LG THERMA V R32 Split Series

Advanced Air-to-Water Heat Pump for Modern Homes

Overview

The LG THERMA V R32 Split series is an advanced air-to-water heat pump system designed for efficient heating, cooling, and domestic hot water production. It comprises an outdoor unit connected to an indoor unit via refrigerant pipes. The series offers two primary indoor unit configurations: the Integrated Water Tank (IWT) and the Hydro Box, catering to diverse installation needs. Available in 4/6 kW and 5/7/9 kW capacity ranges, the R32 Split 4/6 kW model is optimized for new build houses with high insulation and low heating demands, while the 5/7/9 kW model is suitable for both new build and renovation projects.

Key Features

R32 Split 4/6 kW

R32 Split 5/7/9 kW

Product Combinations

Product Type Phase Capacity (kW) Indoor Unit Outdoor Unit
R32 Split 4/6 kW Hydro Box 1 Φ 4 HU041MR U20 HN0613M NK5
6 HU061MR U20 HN0613M NK5
IWT 1 Φ 4 HU041MR U20 HN0613T NKO
6 HU061MR U20 HN0613T NKO
R32 Split 5/7/9 kW Hydro Box 1 Φ 5 HU051MR U44 HN091MR NK5
7 HU071MR U44 HN091MR NK5
9 HU091MR U44 HN091MR NK5
IWT 1 Φ 5 HU051MR U44 HN0913T NKO
7 HU071MR U44 HN0913T NKO
9 HU091MR U44 HN0913T NKO

Product Specifications

Indoor Unit (For IWT)

Technical Specification Unit HN0613T NKO (R32 Split 4/6 kW) HN0913T NKO (R32 Split 5/7/9 kW)
Operation Range (Leaving water temp.) Heating °C 15 - 55 15 - 65
Operation Range (Leaving water temp.) Cooling °C 5 - 27 (16 - 27) 1) 5 - 27 (16 - 27) 1)
Operation Range (Leaving water temp.) Domestic Hot Water °C 15 - 80 2) 15 - 80 3)
Volume Domestic Hot Water Tank 200 200
Domestic Hot Water Tank Material - Duplex Stainless steel Duplex Stainless steel
Internal Thermal Protect Limit °C 85 85
Flow Sensor Measuring Range ℓ/min 5 - 80 5 - 80
Water Pressure Sensor Measuring Range bar (G) 0 - 20 0 - 20
Expansion Vessel (Heating Circuit) Volume 8 8
Safety Valve Heating Circuit Upper Limit bar 3 3
Safety Valve DHW Circuit Upper Limit bar 10 10
Piping Connections Refrigerant Circuit Liquid (outside diameter) mm (Inch) Ø 6.35 (1/4") 4) Ø 9.52 (3/8") 4)
Piping Connections Refrigerant Circuit Gas (outside diameter) mm (Inch) Ø 12.7 (1/2") 4) Ø 15.88 (5/8") 4)
Piping Connections Water Circuit Inlet Inch Female G1" according to ISO228-1 (parallel pipe threads) Female G1" according to ISO228-1 (parallel pipe threads)
Piping Connections Water Circuit Outlet Inch Female G1" according to ISO228-1 (parallel pipe threads) Female G1" according to ISO228-1 (parallel pipe threads)
Piping Connections DHW Tank Water Circuit Hot Outlet Inch Female G1" according to ISO228-1 (parallel pipe threads) Female G1" according to ISO228-1 (parallel pipe threads)
Piping Connections DHW Tank Water Circuit Cold Inlet Inch Female G1" according to ISO228-1 (parallel pipe threads) Female G1" according to ISO228-1 (parallel pipe threads)
Piping Connections DHW Tank Water Circuit Recirculation Inch Female G1" according to ISO228-1 (parallel pipe threads) Female G1" according to ISO228-1 (parallel pipe threads)
Sound Power Level Heating Rated dB (A) 42 42
Dimensions Unit W×H×D mm 600 × 1,750 × 660 600 × 1,750 × 660
Weight (without water) Unit kg 118 118
Exterior Color / RAL Code - Noble White / RAL 9016 Noble White / RAL 9016
Electrical Specification Wiring Connections Power and Communication Cable (Included Earth, H07RN-F) mm² x cores 0.75 x 4 C 0.75 x 4 C
Electrical Specification Wiring Connections Type - Sheath Sheath
Electrical Specification Wiring Connections No. of Heating Coil EA 2 2
Electrical Specification Electric Heater Capacity combination kW 3 3
Electrical Specification Electric Heater Heating Step - 1 1
Electrical Specification Electric Heater Power Supply V, Ø, Hz 220-240, 1, 50 220-240, 1, 50
Electrical Specification Electric Heater Power Supply Cable (Included Earth, H07RN-F) Rated Current mm² x cores A 2.5 x 3 C 13 2.5 x 3 C 13

1) When a fan coil unit is not used. 2) For HN0613T NKO, DHW 50 ~ 80 °C operating is available only when the electric heater is operating. 3) For HN0913T NKO, DHW 58 ~ 80 °C operating is available only when the electric heater is operating. 4) When connecting the refrigerant pipe, the adaptors provided with the outdoor unit must be installed on the connection of the indoor unit.

