Mini Inverter Heat Pump Technical Data Manual
Thank you very much for purchasing our product. Before using your unit, please read this manual carefully and keep it for future reference.
Product Fiches
The following tables detail the technical specifications for various Mini Inverter Heat Pump models across different applications and temperature conditions.
Product fiche 1: Mini Inverter heat pump space heating
This fiche provides data for medium and low-temperature applications, detailing seasonal space heating efficiency, rated heat output, and annual energy consumption for various models.
Model | Energy efficiency class | Unit sound power (dB) | Rated heat output (kW) | Seasonal space heating energy efficiency (%) | Annual space heating energy consumption (kWh) |
---|---|---|---|---|---|
MGC-V5WD2N8-B | A++ | 60 | 6.4 | 140.7 | 3655 |
MGC-V7WD2N8-B | A++ | 63 | 7.3 | 143.6 | 4088 |
MGC-V9WD2N8-B | A++ | 65 | 8.2 | 145.5 | 4539 |
MGC-V12WD2N8-B | A++ | 70 | 12.5 | 141.6 | 7148 |
MGC-V12WD2RN8-B | A++ | 70 | 12.5 | 141.6 | 7146 |
MGC-V14WD2N8-B | A++ | 72 | 14.2 | 141.8 | 8079 |
MGC-V14WD2RN8-B | A++ | 72 | 14.2 | 141.8 | 8106 |
MGC-V16WD2N8-B | A++ | 72 | 14.7 | 140.6 | 8471 |
MGC-V16WD2RN8-B | A++ | 72 | 14.7 | 140.6 | 8457 |
Product fiche 2: Mini Inverter heat pump space heating
This fiche details performance under various part-load conditions for average climate low and medium temperature applications.
Product fiche 3: Mini Inverter heat pump space heating
This fiche provides data for colder climate applications, including seasonal space heating efficiency and annual energy consumption.
Product fiche 4: Mini Inverter heat pump space heating
This fiche presents data for warmer climate applications, detailing rated heat capacity, seasonal space heating efficiency, and annual energy consumption.
Product fiche 5: Mini Inverter heat pump space heating
This fiche includes part-load conditions for warmer climate applications and performance at different ambient and water temperatures.
Product fiche 6: Mini Inverter heat pump space heating
This fiche outlines product descriptions, including whether the unit is an air-to-water, water-to-water, or brine-to-water heat pump, and details features like supplementary heaters and capacity control.
Product fiche 7: Mini Inverter heat pump space cooling
This fiche provides data for space cooling applications, detailing rated cooling capacity, seasonal space cooling efficiency, and annual energy consumption under various conditions.
Product fiche 8: Mini Inverter heat pump space cooling
This fiche details part-load conditions for space cooling in medium temperature applications and includes information on air and brine/water flow rates.
ErP Information
The following tables provide ErP (Energy-related Products) information for axial fans, including overall efficiency, measurement categories, and motor specifications.
Fan Types | Directive (or Standard) for Regulation | Model Name | Information Item | Comment |
---|---|---|---|---|
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-170-8-3L+ ZL-580*190*12-3 Rev. | Ntarget = | 28.6% |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-170-8-3L+ ZL-580*190*12-3 Rev. | Overall efficiency (ne) = | 34.0% |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-170-8-3L+ ZL-580*190*12-3 Rev. | Pass or not (Criteria: ne ≥ntarget) | Pass |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-170-8-3L+ ZL-580*190*12-3 Rev. | Measurement category (A-D) | A |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-170-8-3L+ ZL-580*190*12-3 Rev. | Efficiency category (static or total) | Static |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-170-8-3L+ ZL-580*190*12-3 Rev. | Efficiency grade at optimum energy efficiency point | N =45.4 |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-170-8-3L+ ZL-580*190*12-3 Rev. | VSD is integrated within the fan | YES |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-170-8-3L+ ZL-580*190*12-3 Rev. | Year of Manufacture | Ref. to the Unit Nameplate |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-170-8-3L+ ZL-580*190*12-3 Rev. | Manufacturer's name and place of manufacture | Ref. to the Unit Nameplate |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-170-8-3L+ ZL-580*190*12-3 Rev. | Rated motor power input(s) (kW), at optimum energy efficiency | 0.156kw |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-170-8-3L+ ZL-580*190*12-3 Rev. | Rated motor flow rate(s) at optimum energy efficiency | 1.290m³/s |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-170-8-3L+ ZL-580*190*12-3 Rev. | Rated motor pressure(s) at optimum energy efficiency | 36Pa |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-170-8-3L+ ZL-580*190*12-3 Rev. | Rotations per minute (R.P.M)at the optimum energy efficiency point | 750r/min |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-170-8-3L+ ZL-580*190*12-3 Rev. | Specific ratio | 1.001 |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-170-8-3L+ ZL-580*190*12-3 Rev. | Information relevant for facilitating disassembly, recycling or disposal at end-of-life | all materials can be recycled |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-170-8-3L+ ZL-580*190*12-3 Rev. | Information relevant to minimize impact on the environment and ensure optimal life expectancy as regards installation, use and maintenance of the fan | For installation, the clearance of 500 mm shall be kept from inlet |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-170-8-3L+ ZL-580*190*12-3 Rev. | Description of additional items used when determining the fan energy efficiency,such as ducts, that are not described in the measurement category and not supplied with the