Ferroli GIADA-C Cassette Air Conditioner Product Fiche
Overview
This document provides detailed product specifications for the Ferroli GIADA-C cassette air conditioning units. It covers various models, including their performance metrics for cooling and heating, energy efficiency ratings, and refrigerant details.
Model Specifications
The following tables detail the specifications for different Ferroli GIADA-C models.
GIADA-C ODU S 12 / GIADA-C IDU CASSETTE 12
Trademark | Outdoor model | Indoor model | Description | Symbol | Unit | Value |
---|---|---|---|---|---|---|
FERROLI | GIADA-C ODU S 12 | GIADA-C IDU CASSETTE 12 | Sound power level at standard rating conditions (indoor) | LWA | [dB(A)] | 55 |
Sound power level at standard rating conditions (outdoor) | [dB(A)] | 62 | ||||
Refrigerant type | R32 | |||||
GWP (1) | GWP | [kgCO2 eq.] | 675 | |||
SEER | SEER | 6,8 | ||||
Energy efficiency class in cooling | QCE | A++ | ||||
Annual electricity consumption in cooling (2) | [kWh/a] | 184 | ||||
Design load in cooling mode | Pdesignc | [kW] | 3,5 | |||
SCOP (average heating season) | SCOP/A | 4,1 | ||||
Energy efficiency class in heating (average season) | A+ | |||||
Annual electricity consumption in heating (average season) (3) | QHE | [kWh/a] | 922 | |||
Warmer heating season | Y | |||||
Colder heating season | N | |||||
Design load in heating mode (average season) | Pdesignh | [kW] | 2,7 | |||
Declared capacity at reference design condition (heating average season) | [kW] | 2,6 | ||||
Back up heating capacity at reference design condition (heating average season) | [kW] | 0,06 | ||||
Rated current for cooling | [A] | 4,5 | ||||
Rated current for heating | [A] | 4,5 | ||||
Rated capacity for cooling (Rated - min - max) | Prated cooling | [kW] | 3,5 0,9 4,2 | |||
Rated capacity for heating (Rated - min - max) | Prated heating | [kW] | 3,8 0,5 4,3 | |||
Rated power input for cooling (Rated - min - max) | PEER | [kW] | 1,0 0,2 1,5 | |||
Rated power input for heating (Rated - min - max) | PCOP | [kW] | 1,0 0,1 1,4 | |||
Rated Energy efficiency ratio | EERrated | 3,47 | ||||
Rated Coefficient of performance | COPrated | 3,74 | ||||
Voltage - Frequency - Phase no. | [V-Hz-Ph] | 220/240 50 1 |
GIADA-C ODU S 18 / GIADA-C IDU CASSETTE 18
Trademark | Outdoor model | Indoor model | Description | Symbol | Unit | Value |
---|---|---|---|---|---|---|
FERROLI | GIADA-C ODU S 18 | GIADA-C IDU CASSETTE 18 | Sound power level at standard rating conditions (indoor) | LWA | [dB(A)] | 59 |
Sound power level at standard rating conditions (outdoor) | [dB(A)] | 65 | ||||
Refrigerant type | R32 | |||||
GWP (1) | GWP | [kgCO2 eq.] | 675 | |||
SEER | SEER | 6,5 | ||||
Energy efficiency class in cooling | QCE | A++ | ||||
Annual electricity consumption in cooling (2) | [kWh/a] | 285 | ||||
Design load in cooling mode | Pdesignc | [kW] | 5,3 | |||
SCOP (average heating season) | SCOP/A | 4,1 | ||||
Energy efficiency class in heating (average season) | A+ | |||||
Annual electricity consumption in heating (average season) (3) | QHE | [kWh/a] | 1431 | |||
Warmer heating season | Y | |||||
Colder heating season | N | |||||
Design load in heating mode (average season) | Pdesignh | [kW] | 4,2 | |||
Declared capacity at reference design condition (heating average season) | [kW] | 3,6 | ||||
Back up heating capacity at reference design condition (heating average season) | [kW] | 0,59 | ||||
Rated current for cooling | [A] | 6,9 | ||||
Rated current for heating | [A] | 6,0 | ||||
Rated capacity for cooling (Rated - min - max) | Prated cooling | [kW] | 5,3 2,9 5,6 | |||
Rated capacity for heating (Rated - min - max) | Prated heating | [kW] | 5,3 2,4 6,1 | |||
Rated power input for cooling (Rated - min - max) | PEER | [kW] | 1,6 0,7 2,0 | |||
Rated power input for heating (Rated - min - max) | PCOP | [kW] | 1,4 0,7 2,0 | |||
Rated Energy efficiency ratio | EERrated | 3,40 | ||||
Rated Coefficient of performance | COPrated | 3,76 | ||||
Voltage - Frequency - Phase no. | [V-Hz-Ph] | 220/240 50 1 |
