VARIABLE SPEED PUMP 2.2HP 230V 2 INCH

SKU: 75409

INSTALLATION AND USER'S GUIDE

IMPORTANT SAFETY INSTRUCTIONS

This guide provides instructions for installing and using the VARIABLE SPEED PUMP. If you have any questions about the equipment, please contact XtremepowerUS.

This guide contains important information about safely installing and operating this product. After installation, make sure to share this information with the owner/operator or leave it with them for their reference.

Legends and Symbols

❗ DANGER: Ignoring these hazards can result in death, severe personal injury, or significant property damage.

⚠️ WARNING: Indicates potential hazards that can result in severe personal injury, death, or significant property damage. Ignoring these warnings presents a real danger.

? CAUTION: Indicates potential hazards that can result in minor or moderate personal injury, property damage, or actions that are unpredictable and unsafe. Ignoring these cautions presents a potential hazard.

ℹ️ NOTICE: This label indicates important special instructions that are not directly related to hazards.

ATTENTION INSTALLER: This manual contains vital information regarding the installation, operation, and safe use of this product. It is essential to provide this manual to the end user of the product. Failure to read and follow all instructions could lead to severe injuries.

❗ DANGER: Failure to comply with all instructions and warnings may lead to severe bodily injury or even death. For optimal safety and functionality, it is advisable to have the product installed and serviced by a certified service professional. Prior to using this product, installers, operators, and owners must carefully review these warnings and all instructions provided in the owner's manual. It is essential to leave these warnings and the owner's manual with the owner for their reference and safety.

⚠️ WARNING: For safety reasons, children should not be allowed to use this product. Packing materials and plastic bags are not toys. Keep them away from children to prevent the risk of suffocation.

❗ DANGER - Suction Entrapment Risk: High suction can trap and drown individuals near drains or broken covers. Avoid using the pool or spa if drain covers are missing, cracked, or damaged.

❗ DANGER - Electrical Hazard: Never open the pump's drive or motor enclosure to avoid electrical hazards.

⚠️ WARNING - Qualified Installation: Pool pump installation and servicing should only be performed by a qualified pool service professional.

⚠️ WARNING - Correct Application: Avoid using the pump in settings for which it was not designed, as improper usage can lead to injury or death.

⚠️ WARNING - Adult Supervision: This product is not suitable for use by children without adult supervision.

⚠️ WARNING - Ensure Safe Operation: Only install the pump in applications that match its intended design.

⚠️ WARNING - High-Pressure Hazard: Pool circulation systems operate under high pressure, which can lead to serious injury if improperly handled.

⚠️ WARNING - Start-Up Precautions: Stand clear of the system during start-up to avoid potential hazards from pressure surges.

? CAUTION - System Sizing and Installation: Ensure that pumps are properly sized and installed to avoid injury, system damage, or compromised performance.

? CAUTION - Suction Entrapment Hazard: Stay off the main drain and away from suction outlets. Ensure properly installed and secured anti-entrapment covers are in place to prevent hazards. Maintain distance from main drains and suction outlets. If possible, disable suction outlets or convert them to return inlets. All suction plumbing installations must comply with national and local codes.

ℹ️ NOTE - Intended Use: This pump is for permanent swimming pools and compatible hot tubs or spas. It is not for use with storable pools.

ℹ️ NOTE - Manual and Label Adherence: Review the product manual for important operation and maintenance guidelines.

ℹ️ NOTE - Safe Electrical Setup: Electrical installations must allow for safe operation without exposing users to electrical risks.

ℹ️ NOTE - Safety Labels: Maintain safety labels in good condition for clear visibility of hazards and replaced if damaged.

ℹ️ NOTE - Air Relief: Before starting the system, open the air relief valve and confirm all system valves are open to avoid pressure buildup.

OVERVIEW (PRODUCT INFORMATION)

PRODUCT INTRODUCTION

This pump boasts a variable frequency drive that ensures premium efficiency, allowing for flexible adjustments in motor speed and operation duration. Capable of functioning across a broad speed spectrum of 1000 to 3450 RPM, it is also designed to work with 230 VRMS nominal voltage at both 50HZ and 60HZ frequencies. Engineered to prioritize energy conservation, the pump maintains cleanliness at the lowest necessary speeds, with optimal settings being influenced by pool dimensions, additional water features, sanitation chemicals used, and environmental conditions. Determining the most energy-efficient settings may require a period of trial and optimization.