Indoor Unit (For Hydro Box)

Technical Specification Unit HN0613M NK5 (R32 Split 4/6 kW) HN091MR NK5 (R32 Split 5/7/9 kW)
Operation Range (Leaving water temp.) Heating °C DB 15 - 55 15 - 65
Operation Range (Leaving water temp.) Cooling °C DB 5 - 27 (16 - 27) 1) 5 - 27 (16 - 27) 1)
Operation Range (Leaving water temp.) Domestic Hot Water °C DB 15 - 80 2) 15 - 80 3)
Flow Sensor Measuring Range ℓ/min 5 - 80 5 - 80
Water Pressure Sensor Measuring Range bar (G) 0 - 20 0 - 20
Expansion Vessel Volume 8 8
Safety Valve Pressure Limit bar 3 3
Piping Connections Water Circuit Inlet Inch Male PT 1" according to ISO 7-1 (tapered pipe threads) Male PT 1" according to ISO 7-1 (tapered pipe threads)
Piping Connections Water Circuit Outlet Inch Male PT 1" according to ISO 7-1 (tapered pipe threads) Male PT 1" according to ISO 7-1 (tapered pipe threads)
Piping Connections Refrigerant Circuit Gas mm (Inch) Ø 15.88 (5/8") 4) Ø 9.52 (3/8") 4)
Piping Connections Refrigerant Circuit Liquid mm (Inch) Ø 9.52 (3/8") 4) Ø 15.88 (5/8") 4)
Sound Power Level Heating Rated dB (A) 44 44
Dimensions Unit W×H×D mm 490 × 850 × 315 490 × 850 × 315
Weight Unit kg 37.8 38.1
Electrical Specification Wiring Connections Power and Communication Cable (Included Earth, H07RN-F) mm² x cores 0.75 x 4 C 0.75 x 4 C
Electrical Specification Wiring Connections Type - Sheath Sheath
Electrical Specification Wiring Connections Number of Heating Coil EA 2 2
Electrical Specification Electric Heater Capacity Combination Operation kW 1.5 + 1.5 3.0 + 3.0
Electrical Specification Electric Heater Heating Steps - Automatic Automatic
Electrical Specification Electric Heater Power Supply V, Ø, Hz 220-240, 1, 50 220-240, 1, 50
Electrical Specification Electric Heater Power Supply Cable (included earth, H07RN-F) Rated Current mm² x cores A 2.5 x 3 C 13 4.0 x 3 C 25

1) When a fan coil unit is not used. 2) For HN0613T NKO, DHW 50 ~ 80 °C operating is available only when the booster heater is operating. 3) For HN0913T NKO, DHW 58 ~ 80 °C operating is available only when the booster heater is operating. 4) When connecting the refrigerant pipe, the adaptors provided with the outdoor unit must be installed on the connection of the indoor unit.

Outdoor Unit (For R32 Split 4/6 kW)

