Airmax PondSeries Floating Fountain Owner's Manual
Thank you for choosing the Airmax PondSeries Floating Fountain.
Product Overview
The Airmax PondSeries Floating Fountain is designed to enhance the beauty of ponds and lakes with various spray patterns. It is available in 1/2 HP, 1 HP, and 2 HP models.
Key Features:
- Operating Depth: 36" Minimum
- Includes 3 Spray Patterns: Classic, Trumpet, and Crown & Trumpet. Premium nozzles are available separately.
- 3 Year Warranty
Available Models:
- 1/2 HP Fountain (115v/60Hz) - #652597
- 1/2 HP Fountain (230v/60Hz) - #652596
- 1 HP Fountain (230v/60Hz) - #652150
- 2 HP Fountain (230v/60Hz) - #652151
See the fountain in action and explore spray patterns at: airmaxeco.com/pondseriesfountains
System Components
The fountain system includes:
- Fountain Pump with Quick Disconnect, Float Mount Ring and Classic Spray Pattern (installed)
- Fountain Float
- Power Cord
- Control Panel
- Trumpet Spray Pattern (interchangeable)
- Crown & Trumpet Spray Pattern (interchangeable)
Mooring Kit Options (Not Included):
- #651052 - 150' Mooring Kit
- #651054 - 250' Mooring Kit
- #651055 - 500' Mooring Kit
Power Cord: Available up to 600' in length with strain relief cable attachment.
Airmax Control Panel: Essential for proper operation and safety.
Important Safety Instructions
- Never enter the water when electrical equipment is plugged in or operating.
- This fountain is supplied with a grounding conductor. Ensure the control panel is connected only to a properly grounded power source to reduce the risk of electric shock.
- This fountain is not approved for use in swimming pool areas.
- Always use with the appropriate Airmax Control Panel.
- Never run the unit out of water, as this can damage seals and create a hazard.
- Never lift or drag the fountain by the power cord.
- During freezing temperatures, remove the fountain and store it indoors.
- When installing from a boat or raft, always wear a Coast Guard-approved personal flotation device.
- Always use a qualified electrician to install a power source.
Setup & Installation
A. System Components: Refer to the diagram for identification of all parts.
B. Prepping the PondSeries for Installation:
- Ensure a power source is accessible near the pond. If not, consult a licensed electrician.
- Mount the Control Panel securely next to the power source. Refer to the control panel manual for installation and wiring instructions. If you are unable to perform this, contact a Certified Airmax Service Technician.
- Choose Your Spray Pattern: The PondSeries automatically creates the classic pattern without a nozzle. To change patterns (Trumpet, Crown & Trumpet), unscrew the nozzle nut, replace the pattern, and hand-tighten the nozzle nut. It is recommended to remove the nozzle nut when using the classic pattern.
- Assembling the Unit:
- Lay the float flat with the Airmax logo facing up.
- Place the fountain pump assembly into the center of the float, ensuring the power cord passes through the center hole.
- Securely attach the power cord to the fountain pump lead quick disconnect.
- Attach the power cord strain relief to the D-ring on the intake basket assembly.
- Attach a mooring cable (not included) using the two outside mounting locations on opposite sides of the float.
- Installing the Airmax LED Fountain Light Set (Sold Separately): Clip the light into the mounting spot on the float and secure with the tension screw. Connect the light set power cord to the quick disconnect. Adjust lights to the desired direction. Attach the light set power cord strain relief to a loop under the float mount ring.
- Installing the PondSeries Fountain into your Pond or Lake:
- Ensure a minimum of 36" of water depth for proper operation.
- Tie one end of the mooring rope to a stake and place it securely in the ground.
- Walk around the pond, pulling the fountain across the water, and secure the other end of the mooring rope to a second stake.
- Ensure both mooring ropes are snug to prevent twisting or shifting.
- For anchoring with blocks, spread them apart to keep mooring lines snug and prevent the fountain from spinning.
Maintenance & Winter Storage
A. Maintenance:
- Disconnect all power before performing any maintenance.
- Periodically clean the fountain intake screen of debris, algae, or aquatic weeds.
- Periodically clean light set lenses with a non-abrasive brush and cleaner.
B. Winter Removal & Storage:
- Remove the fountain and lights from the pond before ice forms.
- Clean the unit before storing.
- Disconnect lights from the fountain and store them in an area above freezing temperatures.
C. Spring Installation Inspection:
- Before re-installing, check the condition of the power cord and quick disconnect connectors. Replace any worn or missing O-rings.