KEY FEATURES

DRIVE

PUMP

MOTOR

SPECIFICATION

SKU Power Connection Electrical Requirements Maximum Power Consumption Maximum Shaft Horsepower Maximum Current Maximum Flow Rate Per Minute Maximum Head Lift Speed Range Hydraulic Horsepower (HHP) Total Horsepower (THP) Protection Rating Storage Temperature Range Operating Temperature Range Humidity Tolerance
75409 2" Inlet/Outlet 230V, 50/60HZ 1800 W 2.2 HP 7.8 AMPS 131 GPM (Gallons Per Minute) 81.4 FT 1000 ~ 3450 RPM (Revolutions Per Minute) 1.138 2.20 IPX 5 (Water Resistant) -40°F ~ 140°F 32°F ~ 122°F 0% ~ 95% Relative Humidity, Non-Condensing

DIMENSIONS

Approximate dimensions: Height 22.6 inches (574mm), Width 11.3 inches (288mm), Depth 10.2 inches (258mm). Other measurements include: 13.7" (347mm) length, 10.3" (262mm) width, 6.3" (159mm) depth, 12.9" (328mm) length, 9.1" (232mm) depth, 7.6" (194mm) height, 8.9" (225mm) depth.

INSTALLATION

Installation should be performed only by a qualified plumbing professional to ensure proper setup and to mitigate safety risks. Refer to the IMPORTANT SAFETY INSTRUCTIONS on pages 1-3 for detailed safety and installation guidance.

LOCATION

ℹ️ NOTE: Do not install the pump in an enclosed space, such as an external enclosure or under a hot tub or spa skirt. Ensure that the pump is securely attached to a stable equipment pad for optimal performance.

LOCATION REQUIREMENTS

Diagram Description (Figure 1): Shows required clearance around the pump: 3 inches minimum at the rear for motor removal and 5 inches minimum on top for keypad accessibility.

PIPING

PIPING GUIDELINES

Diagram Description (Figure 2): Illustrates optimal piping setup. It shows a straight section of pipe at least five times the suction pipe's diameter before the pump's inlet to reduce turbulence and improve priming. Avoid placing 90° elbows directly at the suction port.

FITTINGS AND VALVES

ℹ️ NOTE: To reduce turbulence and prevent cavitation, avoid placing 90° elbows directly at the pump's suction port.

ELECTRICAL INSTALLATION

⚠️ WARNING: Risk of Electrical Shock or Electrocution: It is strongly recommended that a certified electrician or qualified professional install this pump in accordance with the National Electrical Code and local regulations to mitigate the risk of serious injury, death, or property damage. Always disconnect power at the circuit breaker before servicing to prevent electric shock or injury. Read all instructions carefully before servicing the pump.

ℹ️ NOTE: The pump is designed to operate with a 230 V single-phase input, compatible with both 50 and 60 Hz. Its power connections support up to 8 AWG solid or stranded wire.

WIRING INSTRUCTIONS

ℹ️ NOTE: Take care not to pinch wires when securing the drive body and lid.

GROUNDING INSTRUCTIONS

Ensure the motor is permanently grounded using the Grounding Terminal located in the drive's wiring compartment. Comply with the National Electrical Code and local regulations regarding the grounding wire's size and type. Attach the ground wire to the electrical service's ground.

BONDING INSTRUCTIONS

Connect the motor to the pool's structural metal components, electrical systems, and metal conduits and piping within 5 feet of the pool or spa's inner walls using the provided bonding lug on the motor's side. Comply with the current National Electrical Code and local codes for bonding practices. A solid copper conductor of at least 8 AWG is required for bonding. For installations in Canada, a 6 AWG or thicker solid copper conductor is necessary.