Technical Specification Unit HN0613M NK5 HN0613T NK0 HU041MR U20 HU061MR U20
Nominal Capacity Heating (7°C OAT / 35°C LWT) kW 4.00 4.00 4.00 6.00
Nominal Capacity Heating (2°C OAT / 35°C LWT) kW 3.70 3.60 3.70 4.80
Nominal Capacity Heating (-7°C OAT / 35°C LWT) kW 3.60 3.60 3.60 4.80
Nominal Capacity Cooling (35°C OAT / 18°C LWT) kW 4.00 4.00 4.00 6.00
Nominal Capacity Cooling (35°C OAT / 7°C LWT) kW 4.00 4.00 4.00 6.00
Nominal Power Input Heating (7°C OAT / 35°C LWT) kW 0.78 0.96 0.78 1.32
Nominal Power Input Heating (2°C OAT / 35°C LWT) kW 1.21 1.30 1.21 2.01
Nominal Power Input Heating (-7°C OAT / 35°C LWT) kW 1.30 1.18 1.30 1.88
Nominal Power Input Cooling (35°C OAT / 18°C LWT) kW 0.83 0.83 0.83 1.25
Nominal Power Input Cooling (35°C OAT / 7°C LWT) kW 1.18 1.18 1.18 1.88
COP Heating (7°C OAT / 55°C LWT) W/W 5.10 4.80 5.10 4.80
COP Heating (2°C OAT / 35°C LWT) W/W 2.85 3.75 2.85 2.98
COP Heating (-7°C OAT / 35°C LWT) W/W 2.90 3.65 2.90 3.20
EER Cooling (35°C OAT / 18°C LWT) W/W 4.80 4.80 4.80 4.80
EER Cooling (35°C OAT / 7°C LWT) W/W 3.40 3.40 3.40 3.20
Operation Range Heating (Outdoor Temp.) °C DB -20 ~ 35 -20 ~ 35 -20 ~ 35 -20 ~ 35
Operation Range Cooling (Outdoor Temp.) °C DB 5 ~ 48 5 ~ 48 5 ~ 48 5 ~ 48
Compressor Type - Hermetic Sealed Twin Rotary Hermetic Sealed Twin Rotary Hermetic Sealed Twin Rotary Hermetic Sealed Twin Rotary
Refrigerant - R32 R32 R32 R32
GWP (Global Warming Potential) t-CO2 eq 675 675 675 675
Precharged Amount g 1,100 1,100 1,100 1,100
Piping Connections Outer Diameter Liquid mm (inch) Ø 6.35 (1/4") Ø 6.35 (1/4") Ø 6.35 (1/4") Ø 9.52 (3/8")
Piping Connections Outer Diameter Gas mm (inch) Ø 12.7 (1/2") Ø 12.7 (1/2") Ø 12.7 (1/2") Ø 15.88 (5/8")
Piping Connections Length Standard Max. m 5 5 5 5
Piping Connections Level Difference Max. m 30 30 30 30
Piping Connections Chargeless-Pipe Length m 30 30 30 30
Piping Connections Additional Charging Volume g/m 10 10 10 10
Rated Water Flow Rate (at LWT 35°C) ℓ/min 11.5 11.5 11.5 17.3
Sound Power Level Heating Rated dB (A) 57 57 57 58
Sound Pressure Level (at 1 m) Heating Rated dB (A) 49 49 49 50
Dimensions Unit W x H x D mm 870 × 650 × 330 870 × 650 × 330 870 × 650 × 330 870 × 650 × 330
Weight Unit kg 44.7 44.7 44.7 44.7
Exterior Color / RAL Code - Warm Gray / RAL 7044 Warm Gray / RAL 7044 Warm Gray / RAL 7044 Warm Gray / RAL 7044
Electrical Specification Voltage, Phase, Frequency Outdoor Unit V, Ø, Hz 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50
Electrical Specification Power Supply Rated Running Current Heating A 3.5 3.5 3.5 5.6
Electrical Specification Power Supply Rated Running Current Cooling A 5.6 5.4 5.6 5.4
Electrical Specification Recommended Circuit Breaker A 16 16 16 20
Electrical Specification Wiring Connections Power Supply Cable (Included Earth, H07RN-F) mm² x cores 2.5 x 3 C 2.5 x 3 C 2.5 x 3 C 2.5 x 3 C

1. Due to LG's policy of innovation, some specifications may be changed without notification. 2. Wiring cable size must comply with the applicable local and national codes. Especially the power cable and circuit breaker should be selected in accordance with that. 3. Sound power level is measured on the rated condition in accordance with ISO 9614 standard. Sound pressure level is converted from sound power level based on tonality penalty of 0 dB and installation in free-field. The directivity index (Q) is assumed as 2. Therefore, these values can be increased owing to ambient conditions during operation. Rated sound power level is in accordance with EN12102-1 under condition of EN14825. 4. Performances are in accordance with EN14511 and reflect ErP testing conditions. Above gives the declared values at rated conditions acc. ErP regulation. Rated running current: Outdoor Temp. 7°C (DB) / 6°C (WB), Leaving Water Temp. 35°C. Interconnected pipe length is standard length and difference of elevation (Outdoor ~ Indoor unit) is 0 m. 5. This product contains fluorinated greenhouse gases. 6. All installation sites must be equipped with an earth leakage circuit breaker (ELCB).

Outdoor Unit (For R32 Split 5/7/9 kW)

