This is the original instruction. Please read all manual instructions carefully before operating. VEVOR reserves clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won't inform you again if there is any technology or software updates on our product.
Safety Instructions
⚠️ For your safety and the safety of others, the following precautions must be observed when operating the sprayer:
- During spraying operation, personnel shall wear clothes in strict accordance with regulations, wear masks, glasses, hats, gloves, or protective clothing against pesticide penetration, and shall not work naked.
- It is strictly prohibited to spray toxic solutions such as pesticides on people or animals during use.
- Patients with mental illness or serious diseases, drunken people, and people without operation knowledge are prohibited from using this machine. People who have just taken strenuous exercise, have not had a good rest, or have insufficient sleep, as well as women in the period of lactation, should not be engaged in this work.
- The operator must wash all parts of the body and clean all kinds of clothing after use.
- When handling pesticides, follow the safety instructions provided by the pesticide manufacturer.
WARNING:
- Do not leave machines and tools or store them in unattended places. Turn off the power when not in use.
- Do not disassemble or change this machine.
- Operators must spray pesticides in front of the wind direction and shall not work under high temperature for a long time.
- Before each use of the battery (including the new machine), please charge the battery for 8-12 hours. When the battery is not charged, cover the charging base tightly to prevent water from getting wet.
- Try to avoid working without water to avoid damaging the diaphragm of the water pump.
- Before use, try spraying with clean water to check for water leakage at the base and good atomization effect. Only when everything is normal can you prepare liquid medicine for the operation.
- When adding liquid medicine, it must pass through the filter screen. If there are impurities, the normal use of the machine will be affected.
- If the liquid medicine overflows, please dry it immediately. Battery connectors, electrical components, and wire connectors shall not be exposed to liquid medicine to avoid corrosion.
- Please do not use non-water bath powder, because it cannot be dissolved into liquid. The suspended solids in the medicine tank will precipitate at the bottom, causing clogging of the filter screen and pipeline, thus affecting the pump's service life. The use of chemical liquids and special working fluids is prohibited.
- When the liquor spraying is completed, turn off the power switch or regulating switch first, and then release the injection switch after the pump stops working.
Model and Parameters
Model | KF-16C-48 |
---|---|
Capacity | 4 Gallons (16L) |
Pump | Membrane mini-pump |
Pressure Max. | 0-90psi |
Performance | c4.1±0.3L/min |
Charger | Input: 100-240V~ 50/60Hz 0.5A Output: DC12.0V, 1.6A |
Battery | Lithium Battery DC12V, 8Ah |
Structure Diagram
The sprayer consists of the following parts:
- 1. Spraying nozzle
- 2. Spray bar
- 3. Spray bar storage parts
- 4. Handle
- 5. Hose
- 6. Voltmeter
- 7. Charger socket
- 8. Switch
- 9. Pressure regulating knob
- 10. Straps
- 11. Battery compartment
- 12. Tank
- 13. Carrying handle
Assembly and Use
Step 1: Installation of spray bar kit
Connect one end of the hose (hexagon nut with sealing ring) to the water outlet of the barrel and the other end to the handle. Assemble the separated spray bar and connect it to the handle (adjustable fastener retractable spray bar). Select the appropriate nozzle and install it. Ensure sealing rings are added and tightened for all connections to prevent water leakage.
Step 2: Installation of pressure regulating knob
Press the knob cap in by hand.
Step 3: Installation of straps
Connect the chest fastener of the strap. Pass the strap through the strap hole at the back of the barrel, and hook the strap through the hole at the bottom.
Step 4: Filling and Operation
Fill the barrel with solution, add the sealing ring, and tighten the cover to prevent water leakage.
- Operation: Turn on the switch. "1" means to turn on the power, and "0" means to turn off the power.
- Voltmeter Description:
- Yellow light "L": The battery is insufficient and needs to be charged.
- Green light "N": Sufficient power, can be used normally.
- Red light "H": Abnormal. Stop using and eliminate the problem.
Step 5: Pressure Regulation
- Clockwise rotation increases the pressure; counter-clockwise rotation decreases or stops the pressure.
- Press and hold the handle to start working, and release to stop working. For prolonged spraying, the handle can be fixed on the ring of the handle.
Step 6: Cleaning After Use
Clean the sprayer with clean water. Turn off the governor and power supply after use.