Diagram Description (Figure 3): Shows electrical connections. L1/L and L2/N terminals for power input, and a GND terminal for grounding. It also indicates a bonding lug on the motor's side for connecting to pool's structural metal components.

OPERATION

INITIAL SETUP

Before initial use of the pump, program its internal clock and operational schedules. Instructions for setting the clock are available under SETTING THE CLOCK and USING THE DEFAULT SCHEDULE. For custom schedule programming, see CUSTOM SCHEDULE PROGRAMMING.

The drive keypad allows programming and control of the pump and provides access to all features and settings.

ℹ️ NOTE: The pump's functionality may vary if features like External Control Only Mode or Keypad Lockout are enabled.

? CAUTION: To avoid damaging the keypad, use only your fingers to press the buttons; do not use screwdrivers, pens, or other tools for programming the pump.

⚠️ WARNING: If the pump motor is connected to power, pressing any buttons mentioned in this section may activate the motor. Unexpected motor start-ups could result in personal injury or equipment damage. Always be aware of the motor's power status when programming or servicing.

KEYPAD FUNCTIONS

Diagram Description (Figure 4): Depicts the pump's control keypad. It includes numbered speed buttons (1-4), a Quick Clean button, Start/Stop button, Main Menu Access button, Display button, Arrow Keys (Up, Down, Left), a Digital Display, Display Mode LED Indicator, and Power LED Indicator. Each button's function is described:

INITIAL PROGRAMMING

Before first use, set the pump's internal clock and operational schedules. Ensure that the start times for Speeds 1 through 4 are programmed in chronological order within a 24-hour period.

SETTING THE CLOCK

When the pump is first connected to power, the clock will flash, indicating the need for setup. Press 'Setting'. Use the '+' and '-' buttons to set the current time, and '<' and '>' to adjust the cursor position. AM/PM will be displayed in 12-hour format.

USING THE DEFAULT SCHEDULE

The default schedule provides adequate daily circulation for most pools. The default operating cycle runs for 22 hours per day.

Default Schedule
PROGRAM STARTUP TIME OPERATION DURATION DEFAULT SPEED
SPEED 1: 8:00 AM (ADJUSTABLE) 2 HRS (ADJUSTABLE) 2850 RPM (ADJUSTABLE)
SPEED 2: 10:00 AM (ADJUSTABLE) 10 HRS (ADJUSTABLE) 1730 RPM (ADJUSTABLE)
SPEED 3: 8:00 PM (20:00) (ADJUSTABLE) 2 HRS (ADJUSTABLE) 2300 RPM (ADJUSTABLE)
SPEED 4: 10:00 PM (22:00) (ADJUSTABLE) 8 HRS (ADJUSTABLE) 1150 RPM (ADJUSTABLE)

Default Schedule Operation: SPEED 1 starts at 8:00 AM for 2 hours. SPEED 2 starts at 10:00 AM for 10 hours. SPEED 3 starts at 8:00 PM for 2 hours. SPEED 4 starts at 10:00 PM for 8 hours. Following SPEED 4, the pump pauses for 2 hours and then resumes with SPEED 1. This cycle repeats, maintaining a 22-hour daily operation.

ℹ️ NOTE: To start the pump, press the Start/Stop button and ensure that the corresponding LED is illuminated.

CUSTOM SCHEDULE PROGRAMMING

Ensure the pump is halted (Start/Stop LED off) before customizing. A blinking LED next to a parameter indicates it is in programming mode.

  1. Press Start/Stop to stop the pump.
  2. Press '1' to edit Speed 1; its LED and 'Speed' will blink. Adjust the Speed 1 RPM using the '+' and '-' buttons, and move the cursor with '<' and '>'. Speed adjusts in 100/10/1 RPM increments.
  3. Press '1' again to set the start time for Speed 1; 'Time' will blink. Set the start time with '+' and '-' buttons, adjusting the cursor with '<' and '>'. Adjust time in increments of 1 hour/10 minutes/1 minute.
  4. Press '1' again to set the duration for Speed 1; 'Duration' will blink. Set the duration using '+' and '-' buttons, and adjust the cursor with '<' and '>'. Duration adjusts in increments of 1 hour and 10 minutes. If set to 0, the pump will skip this segment.
  5. Confirm Speed 1 setup. Subsequent presses of '1' cycle through settings, saving changes automatically.
  6. To set Speed 2, press '2' and follow the same steps as for Speed 1 (adjust RPM, time, duration).
  7. Follow steps for Speed 2 to set Speed 3 and Speed 4.
  8. To set Quick Clean settings, follow similar steps using the Quick Clean button.
  9. To activate the pump with the new schedule, press Start/Stop; the LED will light up. If the pump was manually stopped, press Start/Stop again to start the schedule. A lit Start/Stop LED indicates the pump will follow the set schedule.

