AEMC Amperimetric Probes
Image of AEMC MR415, MR416, MR525, and MR526 Amperimetric Probes.
Series MR Amperimetric Probes
Models MR415, MR416, MR525, and MR526
Hall-effect and general-purpose amperimetric probes, for use with digital multimeters, data loggers, and power analyzers.
Specifications
MODEL | MR415 | MR416 | MR525 | MR526 |
---|---|---|---|---|
ELECTRICAL CHARACTERISTICS | ||||
Measurement Range | 0.5 to 400 ACA, 600 ACC | 0.5 to 40 ACA, 60 ACC; 0.5 to 400 ACA, 600 ACC | 0.5 to 1000 ACA, 1400 ACC | 0.5 to 100 ACA, 150 ACC; 0.5 to 1000 ACA, 1400 ACC |
Output Signal | 1 mV/A | 10 mV/A, 1 mV/A | 1 mV/A | 10 mV/A, 1 mV/A |
Frequency Range | DC to 30kHz (at -3 dB) (depends on current value) | |||
Phase Shift (at 50/60 Hz) | ≤1.5° at 400 A <2.2° at 40 A | ≤1.5° at 400 A <2.2° at 40 A | ≤1.5° at 400 A <2.2° at 40 A | ≤1.5° at 400 A <2.2° at 40 A |
Load Impedance | >1 MΩ and ≤100 pF | |||
Overload | 3000 ACC or 1000 ACA continuous at <1 kHz | |||
Zeroing | Automatic on all ranges | |||
Power Source | One 9V alkaline battery or 5 VDC with micro USB Type B | |||
Battery Life | 50 hours typical | |||
Low Battery Indicator | Green LED flashing | |||
Overload Indicator | Red LED flashing (indicates measurement exceeds selected range) | |||
Output Terminal | 1.5 m (5 ft) cable with double insulation and two 4 mm safety banana terminals | |||
MECHANICAL CHARACTERISTICS | ||||
Max. conductor size | Cables: (1) 30 mm (1.18 in.) or (2) 24 mm (0.94 in.) Busbars: (1) 50 x 10 mm (1.97 x 0.39 in.) or (2) 31.5 x 10 mm (1.23 x 0.39 in.) or (3) 25 x 8 mm (0.98 x 0.31 in.) | Cables: (1) 39 mm (1.5 in.) or (2) 25.4 mm (1 in.) Busbars: (1) 50 x 12.5 mm (1.97 x 0.49 in.) or (2) 25 x 5 mm (0.98 x 0.2 in.) or (1) 31.5 x 10 mm (1.24 x 0.30 in.) or (3) 25 x 8 mm (0.98 x 0.31 in.) | ||
Dimensions | 224 x 97 x 44 mm (8.82 x 3.82 x 1.73 in.) | 236.5 x 97 x 44 mm (9.31 x 3.82 x 1.73 in.) | ||
Weight (with battery) | 440 g (0.98 lbs) | 520 g (1.15 lbs) | ||
ENVIRONMENTAL CHARACTERISTICS | ||||
Operating Temperature | -10 to 55°C (14° to 131°F) | |||
Storage Temperature | -40 to 80°C (-40° to 176°F) | |||
Relative Humidity | 0 to 85% with linear decrease above 35°C | |||
SAFETY | ||||
Protection | IP40 | |||
Electromagnetic Compatibility | EN 61326-1 | |||
Electrical Safety | IEC 61010-1, EN 61010-2-32, Pollution Degree 2, 600 V CAT III |
Key Features
- ? The clamp shape allows it to be placed around small cables or busbars.
- ? Battery powered or via an external 5V source using the micro USB connector.
- ⚡ Measurements up to 1000 ACA and 1400 ACC (model dependent).
- ⚙️ DC zeroing function.
- ⚙️ Auto-power-off function that can be enabled or disabled.
- ? Millivolt output compatible with most instruments.
- ? Battery life up to 50 hours.
- safety rating.
Catalog Numbers
CATALOG NUMBER | DESCRIPTION |
---|---|
1200.80 | Amperimetric probe CA/CC model MR415 (400 ACA/600 ACC, 1 mV/A, cable with 4 mm banana connectors) Replacement for model MR410 |
1200.82 | Amperimetric probe CA/CC model MR416 (40 ACA/60 ACC, 10 mV/A and 400 ACA/600 ACC, 1 mV/A, cable with 4 mm banana connectors) Replacement for model MR411 |
1200.81 | Amperimetric probe CA/CC model MR525 (1000 ACA/1400 ACA, 1 mV/A, cable with 4 mm banana connectors) Replacement for model MR520 |
1200.83 | Amperimetric probe CA/CC model MR526 (100 ACA/150 ACC, 10 mV/A and 1000 ACA/ 1400 ACC, 1 mV/A, cable with 4 mm banana connectors) Replacement for model MR521 |
General Use Amperimetric Probes (MN Series)
Image of various AEMC MN Series Amperimetric Probes.