Step 7: Charging
The red indicator of the charger indicates charging; the green light indicates that the battery is fully charged. Note: When charging, please turn off the power!
Introduction and Application of Nozzle
Model | Picture Description | Function Introduction | Note |
---|---|---|---|
KF-01D | Single-head copper nozzle | Provides a small amount of spray, or linear spray (15-20ft), only for telescopic spray bars. | The pressure knob must be adjusted to avoid intermittent operation of the motor pump when using. (It is normal if the indicator light does not flash or the motor pump works continuously.) |
KF-26E | Single-head plastic nozzle | Provides a small amount of spray, or linear spray (15-20ft). | The pressure knob must be adjusted to avoid intermittent operation of the motor pump when using. (It is normal if the indicator light does not flash or the motor pump works continuously.) |
KF-04D | Three-end copper nozzle | Provides a large amount of spray with a concentrated range. | |
KF-86E | Three-end plastic nozzle | Provides a large amount of spray with a long range. | |
KF-104E | Windproof nozzle | Equipped with a protective cover to reduce the impact of wind on spray. | |
KF-06E | F-type double nozzle | Provides medium spray effect. | |
KF-56E | Y-type double nozzle | Provides medium spray effect. | |
KF-23E | Fan-shaped nozzle | Provides 90°~110° plane fan-shaped spray, mostly used in scenes requiring controlled range, such as weeding. | The pressure knob must be adjusted to avoid intermittent operation of the motor pump when using. (It is normal if the indicator light does not flash or the motor pump works continuously.) |
Troubleshooting Instruction
Problem | Reasons | Solutions |
---|---|---|
The motor does not start after the power is turned on | The power connection wire falls off Battery is dead The power switch is off |
Check the connecting wire and plug the connector Use after charging Switch on |
The motor makes abnormal noise | The fixing screws of the water pump are loose | Check and tighten the screws of the fixing feet of the water pump |
Water leakage of substructure | Water inlet/outlet pipe of water pump is loose and cracked Spray bar shake Nozzle is worn or blocked Nozzle accessories are installed incorrectly The filter screen is blocked Connecting pipe leaks |
Open the base, check whether the internal water pipe is loose or broken, and tighten or replace it Reduce the pressure Replace the nozzle Install according to the correct installation method Clean the filter screen in bucket Tighten or replace the water pipe |
Poor atomization | Insufficient battery power Water pump blocked Nozzle clogging |
Charging (The voltmeter indicator light is...) Remove the nozzle and spray water with clean water for 5-10 minutes (the water output will increase and stabilize under normal conditions). If the water output does not increase after 10 minutes, it is recommended to replace the pump. Remove the nozzle for cleaning |
Water pump does not work | Water pump blocked Wiring problem/water pump damaged Charger cable open circuit |
Dismantle the water pump cover and remove foreign matters After eliminating the problems of electric wires and waterways, contact the merchant to purchase a new water pump, and replace the water pump under the guidance of the merchant. Contact the merchant, inform the product model, and purchase a new charger |
Unable to charge | The battery is broken (the charger indicator is green, but the spray cannot be used) The charger is broken (the charger indicator does not light up or the spray still cannot be used after charging for 10 minutes) |
Open the battery cover, take out the battery, and replace it with a good one. The black wire is connected to the "-" pole, and the red wire is connected to the "+" pole. (Note: Before removing the battery, please take a picture of the line with your mobile phone and install it back according to the original route to avoid mistakes). Contact the merchant, inform the product model, and purchase a new charger |
Cleaning, Care and Storage Rules
Cleaning and care:
After operating the sprayer, remove the working solution from the tank completely and rinse the tank, hose, pump, and spray tube with clean water. Finally, spray with clean water for 3 minutes to eliminate the possibility of a chemical reaction when other chemicals are used in the next spraying. Residues of chemicals can lead to corrosion and other damage to parts of the sprayer, especially spraying nozzles, filters, and seals.
Storage rules:
- Keep the sprayer in a dry, cool, and out-of-way place for children.
- It is forbidden to store the sprayer near an open fire.
- To prevent damage to the pump and other parts, it must be washed and dried before storing the sprayer in winter. Clean the surface of machines and tools, filter screen, and nozzle, and dry them in the air. Do not put them directly in the sun.
- Before storage, the battery must be fully charged. During the storage period, you need to charge your battery regularly with an adapter (at least once every 2 months).
- Keep the adapter in a dry place.