SPEED PRIORITIZATION FOR SCHEDULING (WITHOUT EXTERNAL CONTROL)

When operating based on the internal schedule, programmed speeds follow a priority sequence from highest to lowest: SPEED 1, SPEED 2, SPEED 3, and SPEED 4. The prioritization order ensures that if timeframes overlap, the higher priority speed takes precedence.

Example: If SPEED 1 is scheduled from 8:00 AM to 2:00 PM, and SPEED 2 is scheduled from 9:00 AM to 10:00 AM, the pump will run in SPEED 1 mode from 8:00 AM to 2:00 PM, effectively skipping the scheduled time for SPEED 2 because it falls within the SPEED 1 period.

OPERATING THE PUMP IN ACTIVE MODE

? CAUTION: When the pump is powered, pressing any button may activate the motor, potentially causing personal injury or equipment damage. Always be aware of the motor's power status.

The Display button toggles through active settings: SPEED (current RPM), TIME (current time), DURATION (time left at current speed), and WATTS (current power usage). Pressing any Speed button (1, 2, 3, 4, or Quick Clean) during operation temporarily overrides the current setting. The pump will run at the selected speed for the preset duration, then resume the regular schedule. Changes made during operation apply only for the remaining duration of the active program and do not permanently save.

PROGRAMMING QUICK CLEAN

The pump includes a Quick Clean option for temporary operation at speeds ranging from 1700 to 3450 RPM. After a Quick Clean cycle, the pump reverts to its scheduled program.

  1. Stop the pump by pressing Start/Stop. Activate Quick Clean mode; the Quick Clean and 'Speed' LEDs will flash.
  2. Set the RPM using the '+' and '-' keys, and navigate with '<' and '>'. RPM can be adjusted in increments of 100, 10, or 1 RPM.
  3. Press Quick Clean again to set the duration; the 'Duration' LED will blink.
  4. Adjust the duration in hours and minutes using '+' and '-' keys, and navigate with '<' and '>'. Duration adjustments are available in increments of 1 hour or 10 minutes, with a range from 10 minutes to 24 hours. The Quick Clean duration setting will not affect the programmed start time of the regular schedule.

FACTORY RESET

To revert the drive to its default settings, perform a Factory Reset. This action erases all customized settings and schedules except for the current time of day. Confirm the necessity of this action before proceeding, as the reset takes immediate effect.

FACTORY RESET PROCESS

PRIMING

? CAUTION: The pump is pre-set to Priming mode, which causes it to automatically accelerate to 3200 RPM upon initial start-up.

Before activating the pump:

⚠️ WARNING: Never run the pump dry, as it will damage the shaft seal and cause leaks. Replace any damaged seal immediately. Maintain the proper water level in your pool (at least halfway up the skimmer opening) to prevent air from being drawn through the skimmer. A low water level can cause the pump to lose its prime, potentially leading to seal damage. Continuous operation with a compromised seal can damage the pump body and impeller, and may lead to personal injury and property damage.

STARTUP AND PRIMING PROCESS

At startup, the pump automatically begins a priming cycle, separate from any Quick Clean cycle. It starts at 2400 RPM and gradually increases to 3200 RPM over 5 minutes, with the drive displaying the time remaining.

ℹ️ NOTE: If the control system's priming timer is still running after the priming cycle, the pump will continue at the control system's set speed until the timer expires. The startup speed can be adjusted between 3200 RPM and 3450 RPM using the '+' and '-' buttons during boot-up.