Technical Specification Unit HN091MR NK5 HN0913T NK0 HU051MR U44 HU071MR U44 HU091MR U44
Nominal Capacity Heating (7°C OAT / 35°C LWT) kW 5.50 5.50 5.50 7.00 9.00
Nominal Capacity Heating (2°C OAT / 35°C LWT) kW 5.50 5.50 5.50 7.00 9.00
Nominal Capacity Heating (-7°C OAT / 35°C LWT) kW 3.30 4.20 3.30 4.20 5.40
Nominal Capacity Cooling (35°C OAT / 18°C LWT) kW 5.50 5.50 5.50 7.00 9.00
Nominal Capacity Cooling (35°C OAT / 7°C LWT) kW 5.50 5.50 5.50 7.00 9.00
Nominal Power Input Heating (7°C OAT / 55°C LWT) kW 1.12 1.20 1.12 1.43 1.94
Nominal Power Input Heating (2°C OAT / 35°C LWT) kW 1.57 1.56 1.57 1.57 1.57
Nominal Power Input Heating (-7°C OAT / 35°C LWT) kW 0.94 1.20 0.94 1.20 1.54
Nominal Power Input Cooling (35°C OAT / 18°C LWT) kW 1.20 1.20 1.20 1.56 2.14
Nominal Power Input Cooling (35°C OAT / 7°C LWT) kW 1.96 1.88 1.96 2.59 3.46
COP Heating (7°C OAT / 55°C LWT) W/W 4.90 4.50 4.90 4.50 4.65
COP Heating (2°C OAT / 35°C LWT) W/W 3.50 3.50 3.50 3.50 3.50
COP Heating (-7°C OAT / 35°C LWT) W/W 3.52 3.51 3.52 3.51 3.50
EER Cooling (35°C OAT / 18°C LWT) W/W 4.60 4.50 4.60 4.50 4.20
EER Cooling (35°C OAT / 7°C LWT) W/W 2.80 2.70 2.80 2.70 2.60
Operation Range Heating (Outdoor Temp.) °C DB -25 ~ 35 -25 ~ 35 -25 ~ 35 -25 ~ 35 -25 ~ 35
Operation Range Cooling (Outdoor Temp.) °C DB 5 ~ 48 5 ~ 48 5 ~ 48 5 ~ 48 5 ~ 48
Compressor Type - Hermetic Sealed Scroll Hermetic Sealed Scroll Hermetic Sealed Scroll Hermetic Sealed Scroll Hermetic Sealed Scroll
Refrigerant - R32 R32 R32 R32 R32
GWP (Global Warming Potential) t-CO2 eq 675 675 675 675 675
Precharged Amount g 1,500 1,500 1,500 1,500 1,500
Piping Connections Outer Diameter Liquid mm (inch) Ø 15.88 (5/8") Ø 15.88 (5/8") Ø 15.88 (5/8") Ø 15.88 (5/8") Ø 15.88 (5/8")
Piping Connections Outer Diameter Gas mm (inch) Ø 9.52 (3/8") Ø 9.52 (3/8") Ø 9.52 (3/8") Ø 9.52 (3/8") Ø 9.52 (3/8")
Piping Connections Length Standard Max. m 5 5 5 5 5
Piping Connections Level Difference Max. m 50 50 50 50 50
Piping Connections Chargeless-Pipe Length m 30 30 30 30 30
Piping Connections Additional Charging Volume g/m 20.1 20.1 20.1 25.9 25.9
Rated Water Flow Rate (at LWT 35°C) ℓ/min 15.8 15.8 15.8 20.1 25.9
Sound Power Level Heating Rated dB (A) 60 60 60 60 60
Sound Pressure Level (at 1 m) Heating Rated dB (A) 52 52 52 52 52
Dimensions Unit W x H x D mm 950 × 834 × 330 950 × 834 × 330 950 × 834 × 330 950 × 834 × 330 950 × 834 × 330
Weight Unit kg 60 60 60 60 60
Exterior Color / RAL Code - Warm Gray / RAL 7044 Warm Gray / RAL 7044 Warm Gray / RAL 7044 Warm Gray / RAL 7044 Warm Gray / RAL 7044
Electrical Specification Voltage, Phase, Frequency Outdoor Unit V, Ø, Hz 220 ~ 240, 1, 50 220 ~ 240, 1, 50 220 ~ 240, 1, 50 220 ~ 240, 1, 50 220 ~ 240, 1, 50
Electrical Specification Power Supply Rated Running Current Heating A 6.3 5.9 6.3 6.9 8.6
Electrical Specification Power Supply Rated Running Current Cooling A 6.9 5.5 6.9 7.5 9.5
Electrical Specification Recommended Circuit Breaker A 25 25 25 25 30
Electrical Specification Wiring Connections Power Supply Cable (Included Earth, H07RN-F) mm² x cores 4.0 x 3 C 2.5 x 3 C 4.0 x 3 C 4.0 x 3 C 4.0 x 3 C

1. Due to LG's policy of innovation, some specifications may be changed without notification. 2. Wiring cable size must comply with the applicable local and national codes. Especially the power cable and circuit breaker should be selected in accordance with that. 3. Sound power level is measured on the rated condition in accordance with ISO 9614 standard. Sound pressure level is converted from sound power level based on tonality penalty of 0 dB and installation in free-field. The directivity index (Q) is assumed as 2. Therefore, these values can be increased owing to ambient conditions during operation. Rated sound power level is in accordance with EN12102-1 under condition of EN14825. 4. Performances are in accordance with EN14511 and reflect ErP testing conditions. Above gives the declared values at rated conditions acc. ErP regulation. Rated running current: Outdoor Temp. 7°C (DB) / 6°C (WB), Leaving Water Temp. 35°C. Interconnected pipe length is standard length and difference of elevation (Outdoor ~ Indoor unit) is 0 m. 5. This product contains fluorinated greenhouse gases. 6. All installation sites must be equipped with an earth leakage circuit breaker (ELCB).

