Pro'sKit MT-1210 Digital Multimeter

Model: MT-1210

DC500V10A-AC500V-2MOHM-HOLD+TR

Safety Information

This multimeter is designed according to IEC 1010 concerning electronic measuring instruments with an overvoltage category (CAT II) and pollution 2. Follow all safety and operating instructions to ensure the meter is used safely and kept in good operating condition. Full compliance with safety standards is guaranteed only with supplied test leads. If necessary, they must be replaced with the type specified in this manual.

Safety Symbols

Maintenance

During Use

General Description

The meter is a handheld 3 1/2 digital multimeter for measuring DC and AC voltage, DC current, Resistance, Diode, Transistor, and Continuity Test and 1.5V battery test. The back light of the display is optional.

Front Panel Description

1. Display: 3 1/2 digit, 7 segment, 15mm high LCD.

2. Back light: When this button is pushed, the back light of the display is on; press the back light button once, and the back light is turned off.

3. Rotary switch: This switch is used to select functions and desired ranges as well as to turn on/off the meter.

4. Hold button: When this button is pushed, the display will keep the last reading and a "H" symbol will appear on the LCD until it is pushed again.

5. "10A" jack: Plug in connector for red test lead for 10A measurement. "COM" jack.

6. "VmA" jack: Plug in connector for black (negative) test lead.

7. "VΩmA" jack: Plug in connector for red (positive) test lead for voltage, resistance, and current (except 10A) measurements.

Specifications

Accuracy is specified for a period of one year after calibration and at 18°C to 28°C (64°F to 82°F) with relative humidity up to 80%.

General

DC Voltage

Range Resolution Accuracy
200mV 100μV ±1% of rdg ± 2 digits
2V 1mV ±1% of rdg ± 2 digits
20V 10mV ±1% of rdg ± 2 digits
200V 100mV ±1% of rdg ± 2 digits
500V 1V ±1.2% of rdg ± 5 digits

Overload Protection: 250V rms. For 200mV range and 500V DC or rms. AC for other ranges.

DC Current

Range Resolution Accuracy
200μA 100mA ±2% of rdg ± 5 digits
2mA 1μA ±2% of rdg ± 5 digits
20mA 10μA ±2% of rdg ± 5 digits
200mA 100μA ±2% of rdg ± 5 digits
10A 10mA ±3% of rdg ± 5 digits

Overload Protection: F 500mA/250V fuse. (10A range unfused)

AC Voltage

Range Resolution Accuracy
200V 100mV ±2.5% of rdg ± 10 digits
500V 1V ±2.5% of rdg ± 10 digits

Overload Protection: 500V DC or rms. AC for all ranges. Frequency range: 40Hz to 400Hz. Response: Average responding, calibrated in rms. of a sine wave.

Diode & Continuity

Range Description
🔊︎ If continuity exists (about <50Ω±30Ω), built-in buzzer will sound.
Show the approx. forward voltage drop of the diode.

Resistance

Range Resolution Accuracy
200 0.1 ±1% of rdg ± 5 digits
2k 1 ±1% of rdg ± 5 digits
20k 10 ±1% of rdg ± 5 digits
200k 100 ±1% of rdg + 5 digits
2M 1k ±1.5% of rdg ± 5 digits

Maximum Open Circuit Voltage: 2.8V. Overload Protection: 250V DC or rms. AC for all ranges.

Transistor hFE Test (0-1000)

Range NPN & PNP Test Range 0-1000 Test Current Ib=10μA Test Voltage Vce=2.8V

Battery Testing

Range Accuracy
1.5V ±2.5% of rdg +2 digits

Operating Instructions

DC Voltage Measurement

  1. Connect the red test lead to the "V.Ω.mA" jack and the black lead to the "COM" jack.
  2. Set rotary switch at desired DCV position. If the voltage to be measured is not known beforehand, set range switch at the highest range position and then reduce it until satisfactory resolution is obtained.
  3. Connect test leads across the source or load being measured.
  4. Read voltage value on the LCD display along with the polarity of the red lead connection.

DC Current Measurement

  1. Connect the red test lead to the "V.Ω.mA" jack and the black test lead to "COM" jack. (For measurements between 200mA and 10A, remove red lead to "10A" jack.)
  2. Set the rotary switch at desired DCA position.
  3. Open the circuit in which the current is to be measured, and connect test leads in series with the circuit.
  4. Read current value on LCD display along with the polarity of red lead connection.

AC Voltage Measurement

  1. Connect the red test lead to "V.Ω. mA" jack and the black test lead to the "COM" jack.
  2. Set the rotary switch at desired "V~" range position.
  3. Connect test leads across the source or load being measured.
  4. Read voltage value on the LCD display.

