DELLA Portable Air Conditioner User and Care Manual
Part Number: 048-GM-48335
WARNING: READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE.
Visit: www.dellaproductsusa.com
Contact: 909.344.2588
Introduction
It is important that you read these instructions before using your new purchase and we strongly recommend that you keep them in a safe place for future reference.
Safety Information
Please read and understand this entire manual before attempting to assemble, operate, or install the product. This unit is intended for residential use only.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: POTENTIAL ELECTRICAL HAZARD IF NOT FOLLOWED. When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:
- Extreme caution is necessary when the unit is used by or near children, invalids, pets, or when the unit is left operating unattended.
- Always unplug the unit when not in use.
- Do not operate the unit with a damaged cord or plug or after the fan malfunctions, has been dropped, or damaged in any manner. Contact the manufacturer for resolution options.
- Do not use outdoors. Exposure to outdoor elements such as rain, snow, sun, wind, or extreme temperatures may cause the unit to become a safety hazard.
- This unit is not intended for use in bathrooms, laundry areas, and similar indoor locations, nor any locations that use GFCI outlets.
- Never place the unit where it may fall into a bathtub or other water receptacles.
- Do not run the cord under carpet. Do not cover the cord with throw rugs, runners, or similar coverings. Arrange the cord away from traffic areas and where it will not be tripped over.
- To disconnect the unit, first turn the power button to the OFF position and then remove the plug from the wall outlet.
- Do not allow foreign objects to enter or block any ventilation or exhaust opening as this may cause electric shock, fire, or damage the unit.
- This unit has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable liquids are used or stored, nor use flammable solvents to clean it. Keep the unit dry at all times.
- Use this unit only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
- Do not use abrasive solvents to clean the unit as it may cause damage to the finish or casing.
- The use of an extension cable is not recommended.
- Should the unit stop working, first check the fuse/circuit breaker located in the power cord before contacting the manufacturer or a certified service agent.
- Keep the unit upright while transporting and storing.
- When moving the air-conditioner, always turn off and disconnect the power supply, and move it slowly.
Notes:
- If any parts are received damaged please call your retailer.
- The power cord must be firmly grounded.
- If power cord is damaged, please turn off the unit and disconnect the power supply. It must be replaced from the dealer or a designated repair shop.
WARNING: It is normal for the power cord to feel warm to the touch. However, a loose fit between the outlet and the plug may cause overheating of the plug. If this occurs, try inserting the plug into a different outlet. Contact a qualified electrician to inspect the original outlet for damage.
Note: The cooling capacity of the unit may be affected by the height of your ceiling, quality of your insulation, or number of windows in your room. DELLA has made every effort to design and engineer a superior quality portable air conditioning unit that effectively and efficiently cools selected areas of the home or office. These portable air conditioner units are designed and engineered to provide supplemental air conditioning. To gain a better understanding of the performance capabilities of your new portable AC unit, you can contact your retailer in advance.
LCDI Plug Instruction
If you plug in the Air Conditioner, and there is no green light on the plug. Press the reset button on the LCDI plug. The green light should be on, indicating that the air conditioner is getting power from the electrical outlet.
If the plug continues to trip (which is a USA national safety standard feature) and the green light goes off, the cord may be damaged preventing you from resetting the unit. For your safety, contact a licensed electrician.
Parts List
Front Side Components:
- 1. Top Panel
- 2. Control Panel
- 3. Air Outlet
- 4. Remote control receiving window
- 5. Front Panel
- 6. Casters
Back Side Components:
- 7. Handle
- 8. Back Panel
- 9. Power Cord
- 10. Upper Filter
- 11. Exhaust Connector
- 12. Lower Filter
- 13. Water Plug
Accessories:
- Slide Bar
- Exhaust Hose
- Adjustable Slide
- Screws
- Remote Control
- Batteries
After unpacking the unit, please check whether all the above-mentioned accessories were included, and check their purposes in this manual.
Control Panel
The control panel features the following buttons:
- Fan Speed Button
- Mode Button
- Timer Button
- Up Button
- Down Button
- Power Button
Power Operation:
When Power is pressed, the unit goes directly into Cool Mode (Default set temperature at 72°F (22°C) and Fan runs on medium speed). Press again and the unit will shut off.
Mode Selection:
Press MODE to select the required working mode. All modes are confirmed on the display:
Operating Mode | Icon Description | Temperature Setting Range |
---|---|---|
COOL | [Cooling Icon] | 60°F -- 86°F (16°C--30°C) |
DEHUMIDIFY | [Dehumidify Icon] | 60°F -- 86°F (16°C--30°C) |
FAN | [Fan Icon] | N/A (Setting Range not applicable for Fan mode) |
Energy Conservation | [Energy Icon] | 60°F -- 86°F (16°C--30°C) |
Attention: When using COOL and DEHUMIDIFY functions, let the unit run for at least 3 minutes before shutting it off or switching between functions.
