Mosquito Net Air Conditioner
Product Overview
Illustration of a portable air conditioner unit with a front grille, control panel, and base.
User Manual
Model: K5
Introduction and Warnings
Thank you for choosing this brand of air conditioner. To ensure correct usage, please read this manual carefully before use and save it for future reference. If the manual is lost, please contact the local dealer.
Preface
This is a high-quality portable mobile air conditioner. This manual is a general version for this model. Your specific unit may differ slightly from these descriptions, but basic operations and usage will remain unaffected. Please read the manual sections carefully against your purchased machine and keep it properly for future use.
Warning Matters
Use the appliance as described in the instructions for use guide.
- Like other electrical appliances, this instruction manual includes warnings about potential events and usual practices for operation and installation.
- Children or individuals without self-care ability are prohibited from using this product unsupervised.
- This electrical appliance is designed for household indoor use only and cannot be used for other purposes.
- If the power cord is damaged, it must be replaced by the manufacturer, a service agent, or an equivalent organization to avoid danger.
- Any change or replacement of the appliance's characteristics is very dangerous.
- If the appliance requires repair, please contact the manufacturer's authorized technical service center. Adhere to using original vulnerable parts; repair by unauthorized individuals is dangerous and invalidates the warranty.
Safety and Installation Guidelines
- The electrical appliance must be installed with grounding, and the internal circuit must be tested by qualified technical personnel.
- Do not use the electrical appliance outdoors.
- Do not obstruct the air outlet and air inlet.
- Do not use any extension cables.
- Pull out the power plug before cleaning or maintaining the appliance. Do not pull the cable to move the appliance.
- Do not install the electrical appliance in a room with natural gas, gasoline, or sulfur, and it cannot be installed close to heat sources.
- Do not use the electrical appliance on a slope.
- Maintain a distance of at least 45cm from flammable materials (such as alcohol) or durable containers (e.g., aerosol tanks).
- Do not place heavy objects or hot objects on top of the machine.
- Clean the filter screen regularly.
- When transporting the electrical appliance, keep it vertical and place it on its side. Before moving, empty the water tank. After transportation, wait for half an hour before starting.
- R134a / R410A / R290 are refrigerants compliant with environmental standards. The refrigerant cycle is closed. At the end of its service life, submit the appliance to a special recycling center.
- Packages are recyclable; place them in corresponding waste sorting recycling bins.
- Installation must comply with relevant national laws and regulations.
Power Connection and Product Introduction
Power Connection
If you move the appliance, please restart it after half an hour. Before inserting the power plug into the outlet, check:
- The main power supply system meets the requirements marked on the appliance's nameplate.
- Power sockets and circuits are suitable for this appliance.
- To match the power socket and plug, replace the plug with a qualified electrician's assistance.
- The power socket must have a grounding setting.
- Electrical cables must be replaced by approved service personnel.
- The manufacturer is not liable for non-compliance with safety rules.
- If the appliance has Wi-Fi, its transmission power is less than 20 dBm, with an RF range of 2412 MHz-2472 MHz.
1.1 Product Overview
- The power supply for this product is 110VAC.
- Working modes include: refrigeration, sleep, dehumidification, and air supply.
- This product consists of a main board, remote control, display panel, sensor, compressor, internal and external motors, etc.
- It features anti-freezing protection, a 3-minute compressor delay protection, fault protection, and power loss memory.
- The product is manufactured by default.
Product Specifications
Specification | Details |
---|---|
Model No. | K5 |
Rated voltage frequency | 110V / 220V |
Cooling capacity | 550W / 1900BTU |
Rated current | 1.5A |
Rated power | 280W |
Max. input current | 2A |
Max. input power | 440W |
Max. working pressure (suction side/exhaust side) | 0.6/2.6MPa |
Max. allowable pressure (suction side/exhaust side) | 0.6/2.6MPa |
Maximum working pressure of heat exchanger | 2.6MPa |
Circulating air volume | 80m³/h |
Refrigerant | R134a / R290 |
Protection against electric shock | Class I |
Noise | ≤ 50dB(A) |
Product size | 42×23×28cm |
Product net weight | 9.5kg |
Key Controls and Instructions
2.1 [On / Off] Button
Press the
button to start up, and press it again to enter standby mode.2.2 [+] and [-] Buttons
In refrigeration mode, press the
and buttons to adjust the set temperature.2.3 [Dehumidifier] Button
Press the
button to turn the dehumidification function on or off.2.4 [Timing] Button
Press the
button to set the timing shutdown. Use the and buttons to adjust the shutdown time. Press the button to set the timing start, and use the and buttons to adjust the start time.Protection Instructions
3.1 Compressor Protection
The minimum time to restart the compressor after it stops is 3 minutes. You do not need to wait 3 minutes for the first power-on. Before powering off, no waiting period is required. After powering on again, a 3-minute wait is necessary. The compressor will run for at least 3 minutes after activation, even if shutdown conditions are met, unless it is a shutdown command.
3.2 Fault Protection
Order Number | Fault Name | Fault Code Display | Fault Description | Fault Treatment | Explanation |
---|---|---|---|---|---|
1 | Indoor ambient temperature failure | E1 | Sensor is open or short circuit | Halt | The query is displayed |
Note 1: Press the wind speed key and the [-] key for 2 seconds to query the display fault. Press the wind speed key and the [-] key again for 2 seconds to exit the fault query and return to normal display. After power failure, press the wind speed key and the [-] key for 2 seconds to display the fault; multiple faults are displayed in order.
3.3 Power-Off Memory
- When the unit is in standby before power failure, or if the timing shutdown function is set, it will enter standby mode again upon power restoration.
- Before power off, the unit saves the original mode, set temperature, wind speed, temperature unit, water motor enabling switch status, etc.