Seasonal Energy Efficiency

R32 Split 4/6 kW

Description Unit HN0613M NK5 HN0613T NK0 HU041MR U20 HU061MR U20
Space Heating (According to EN14825) Average Climate Water Outlet 35°C SCOP - 4.65 4.65 4.65 4.65
Space Heating (According to EN14825) Average Climate Water Outlet 35°C Seasonal Space Heating Efficiency (ηs) % 183 183 183 183
Space Heating (According to EN14825) Average Climate Water Outlet 35°C Seasonal Space Heating Eff. Class - A+++ A+++ A+++ A+++
Space Heating (According to EN14825) Average Climate Water Outlet 55°C SCOP - 3.23 3.23 3.23 3.23
Space Heating (According to EN14825) Average Climate Water Outlet 55°C Seasonal Space Heating Efficiency (ηs) % 126 126 126 126
Space Heating (According to EN14825) Average Climate Water Outlet 55°C Seasonal Space Heating Eff. Class - A++ A++ A++ A++
Domestic Hot Water Efficiency 1) (According to EN 16147) Declared Load Profile - L L L L
Domestic Hot Water Efficiency 1) (According to EN 16147) Water Heating Efficiency (ηwh) % 133 133 133 133
Domestic Hot Water Efficiency 1) (According to EN 16147) COPDHW - 3.15 3.15 3.15 3.15
Domestic Hot Water Efficiency 1) (According to EN 16147) Water Heating Eff. Class - A+ A+ A+ A+
Domestic Hot Water Efficiency 1) (According to EN 16147) Declared Load Profile - L L L L
Domestic Hot Water Efficiency 1) (According to EN 16147) Water Heating Efficiency (ηwh) % 160 160 160 160
Domestic Hot Water Efficiency 1) (According to EN 16147) COPDHW - 3.69 3.69 3.69 3.69
Domestic Hot Water Efficiency 1) (According to EN 16147) Water Heating Eff. Class - A++ A++ A++ A++
Domestic Hot Water Efficiency 1) (According to EN 16147) Declared Load Profile - L L L L
Domestic Hot Water Efficiency 1) (According to EN 16147) Water Heating Efficiency (ηwh) % 110 110 110 110
Domestic Hot Water Efficiency 1) (According to EN 16147) COPDHW - 2.54 2.54 2.54 2.54
Domestic Hot Water Efficiency 1) (According to EN 16147) Water Heating Eff. Class - A A A A

1) The domestic hot water efficiency is only for IWT type indoor units. * Keymark, Eurovent, MCS and EHPA label under development.

R32 Split 5/7/9 kW

Description Unit HU051MR U44 HU071MR U44 HU091MR U44
Space Heating (According to EN14825) Average Climate Water Outlet 35°C SCOP - 4.65 4.65 4.65
Space Heating (According to EN14825) Average Climate Water Outlet 35°C Seasonal Space Heating Efficiency (ηs) % 183 183 183
Space Heating (According to EN14825) Average Climate Water Outlet 35°C Seasonal Space Heating Eff. Class - A+++ A+++ A+++
Space Heating (According to EN14825) Average Climate Water Outlet 55°C SCOP - 3.23 3.23 3.23
Space Heating (According to EN14825) Average Climate Water Outlet 55°C Seasonal Space Heating Efficiency (ηs) % 126 126 126
Space Heating (According to EN14825) Average Climate Water Outlet 55°C Seasonal Space Heating Eff. Class - A++ A++ A++
Domestic Hot Water Efficiency 1) (According to EN 16147) Declared Load Profile - L L XL
Domestic Hot Water Efficiency 1) (According to EN 16147) Water Heating Efficiency (ηwh) % 133 133 140
Domestic Hot Water Efficiency 1) (According to EN 16147) COPDHW - 3.15 3.15 3.40
Domestic Hot Water Efficiency 1) (According to EN 16147) Water Heating Eff. Class - A+ A+ A+
Domestic Hot Water Efficiency 1) (According to EN 16147) Declared Load Profile - L L XL
Domestic Hot Water Efficiency 1) (According to EN 16147) Water Heating Efficiency (ηwh) % 160 160 170
Domestic Hot Water Efficiency 1) (According to EN 16147) COPDHW - 3.69 3.69 4.10
Domestic Hot Water Efficiency 1) (According to EN 16147) Water Heating Eff. Class - A++ A++ A++
Domestic Hot Water Efficiency 1) (According to EN 16147) Declared Load Profile - L L XL
Domestic Hot Water Efficiency 1) (According to EN 16147) Water Heating Efficiency (ηwh) % 110 110 115
Domestic Hot Water Efficiency 1) (According to EN 16147) COPDHW - 2.54 2.54 2.65
Domestic Hot Water Efficiency 1) (According to EN 16147) Water Heating Eff. Class - A A A