SERIES | MODEL | RATIO | MEASUREMENT RANGE AC | DC | OUTPUT SIGNAL CURRENT | VOLTAGE | PHASE SHIFT** | MAX. CONDUCTOR SIZE CABLE | BUS BAR | OUTPUT CONNECTION | CATALOG NUMBER |
---|---|---|---|---|---|---|---|---|---|---|---|
MN01 | 2 to 150 A | 1 mA/A* | 10 mm (0.39 in.) | N/A | 2129.17 | ||||||
MN02 | 1000:1 | 50 mA to 100 A 50 mA to 90 A | 2129.20 | ||||||||
MN03 | 2 to 100 A | 1 mV/A | 2129.18 | ||||||||
MN05 | 5 MACA to 10 A 1 to 100 A | 1 mV/mA 1 mV/A | Cable | 2129.19 | |||||||
MN103 | 1 mA to 10 A 1 to 100 A | 1 mV/mA 1 mV/A | 1031.02 | ||||||||
MN106 | 1000:1 | 2 to 150 A | 1 mA/A | <10° | 12 mm (0.47 in.) | 1031.17 | |||||
MN114 | 1 mA to 10 A | 100 mV/A | <8° | 2110.71 | |||||||
MN185 | 50 mA to 120 A | 1 mA/A | <3.5° | Connector | 100.185 | ||||||
MN213 | 1000:1 | 0.5 to 240 A | 1 mA/A* | 2115.75 | |||||||
MN251 | 0.1 to 240 A | 1 mV/A | <2.5° | Cable | 2115.77 | ||||||
MN253 | 0.1 to 24 A 0.1 to 240 A | 10 mV/A 100 mV/A | N/A | 2115.79 | |||||||
MN255 | 10 mV/A | 2115.81 | |||||||||
MN291 | 0.5 to 240 A | 100 mV/A | N/A | 2115.84 | |||||||
MN307 | 10 mA to 12 A | 100 mV/A | 2116.23 | ||||||||
MN312 | 1000:1 | 0.1 to 200 A | 1 mA/A* | <2.5° | 19.8 mm (0.78 in.) | Connector | 2116.24 | ||||
MN313 | 1 mA/A* | Cable | 2116.25 | ||||||||
MN352 | 0.1 to 150 A | 10 mV/A | Connector | 2116.26 | |||||||
MN353 | 0.01 to 2.4 A 0.1 to 200 A | 1000 mV/A 10 mV/A | <3° | 2116.27 | |||||||
MN373 | 2116.28 | ||||||||||
MN375 | 0.1 to 10 A | 100 mV/A | <1.5° | 2115.41 | |||||||
MN379 | 5mA to 6 A 0.1 to 120 A | 200 mV/A 10 mV/A | Cable | 2153.01 | |||||||
SL206 | 10 mA to 1.5 A 50 mA to 60 A | 10 mA to 2 A 50 mA to 80 A | 1 mV/mACA/CC 10 mV/ACA/CC | <1° | 11.8 mm (0.46 in.) | 1201.45 | |||||
MD301 | 1000:1 | 2 to 500 A | 1 mVcc/ACA | N/A | 30 mm (1.18 in.) | 63 x 5 mm (2.48 x 0.20 in.) | 1201.07 | ||||
MD305 | 1 to 600 A | 1 mA/A* | <1° | 2 x 500 kcmil | 1201.36 |
*Protection for open secondary output
**Phase shift indicated at maximum load
Notes: MN103, MN106, MN114, and MN185 models are not CE marked. Probes from the MN200 and MN300 series have UL certification except for model MN379. Consult factory for NIST calibration pricing.
AmpFlex® and Miniflex® Probes
Image of AEMC AmpFlex and Miniflex probes.