GIADA-C ODU S 24 / GIADA-C IDU CASSETTE 24
Trademark | Outdoor model | Indoor model | Description | Symbol | Unit | Value |
---|---|---|---|---|---|---|
FERROLI | GIADA-C ODU S 24 | GIADA-C IDU CASSETTE 24 | Sound power level at standard rating conditions (indoor) | LWA | [dB(A)] | 59 |
Sound power level at standard rating conditions (outdoor) | [dB(A)] | 68 | ||||
Refrigerant type | R32 | |||||
GWP (1) | GWP | [kgCO2 eq.] | 675 | |||
SEER | SEER | 6,3 | ||||
Energy efficiency class in cooling | QCE | A++ | ||||
Annual electricity consumption in cooling (2) | [kWh/a] | 394 | ||||
Design load in cooling mode | Pdesignc | [kW] | 7,1 | |||
SCOP (average heating season) | SCOP/A | 4,1 | ||||
Energy efficiency class in heating (average season) | A+ | |||||
Annual electricity consumption in heating (average season) (3) | QHE | [kWh/a] | 2117 | |||
Warmer heating season | Y | |||||
Colder heating season | N | |||||
Design load in heating mode (average season) | Pdesignh | [kW] | 6,2 | |||
Declared capacity at reference design condition (heating average season) | [kW] | 5,3 | ||||
Back up heating capacity at reference design condition (heating average season) | [kW] | 0,85 | ||||
Rated current for cooling | [A] | 8,8 | ||||
Rated current for heating | [A] | 8,5 | ||||
Rated capacity for cooling (Rated - min - max) | Prated cooling | [kW] | 6,5 3,3 7,9 | |||
Rated capacity for heating (Rated - min - max) | Prated heating | [kW] | 7,6 2,8 8,5 | |||
Rated power input for cooling (Rated - min - max) | PEER | [kW] | 2,0 0,8 2,8 | |||
Rated power input for heating (Rated - min - max) | PCOP | [kW] | 1,9 0,6 2,3 | |||
Rated Energy efficiency ratio | EERrated | 3,25 | ||||
Rated Coefficient of performance | COPrated | 4,01 | ||||
Voltage - Frequency - Phase no. | [V-Hz-Ph] | 220/240 50 1 |
GIADA-C ODU S 30 / GIADA-C IDU CASSETTE 30
Trademark | Outdoor model | Indoor model | Description | Symbol | Unit | Value |
---|---|---|---|---|---|---|
FERROLI | GIADA-C ODU S 30 | GIADA-C IDU CASSETTE 30 | Sound power level at standard rating conditions (indoor) | LWA | [dB(A)] | 63 |
Sound power level at standard rating conditions (outdoor) | [dB(A)] | 70 | ||||
Refrigerant type | R32 | |||||
GWP (1) | GWP | [kgCO2 eq.] | 675 | |||
SEER | SEER | 6,6 | ||||
Energy efficiency class in cooling | QCE | A++ | ||||
Annual electricity consumption in cooling (2) | [kWh/a] | 467 | ||||
Design load in cooling mode | Pdesignc | [kW] | 8,8 | |||
SCOP (average heating season) | SCOP/A | 4,2 | ||||
Energy efficiency class in heating (average season) | A+ | |||||
Annual electricity consumption in heating (average season) (3) | QHE | [kWh/a] | 2567 | |||
Warmer heating season | Y | |||||
Colder heating season | N | |||||
Design load in heating mode (average season) | Pdesignh | [kW] | 7,7 | |||
Declared capacity at reference design condition (heating average season) | [kW] | 6,8 | ||||
Back up heating capacity at reference design condition (heating average season) | [kW] | 0,90 | ||||
Rated current for cooling | [A] | 11,8 | ||||
Rated current for heating | [A] | 11,0 | ||||
Rated capacity for cooling (Rated - min - max) | Prated cooling | [kW] | 8,8 2,2 9,4 | |||
Rated capacity for heating (Rated - min - max) | Prated heating | [kW] | 9,4 2,7 9,7 | |||
Rated power input for cooling (Rated - min - max) | PEER | [kW] | 2,7 0,2 3,0 | |||
Rated power input for heating (Rated - min - max) | PCOP | [kW] | 2,5 0,4 2,5 | |||
Rated Energy efficiency ratio | EERrated | 3,23 | ||||
Rated Coefficient of performance | COPrated | 3,83 | ||||
Voltage - Frequency - Phase no. | [V-Hz-Ph] | 220/240 50 1 |
GIADA-C ODU S 36 / GIADA-C IDU CASSETTE 36
Trademark | Outdoor model | Indoor model | Description | Symbol | Unit | Value |
---|---|---|---|---|---|---|
FERROLI | GIADA-C ODU S 36 | GIADA-C IDU CASSETTE 36 | Sound power level at standard rating conditions (indoor) | LWA | [dB(A)] | 63 |
Sound power level at standard rating conditions (outdoor) | [dB(A)] | 70 | ||||
Refrigerant type | R32 | |||||
GWP (1) | GWP | [kgCO2 eq.] | 675 | |||