1) The domestic hot water efficiency is only for IWT type indoor units. * 9 kW 1 Φ model. * A+++ to D scale.

Key Advantages

Easy Installation

Excellent Performance & Efficiency

User Convenience

Technology Highlights

R1 Compressor™ Revolutionary Technology

The R1 Compressor™ technology provides enhanced efficiency, reliability, and operational range. Key internal features include centrifugal oil return and an oil separating guide for reduced oil discharge, a shaft-through structure for solid compressor operation and higher durability, and bottom compression for lower noise, vibration, less weight, and superior reliability.

ThinQ Seamless Connectivity

LG ThinQ, a smartphone app, allows users to monitor and manage compatible LG products remotely. Users can set the temperature and regulate the use of their THERMA V anytime and anywhere. LG ThinQ technology also integrates with Google Assistant, enabling voice control for THERMA V units in most EU countries.

Energy States Interlock

LG Therma V offers an energy state interlock function that enables customers to maximize the use of their own renewable energy. It can shift indoor unit set points based on input signals from an Energy Storage System (ESS) or other third-party devices via Modbus or Digital 230 V inputs. This allows for energy generated from solar panels to be sent to a battery, used to heat the water tank once the battery is full, and surplus energy can be sold to the grid. The LG ThinQ app provides status monitoring.

Indoor Unit Components and Connections

IWT Indoor Unit

Components

Connections

* According to ISO 228-1 (parallel pipe threads)
** In case of Split 4/6 kW model, the adaptors provided with the outdoor unit must be separately installed on the gas/liquid connection of the indoor unit when connecting the refrigerant pipe. After installing the adaptors, the liquid and gas connection size becomes Ø 6.35 (1/4 inch) and Ø 12.7 (1/2 inch) respectively.

Hydro Box Indoor Unit

Components

Connections

* According to ISO 7-1 (tapered pipe threads)
** In case of Split 4/6 kW model, the adaptors provided with the outdoor unit must be separately installed on the gas/liquid connection of the indoor unit when connecting the refrigerant pipe. After installing the adaptors, the liquid and gas connection size becomes Ø 6.35 (1/4 inch) and Ø 12.7 (1/2 inch) respectively.

Performance Tables

R32 Split 4/6 kW Performance

Heating Operation (Maximum Heating Capacity)

Outdoor LWT (°C) Capacity (kW)
3035404550556065
HU041MR U20 + HN0613T NK0 (IWT) / HN0613M NK5 (Hydro Box)
-20 °C DB 4.004.004.004.004.004.004.004.00 4.00
-15 °C DB 4.004.004.004.004.004.004.004.00 4.00
-7 °C DB 4.004.004.004.004.004.004.004.00 4.00
-4 °C DB 4.004.004.004.004.004.004.004.00 4.00
-2 °C DB 4.004.004.004.004.004.004.004.00 4.00
2 °C DB 4.004.004.004.004.004.004.004.00 4.00
7 °C DB 4.004.004.004.004.004.004.004.00 4.00
10 °C DB 4.004.004.004.004.004.004.004.00 4.00
15 °C DB 4.004.004.004.004.004.004.004.00 4.00
18 °C DB 4.004.004.004.004.004.004.004.00 4.00
20 °C DB 4.004.004.004.004.004.004.004.00 4.00
35 °C DB 4.004.004.004.004.004.004.004.00 4.00
HU061MR U20 + HN0613T NK0 (IWT) / HN0613M NK5 (Hydro Box)
-20 °C DB 4.924.784.644.505.406.006.006.00 6.00
-15 °C DB 5.565.525.485.446.006.006.006.00 6.00
-7 °C DB 6.006.006.006.006.006.006.006.00 6.00
-4 °C DB 6.006.006.006.006.006.006.006.00 6.00
-2 °C DB 6.006.006.006.006.006.006.006.00 6.00
2 °C DB 6.006.006.006.006.006.006.006.00 6.00
7 °C DB 6.006.006.006.006.006.006.006.00 6.00
10 °C DB 6.006.006.006.006.006.006.006.00 6.00
15 °C DB 6.006.006.006.006.006.006.006.00 6.00
18 °C DB 6.006.006.006.006.006.006.006.00 6.00
20 °C DB 6.006.006.006.006.006.006.006.00 6.00
35 °C DB 6.006.006.006.006.006.006.006.00 6.00

