Split Inground Light Installation Instructions
Product Specifications
Product Specifications | HV1845T | HV1845RGBW |
---|---|---|
Model No. | HV1845T | HV1845RGBW |
Name | Split | Split |
Material | 316 Stainless Steel | 316 Stainless Steel |
Colour | Stainless Steel | Stainless Steel |
IP Rating | IP67 | IP67 |
Input Voltage | 12v DC (Low Voltage) | 12v DC (Low Voltage) |
Protection Class | Class II | |
Lamp Base | Built In LED | |
Lamp Wattage | 1x 18w | 1x 18w |
Colour Temp | TRI Colour - 3000k, 4000k, 5500k | RGBW (RGB + 3000K) |
Lumens | 1200lm, 1290lm, 1350lm | 550lm (3000k) |
CRI | > 80 | |
Wiring | Parallel | |
Dimmable | No | Yes with RGBW Controller |
Warranty | 3 Years Replacement* |
Dimensions
The dimensions diagram shows the required cutouts for installation. For the fitting with a canister, a cutout diameter of 241mm is specified. Without a canister, a cutout diameter of 235mm is required. The fitting itself has a diameter of 180mm, a height of 75mm, and a recess of 45mm.
Adequate Drainage
The adequate drainage diagram illustrates how to ensure longevity for the inground light. It recommends a slight decline on the ground level to allow water to run away from the fitting. A 100mm space below the light fitting's canister, filled with 100mm to 150mm of crushed rock, is shown to facilitate proper drainage.
Important Safety Issues
- This product must be installed by a qualified electrician according to AS/NZS 3000.
- Ensure all electrical mains are disconnected before any installation.
- Modification of this product will void any warranty.
- Havit Lighting does not take responsibility for wrong installation, incorrect use, or use of installation material that does not belong to the system.
- When installing low voltage fittings, Voltage to fitting must be within +or- 5% of voltage required; if not within this allowance, warranty will be voided.
- Aluminium and 304SS fittings must not be installed within 5km of any salt water environments.
- All 316 stainless steel fittings must have regular cleaning maintenance to avoid any tea staining from forming on fitting. (Warranty does not cover Tea Staining)
- All o-rings and seals must be in place correctly to maintain warranty.
- When installing inground light fittings, adequate drainage must be allowed to prevent fittings from sitting in water for a long period of time. If no drainage is allowed, warranty will be voided.
- See sample adequate drainage diagram for correct installation method.
- This form may be updated at any time due to product improvements; please check online installation form for most current version.
Steps for Installation: HV1845T
- Make sure that the electrical circuit is free of voltage (master switch off).
- Make a hole where fitting is to be placed using dimensions provided on line drawings, making sure adequate drainage is allowed.
- Insert canister, and ensure that the top is level with ground or floor. Failure to do so will void warranty.
- Using an appropriate 12v DC LED Driver - DO NOT CONNECT LIGHT FITTING DIRECTLY TO 240V.
- Connect the cable - If more than one fitting installed, wiring must be done in parallel.
- Strip back the cable on both fitting and cable run and twist the positive cables together. Then connect neutral cables together.
- Solder all joins using solder and either a heat gun or butane gas torch.
- Cover connections using an adhesive lined heat shrink or gel cap to make connection watertight. Failure to do this will void warranty.
- Heat the heat shrink or crimp the gel cap making sure all connections are covered.
- Make sure the seals are still in place and screws are tight to avoid any water penetration.
- Fitting is preset to 3000k; locate cap on bottom of fitting and remove by twisting anti-clockwise. Slide switch to desired colour temperature, reattach cap making sure it is tight.
- Insert fitting into canister.
- Apply silicon around edge of fitting to prevent any water from getting inside to electrical connections.
- All connections must be carried out carefully; inspect all contacts before switching back on the electric circuit.
Steps for Installation: HV1845RGBW
- Make sure that the electrical circuit is free of voltage (master switch off).
- Make a hole where fitting is to be placed using dimensions provided on line drawings, making sure adequate drainage is allowed.
- Insert canister, and ensure that the top is level with ground or floor. Failure to do so will void warranty.
- Connect the cable.
- Use an appropriate 12v DC LED Driver and RGBW LED Controller - DO NOT CONNECT LIGHT FITTING DIRECT TO 240V.
- Do this by stripping back the cable on both fitting and cable run and twist cable together, making sure all colours are correctly joined to the correct colour:
- Black = Positive
- Red = Red
- Green = Green
- Blue = Blue
- White = White
- Solder all joins using solder and either a heat gun or butane gas torch.
- Cover connections using an adhesive lined heat shrink or gel cap to make connection watertight. Failure to do this will void warranty.
- Heat the heat shrink or crimp the gel cap making sure all connections are covered.
- Connect cable run to RGBW Controller.
- Connect the RGBW Controller to 12v DC LED Driver.
- Apply silicon around edge of fitting to prevent any water from getting inside to electrical connections.
- All connections must be carried out carefully; inspect all contacts before switching back on the electric circuit.
Steps for Installation: HV1845-F-SH
- Remove nuts on back of fitting and set aside.
- Remove cover and replace with security face.
- Reattach nuts and tighten, making sure seals are still in place.
- Insert fitting into canister.
- Insert screws and tighten.
Contact and Additional Information
Contact Details:
143 Beauchamp Road
Matraville NSW 2036
Australia
Tel: 02 9381 8300
Fax: 02 9666 8881
Email: sales@havit.com.au
Web: www.havit.com.au
Installation Requirement: Must be installed by a licensed electrician.
Warranty Terms & Conditions*: 3 Years Replacement*
Additional Information: [Refer to Havit Lighting website for further details.]