Fan Speed:
Press the FAN button to select a desired fan speed. Fan running speed can be adjusted in the following order:
[Low Speed Icon] Low Speed → [Medium Speed Icon] Medium Speed → [High Speed Icon] High Speed
Timer:
Pressing the Timer button allows you to set the timer for auto on and auto off functions.
- Auto-On Setting: When the air conditioner is OFF, use the UP and Down buttons to select a desired "auto-on" timer. The timer will display on the LCD panel. Timer can be changed at any time in 1-24 hours.
- Auto-Off Setting: When the air conditioner is ON, use the UP and Down buttons to select a desired "auto-off" timer. The timer will display on the LCD panel. Timer can be changed from 1-24 hours.
Note: For example, if you set the Timer to '2', the unit will turn on or shut off automatically after 2 hours. Timer interval is 1 hour. Once set, the timer icon will flash 5 times for confirmation.
Up / Down Buttons:
To control the set temperature and timer setting:
- Press the “UP” or “DOWN” button to select a desired temperature (60-86°F).
- Use for timer instructions: auto-on setting and auto-off setting.
- Press the “UP” and “DOWN” buttons simultaneously to interchange between Celsius and Fahrenheit degrees.
Other Functions:
- Auto Swing: Press the “TIMER” and “SPEED” buttons simultaneously to start or close the auto oscillation function.
- Sleep: Press the "TIMER” and “UP” buttons simultaneously to start or close the sleep function.
- Energy Conservation: Press "MODE" to activate Energy Conservation mode for low energy consumption.
- Auto-clean: Press “MODE” to activate Auto Clean. This function runs for three minutes before shutting off under COOL and DEHUMIDIFYING modes.
Remote Control
The air conditioner responds to all signals sent by the remote control. The remote control requires 2 pcs of AAA batteries to operate.
The remote control has the following buttons:
- Up and down button (for temperature/timer)
- Fan speed button
- Timer button
- Sleep button
- LCD display window
- Power button
- Mode button
- Auto-swing button
- Auto-clean button
Point the remote control handset towards the control panel of the unit and press the relevant button:
- Power: To turn the unit on/off.
- Mode: To select Cool, Dehumidify, Fan, and Energy Conservation mode.
- Up: To turn up the temperature or timer.
- Down: To turn down the temperature or timer.
- Fan: To set fan speed in sequence: Low → Medium → High.
- Auto Swing: Press this button to turn on or turn off auto-swing function.
- Auto Clean: Press this button to start auto clean function under cooling and dehumidifying function.
- Sleep: Press this button to select or cancel sleep mode.
- Timer: Press this button to set AUTO-ON and AUTO-OFF time.
Battery Installation:
Before using your remote, install two AAA batteries into the remote control.
- Press and slide the battery cover on the back of the remote control to remove it.
- Insert two new alkaline AAA batteries into the battery compartment, ensuring proper polarity.
- Reattach the battery cover, making sure the locking tab clicks into place.
Note: Be sure to note proper polarity of batteries.
Battery Notes:
- Use alkaline batteries only. Do not use rechargeable batteries.
- When replacing batteries, always replace both batteries with new ones; do not mix old and new batteries.
- If the air conditioner will not be used for an extended period, remove the batteries from the remote control.
Remote Control Storage:
- Insert the remote controller into the bracket in the back of the unit.
- To avoid losing the remote control, please keep it stored when not in use.
Important Notes on Operation:
- The compressor will start approximately 3 minutes after the unit is turned on to prolong its life. After switching the unit off, wait at least 3 minutes before turning it back on.
- The compressor will switch off when the room temperature is lower than the set temperature. The fan will continue to work. When the ambient temperature rises above the set temperature, the cooling will resume.
Safety Protection Features:
- Anti-frozen protection function: Under COOL mode, if the tube temperature is ≤36°F/2°C for 20 seconds after the compressor runs for over 10 minutes, the anti-frozen protection will activate. The LCD display will show 'E4', and the compressor and water wheel motor will stop working, while the upper fan continues running. If the tube temperature rises to ≥46°F/8°C, the unit will stop anti-frozen protection and recover to original working condition. The compressor will restart with a 3-minute delay for protection.
- Auto Defrosting Operation: If the coil temperature is too low and humidity is too high, frost may form on the coils. The air conditioner will stop operation for 8-10 minutes for auto defrosting. Once the coils reach a temperature that prevents frost formation, the operation will recover automatically. Turn on your machine and wait for three minutes.