Troubleshooting - Fountain
IF FOUNTAIN WILL NOT TURN ON:
ISSUE | CORRECTION |
---|---|
GFCI tripped | Reset GFCI |
Power cord cut | Repair or replace power cord |
Intake plugged | Clean intake |
Timer not running | Check power to timer & battery back up |
Fountain power cord wired improperly | Refer to control panel wiring manual |
Not enough water in reservoir | Bring water level up to at least 36" at fountain |
Fountain impeller stuck | Remove fountain, clean or replace impeller |
Breaker tripped due to overcurrent | Reduce current load on circuit, check other equipment |
Breaker tripped to GFCI | 1/2 HP: check GFCI & breaker; 1 & 2 HP: check overload & breaker |
IF NOZZLE HAS POOR QUALITY STREAMS:
ISSUE | CORRECTION |
---|---|
Intake plugged | Clean intake |
Not enough water in reservoir | Bring water level up to at least 36" at fountain |
Debris caught in nozzle hole | Remove nozzle, clean, replace |
Water coming over the float | Check fountain float for water |
IF FOUNTAIN STARTS AND STOPS:
ISSUE | CORRECTION |
---|---|
Intake plugged | Clean intake |
Not enough water in reservoir | Bring water level up to at least 36" at fountain |
IF STREAMS RAISE AND LOWER:
ISSUE | CORRECTION |
---|---|
Not enough water in reservoir | Bring water level up to at least 36" at fountain |
Water coming over the float | Check fountain float for water, replace if any |
IF FOUNTAIN IS HUMMING - RUNNING:
ISSUE | CORRECTION |
---|---|
Normal running | Nothing |
IF FOUNTAIN IS HUMMING - NOT RUNNING:
ISSUE | CORRECTION |
---|---|
Intake plugged | Clean intake |
Voltage not high enough for starting | Make sure voltage at receptacle is correct |
Fountain impeller stuck | Remove fountain, clean, replace impeller |
If your issue persists or is not covered, contact your Certified Airmax Service Technician. For fountain light set troubleshooting, refer to the manual included with your light set.
Replacement Parts
1/2 HP Replacement Parts:
- 652171: 1/2 HP Power Unit 115v
- 652172: 1/2 HP Power Unit 230v
- 1. 653100: Float Mount Ring Assembly, 34" Float
- 2. 651253: Float Mount Ring Bolt, Set of 4
- 3. 653102: PondSeries Discharge Horn Assembly
- 3a. 651311: Discharge Horn O-Ring
- 3b. 652163: Pump Screw Assembly
- 4. 653103: Upper Shroud with Bearing Assembly
- 5. 651620: Lower Shroud, 4"
- 6. 653104: Impeller and Clip Assembly, 1/2 HP
- 6a. 651474: Spiral Retaining Ring
- 7. 653107: Thrust Bearing Assembly
- 8. 653215: 3/4" SS Steel Shaft, 1/2-1 HP
- 9. 653108: 3/4" SS Shaft Coupler Assembly, 1/2 HP
- 10. 652156: Sand Slinger Washer Assembly, 1/2 HP
- 11. 652158: Motor Assembly, 115v, 1/2 HP
- 652159: Motor Assembly, 230v, 1/2 HP
- 12. 651878: 3-Pin Motor Lead with Disconnect
- 13. 652162: Cooling Shroud Screw Assembly
- 14. 651861: Cooling Shroud Assembly, 1/2 HP
- 15. 651196: T-Knob Assembly
- 16. 653109: Intake Basket, 1/2 HP
- 17. 653112: Intake Extension with Hardware
- 18. 653111: Intake Bottom Plate with Hardware
- 19. 652219: Tie-Down Ring
- 20. 651500: Float, 34", Blue w/Airmax Logo
Included Spray Patterns (not pictured):
- N/A: Classic Pattern
- 651887: Trumpet Pattern
- 651889: Crown & Trumpet Pattern
1 HP 230v Replacement Parts:
- 652173: 1 HP Power Unit 230v
- 1. 653101: Float Mount Ring Assembly, 46" Float
- 2. 651253: Float Mount Ring Bolt, Set of 4
- 3. 653102: PondSeries Discharge Horn Assembly
- 3a. 651311: Discharge Horn O-Ring, 4"
- 3b. 652163: Pump Screw Assembly
- 4. 653103: Upper Shroud with Bearing Assembly
- 5. 651620: Lower Shroud, 4"
- 6. 653105: Impeller and Clip Assembly, 1 HP
- 6a. 651474: Spiral Retaining Ring
- 7. 653107: Thrust Bearing Assembly
- 8. 653215: 3/4" SS Shaft, 1/2-1 HP