ℹ️ NOTE: The initial boot begins with a 5-minute countdown. Press any Speed button (1 to 4) to exit the priming mode prematurely. Upon subsequent startups, the pump will assess the need for priming, taking approximately 20 seconds to determine if priming is required.

Priming duration may vary with local conditions, such as water temperature, atmospheric pressure, and pool water level. Test and adjust priming speeds as needed, allowing the system to drain between tests.

ℹ️ NOTE: To avoid air intake into the system, ensure the pump strainer pot is filled with water up to the bottom of the suction port.

MAINTENANCE

⚠️ WARNING - STRAINER POT HANDLING: Never open the strainer pot if the pump has failed to prime or has operated without water, as vapor pressure build-up may cause scalding water inside. Opening under these conditions can lead to severe injury. Ensure both suction and discharge valves are open, and verify that the strainer pot is cool before cautiously opening it.

⚠️ WARNING - POWER DISCONNECTION: Always turn off power at the circuit breaker and disconnect the digital input cable before servicing the pump. Failing to do so may result in fatal or severe electric shock injuries. Read and understand all service instructions prior to performing pump maintenance.

? CAUTION - PUMP MAINTENANCE: To prevent pump damage and maintain system efficiency, regularly clean the pump strainer and skimmer baskets.

CLEANING THE PUMP STRAINER BASKET

The strainer pot, located at the front of the pump, contains the strainer basket. Inspect the basket through the pot lid visually at least once a week. Regular cleaning ensures higher efficiency of the filter and heater and reduces stress on the pump motor.

CLEANING INSTRUCTIONS

ℹ️ NOTE: Keep the O-ring clean and lubricated.

ℹ️ NOTE: Ensure the O-ring is correctly placed to avoid pinching.

ℹ️ NOTE: Ensure the "Front" label on the lid faces the front of the pump.

MOTOR CARE

HEAT PROTECTION

DIRT PROTECTION

MOISTURE PROTECTION

⚠️ WARNING: HIGH-PRESSURE SYSTEM OPERATION: This system operates under high pressure, so servicing any component in the circulation system can introduce air, leading to pressurization. Such pressurized air may forcefully dislodge the lid, posing serious risks of injury, death, or property damage. To prevent these hazards, follow all provided instructions closely.

PUMP DISASSEMBLY AND REASSEMBLY

ℹ️ NOTE: For a detailed parts breakdown, refer to the REPLACEMENT PARTS section.

⚠️ WARNING - POWER DISCONNECTION: It is crucial to always shut off power at the circuit breaker before servicing the pump. Failing to disconnect the power source can result in potentially fatal electric shock injuries. Ensure you fully understand and comply with all servicing guidelines before beginning any maintenance work.

⚠️ WARNING - STRAINER POT HANDLING: Do not open the strainer pot if the pump is having trouble priming or has been operating without water, as these conditions can cause vapor pressure build-up with extremely hot water inside, posing a serious risk if opened. For safety, confirm that both the suction and discharge valves are open and that the strainer pot is cool to the touch before attempting to open it. Proceed with extreme caution.

REQUIRED TOOLS

PUMP DISASSEMBLY

PUMP REASSEMBLY

ℹ️ NOTE: The impeller screw has reverse threading.

ℹ️ NOTE: Tighten the through-bolts only after all bolts are finger-tightened, then secure to 110 in-lbs.

ℹ️ NOTE: Ensure the seal plate gasket is properly aligned.

PUMP RESTARTING

? CAUTION - Avoiding Dry Running: Never operate the pump without water, as dry running can damage the shaft seal, requiring immediate replacement. Maintain the proper water level in the pool, ideally at least halfway up the skimmer opening, to prevent air intake through the skimmer. A low water level can cause the pump to lose prime, leading to decreased pressure, potential pump damage, property damage, or even personal injury.

PUMP RESTARTING PREPARATION

If the pump is installed below the pool's water level, close the return and suction line valves before opening the strainer pot. Ensure these valves are reopened before starting the pump.

PUMP RESTARTING INSTRUCTIONS

ℹ️ NOTE: The lid is correctly locked when its handles are nearly perpendicular to the pump body.

