Taubik LCD Display M5 User Manual
Latest Version 2016
1. Exterior Parameters
Casing Material: ABS
Display Material: High Hardness Acrylic (the same hardness value as tempered glass)
31.8mm handlebar ring diameter options: 22.2mm /25.4mm / 28.6mm
2. Operating Voltage and Connections
Operating Voltage: DC24V / 36V / 48V / 60V / 64V (selectable via display setting). Other operating voltages can be customized.
3. Functions
a. Display
Speed Display, PAS Level Display, Battery Level Display, Error Indication, Total Mileage, Single Mileage, Single Running Time, Light Signal.
b. Control and Settings
Power Switch, Front Light Control, 6km/h Inching Control, Wheel Diameter Setting, Top Speed Setting, Auto-Hibernation Interval, Backlight Brightness Setting, Voltage Level Setting.
c. Communications Protocol: UART
Display Readings (display at start for 1 second)
Display Details
3.1 Light
Turned on manually or environment-sensed (requires light-sensitive support).
3.2 Battery Level
Display shows battery level.
3.3 Multi-Functions Display
Total Mileage: ODO, Single Mileage: TRIP A, Single Mileage: TRIP B, Current Voltage: VOL, Operating Current: CUR, Display Booting Time: TM.
3.4 Riding Mode
- Walk: Walking Boost
- Cruise: Constant Speed Cruise
- PAS: Power Assist Level (0-9 Adjustable)
3.5 Speed Display
Maximum Speed: MAX, Average Speed: AVG. Measuring Unit: MPH or KM/H. The display will calculate the actual travelling speed based on the wheel diameter and signal data.
3.6 Vehicle Status
Error Code (decimal) | Indications | Note |
0 | Normal | |
1 | Reserved | |
2 | Brake | |
3 | PAS Sensor Failure (riding mark) | Not Realized |
4 | 6km/h Cruise | |
5 | Real-Time Cruise | |
6 | Low Battery | |
7 | Motor Failure | |
8 | Throttle Failure | |
9 | Controller Failure | |
10 | Communications Receiving Failure | |
11 | Communications Sending Failure | |
12 | BMS Communications Failure | |
13 | Light Failure |
3.7 Settings
- P01: Backlight Brightness (1: darkest; 3: brightest)
- P02: Mileage Unit (0: KM; 1: MILE)
- P03: Voltage Class: 24V / 36V (default) / 48V
- P04: Hibernation Time (0: never, other figures refer to the hibernation time) Unit: minute
- P05: PAS Level – 0/3 Gear Mode, 1/5 Gear Mode
- P06: Wheel Diameter Unit: inch, Precision: 0.1. To get accurate speed display, this parameter should be correct.
- P07: Magnet Steel Number for Speed Test. Range: 1-100. To get accurate speed display, this parameter should be correct. Gearless Motor: the value is the magnet steel number. Geared Motor: the reduction-gear ratio is required. The value = magnet steel number*reduction-gear ratio. For example, magnet steel number is 20, reduction-gear ratio is 4.3. The value input is: 86=20×4.3
- P08: Speed Limit. Range: 0-100km/h, parameter 100 indicates no speed limit. This parameter limits the max. speed of the vehicle. For example, input value 25 means the max. speed is 25km/h, the vehicle travelling speed can only reach the preset value. Deviation: ±1km/h (applies to both PAS and throttle mode). Note: The above-mentioned values are measured by metric unit (kilometers). When the measuring unit is switched to imperial unit (mile), the speed value displayed on the panel will be automatically switched to corresponding imperial unit, however the speed limit value in the imperial unit interface won't change accordingly.
IMPORTANT: P09-P15 only works under communications mode.
- P09: Zero / Non-zero Start Setting: 0: Zero Start, 1: Non-zero Start
- P10: Drive Mode Setting: 0: Power Drive – The specific gear of the assist drive decides the assist power value. In this status the handlebar does not work. 1: Electric Drive – The vehicle is driven by the handlebar. In this status the power gear does not work. 2: Power Drive + Electric Drive – Electric drive does not work in zero-start status.
- P11: PAS Sensibility. Range: 1-24
- P12: Assist Power Intensity. Range: 0-5
- P13: Power Magnet Steel Number: 5 / 8 / 12pcs
- P14: Current Limit Value: 12A by default; Range: 1-20A
- P15: Unspecified
- P16: ODO Zero-Out: Long press the upper key [M] for 5 seconds and ODO will zero out.
- P17: 0: Disable cruise, 1: enable cruise. Auto cruise optional (only for Protocol 2)
- P18: Display speed ratio adjustment range: 50%~150%
- P19: 0 is enabled. 0: with 0 and 1: without 0
- P20: 0:2 Protocol 1: 5S Protocol 2: Standby 3: standby
4. Keys
Arrangement of keys on the panel:
Introduction of Keys
Key operations involve short press, long press and long press of combination keys. Short press is used for short/frequent operations as:
- Short press the two keys [M] [M] to change assist power/speed during riding.
- Short press this key [M] to switch the readings in the multi-function display section.
Long press on a single key is used to switch mode/on/off status. Long press on combination keys to set parameters, which can avoid misoperations (short press on combination keys is disabled, for it's easy to induce misoperation and hard to manipulate).
Detailed Instructions
- Change Assist Power/ Electric Gear
In assist power mode:
- Short press [M] assist power +1. Short press [M] assist power -1.
- Enable / Disable 6km/h cruise, set real-time cruise and turn on/off the lights
- When the vehicle is parked, long press [M] to enter 6km/h cruise mode.
- When the vehicle is travelling, long press [M] to enter real-time cruise mode.
- Long press [M] to exit the cruise mode when the vehicle is in cruise mode.
- Long press [M] to turn on/off the lights.
- Turn on/off the LCD Panel
When the display panel is operating, long press [M] and it will be turned off, otherwise it will be turned on.
- Switch Displayed Readings in Multi-Functions Section
Short press [M] to switch readings shown in the multi-functions section.
- Set Parameters
Long press [M] + [M] to enter the setting interface. Customizable parameters include: Wheel Diameter (unit: inch); Magnet Steel Number; Backlight Brightness; Low Voltage Threshold (refer to setting: P01-P14).
In the setting interface, short press [M] or [M] to add/minus value to the parameter, which will blink after modified. After selecting the parameter that needs to be set,
- a. Long press [M] to save the current value, and the parameter will stop blinking;
- b. Short press [M] to switch to the next parameter and the previously set value will be saved at the same time.
- II. Press [M] + [M] to exit the setting and save the parameters. Without this operation, the system will automatically exit and save the modified parameters after 10 seconds.