Accessories
Serial Number | Component Diagram Description | Part Name | Quantity |
---|---|---|---|
1 | Illustration of the main air conditioner unit. | Air Conditioner Host | 1 |
2 | Illustration of a remote control with buttons. | Remote Control | 1 |
3 | Illustration of a booklet labeled 'User Manual'. | User Manual | 1 |
4 | Illustration of a flexible, corrugated exhaust hose. | Exhaust Duct | 1 |
5 | Illustration of an adapter piece, likely for the exhaust duct. | Adapter | 1 |
6 | Illustration of a clear, flexible drain hose (Inner Diameter: 7MM). | Drain Pipe (Inner Diameter: 7MM) | 1 |
7 | Illustration of a small screw (M3 * 8). | Screw (M3 * 8) | 2 |
User Instructions
- After purchase, place the machine for two hours according to the direction of the arrow on the carton. After each shutdown, wait at least 5 minutes before starting the machine again.
- Before using, distinguish the cold air end and the hot air end by the logo on the machine. The air outlet is on the top at both ends, and the bottom is the air inlet. The air outlet must not be blocked. The hot air outlet requires an unobstructed space of at least 60 cm. Maintain at least a 10 cm gap on both sides of the machine.
Applicable Ambient Temperature
Unit | Minimum Cooling Ambient Temperature |
---|---|
Degree Celsius (°C) | 32 (Refrigeration) |
Degree Celsius (°C) | 5 (Heating) |
- The power supply meets the standard.
- The socket is alternating current.
- Never share the same socket simultaneously with other electrical appliances.
- Power supply and voltage requirements are AC110V, 50Hz.
Hazardous Substances Information
This form is prepared according to the provisions of SJ / T 11364.
Part Name | Hazardous Material | |||||
---|---|---|---|---|---|---|
Lead (Pb) | Mercury (Hg) | Cadmium (Cd) | Hexavalent chromium (Cr (VI)) | PBB (PBB) | Polybromodi phenyl ether (PBDE) | |
Compressor and accessories | X | O | X | O | O | O |
Heat exchanger | O | O | O | O | O | O |
Pipe parts and valves | X | O | O | O | O | O |
Cryogen | O | O | O | O | O | O |
Any power-generating or power-driven machine | X | O | O | O | O | O |
Control box and electrical components | X | X | O | O | O | O |
Power supply cord and connecting line | O | O | O | O | O | O |
Fasteners such as screws and washers | O | O | O | O | O | O |
Rubber parts | O | O | O | O | O | O |
Other metal parts | O | O | O | O | O | O |
Other plastic parts | O | O | O | O | O | O |
Printed parts | O | O | O | O | O | O |
O: Indicates that the content of this hazardous substance in all homogeneous materials of the component is below the limit requirements specified in GB / T 26572.
X: Indicates that the content of the harmful substance in at least one homogeneous material of the component exceeds the limit requirements specified in GB / T 26572. However, it is extremely difficult to make the product parts completely free of these harmful substances with current technology; the design will be gradually improved with technological progress.
Maintenance Services
Statement
- Before cleaning, ensure the machine is not electrified.
- Do not use gasoline or other chemical solvents to clean the machine.
- Do not clean directly with water.
- If the machine is damaged, please contact the local retailer or repair center.
1) Filter Screen Maintenance
Clean the filter screen once a month. Method: Use a small cross screwdriver to loosen the filter fixing screw, pull out the filter, and soak it in 40°C warm water mixed with neutral lotion. Wash off debris with a brush and place it in a cool place to dry. Then, reinstall it in its original position and secure with screws.
2) Surface Cleaning
Wipe with a neutral lotion or alcohol and a damp cloth, then dry with a dry cloth.
Save Method (End of Season)
- Shut down and unplug the power supply.
- Wipe the surface of the machine with a damp cloth and then dry it.
- Roll the power cord neatly.
- Slant the machine slightly towards the leakage hole and let it stand for half an hour until all residual condensed water flows out.
- Cover the machine with plastic bags and store it in a dry place.
Note: The actual product may differ from illustrations. When a repair is needed, please contact the seller or a professional repair site.
Troubleshooting
Hitch | Check Up | Measure |
---|---|---|
The machine cannot be turned on | 1. Power-on? 2. Is the plug loose? 3. Is it turned off? 4. Is it not turned on? 5. Does the internal cable come off? |
1. Plug in. 2. Plug into the socket. 3. Reboot. 4. Tap the power switch button twice. 5. Open the large iron cover and plug in the connecting cable. |
Poor cooling effect | 1. Is the filter screen covered in dust? 2. Is the air inlet or air outlet blocked? 3. Is the space too big or are doors and windows not properly closed? 4. Other heating equipment in the room? 5. Is the exhaust pipe not well connected or blocked? |
1. Clean the filter. 2. Clean up blocked objects. 3. Use mosquito net, close doors and windows. 4. Remove heating equipment. 5. Reattach or clean the exhaust duct. |
Leakage | 1. Is the host placed horizontally? 2. Are drains blocked? 3. Too much accumulated condensate water. |
1. Place the host machine horizontally. 2. Clean the drains. 3. Remove condensate from the bucket. |
Excessive noise and vibration | 1. Is the machine placed horizontally? 2. Filter mesh blockage? 3. Internal refrigerant flow? 4. Are other objects placed on or touching the host machine? 5. Is there a "Lingling" sound inside? |
1. Place the machine horizontally. 2. Clean the filter. 3. This is a normal phenomenon. 4. Clean up useless things. 5. Find the after-sales department for repair. |
Strange odor | Whether the machine has been unused for a long time, absorbing furniture smells, which float out when the machine runs. | Run the machine for 2 to 5 minutes, and the odor will disappear. |