WINTERIZING

Be proactive in anticipating freezing conditions, as freeze damage is not covered under warranty. In areas with mild climates where temporary freezing may occur, keep the filtering equipment running overnight to prevent freezing.

PREVENT FREEZE DAMAGE INSTRUCTIONS

ℹ️ NOTE: Avoid using plastic or airtight materials to cover the motor during winter storage. Ensure the motor remains uncovered if it will be operational or if the pump is expected to run.

TROUBLESHOOTING

⚠️ WARNING: ELECTRICAL SAFETY: Risk of Electrical Exposure: Diagnosis may require proximity to live components. Servicing should only be performed by certified professionals to prevent serious risks, including death, personal injury, or property damage.

ISSUE CAUSE CORRECTIVE ACTION
Pump Will Not Prime: Air in the suction line or pump Pump Failure Inspect the suction line and valves for any signs of damage or loose connections. Confirm the strainer pot lid is sealed correctly and the O-ring is intact. Check the pool's water level is adequate for the skimmer. Make sure the pump strainer pot is filled with water. Ensure that the suction line valve is operational and in the open position (if applicable). Ensure the pool water level is sufficient for the skimmer function.
Pump Will Not Prime: Insufficient water The Strainer Basket is Dirty or Full
Damaged Strainer Pot O-Ring
Air in the suction line or pump
Refer to Cleaning the Pump Strainer Basket section and clean the basket to remove debris. Examine the O-ring for wear or damage, and replace it if necessary. Check suction line and valves for any damage or loose connections. Check that the strainer pot lid is securely sealed and that the O-ring is present and correctly positioned. Ensure the pool's water level is at least halfway up the skimmer opening to support skimmer intake.
Reduced Pump Capacity and Head Clogged impeller
Dirty or full strainer basket
No power from the mains
Refer to Cleaning the Pump Strainer Basket section and clean the basket to remove debris. Refer to CLEANING THE PUMP STRAINER BASKET instruction. Inspect the circuit breaker and replace any blown fuses as needed. Check and secure connections to the mains wires.
Non-Starting Pump Voltage
Motor is jammed
Motor shaft is compromised
Use the Pump Disassembly instructions to manually rotate the motor shaft and clear any obstructions. The pump may require replacement.
Pump That Runs Then Stops Overheating (Over Temperature Fault)
Excessive current draw (Over Current Fault)
Check the motor fan cover located at the back of the motor for any accumulation of dirt and debris. Clean the fan cover using compressed air to remove any obstructions.
Noisy Pump Obstruction by debris in fan area
Full or dirty strainer basket
Improperly secured mounting
The impeller may be loose.
Check the fan cover located at the rear of the motor for any accumulation of dirt and debris. Use compressed air to clean if needed. Refer to CLEANING THE PUMP STRAINER BASKET instruction. Check and tighten all mounting bolts and pump bolts to ensure the pump is securely fastened. Verify that the fan at the rear of the pump is active. If it is, proceed to disassemble the pump as directed on page 22 and check that the impeller is properly fitted.
Pump Running Without Water Flow There could be air in the suction line or pump.
Plumbing may be clogged or restricted.
Examine the suction line and valves for any signs of damage or loose connections. Make sure the strainer pot lid is creating a proper seal and that the O-ring is present and correctly positioned. Confirm that the pool has an adequate water level for the skimmer to function effectively. Look for and eliminate any obstructions in the strainer pot or suction line. Check the discharge piping for any blockages, including partially closed valves or a dirty pool filter, and clear any obstructions.

ALARMS AND FAULT CODE GUIDANCE

When an alarm triggers, the drive will halt the pump and display a fault code. To reset, turn off the power and wait for all keypad LEDs to go off before restoring power. If the fault persists, consult the error description table below for troubleshooting.

FAULT CODE DESCRIPTIONS

SPECIFIC FAULTS

REPLACEMENT PARTS

The following is a list of common replacement parts for the 75409 Variable Speed Pump, referencing a parts diagram.

