Amana Dryer Dimension Guide
Brand: Amana
Models: YNED4655EW (Electric), NED4655EW (Electric), NGD4655EW (Gas)
Capacity: 6.5 cu. ft.
Features: Wrinkle Prevent Option
Electrical Requirements
Fuel Type | Electric | Gas |
---|---|---|
Minimum Circuit Amperage Rating | 30 A | 15 A |
Maximum AMP Draw | 26 A (24 A Canada) | 6 A |
Operating Voltage | 240 V AC only (230 V AC Canada) | 120 V AC only |
Operating Frequency | 60 Hz |
Product Dimensions
The following tables detail the physical dimensions of the Amana dryers.
Main Dimensions
Diagram Description: Front view of the dryer showing overall height (A) and width (B). Side view showing overall depth (D) and top height (C).
Label | Description | Inches (min) | Millimeters (min) | Inches (max) | Millimeters (max) |
---|---|---|---|---|---|
A | Height (With leveling legs not extended) | 4211⁄16 | 1085 | 431⁄2 | 1104 |
B | Width | 29 | 737 | - | - |
C | Top Height (with min. feet) | 355⁄16 | 896 | 361⁄8 | 918 |
D | Depth | 283⁄8 | 722 | - | - |
Detailed Dimensions
Diagram Description: Side view illustrating depth with the door open (E). Rear view indicating clearances and connection points: F (Strain Relief from Side), G (Strain Relief Height), F/G (Power Cord from Side/Height for Canadian/Electric), I/J (Power Cord from Side/Height for Gas), K (Gas Valve Height), L (Gas Valve from Side), M (Exhaust Duct Height), N (Exhaust Duct from Side).
Label | Description | Inches (min) | Millimeters (min) | Inches (max) | Millimeters (max) |
---|---|---|---|---|---|
E | Depth with Door Open | 5011⁄16 | 1288 | - | - |
F | Strain Relief from Side (electric) | 1513⁄16 | 400 | - | - |
G | Strain Relief Height (electric) | 28 | 710 | 2813⁄16 | 732 |
F | Power Cord from Side (Canadian) | 1513⁄16 | 400 | - | - |
G | Power Cord Height (Canadian) | 28 | 710 | 2813⁄16 | 732 |
Power Cord Length (Canadian) | 523⁄8 | 1330 | - | - | |
I | Power Cord from Side (gas) | 1413⁄16 | 375 | - | - |
J | Power Cord Height (gas) | 323⁄16 | 818 | 331⁄8 | 840 |
Power Cord Length (gas) | 573⁄4 | 1467 | - | - | |
K | Gas Valve Height | 15⁄8 | 40 | 23⁄8 | 61 |
L | Gas Valve from Side | 93⁄16 | 234 | - | - |
M | Exhaust Duct Height | 47⁄8 | 125 | 513⁄16 | 146 |
N | Exhaust Duct from Side | 143⁄8 | 366 | - | - |
Spacing for Recessed Area or Closet Installation
The dimensions shown are for the recommended spacing allowed. Additional spacing should be considered for ease of installation and servicing. Additional clearances might be required for wall, door, and floor moldings. Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer.
For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable. Companion appliance spacing should also be considered.
Diagram Description: Illustrates required clearances for recessed or closet installation. Shows a maximum height clearance of 14 inches (356 mm) above the dryer, a front clearance of 18 inches (460 mm), and side clearances of 1 inch (25 mm) or more. For closet installations with doors, it indicates required ventilation openings: 48 square inches (310 cm²) at the top and 24 square inches (155 cm²) at the bottom of the door. Specific minimum/recommended clearances are noted as 6 inches/4 inches (152 mm/102 mm) and 1 inch/0 inches (25 mm/0 mm).