User Guide for UBIQUITI NETWORKS models including: PBE-M5-400, PowerBeam M5 25dBi High-Performance AirMax Bridge, PBE-M5-400 PowerBeam M5 25dBi High-Performance AirMax Bridge

PBE-M5-400 Quick Start Guide - iVolta.pl

The PowerBeam mounted outdoors without the Reflector installed provides outdoor-to- indoor coverage using the 3 dBi Antenna Feed only. PBE-M5-400 Quick Start ...

Package Contents Installation Requirements Hardware Overview


File Info : application/pdf, 11 Pages, 1.15MB

PDF preview unavailable. Download the PDF instead.

PBE-M5-400 Quick Start Guide
PBE-M5-400 Quick Start Guide
Package Contents

Reflector

Antenna Feed*

Rear Housing

Mounting Bracket

Pole Clamp

U-Bolt

Flange Nuts (Qty. 2)

Gigabit PoE (24V, 0.5A) with Mounting Bracket

Power Cord

* The PBE-M5-400 Antenna Feed has a thin gray ring around the center of the cap to differentiate it from the PBE-M5-300 Antenna Feed.
Installation Requirements
13 mm wrench Shielded Category 5 (or above) cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of the PoE. We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial-grade, shielded Ethernet cable from Ubiquiti. For more details, visit ui.com/toughcable
Hardware Overview

PBE-M5-400 Quick Start Guide
Ethernet This Gigabit Ethernet port is used to connect the power and should be connected to the LAN and DHCP server.
Reset Button To reset to factory defaults, press and hold the Reset button for more than 10 seconds while the device is powered on. Alternatively, the device may be reset remotely via a Reset button located on the bottom of the Gigabit PoE adapter.
Release Button After you assemble the device, check the Release button; it should be fully engaged in the Release Button Slot of the Rear Housing. This ensures that the Antenna Feed is locked into place. If you need to remove the Antenna Feed, you must depress the Release button first.
Signal LEDs In airOS®, you can modify the threshold values for the wireless signal strength LEDs on the Advanced tab under Signal LED Thresholds. The default values are shown below:
Ethernet LED The Ethernet LED will light steady green when an active Ethernet connection is made and flash when there is activity.
Power LED The Power LED will light green when the device is connected to a power source.
Application Examples
The PowerBeam mounted outdoors with the Reflector installed provides directional outdoor coverage (gain is reflector-dependent).
The PowerBeam mounted outdoors without the Reflector installed provides outdoor-toindoor coverage using the 3 dBi Antenna Feed only.

PBE-M5-400 Quick Start Guide
Installation
1. 2.
3.

PBE-M5-400 Quick Start Guide 4. 5. 6.

PBE-M5-400 Quick Start Guide 7.
Optional (radome not included)

PBE-M5-400 Quick Start Guide
Connecting Power
WARNING: The switch port must comply with the power specifications listed in this Quick Start Guide.
OR Optional
Accessing airOS

Verify connectivity in the airPOBSEC-Mon5fi-g4u0r0atQionuicInkteSrftaacrteG. uide 1. Make sure that your host system is connected via Ethernet to the device. 2. Configure the Ethernet adapter on your host system with a static IP address on the
192.168.1.x subnet. 3. Launch your web browser and type https://192.168.1.20 in the address field. Press
enter (PC) or return (Mac).
4. Enter ubnt in the Username and Password fields. Select your Country and Language. You must agree to the Terms of Use to use the product. Click Login.
The airOS Configuration Interface will appear, allowing you to customize your settings as needed. For details, refer to the User Guide available at ui.com/download/airmax You can also manage your device using the Ubiquiti® Network Management System. Setup using the UNMSTM app requires the U-Installer, sold separately.
Installer Compliance Responsibility
Devices must be professionally installed and it is the professional installer's responsibility to make sure the device is operated within local country regulatory requirements.
Antenna
Select your antenna from the list. If Calculate EIRP Limit is enabled, transmit output power is automatically adjusted to comply with the regulations of the applicable country. Note the requirements and antenna types listed below.
Cable Loss (When applicable)
Enter the cable loss in dB. Output power is adjusted to compensate for loss between the radio and the antenna.
Certified Antenna Types

This radio transmitter FCC IPDB: ES-WMX5--P4B0E05QMui/cIkC:S6ta5r4t5GAu-PidBeE5M has been approved by FCC / ISED Canada to operate with the antenna types listed below with the maximum permissible gain for each antenna type indicated. Antenna types not included in this list or having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.

