1 Introduction
1.1 Description
Operation of the control knob:
- Press the knob to enter menu or confirm selection.
- Turn the knob to change between selections.
- Hold the knob to exit the menu page and return to the home screen.
- Hold the knob to pause the fan before opening the lid.
The smoker controller unit features:
- [power port]
- [probe P1] Ambient Probe
- [probe P2] Food Temp Probe
- [probe P3] Food Temp Probe
- [foot]
- [blower fan]
Wireless connectivity is indicated by symbols (e.g., ? for Wi-Fi, ? for Bluetooth).
The associated smartphone application displays:
- Current grill temperature ([probe P1])
- Current food temperature ([probe P2], [probe P3])
- [target temperature]
- [fan power percentage]
- [timer indicator]
1.2 Item List
- Smoker Controller*1
- Power Plug*1
- Probe*3
- Blast Pipe*1
- Damper*1
1.3 Basic Operation
1.3.1 Main Page
The main screen displays:
- P1: Current Grill Temp
- P2: Food Temp
- P3: Food Temp
- T: Target Temp
- F: Fan Power%
- : Timer Indicator
Place the smoker controller on a stable and firm surface. Allow 30-45 minutes for the controller to gradually increase and stabilize the grill temperature.
1.3.2 Menu Setting
Click the Knob to enter the Main Menu. Options include:
- BBQ
- Manual Fan
- Set Alert
- Reset
Select "Reset" from the main menu to reset the current running mode.
1.3.3 BBQ
- Select "BBQ" from the Main Menu and click to enter.
- Rotate the knob to set a target temperature, then click the knob to confirm. The controller will return to the main interface and display BBQ status.
A display shows "SET TEMP 200".
The maximum fan power is limited to 70% on smaller grills. Manually set the fan, temperature alarm, temperature unit, and furnace size as needed.
2 Specification
- Model: ISC-007BW
- Size: 11.42in*8.66in*5.51in
- Weight of the Controller: 6.84oz/194g
- Input Voltage: DC 12V/2A
- Short Time Measurement Range: 0°C to 300°C (32°F~572°F)
- Continuous Monitoring Range: 0°C to 250°C (32°F~482°F)
- Temperature Accuracy: ±1°C/±1.8°F
- Calibration: ±12°F/±12°C
- Connection Methods: Supports Wi-Fi connection and Bluetooth connection
- Type of Wi-Fi Network: 2.4GHz Wi-Fi (Supports IEEE 802.11b/g/n)
- Maximum Bluetooth Connection Distance: 164ft (distance may be shorter with interferences).
- Waterproof: Not waterproof [waterproof status]
- Warranty: 1 year
Note: If using Wi-Fi, chart data is saved on the server. If using Bluetooth, data is saved to the device's local storage (up to 3 days).
3 Wireless Connection
3.1 Get Inkbird Pro app for your phone
Download the Inkbird Pro app from Google Play or App Store, or scan the [QR code] for direct download.
3.2 Account Registration
Register before using the Inkbird Pro app. Select your Country/Region, enter your e-mail. A verification code will be sent to your mailbox to confirm your identity. If you have a registered account, log in directly. The device supports 2.4GHz Wi-Fi routers only.
3.3 Wi-Fi Connection
3.3.1 Connect in Fast Flash Mode
- Plug in the smoker controller; it will turn on automatically.
- Open the app and click "+" to start connection, then choose ISC-007BW from the device list.
- Select Fast Flash mode and ensure the controller is in Fast Flash mode.
- Choose a preferred Wi-Fi network and enter the password to connect.
- Wait a few seconds and place the smoker as close to your phone as possible during pairing.
- Pairing Success!
3.3.2 Connect in AP mode
Fast Flash mode is recommended. If it fails, try AP Mode (Slow Flashing mode). Press and hold the button for seconds to switch to AP mode; the Wi-Fi icon will flash slowly.
- Plug in the smoker controller; it will turn on automatically.
- Open the app and click "+" to start connection, choose ISC-007BW from the device list.
- Confirm the Wi-Fi icon is blinking slowly and choose Slow Flash mode, then click "Next step" to start the connection.
- Choose a preferred Wi-Fi network, enter the password, and click "Confirm" to proceed.
- On your phone's WLAN interface, connect to the "SmartLife XXXX" Wi-Fi network without a password. Return to the app and confirm successful connection.
- Wait a few seconds and place the smoker as close to your phone as possible during pairing.
- Pairing Success!
Notes:
- Allow Location Services when connecting for the first time (e.g., "Allow While Using App" for privacy).
- Android phones require GPS to be turned on for proper functionality.
3.3.3 Wi-Fi Reset
Press and hold the "Wi-Fi" button for 5 seconds to reset Wi-Fi. Follow the guide to pair the device with your phone.
3.4 Bluetooth Connection
- Plug in the smoker controller; it will turn on automatically.
- Turn on your Bluetooth and click "Next step" to start the connection.
- Wait a few seconds and place the smoker as close to your phone as possible during pairing.
- Pairing Success.
Note: Android phones require GPS to be enabled for Google Play services. Once paired, re-pairing is only needed if you change your phone.
3.5 Main Interface of the Smoker Controller on Inkbird Pro
The Inkbird Pro app interface provides control and monitoring:
- Connection Status: Indicates if the device is connected.
- High Temperature Alarm Setting: Configure alarm thresholds.
- Stove Size: Select the size of the smoker/grill.
- Current Temperature: Displays the current temperature reading from probes.
- Target value of the Stove: The desired temperature setpoint.
- Fan Output Run Time: Duration the fan has been active.
- Fan Output Rate: Current fan speed or power level.
- Fan Output Control Switch: Turn the fan on/off.
- Stove Control Setting: General settings for the smoker.
- High Temperature Alarm Value: The specific temperature that triggers an alarm.
- Current Temperature: Another display of current temperature (possibly for a different probe).
- Temperature Graph: Visual representation of temperature over time.
- Timer Setting: Set or view timers.
- Preset Temperature Setting: Save or load common temperature profiles.
4 Precautions
Maximum temperature limits:
- Short time measurement: 300°C/572°F
- Long time measurement: 250°C/482°F
Exceeding these temperatures may burn out the probe and metal wire.
- Do not place probes or metal wire into fire or contact the heating tube directly.
- Do not immerse probes or metal wire in water, as this may lead to inaccurate measurements.
- Avoid pressing probes or metal wire too hard, which can damage the plastic film and cause short circuits.
- Remove the silicon case before using the probe.
Probe construction details:
- Teflon cable with stainless steel mesh (Length: approximately 120cm/3.9ft)
- [probe sensor]
- [non-waterproof]
FCC Requirement
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used according to instructions, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment causes harmful interference to radio or television reception (which can be determined by turning the equipment off and on), the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits for an uncontrolled environment. It should be installed and operated with a minimum distance of 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Contact Information
INKBIRD TECH.C.L
Email: Support@inkbird.com
Website: www.inkbird.com
Address: Room 1803, Guowei Building, NO.68 Guowei Road, Xianhu Community, Liantang, Luohu District, Shenzhen, China
Version: V 3.0
Certifications: FC, CE, RoHS, ? (Bluetooth)