Cooling Operation (Maximum Cooling Capacity)

Outdoor LWT (°C) Capacity (kW)
71013151820
HU041MR U20 + HN0613T NK0 (IWT) / HN0613M NK5 (Hydro Box)
10 °C DB 4.004.004.004.004.004.00 4.00
20 °C DB 4.004.004.004.004.004.00 4.00
30 °C DB 4.004.004.004.004.004.00 4.00
35 °C DB 4.004.004.004.004.004.00 4.00
40 °C DB 4.004.004.004.004.004.00 4.00
45 °C DB 4.004.004.004.004.004.00 4.00
HU061MR U20 + HN0613T NK0 (IWT) / HN0613M NK5 (Hydro Box)
10 °C DB 6.006.006.006.006.006.00 6.00
20 °C DB 6.006.006.006.006.006.00 6.00
30 °C DB 6.006.006.006.006.006.00 6.00
35 °C DB 6.006.006.006.006.006.00 6.00
40 °C DB 5.745.815.875.915.946.00 6.00
45 °C DB 5.485.615.735.815.946.00 6.00

Note: 1. DB : Dry Bulb Temperature (°C), LWT : Leaving Water Temperature (°C) 2. Direct interpolation is permissible. Do not extrapolate. 3. Measuring procedure follows EN-14511. Rated values are based on standard conditions and can be found on specifications. 4. The shaded areas are not guaranteed continuous operation.

R32 Split 5/7/9 kW Performance

Heating Operation (Maximum Heating Capacity)

Outdoor LWT (°C) Capacity (kW)
3035404550556065
HU051MR U44 + HN0913T NK0 (IWT)
-25 °C DB 4.023.903.783.664.134.585.505.50 5.50
-20 °C DB 4.644.514.384.264.725.505.505.50 5.50
-15 °C DB 5.265.124.994.855.505.505.505.50 5.50
-7 °C DB 5.505.505.505.505.505.505.505.50 5.50
-4 °C DB 5.505.505.505.505.505.505.505.50 5.50
-2 °C DB 5.505.505.505.505.505.505.505.50 5.50
2 °C DB 5.505.505.505.505.505.505.505.50 5.50
7 °C DB 5.505.505.505.505.505.505.505.50 5.50
10 °C DB 5.505.505.505.505.505.505.505.50 5.50
15 °C DB 5.505.505.505.505.505.505.505.50 5.50
18 °C DB 5.505.505.505.505.505.505.505.50 5.50
20 °C DB 5.505.505.505.505.505.505.505.50 5.50
35 °C DB 5.505.505.505.505.505.505.505.50 5.50
HU071MR U44 + HN0913T NK0 (IWT)
-25 °C DB 5.004.854.714.564.955.326.497.00 7.00
-20 °C DB 5.585.435.275.115.495.497.007.00 7.00
-15 °C DB 6.176.005.835.667.007.007.007.00 7.00
-7 °C DB 7.007.007.007.007.007.007.007.00 7.00
-4 °C DB 7.007.007.007.007.007.007.007.00 7.00
-2 °C DB 7.007.007.007.007.007.007.007.00 7.00
2 °C DB 7.007.007.007.007.007.007.007.00 7.00
7 °C DB 7.007.007.007.007.007.007.007.00 7.00
10 °C DB 7.007.007.007.007.007.007.007.00 7.00
15 °C DB 7.007.007.007.007.007.007.007.00 7.00
18 °C DB 7.007.007.007.007.007.007.007.00 7.00
20 °C DB 7.007.007.007.007.007.007.007.00 7.00
35 °C DB 7.007.007.007.007.007.007.007.00 7.00
HU091MR U44 + HN0913T NK0 (IWT)
-25 °C DB 6.406.206.005.806.316.769.009.00 9.00
-20 °C DB 7.237.006.776.547.029.009.009.00 9.00
-15 °C DB 8.067.807.547.289.009.009.009.00 9.00
-7 °C DB 9.009.009.009.009.009.009.009.00 9.00
-4 °C DB 9.009.009.009.009.009.009.009.00 9.00
-2 °C DB 9.009.009.009.009.009.009.009.00 9.00
2 °C DB 9.009.009.009.009.009.009.009.00 9.00
7 °C DB 9.009.009.009.009.009.009.009.00 9.00
10 °C DB 9.009.009.009.009.009.009.009.00 9.00
15 °C DB 9.009.009.009.009.009.009.009.00 9.00
18 °C DB 9.009.009.009.009.009.009.009.00 9.00
20 °C DB 9.009.009.009.009.009.009.009.00 9.00
35 °C DB 9.009.009.009.009.009.009.009.00 9.00