Antenna

Frequency

Gain

Dish

5 GHz

25 dBi

Specifications
Dimensions
Weight (Mount Included)
Gain Networking Interface Enclosure Max. Power Consumption Max. TX Power Power Supply Power Method Wind Survivability
Wind Loading
Mounting Salt Fog Test
Vibration Test Temperature Shock Test UV Test
Wind-Driven Rain Test
Operating Temperature Operating Humidity Certifications
Worldwide US/CA

PBE-M5-400 420 x 420 x 275 mm
(16.54 x 16.54 x 10.83") 1.753 kg (4.789 lb) 25 dBi
(1) 10/100/1000 Ethernet Port Outdoor UV Stabilized Plastic
8W 26 dBm 24V, 0.5A Gigabit PoE Adapter (Included) Passive PoE (Pairs 4, 5+; 7, 8 Return) 200 km/h (125 mph) 342.5 N @ 200 km/h (77 lbf @ 125 mph) Pole Mounting Kit Included IEC 68-2-11 (ASTM B117), Equivalent: MIL-STD-810 G Method 509.5 IEC 68-2-6 IEC 68-2-14 IEC 68-2-5 at 40° C (104° F) Equivalent: ETS 300 019-1-4 ETS 300 019-1-4 Equivalent: MIL-STD-810 G Method 506.5 -40 to 70° C (-40 to 158° F) 5 to 95% Noncondensing CE, FCC, IC

Operating Frequency (MHz)
U-NII-1 U-NII-2A U-NII-2C U-NII-3

5150 - 5875 5150 - 5250 5250 - 5350 5470 - 5725 5725 - 5850

Safety Notices
1. Read, follow, and keep these instructions. 2. Heed all warnings. 3. Only use attachments/accessories specified by the manufacturer.
WARNING: Do not use this product in location that can be submerged by water.

WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.

Electrical Safety Information

1. Conomthpelimanacneuifsacretuqrueirr'esdlawbiethl.PrCeBosnEpne-ecMtctt5ioo-n4vo0tolt0aagQed,uifffiercerkeqnuStetpnaocrywt,eGarnusdoidcuuercrreetnhtarneqthuoirseemsepnetsciifnieddicmataeyd
result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed. 2. There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician. 3. This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet. a. Do not substitute the power cord with one that is not the provided approved type. Never use
an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire. b. The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death. c. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment. d. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection. e. Protective bonding must be installed in accordance with local national wiring rules and regulations.
Limited Warranty
ui.com/support/warranty
The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where applicable, specify arbitration instead of jury trials or class actions.
Compliance
FCC
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions. 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause
undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This radio transmitter has been approved by FCC.
ISED Canada
CAN ICES-3(A)/NMB-3(A)
This device complies with ISED Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference, and 2. This device must accept any interference, including interference that may cause undesired
operation of the device. This radio transmitter has been approved by ISED Canada.
The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems.
CAN ICES-3(A)/NMB-3(A)
Le présent appareil est conforme aux CNR d'ISDE Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : 1. l'appareil ne doit pas produire de brouillage; 2. l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible
d'en compromettre le fonctionnement. Le présent émetteur radio a été approuvé par ISDE Canada.
Les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour une utilisation à l'intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux.
IMPORTANT NOTE
Radiation Exposure Statement

This equipment environment.

complies

witPhBraEd-iaMtio5n-4e0x0poQsuureiclkimSitstasrettGfourtihdefor

an

uncontrolled

This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body.

This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

AVIS IMPORTANT

Déclaration sur l'exposition aux rayonnements
Cet équipement est conforme aux limites prévues pour l'exposition aux rayonnements dans un environnement non contrôlé. Lors de l'installation et de la mise en fonctionnement de l'équipement, assurez-vous qu'il y ait une distance minimale de 20 cm entre l'élément rayonnant et vous. Cet émetteur ne doit être installé à proximité d'aucune autre antenne ni d'aucun autre émetteur, et ne doit être utilisé conjointement à aucun autre de ces appareils.
Australia and New Zealand
Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference.

Brazil
Nota: Este equipamento não tem direito à proteção contra interferência prejudicial e não pode causar interferência em sistemas devidamente autorizados.

CE Marking
CE marking on this product represents the product is in compliance with all directives that are applicable to it.

Country List AT BE BG CY CZ DE DK EE EL ES FI FR HR HU IE IT LV LT LU MT NL PL PT RO SE SI SK UK
BFWA (Broadband Fixed Wireless Access) members noted in blue
Note: This device meets Max. TX power limit per ETSI regulations.
The following apply to products that operate in the 5 GHz frequency range: Note: This device is restricted to indoor use only when operating in the 5150 - 5350 MHz frequency range within all member states.
Note: Operation in the 5.8 GHz frequency band is prohibited in BFWA member states. Other countries listed may use the 5.8 GHz frequency band.
WEEE Compliance Statement
Declaration of Conformity
Online Resources

PBE-M5-400 Quick Start Guide
© 2021 Ubiquiti Inc. All rights reserved.


Mozilla/5.0 (Windows NT 10.0; Win64; x64) AppleWebKit/537.36 (KHTML, like Gecko) Chrome/93.0.4577.82 Safari/537.36 Skia/PDF m93