- Water-Full Water Level Protection: This is performed by a water-level switch. The switch is always closed and opens only when an abnormal situation occurs in the water reservoir. When the reservoir is full, the switch moves, and the unit stops working. Please drain the water.
Installation Instructions
ATTENTION:
- a) Before you start, place the unit on a firm, level surface near a grounded 115V/60Hz power outlet. Only operate in an upright position.
- b) We recommend keeping the exhaust hose as short as possible to minimize heat loss back into the room.
- c) Ensure adequate space for air to flow around the unit, at least 50cm/19.7" from walls, curtains, draperies, or heat sources. Any blockage can lead to overheating of the air conditioner.
- d) The flexible exhaust hose can be extended from 10.63" to 59" for mounting. Keep the hose as short as possible to minimize heat loss back into the room.
- e) This hose length is designed according to the air conditioner's specifications. Do not use an extension or a different hose, as this may lead to malfunctioning.
- f) Handle with care to prevent any kinks or bends in the exhaust hose.
The unit is a portable air conditioner that can be moved from room to room.
Note: The window kit is designed for sliding windows or doors only and is not suitable for casement style windows.
Assemble the Outdoor Adaptor:
Align the two halves of the outer adaptor and gently snap them together. Note: To prevent damage, do not use excessive pressure.
Install the Outward Adaptor and Window Slide Bar:
- Measure and verify if your window kit fits the dimensions of your sliding window. If the kit is larger than your window dimensions, it can be cut with a saw or power tool. If the kit is too short, you may order an additional window kit from the online store.
- Screw the slide bar connector into the exhaust hose.
- Spin the exhaust hose into the air outlet located at the rear of the unit (counter-clockwise).
- Insert the slide bar connector into the adjustable slide bar.
- Extend its length to match the width of the window (vertically or horizontally), and then tighten the screw to hold the length of the slide bar.
- Ensure the adjustable slide bar fits your window securely and stays in place.
- Close and lock your window on the slide Bar.
Or Install Directly Through a Wall/Window:
Cut a 150mm diameter hole in the wall or window, and feed the exhaust hose through the opening.
Drainage
1. Manual Drain:
This unit features a high-efficiency self-evaporative system where condensate is recycled. However, under extreme humidity, manual draining may be necessary. The portable air conditioner has an inner water reservoir with a safety micro switch. When the reservoir is full, the safety switch activates, and an alert icon turns on, indicating manual draining is required through the water hole on the back of the unit.
To manually drain the unit: Turn off the unit, place a pan or tray under the water hole, remove the plug and cap, and let the water drain. Once fully drained, replace the plug and turn the unit back on.
2. Continuous Drainage:
Unscrew the drain cover and unplug the water stopper. Connect a 12mm drain hose to the drain hole, ensuring it reaches as deep as possible to avoid leakage. Route the drain hose to a bathroom or outdoor drain.
Please note: The drain outlet must be at or below the level of the drain hose connection. NOTE: You need to purchase a 13mm PVC drain hose separately.
Maintenance
ATTENTION:
- Before cleaning, turn the unit OFF and disconnect it from the electrical outlet.
- Do not use gasoline or other chemicals to clean the unit.
- Do not submerge the unit in water for cleaning.
- Dry thoroughly before reassembling or storing.
- Never operate the unit without the air filter installed.
Cleaning the Housing:
To clean the unit's surface, use a gentle detergent and a damp cloth, then wipe dry with a soft clean cloth. Avoid strong chemicals, oil-based products, detergents, or chemically treated cloths, as these can damage the housing.
Cleaning the Filter:
The air filter should be cleaned at least every 2 weeks to prevent clogging with dust and dirt. Open the air inlet grille on the back of the unit, remove the air filters, and clean them with a gentle detergent in lukewarm water. Allow the filters to dry completely, preferably in direct sunlight, before reinserting them into the unit.
Additional Maintenance and Tasks Prior to Storage:
- a. For seasonal storage, run the unit in Fan Mode for a couple of hours to ensure the interior is completely dry.
- b. Allow the unit to air dry for 24 hours with the drain plug and cap removed.
- c. Clean or change the air filter.
- d. Store the power cord and protect the unit from dust by placing it back in its original box.
- e. Store in a dry place inaccessible to children or pets.
To Return Unit for Warranty or Repair:
It is important to package the unit correctly. Reuse all original Styrofoam and cardboard packaging. Repackaging should be the reverse of the unpacking process.
- Seal the top flaps of the cardboard box with packing tape and flip the box upside down (opening pointing towards the ground).
- Place the Styrofoam and upside-down box on top of the unit.
- Flip the unit and box over, then place the bottom Styrofoam and cardboard "cap" onto the unit.
- Securely tape the bottom of the box with packing tape.
- Place the return sticker on the top flap. The unit is now ready to ship.
