Hansgrohe Versostat Thermostatic Mixer
Models: 15348000, 15368000
Safety Notes
- Gloves should be worn during installation to prevent crushing and cutting injuries.
- The product may only be used for bathing, hygienic and body cleaning purposes.
- Children as well as adults with physical, mental and/or sensory impairments must not use this product without proper supervision.
- Persons under the influence of alcohol or drugs are prohibited from using this product.
- The hot and cold supplies must be of equal pressures.
Installation Instructions
- Prior to installation, inspect the product for transport damages. After it has been installed, no transport or surface damage will be honoured.
- The pipes and the fixture must be installed, flushed and tested as per the applicable standards.
- The plumbing codes applicable in the respective countries must be observed.
- The product is not designed to be used with steam baths!
Technical Data
Specification | Value |
---|---|
Operating pressure | max. 1 MPa |
Recommended operating pressure | 0.1 - 0.5 MPa |
Test pressure | 1.6 MPa (1 MPa = 10 bar = 147 PSI) |
Hot water temperature | max. 70°C |
Recommended hot water temperature | 65°C |
Centre distance | 150±12 mm |
Connections G 1/2 | cold right - hot left |
Thermal disinfection | max. 70°C / 4 min |
Note: Safety against backflow. The product is exclusively designed for drinking water!
Symbol Description
Symbol: Do not use silicone containing acetic acid!
Safety Function
The desired maximum temperature, for example max. 42°C, can be pre-set thanks to the safety function.
Adjustment
After the installation, the output temperature of the thermostat must be checked. A correction is necessary if the temperature measured at the output differs from the temperature set on the thermostat.
Maintenance
- The check valves must be checked regularly according to DIN EN 1717 in accordance with national or regional regulations (at least once a year).
- To guarantee the smooth running of the thermostat, it is necessary from time to time to turn the thermostat from total hot to total cold.
Troubleshooting
Fault | Cause | Remedy |
---|---|---|
Insufficient water | - Supply pressure inadequate - Regulator filter dirty (#96922000) - Shower filter seal dirty - Backflow preventers dirty or leaking | - Check water pressure - Clean filter in front of the mixer and on the thermo cartridge (#96922000) - Clean filter seal between shower and hose - Clean backflow preventers, exchange if necessary |
Crossflow, hot water being forced into cold water pipe, or vice versa, when mixer is closed | - Thermostat has not been adjusted - Hot water temperature too low | - Adjust thermostat - Increase hot water temperature to 42°C to 65°C |
Spout temperature does not correspond with temperature set | - Thermo cartridge calcified | - Exchange thermo cartridge |
Temperature regulation not possible | - Filters are dirty - Check valve hasn't moved back | - Clean the filter / exchange filter - Exchange check valves |
Instantaneous heater didn't work with thermostat | - Flow limiter in handshower isn't removed | - Remove flow limiter |
Shower or spout dripping | - Dirt or sedimentation on valve seat. | - Dirt or sedimentation on valve seat, shut-off unit damaged |
Assembly Steps
The following describes the assembly steps based on the provided diagrams.
- Step 1: Prepare the wall for installation, ensuring correct pipe spacing (e.g., 150 mm center-to-center for G 1/2 connections).
- Step 2: Mount the wall unions into the wall.
- Step 3: Attach the main mixer body to the wall unions.
- Step 4: Connect the shower hose to the shower outlet.
- Step 5: Connect the tub spout to the tub outlet.
- Step 6: Install the thermostat cartridge into the mixer body.
- Step 7: Attach the control handles and trim.
- Step 8: Connect hot and cold water supply lines to the mixer.
- Step 9: Perform initial flushing and leak checks.
- Step 10: Adjust the Safety Function to set the desired maximum temperature (e.g., 42°C).
- Step 11: Check the final output temperature and make adjustments if necessary.
Refer to pages 31-33 for detailed visual assembly instructions.
Dimensions and Diagrams
Dimensions: Key measurements include center distance (150±12 mm) and G 1/2 connections. Refer to page 35 for detailed drawings.
Flow Diagram: Shows two outlets, one for the shower and one for the tub.
Technical Drawings: Illustrate the product's external form and internal components, including part numbers for spare parts.
Refer to page 35 for detailed dimension drawings and flow diagrams.
Spare Parts
Key spare parts include:
- Filter cartridge (Part No. 96922000)
- Thermostat cartridge
- Check valves
- Seals and gaskets
- Control handles
- Various fittings and connectors
Refer to page 36 for a complete list of spare parts and their corresponding part numbers.
Cleaning and Maintenance
Regular cleaning is recommended using mild cleaning agents. Avoid abrasive cleaners or those containing acetic acid.
Maintenance includes regular checks of check valves (at least annually) and occasional "exercising" of the thermostat by moving it between fully hot and fully cold settings to ensure smooth operation.
Refer to page 34 for detailed cleaning recommendations and maintenance procedures.
Contact and Warranty
For warranty information and contact details, please refer to the manufacturer's website or documentation.
Refer to page 34 for contact and warranty information.