DISCLAIMER

The manufacturer and/or distributor have provided the parts list and assembly diagram in this manual for reference purposes only. They do not make any representation or warranty to the buyer that they are qualified to make repairs to the product or replace any parts of the product. In fact, the manufacturer and/or distributor expressly state that all repairs and parts replacements should be undertaken by certified and licensed technicians, and not by the buyer. The buyer assumes all risk and liability arising from their repairs to the original product or replacement parts or arising from their installation of replacement parts. It is strongly advised that qualified professionals handle any repairs or replacements to ensure safety and proper functioning of the product. Improper installation and operation may result in injury, property damage, or voiding of warranty. The manufacturer and/or distributor shall not be held responsible for any accidents, damages, or malfunctions resulting from the buyer's installation and operation of the product. It is essential to follow all safety guidelines and recommendations provided in this manual and to seek professional assistance if unsure about the installation or operation procedures.

CUSTOMER SERVICE AND TECHNICAL SUPPORT

If you have any questions about ordering pool pumps and replacement parts or pool products, please feel free to contact XtremepowerUS using the following contact information:

Phone: (909) 628-0880

Email: customer@xtremepowerusa.com

Hours of Operation: Monday – Friday, 9AM – 4PM (CST)

PDF preview unavailable. Download the PDF instead.

a6be333c-016b-4549-b896-b8d33f97453e Adobe PDF library 17.00

Related Documents

Preview XtremepowerUS 2HP 230V 2-Speed Inground Pool Pump Installation and User's Guide
Comprehensive installation, operation, maintenance, and troubleshooting guide for the XtremepowerUS 2HP 230V 2-Speed Inground Pool Pump (Item #75035). Includes safety instructions, specifications, and parts diagram.
Preview XtremepowerUS 75408 Variable Speed Pump 1.75 HP 230V Installation and User Guide
Comprehensive installation and user guide for the XtremepowerUS 75408 Variable Speed Pool Pump (1.75 HP, 230V). Covers safety instructions, product overview, installation, operation, maintenance, troubleshooting, and replacement parts for optimal pool circulation and energy efficiency.
Preview XtremepowerUS Variable Speed Pool Pump 3.0HP 230V 2-Inch Installation and User's Guide
Comprehensive installation, operation, maintenance, and troubleshooting guide for the XtremepowerUS 3.0HP 230V 2-Inch Variable Speed Pool Pump (SKU: 75410). Learn about safety, setup, programming, and parts.
Preview XtremepowerUS 1.5 HP Variable Speed Inground Pool Pump Owner's Manual and Safety Instructions
This manual provides installation and operation instructions for the XtremepowerUS 1.5 HP Variable Speed Inground Pool Pump (Item # 90166). It includes important safety warnings, precautions, assembly, operation, inspection, maintenance, and cleaning procedures.
Preview XtremepowerUS 1.5 HP 230V 2-Speed Inground Pool Pump Installation and User's Guide
Comprehensive installation and user's guide for the XtremepowerUS 1.5 HP 230V 2-Speed Inground Pool Pump (SKU: 75406). Covers safety instructions, installation, operation, maintenance, troubleshooting, and specifications.
Preview XtremepowerUS 1.5 HP 230V 2-Speed Inground Pool Pump Installation and User Guide
This guide provides detailed instructions for the installation, operation, maintenance, and troubleshooting of the XtremepowerUS 1.5 HP 230V 2-Speed Inground Pool Pump, model number 75034.
Preview XtremepowerUS 75172 Automatic & Manual Pool Cover Pump Assembly and User's Guide
Detailed assembly and user's guide for the XtremepowerUS 75172 1/2 HP Automatic & Manual Pool Cover Pump. Learn about installation, operation, maintenance, troubleshooting, and specifications for effective pool cover water removal.
Preview XtremepowerUS 75406 1.5 HP 230V 2-Speed Inground Pool Pump Installation and User's Guide
This guide provides essential information for the installation, operation, and maintenance of the XtremepowerUS 75406 1.5 HP 230V 2-Speed Inground Pool Pump. It covers safety warnings, setup procedures, troubleshooting tips, and specifications to ensure safe and efficient use.