Reminder:
Unit contains R410A. Waste Electrical products must not be disposed of with household waste. This product should be taken to your local recycling center for safe treatment.
Troubleshooting
Problem | Possible Causes | Corrective Action |
---|---|---|
The unit does not start when pressing on/off button | Water full indicators blink and water tank is full. | Drain the water from the water tank. |
Room temperature is higher than the set temperature. | Reset the temperature. | |
Room temperature is lower than the setting temperature. | Reset the temperature. | |
Not cool enough | The doors or windows are not closed. | Make sure all the windows and doors are closed. |
There are heat sources inside the room. | Remove the heat sources if possible. | |
Exhaust air hose is not connected or blocked. | Connect or clean the exhaust air hose. | |
Temperature setting is too high. | Reset the temperature. | |
Air inlet is blocked. | Clean the air inlet and filters. | |
The unit is noisy/loud | The ground is not level or not flat enough. | Place the unit on a flat, level ground if possible. |
The sound comes from the flowing of the refrigerant inside the air conditioner. | It is normal. | |
The compressor does not seem to be working | The overheat protection may be activated. | Wait 30 minutes until the temperature has decreased, then turn on the unit again. |
The remote control does not function | Remote control signal is not detected by the control panel. | Make sure the remote control is correctly aimed at the control panel. |
Distance too great. | N/A (Implied: move closer) | |
The batteries are drained. | Check batteries on the remote. | |
CH01 code displays | Room temperature sensor failure | Check the room temperature sensor and related circuits. |
CH02 code displays | Tube temperature sensor failure | Check the tube temperature sensor and related circuits. |
E4 code displays | Anti-freeze protection | Restore the functions automatically once anti-freeze protection is over. |
Displays (Water tank full icon) | Water tank in chassis is full | Drain the condensate and re-start the unit. |
ATTENTION: When abnormal situations occur, turn off the air conditioner and unplug it from the wall outlet. Contact a professional electrician or customer service for assistance.
Battery Caution & Disposal Information
Date: 7/11/12
- For best results, use type xxx (e.g., alkaline, carbon-zinc, etc.) batteries.
- Install only new batteries of the same type in your product.
- Failure to insert batteries in the correct polarity, as indicated in the battery compartment, may shorten the life of the batteries or cause them to leak.
- Do not mix old and new batteries.
- Do not mix Alkaline, Standard (Carbon-Zinc) or Rechargeable (Nickel Cadmium) or (Nickel Metal Hydride) batteries.
- Do not dispose of batteries in fire.
- Batteries should be recycled or disposed of as per state and local guidelines.
Limited Term Warranty
ONE (1) YEAR FROM DATE OF PURCHASE
WARRANTY TERMS
DELLA warrants that its merchandise is free from manufacturing defects (workmanship and/or material) and will either give credit or replace defective parts for up to one (1) year from the date of purchase, subject to the conditions below. If a manufacturing defect is found, DELLA must be notified promptly with a copy of the invoice and delivery ticket. Inspection by a DELLA employee or representative may be required to verify the defect, or you may need to submit samples with digital images. If replacement is required and the material is discontinued or unavailable, DELLA may substitute similar merchandise or offer full credit. This warranty is made solely to the retailer and is not transferable. Retailers must contact DELLA for claims; consumer claims are not handled directly. Retailers should retain invoices for one year for warranty purposes.
This warranty supersedes all implied warranties of merchantability and fitness for a particular purpose. No representative or agent of DELLA is authorized to assume additional liability or responsibility for DELLA's merchandise beyond what is described here. Implied warranties are limited to one year from the date of purchase. DELLA is not liable for indirect, consequential, or incidental damages.
ADDITIONAL CONDITIONS (Not Manufacturer's Defects)
- Colors may vary slightly due to photography and printing tolerances.
- Sizes are stated in U.S. standard measurements, but actual sizes are manufactured using the metric system, so sizes may vary slightly.
- No exchanges or refunds on pillows or toppers.
- No returns for buyer's remorse.
- No returns other than those stated above will be accepted.
ADDITIONAL CONDITIONS (Warranty Void)
Warranty is void under the following conditions:
- Improper maintenance or use resulting in damage.
- Product modifications by unauthorized parties.
- Floor samples or products sold "AS IS".
- Minor variations or differences between floor samples/illustrations and the actual product.
- Cost of packaging and shipping to/from DELLA (unless expressly arranged by DELLA).
- Use for industrial, commercial, institutional, or rental purposes (warranty is for residential use only).
- Dissatisfaction due to buyer's remorse.
- Normal wear and tear.
- Damages incurred during transportation.
- Damages incurred during assembly or maintenance.
- Damages incurred by accidents or abuse.
Additional conditions for warranty on upholstery are listed on the attached addendum.