SEER | SEER | 6,7 | ||||
Energy efficiency class in cooling | QCE | A++ | ||||
Annual electricity consumption in cooling (2) | [kWh/a] | 549 | ||||
Design load in cooling mode | Pdesignc | [kW] | 10,5 | |||
SCOP (average heating season) | SCOP/A | 4,0 | ||||
Energy efficiency class in heating (average season) | A+ | |||||
Annual electricity consumption in heating (average season) (3) | QHE | [kWh/a] | 2975 | |||
Warmer heating season | Y | |||||
Colder heating season | N | |||||
Design load in heating mode (average season) | Pdesignh | [kW] | 8,5 | |||
Declared capacity at reference design condition (heating average season) | [kW] | 7,8 | ||||
Back up heating capacity at reference design condition (heating average season) | [kW] | 0,66 | ||||
Rated current for cooling | [A] | 17,5 | ||||
Rated current for heating | [A] | 13,5 | ||||
Rated capacity for cooling (Rated - min - max) | Prated cooling | [kW] | 9,9 2,7 11,4 | |||
Rated capacity for heating (Rated - min - max) | Prated heating | [kW] | 11,1 2,8 12,3 | |||
Rated power input for cooling (Rated - min - max) | PEER | [kW] | 3,0 0,9 4,2 | |||
Rated power input for heating (Rated - min - max) | PCOP | [kW] | 3,0 0,8 4,0 | |||
Rated Energy efficiency ratio | EERrated | 3,33 | ||||
Rated Coefficient of performance | COPrated | 3,71 | ||||
Voltage - Frequency - Phase no. | [V-Hz-Ph] | 220/240 50 1 |
GIADA-C ODU S 36T / GIADA-C IDU CASSETTE 36
Trademark | Outdoor model | Indoor model | Description | Symbol | Unit | Value |
---|---|---|---|---|---|---|
FERROLI | GIADA-C ODU S 36T | GIADA-C IDU CASSETTE 36 | Sound power level at standard rating conditions (indoor) | LWA | [dB(A)] | 63 |
Sound power level at standard rating conditions (outdoor) | [dB(A)] | 70 | ||||
Refrigerant type | R32 | |||||
GWP (1) | GWP | [kgCO2 eq.] | 675 | |||
SEER | SEER | 6,4 | ||||
Energy efficiency class in cooling | QCE | A++ | ||||
Annual electricity consumption in cooling (2) | [kWh/a] | 589 | ||||
Design load in cooling mode | Pdesignc | [kW] | 10,5 | |||
SCOP (average heating season) | SCOP/A | 4,0 | ||||
Energy efficiency class in heating (average season) | A+ | |||||
Annual electricity consumption in heating (average season) (3) | QHE | [kWh/a] | 2870 | |||
Warmer heating season | Y | |||||
Colder heating season | N | |||||
Design load in heating mode (average season) | Pdesignh | [kW] | 8,2 | |||
Declared capacity at reference design condition (heating average season) | [kW] | 7,8 | ||||
Back up heating capacity at reference design condition (heating average season) | [kW] | 0,39 | ||||
Rated current for cooling | [A] | 6,5 | ||||
Rated current for heating | [A] | 5,0 | ||||
Rated capacity for cooling (Rated - min - max) | Prated cooling | [kW] | 10,0 2,7 11,4 | |||
Rated capacity for heating (Rated - min - max) | Prated heating | [kW] | 11,1 2,8 12,7 | |||
Rated power input for cooling (Rated - min - max) | PEER | [kW] | 3,0 0,9 4,2 | |||
Rated power input for heating (Rated - min - max) | PCOP | [kW] | 3,0 0,8 4,0 | |||
Rated Energy efficiency ratio | EERrated | 3,29 | ||||
Rated Coefficient of performance | COPrated | 3,71 | ||||
Voltage - Frequency - Phase no. | [V-Hz-Ph] | 220/240 50 3 |
Important Notes
(1) Refrigerant Leakage and Global Warming: Refrigerant leakage contributes to climate change. Refrigerants with lower Global Warming Potential (GWP) have less impact on global warming than those with higher GWP if leaked into the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 675. This means that if 1 kg of this refrigerant fluid were leaked to the atmosphere, the impact on global warming would be 675 times higher than 1 kg of CO2 over a period of 100 years. Never attempt to interfere with the refrigerant circuit yourself, disassemble the product, or perform repairs without consulting a professional.
(2) & (3) Energy Consumption: The stated annual electricity consumption is based on standard test results. Actual energy consumption will vary depending on how the appliance is used and its installation location.