- 9. 653213: 3/4" SS Shaft Coupler Assembly, 1-5 HP
- 10. 652157: Sand Slinger Washer Assembly, 1-5 HP
- 11. 652160: Motor Assembly, 230v, 1 HP
- 12. 651933: 4-Pin Motor Lead with Disconnect
- 13. 652162: Cooling Shroud Screw Assembly
- 14. 651862: Cooling Shroud Assembly, 1 HP
- 15. 651196: T-Knob Assembly
- 16. 653209: Intake Basket Assembly, 1 HP
- 17. 653112: Intake Extension with Hardware
- 18. 653111: Intake Bottom Plate with Hardware
- 19. 652219: Tie-Down Ring
- 20. 651502: Float, 46", Blue w/Airmax Logo
Included Spray Patterns (not pictured):
- N/A: Classic Pattern
- 651907: Trumpet Pattern
- 651909: Crown & Trumpet Pattern
2 HP 230v Replacement Parts:
- 652174: 2 HP Power Unit 230v
- 1. 653101: Float Mount Ring Assembly, 46" Float
- 2. 651253: Float Mount Ring Bolt, Set of 4
- 3. 653102: PondSeries Discharge Horn Assembly
- 3a. 651311: Discharge Horn O-Ring, 4"
- 3b. 652163: Pump Screw Assembly
- 4. 653103: Upper Shroud with Bearing Assembly
- 5. 651620: Lower Shroud, 4"
- 6. 655208: Impeller Hardware, 2-5 HP
- 7. 653106: Impeller with Hardware, 2 HP
- 8. 653107: Thrust Bearing Assembly
- 9. 653545: .752 SS Shaft, 2-5 HP
- 10. 653213: 3/4" SS Shaft Coupler Assembly, 1-5 HP
- 11. 652157: Sand Slinger Washer Assembly, 1-5 HP
- 12. 652161: Motor Assembly, 230v, 2 HP
- 13. 651933: 4-Pin Motor Lead with Disconnect
- 14. 652162: Cooling Shroud Screw Assembly
- 15. 651863: Cooling Shroud Assembly 2-5 HP
- 16. 651196: T-Knob Assembly
- 17. 653110: Intake Basket Assembly, 2 HP
- 18. 653112: Intake Extension with Hardware
- 19. 653111: Intake Bottom Plate with Hardware
- 20. 652219: Tie-Down Ring
- 21. 651502: Float, 46", Blue w/Airmax Logo
Included Spray Patterns (not pictured):
- N/A: Classic Pattern
- 651897: Trumpet Pattern
- 651899: Crown & Trumpet Pattern
For information on premium spray patterns, visit airmaxeco.com/pondseriesfountains.
Limited Warranty
Airmax, Inc. warrants to the original purchaser that any Airmax PondSeries Fountain component proving defective in materials or workmanship within 3 years from the original purchase date will be repaired or replaced at no charge, with freight prepaid. The end user assumes responsibility and expense for removal, packaging, and shipping to Airmax, Inc. for warranty claims and reinstallation.
Warranty is void if damage results from:
- Improper installation or electrical connection
- Improper voltage
- Alteration, lightning, careless handling, misuse, abuse
- Disassembly of the motor
- Failure to follow maintenance or operating instructions
- Modification or repair by an unauthorized facility
Airmax, Inc. and its dealers are not responsible for costs incurred during installation, removal, inspection, evaluation, repair, parts replacement, or return freight. Liability for loss of use, profits, goodwill, consequential damages, or personal injuries is disclaimed.
To initiate a warranty claim, notify the dealer who will assist in resolving the issue and may contact the factory. A Return Material Authorization (RMA) is required from the dealer before shipment. Freight collect shipments will not be accepted.
Parts must be returned freight prepaid, in original packaging, or packaging that prevents damage. Parts damaged during shipping will not be covered for shipping damage.
Warranty registration is highly recommended. Registration can be completed at airmaxeco.com/warranty within 30 days of purchase.
No implied warranties are made by Airmax, Inc. The retail purchaser's sole remedy is repair or replacement of the product as provided.
Contact Information
Airmax, Inc.
15425 Chets Way Street
Armada, MI 48005
Phone: (866) 4-AIRMAX
Website: www.airmaxeco.com