SERIES | MODEL | INDEX | MEASUREMENT RANGE AC | DC | OUTPUT SIGNAL CURRENT | VOLTAGE | PHASE SHIFT** | MAX. CONDUCTOR SIZE CABLE | BUS BAR | OUTPUT CONNECTION | CATALOG NUMBER |
---|---|---|---|---|---|---|---|---|---|---|---|
MF 300-6-2-10-HF | 30 A / 300 A | 100 mV/A / 10 mV/A | 70 mm (2.95 in.) | 2126.84 | |||||||
MF 300-10-2-10-HF | 45 mm (1.77 in.) | 2126.83 | |||||||||
MA114 | 3 A / 30 A / 300 A / 3000 A | 1 mV/mA / 100 mV/A 10 mV/A / 1 mV/A | 101 mm (4 in.) | 2153.41 | |||||||
300-24-2-10 | 30 A / 300 A | 100 mV/A / 10 mV/A | 190 mm (8 in.) | 2112.88 | |||||||
1000-24-1-1 | 1000 A | 1 mV/A | 2112.39 | ||||||||
1000-24-2-1 | 100 A / 1000 A | 10 mV/A / 1 mV/A | 290 mm (11 in.) | 2129.98 | |||||||
1000-36-2-1 | 2113.00 | ||||||||||
3000-24-1-1 | 3000 A | 1 mV/A | 190 mm (8 in.) | 2112.46 | |||||||
3000-36-1-1 | 290 mm (11 in.) | 2112.48 | |||||||||
3000-24-2-1 | 300 A | 10 mV/A | 190 mm (8 in.) | 2113.05 | |||||||
3000-36-2-1 | 3000 A | 1 mV/A | 290 mm (11 in.) | 2112.00 | |||||||
3000-48-2-1 | 390 mm (15 in.) | 2112.01 | |||||||||
6000-36-2-0.1 | 600 A / 6000 A | 1 mV/A / 0.1 mV/A | 290 mm (11 in.) | 2113.21 | |||||||
30000-24-2-0.1 | 3000 A / 30000 A | 2113.33 | |||||||||
24-3001 | 300 ACA / 3000 ACA | 10 mV/A / 1 mV/A (4000 mV peak max.) | 190 mm (8 in.) | 2120.81 |
Note: Consult factory for calibration pricing.
Oscilloscope Probes with BNC Connectors
Image of AEMC Oscilloscope Probes with BNC connectors.
MODEL | MEASUREMENT RANGE AC | DC | OUTPUT SIGNAL VOLTAGE | PHASE SHIFT** | MAX. CONDUCTOR SIZE CABLE | BUS BAR | OUTPUT CONNECTION |
---|---|---|---|---|---|---|---|
SL261 | 100 mA to 10 A 1 to 100 A | 100 mV/A 10 mV/A | <1.5° | 11.8 mm (0.46 in.) | N/A | 2 m (6.6 ft) cable with BNC | |
MN261 | 0.1 to 24 A 0.5 to 240 A | 100 mV/A 10 mV/A | <2.5° | 19.8 mm (0.78 in.) | |||
SR661 | 0.1 to 12 A 0.1 to 120 A 1 to 1200 A | — | 100 mV/A 10 mV/A 1 mV/A | <1° | 52 mm (2.05 in.) | 50 x 5 mm (1.96 x 0.19 in.) | |
MN251T | 0.5 to 240 A | 1 mV/A | <2.5° | 20 mm (0.78 in.) | 20 mm (0.78 in.) | 3 m (10 ft) cable with BNC | |
MN379T | 0.005 to 6 A 0.1 to 120 A | 200 mV/A 10 mV/A | <4° <2° | ||||
MH60 | 0.5 to 100 A | 10 mV/A | <1° | 26 mm (1.02 in.) | N/A | ||
MR417 | 0.5 to 40 A 0.5 to 400 A | 0.5 to 60 A 0.5 to 600 A | 10 mV/A 1 mV/A | <2.2° <1.5° | 30 mm (1.18 in.) | 2 busbars of 31.5 x 10 mm (1.24 x 0.39 in.) | 2 m (6.6 ft) cable with BNC |
MR527 | 0.5 to 100 A 0.5 to 1000 A | 0.5 to 150 A 0.5 to 1400 A | 39 mm (1.53 in.) | 2 busbars of 50 x 5 mm (1.96 x 0.19 in.) |
*Phase shift indicated at maximum load.
Note: All probes comply with 600 V CAT III safety rating and CE marking. Not all models have UL certification; please consult factory.
Output Terminals
Images illustrating different output terminal types.
Cable with BNC
2 m (6.5 ft) coaxial cable with a BNC connector, rated for 600 Vrms.
Connectors
Standard 4 mm safety banana connectors.
Cables
Reinforced 1.5 m (5 ft) cable with 4 mm banana terminals.
Protected Banana Terminals
Two 4 mm banana terminals with standard 19 mm (3/4 in.) spacing.
Safety and Certifications
All probes comply with the
safety rating and marking. Not all models have certification; please consult factory for details.