ON | ON | ON | ON | ON | OFF | OFF | |
7 | 145 | 148 | OFF | ON | OFF | OFF | ON | OFF | ON | OFF | OFF | |
8 | 169 | 172 | OFF | ON | OFF | ON | OFF | ON | ON | OFF | OFF | |
9 | 193 | 196 | OFF | ON | ON | OFF | OFF | OFF | ON | OFF | OFF | |
10 | 217 | 220 | OFF | ON | ON | OFF | ON | ON | ON | OFF | OFF | |
11 | 241 | 244 | OFF | ON | ON | ON | ON | OFF | ON | OFF | OFF | |
12 | 265 | 268 | ON | OFF | OFF | OFF | OFF | ON | ON | OFF | OFF | |
13 | 289 | 292 | ON | OFF | OFF | ON | OFF | OFF | ON | OFF | OFF | |
14 | 313 | 316 | ON | OFF | OFF | ON | ON | ON | ON | OFF | OFF | |
15 | 337 | 340 | ON | OFF | ON | OFF | ON | OFF | ON | OFF | OFF | |
16 | 361 | 364 | ON | OFF | ON | ON | OFF | ON | ON | OFF | OFF | |
17 | 385 | 388 | ON | ON | OFF | OFF | OFF | OFF | ON | OFF | OFF | |
18 | 409 | 412 | ON | ON | OFF | OFF | ON | ON | ON | OFF | OFF | |
19 | 433 | 436 | ON | ON | OFF | ON | ON | OFF | ON | OFF | OFF | |
20 | 457 | 460 | ON | ON | ON | OFF | OFF | ON | ON | OFF | OFF | |
21 | 481 | 484 | ON | ON | ON | ON | OFF | OFF | ON | OFF | OFF | |
22 | 505 | 508 | ON | ON | ON | ON | ON | ON | ON | OFF | OFF |
8 Zone Channel Allocations
ZONE 1 | ZONE 2 | ZONE 3 | ZONE 4 | ||||||||
CH1 | CH2 | CH3 | CH4 | CH5 | CH6 | CH7 | CH8 | CH9 | CH10 | CH11 | CH12 |
RED | GREEN | BLUE | RED | GREEN | BLUE | RED | GREEN | BLUE | RED | GREEN | BLUE |
ZONE 5 | ZONE 6 | ZONE 7 | ZONE 8 | ||||||||
CH13 | CH14 | CH15 | CH16 | CH17 | CH18 | CH19 | CH20 | CH21 | CH22 | CH23 | CH24 |
RED | GREEN | BLUE | RED | GREEN | BLUE | RED | GREEN | BLUE | RED | GREEN | BLUE |
Troubleshooting 8 Zone Driver
No Power?
Ensure your 120v power supply has a good connection to the Blue and Brown Wires. Brown should be connected on the TOP of the JST Clip (located behind the PCB board on the left), and Blue on the bottom.
No DMX Signal
- Check and ensure connections VIA the Green BUS terminals.
- Ensure the same wires are connected in the same spots. For example, BLUE is positive on the driver, and blue is positive on the DMX transmitter.
- Ensure the DMX transmitter has power.
- Ensure the DMX controller is programmed for the proper channels.
DMX Signal but no lights
- Ensure your starting channel in your DMX controller is correct.
- Ensure dipswitches match the required configuration.
Colors are incorrect
Check the coding in the DMX controller and ensure no numbers were skipped in the programming of the Driver.
8 Zone Programming channels for DMX controller (For Single 8 zone driver)
- Zone 1: Red 1 Green 2 Blue 3
- Zone 2: Red 4 Green 5 Blue 6
- Zone 3: Red 7 Green 8 Blue 9
- Zone 4: Red 10 Green 11 Blue 12
- Zone 5: Red 13 Green 14 Blue 15
- Zone 6: Red 16 Green 17 Blue 18
- Zone 7: Red 19 Green 20 Blue 21
- Zone 8: Red 22 Green 23 Blue 24