Cooling Operation (Maximum Cooling Capacity)

Outdoor LWT (°C) Capacity (kW)
7101315182022
HU051MR U44 + HN091MR NK5 (Hydro Box)
10 °C DB 6.426.957.497.858.398.759.11 9.00
20 °C DB 6.056.376.706.917.237.457.66 9.00
30 °C DB 5.685.795.905.976.086.156.22 9.00
35 °C DB 5.505.505.505.505.505.505.50 9.00
40 °C DB 5.325.345.355.375.385.405.41 9.00
45 °C DB 5.135.175.215.235.275.295.32 9.00
HU071MR U44 + HN091MR NK5 (Hydro Box)
10 °C DB 8.178.859.549.9910.6811.1311.59 9.00
20 °C DB 7.708.118.528.809.219.489.75 9.00
30 °C DB 7.237.377.517.607.747.837.92 9.00
35 °C DB 7.007.007.007.007.007.007.00 9.00
40 °C DB 6.776.796.816.836.856.876.88 9.00
45 °C DB 6.536.586.636.666.706.746.77 9.00
HU091MR U44 + HN091MR NK5 (Hydro Box)
10 °C DB 10.5011.3812.2612.8513.7314.3114.90 9.00
20 °C DB 9.9010.4310.9611.3111.8412.1912.54 9.00
30 °C DB 9.309.489.659.779.9510.0610.18 9.00
35 °C DB 9.009.009.009.009.009.009.00 9.00
40 °C DB 8.708.738.768.788.818.838.85 9.00
45 °C DB 8.408.468.528.568.628.668.70 9.00

Note: 1. DB : Dry Bulb Temperature (°C), LWT : Leaving Water Temperature (°C) 2. Direct interpolation is permissible. Do not extrapolate. 3. Measuring procedure follows EN-14511. Rated values are based on standard conditions and can be found on specifications. 4. The shaded areas are not guaranteed continuous operation. 5. Above table values may not be matched according to installation conditions. Except for rated values, the performance is not guaranteed. 6. The rating might slightly vary depending on test standards or countries.

PDF preview unavailable. Download the PDF instead.

THERMA V (AWHP) R32 Split Series leaflet (including 4,6 kW Split) 0106 FIN low Adobe InDesign 15.0 (Macintosh) iLovePDF

Related Documents

Preview LG THERMA V Monobloc S: Silence Supreme Heat Pump - Features & Specs
Explore the LG THERMA V Monobloc S, a high-efficiency, low-noise air-to-water heat pump. Discover its key features, technical specifications, product range, and smart home integration for optimal home comfort.
Preview LG Air-to-Water Heat Pump Installation Manual
Comprehensive installation manual for LG Air-to-Water Heat Pumps (Therma V series), covering general information, installation procedures, safety instructions, and accessory integration.
Preview LG THERMA V: A Comprehensive Benefit Guide for Installers
Discover the advantages of LG THERMA V heat pump systems, including easy installation, advanced compressor technology, reliability in cold climates, smart tools, comprehensive training, partner programs, and lead generation for HVAC professionals.
Preview LG THERMA V R32 Monobloc: Easy Installation, Maintenance, and Specifications
A comprehensive guide to LG's THERMA V R32 Monobloc heat pump systems, detailing easy installation and maintenance features, advanced product specifications, performance data across various models, and available accessories. This document highlights the system's energy efficiency, low-temperature heating performance, and integration capabilities, making it suitable for residential and commercial applications.
Preview LG Air-to-Water Heat Pump Owner's Manual
Comprehensive owner's manual for LG Air-to-Water Heat Pump systems, detailing operation, safety, settings, and maintenance for optimal performance and user guidance.
Preview LG Air Conditioners and Heat Pumps Price List 2024
LG's 2024 price list for air conditioners and heat pumps, featuring various product lines including DualCool, Artcool, Therma V, and Multi V systems, distributed by inTECHNA s.r.o.
Preview LG THERMA V High Temperature Heat Pump: Efficient 80°C Hot Water Solutions
Explore the LG THERMA V High Temperature heat pump, delivering up to 80°C hot water with superior energy efficiency. Featuring cascade 2-stage compression, it's ideal for modern heating needs, including older radiator systems, offering comfort and cost savings.
Preview LG KNUAB121A R32 Multi F Wall Mounted Indoor Unit: Technical Specifications & Dimensions
Detailed technical specifications and dimensions for the LG KNUAB121A R32 Multi F Wall Mounted High Efficiency Indoor Unit. Features 12,000 Btu/h cooling, 13,600 Btu/h heating, R32 refrigerant, and advanced controls.