Resistance Measurement

  1. Connect the red test lead to "V. Ω. mA" jack and black test lead to the "COM" jack. (The polarity of red lead is positive "+".)
  2. Set the rotary switch at desired "Ω" range position.
  3. Connect test leads across the resistor to be measured and read LCD display.
  4. If the resistance being measured is connected to a circuit, turn off power and discharge all capacitors before applying test probes.

Diode Test

  1. Connect the red test lead to "V.Ω.mA" jack and the black test lead to the "COM" jack (The polarity of red lead is positive "+".).
  2. Set the rotary switch at "🔊︎" position.
  3. Connect the red test lead to the anode of the diode to be tested and the black test lead to the cathode of the diode. The approx. forward voltage drop of the diode will be displayed. If the connection is reversed, only figure "OL" will be shown.

Transistor Test

  1. Set the rotary switch at "hFE" position.
  2. Determine whether the transistor under testing is NPN or PNP and locate the emitter base and collector leads. Insert the leads into proper holes of the hFE socket on the front panel.
  3. Read the approximate hFE value at the test condition of base current 10μA and Vce 2.8V.

Audible Continuity Test

  1. Connect red test lead to "V.Ω.mA", black test lead to "COM".
  2. Set range switch to "🔊︎" position.
  3. Connect test leads to two points of circuit to be tested. If continuity exists, built-in buzzer will sound.

Battery Test

  1. Connect the red test lead to "V.Ω.mA" jack and black test lead to the "COM" jack.
  2. Set the rotary switch at desired "1.5V mA + " position.
  3. Connect the red test lead to the battery "+" and the black test lead to the battery "-".
  4. Read mA value on the LCD display. If the value is less than 40mA, it means the battery is low.

Battery & Fuse Replacement

WARNING: To avoid electric shock, be sure the thermocouple has been removed before changing to another function measurement.

If "<0xE5><0x85><0x89>" appears on display, it indicates that the battery should be replaced.

Fuse rarely needs replacement and blows almost always as a result of operator's error.

To replace battery & fuse (500mA/250V), remove the 2 screws in the bottom of the case. Simply remove the old one and replace with a new one.

Be careful to observe battery polarity.

WARNING: Before attempting to open the case, always be sure that test leads have been disconnected from measurement circuits. Close case and tighten screws completely before using the meter to avoid electrical shock hazard.

Accessories

Models: MT-1210, Economic Digital Multimeter

File Info : application/pdf, 10 Pages, 2.17MB

PDF preview unavailable. Download the PDF instead.

MT-1210 Adobe PDF library 10.01

Related Documents

Preview Pro'sKit MT-7028 Network Toner & Probe Kit User Manual
Comprehensive guide for the Pro'sKit MT-7028 Network Toner & Probe Kit, detailing specifications, operation, and troubleshooting for cable tracing and testing.
Preview Pro'sKit MT-7063/MT-7064 PoE & LAN Cable Tester User Manual
Comprehensive user manual for Pro'sKit MT-7063 and MT-7064 PoE & LAN Cable Testers. Learn to test Ethernet network for Power over Ethernet (PoE) existence, identify Power Sourcing Equipment (PSE) types (End-span/Mid-span), and check RJ11/RJ12/RJ45 cable maps for continuity, opens, shorts, and crossovers. Includes safety instructions, product features, specifications, and operation guides for both models.
Preview Pro'sKit MT-8100 Phone Tester: Features, Specifications, and Package Contents
Detailed overview of the Pro'sKit MT-8100 phone tester, including its features, technical specifications, and what's included in the package for installers and repair technicians.
Preview Pro'sKit MT-1236 True RMS Digital Multimeter User Manual
The Pro'sKit MT-1236 is a high-quality, high-precision 3-5/6 True RMS digital multimeter designed for professional engineers, maintenance personnel, and educational use. This user manual provides comprehensive instructions for safe operation, measurement guidelines, and maintenance procedures.
Preview Pro'sKit MT-7063/MT-7064 PoE and LAN Cable Tester User Manual
Comprehensive user manual for Pro'sKit MT-7063 and MT-7064 PoE and LAN cable testers, detailing features, specifications, safety instructions, and operation for testing Ethernet and network cables.
Preview Pro'sKit MT-4103 Digital Insulation Tester User Manual
User manual for the Pro'sKit MT-4103 Digital Insulation Tester, covering its features, operation, safety instructions, and specifications.
Preview Pro'sKit Professional Tool Solutions Catalog Vol. 30
Explore the Pro'sKit Vol. 30 catalog featuring professional tool solutions for networking, telecom, electronics, and more. Discover high-quality tools, kits, and instruments for installation, maintenance, and repair, reflecting 30 years of innovation and service.
Preview Pro'sKit MT-7051N Multi-Network Cable Tester User Manual
User manual for the Pro'sKit MT-7051N Multi-Network Cable Tester, detailing its features, usage, and warranty information. This tester is designed for network testing and can automatically check for continuity, shorts, opens, and crossed wire pairs in various cable types.