270W Adapter FSP270-RXAN3
FSP270-RXAN3 Series
Features
- Certified IEC 62368-1 & CB 60950-1
- Meets USA EISA 2007
- Meets Energy Efficiency DOE Level VI
- Meets Code of Conduct Version 5 Tier 2
- High Reliability
- Low Profile
- Over Current Protection
- Over Temperature Protection
- Over Voltage Protection
- With PFC Circuit
Safety Standard Approval
Safety standard approvals include CULUS, TÜVRheinland, CE, and FCC compliance. Tested to Comply With FCC Standards for Home or Office Use.
Description
This product is a 240~270 watts AC to DC adapter intended for use in IPC systems, embedded systems, printers, monitors, charging systems, and POS systems that have high wattage demands. This adapter operates at 90 to 264 VAC input voltage. The unit meets CISPR32 EN55032 CLASS B, EN55024, and FCC PART 15B Class B emission limits, and is designed for ITE application.
Input Specifications
Input Voltage: 90-264 VAC
Input Frequency: 47-63 Hz
Input Current: 100Vac, 240Vac / full load ≤ 1.2A
No Load Power Consumption: 115Vac, 230Vac ≤ 0.5W
Touch Current: 264Vac / 50Hz ≤ 0.25mA
Power Factor: 115Vac, 230Vac / full load ≥ 0.9. Provisions for adding harmonic reduction per EN 61000-3-2 must be present.
Efficiency: See rating chart
Power Turn-on Time: At 100Vac / full load, output voltage shall remain regulation ≤ 3Sec
Hold-up Time: At 100Vac or 240Vac / full load, output voltage shall remain regulation ≥ 10ms
Inrush Current: 100Vac, 240Vac / full load, shall be less than the rating of adapter critical component (including rectifiers, fuse, surge, and current limiting device).
Operating Altitude: 5000 meters above sea level
Withstand Voltage: Between AC input and secondary applied DC 4242V, test time 1 minute, cut off current shall be less than 10mA
MTBF: 100Vac, 240Vac / full load, 300,000 hours at 25°C, standard SR332
Output Specifications
Output Voltage/Current: See rating chart
Total Output Power: See rating chart
Protection:
- Over Voltage: The adapter will enter into shutdown (no output) if over voltage occurs at the output terminal due to an internal fault. The output trip voltage shall not exceed 29/37* volts. Normal state is restored by AC reset.
- Short Circuit & Over Current: When an internal fault occurs, or an external fault (overload or short circuit) is applied to the output, the power supply shall shut down and enter auto-recovery mode.
- Over Temperature: The power supply will enter into shutdown when abnormal thermal rise occurs. Normal state is restored by AC reset.
- Brown-out: Set at 60Vac~70Vac.
Environmental Specifications
Working Temperature: 0~70°C (de-rating above 40°C)
Storage Temperature: -20~+80°C
Working Humidity: 20~80% RH non-condensing
Storage Humidity: 10~90% RH non-condensing
EMC Performance
EN55032: Class B conducted, Class B radiated
FCC: Class B conducted, Class B radiated
VCCI: Class B conducted, Class B radiated
EN61000-3-2: Meets Class D
EN61000-3-3: Meets regulation
EN61000-4-2 (Electrostatic Discharge): Air discharge: ±15 KV, Contact discharge: ±8KV (Criterion A)
EN61000-4-3 (Radiated Immunity): 80~1000 MHz, 3V/m, 80% AM (1kHz) (Criterion A)
EN61000-4-4 (Electrical Fast Transient/Burst): Impulse: ±1kV applied to L,N (Criterion A)
EN61000-4-5 (Surge): ±1kV applied differential mode, ±2kV applied common mode (Criterion A)
EN61000-4-6 (Conducted Immunity): 0.15~80 MHz, 3Vrms, 80% AM (1kHz) (Criterion A)
EN61000-4-8 (Magnetic Field): 50 Hz or 60Hz, 1A/m (Criterion A)
EN61000-4-11 (Voltage Dips/Interruptions):
- Voltage Dips: >95% reduction for 0.5 period (Criterion A), 30% reduction for 25 period (Criterion B)
- Voltage Interruptions: >95% reduction for 250 period (Criterion B)
Power De-rating: For 100Vac or 240Vac input, de-rating applies from 40°C (100% load) up to 70°C (50% load). Specific de-rating percentages are based on adapter critical component ratings and FSP specifications.
Derating Curves
Input Voltage Derating Curve: A line graph illustrating output power percentage versus input voltage (Vac). The curve shows that at 90Vac input, the output power is 100%. As the input voltage increases to 264Vac, the output power decreases to approximately 80%.
Output Power Derating Curve: A line graph illustrating output power percentage versus ambient temperature (°C). The curve shows that at 0°C, the output power is 100%. As the temperature increases to 70°C, the output power decreases to approximately 50%.
Output Voltage/Current Rating Chart
Model | Output Voltage | Output Current | Wattage | AC Inlet | Efficiency (DOE Level VI) | Efficiency (CoC V5 Tier 2) |
---|---|---|---|---|---|---|
FSP270-RHAN3 | 12V | 20A | 240W | C14 | ≥89% | ≥88% |
FSP270-RBAN3 | 19V | 14.21A | 270W | C14 | ≥88% | ≥89% |
FSP270-RAAN3 | 24V | 11.25A | 270W | C14 | ≥88% | ≥89% |
FSP270-RFAN3 | 48V | 5.62A | 270W | C14 | ≥88% | ≥89% |
FSP270-RWAN3 | 54V | 5A | 270W | C14 | ≥88% | ≥89% |
Mechanical & AC Connector Specifications
Diagrams illustrate the physical dimensions and AC connector details.
Overall Dimensions: 204.0±1.0 mm (Length) x 87.6±1.0 mm (Width) x 41.5±1.0 mm (Height).
AC Input Connector: IEC C14 type.
AC Cable: UL11353 12AWG BLACK, with a length of 1200±30 mm.
Housing: JWT C4202H00-2X3P or equivalent.
Rating Label: Located on the housing.
Power Indicator: Blue LED.
Cable Tie: Steel wire, PVC plated.
DC Connector Specifications (FSP270-RFAN3)
Diagrams detail the DC output connector and cable configuration.
DC Output Connector: Plug dimensions: 5.5mm (outer diameter) * 2.5mm (inner diameter) * 9.5mm (length).
Polarity: Center positive (+), outer negative (-).
Cable Color Coding: WHITE for positive, BLACK for negative.
Cable Lengths:
- 100±30 mm (from connector to first heat shrink)
- 70±30 mm (second heat shrink section)
- 1200±30 mm (total cable length)
Heat Shrink Tubing: Black and White.
Cable Tie: Steel wire, PVC plated.
Note: DC connector type may vary; please check with your FSP representative.