fan. | Measurement category A, fan is free inlet and outlet conditions |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-170-8-3L+ ZL-580*190*12-3 Rev. | Motor manufacturer | SHISHISHI TONGDA MOTOR CO.,LTD. |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L + ZL-580*190*12-3 Rev. | Ntarget = | 29.1% |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L + ZL-580*190*12-3 Rev. | Overall efficiency (ne) = | 33.6% |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L + ZL-580*190*12-3 Rev. | Pass or not (Criteria: ne ≥ntarget) | Pass |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L + ZL-580*190*12-3 Rev. | Measurement category (A-D) | A |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L + ZL-580*190*12-3 Rev. | Efficiency category (static or total) | Static |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L + ZL-580*190*12-3 Rev. | Efficiency grade at optimum energy efficiency point | N =44.6 |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L + ZL-580*190*12-3 Rev. | VSD is integrated within the fan | YES |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L + ZL-580*190*12-3 Rev. | Year of Manufacture | Ref. to the Unit Nameplate |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L + ZL-580*190*12-3 Rev. | Manufacturer's name and place of manufacture | Ref. to the Unit Nameplate |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L + ZL-580*190*12-3 Rev. | Rated motor power input(s) (kW), at optimum energy efficiency | 0.186kw |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L + ZL-580*190*12-3 Rev. | Rated motor flow rate(s) at optimum energy efficiency | 1.292m³/s |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L + ZL-580*190*12-3 Rev. | Rated motor pressure(s) at optimum energy efficiency | 43Pa |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L + ZL-580*190*12-3 Rev. | Rotations per minute (R.P.M)at the optimum energy efficiency point | 800r/min |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L + ZL-580*190*12-3 Rev. | Specific ratio | 1.001 |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L + ZL-580*190*12-3 Rev. | Information relevant for facilitating disassembly, recycling or disposal at end-of-life | all materials can be recycled |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L + ZL-580*190*12-3 Rev. | Information relevant to minimize impact on the environment and ensure optimal life expectancy as regards installation, use and maintenance of the fan | For installation, the clearance of 500 mm shall be kept from inlet |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L + ZL-580*190*12-3 Rev. | Description of additional items used when determining the fan energy efficiency,such as ducts, that are not described in the measurement category and not supplied with the fan. | Measurement category A, fan is free inlet and outlet conditions |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L + ZL-580*190*12-3 Rev. | Motor manufacturer | GUANGDONG WELLING MOTOR MANUFACTURING CO.,LTD. |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L+ ZL-580*190*12-3 Rev. | Ntarget = | 28.9% |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L+ ZL-580*190*12-3 Rev. | Overall efficiency (ne) = | 33.0% |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L+ ZL-580*190*12-3 Rev. | Pass or not (Criteria: ne ≥ntarget) | Pass |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L+ ZL-580*190*12-3 Rev. | Measurement category (A-D) | A |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L+ ZL-580*190*12-3 Rev. | Efficiency category (static or total) | Static |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L+ ZL-580*190*12-3 Rev. | Efficiency grade at optimum energy efficiency point | N =44.1 |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L+ ZL-580*190*12-3 Rev. | VSD is integrated within the fan | YES |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L+ ZL-580*190*12-3 Rev. | Year of Manufacture | Ref. to the Unit Nameplate |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L+ ZL-580*190*12-3 Rev. | Manufacturer's name and place of manufacture | Ref. to the Unit Nameplate |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L+ ZL-580*190*12-3 Rev. | Rated motor power input(s) (kW), at optimum energy efficiency | 0.178kw |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L+ ZL-580*190*12-3 Rev. | Rated motor flow rate(s) at optimum energy efficiency | 1.420m³/s |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L+ ZL-580*190*12-3 Rev. | Rated motor pressure(s) at optimum energy efficiency | 36Pa |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L+ ZL-580*190*12-3 Rev. | Rotations per minute (R.P.M)at the optimum energy efficiency point | 800r/min |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L+ ZL-580*190*12-3 Rev. | Specific ratio | 1.001 |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L+ ZL-580*190*12-3 Rev. | Information relevant for facilitating disassembly, recycling or disposal at end-of-life | all materials can be recycled |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L+ ZL-580*190*12-3 Rev. | Information relevant to minimize impact on the environment and ensure optimal life expectancy as regards installation, use and maintenance of the fan | For installation, the clearance of 500 mm shall be kept from inlet |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L+ ZL-580*190*12-3 Rev. | Description of additional items used when determining the fan energy efficiency,such as ducts, that are not described in the measurement category and not supplied with the fan. | Measurement category A, fan is free inlet and outlet conditions |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L+ ZL-580*190*12-3 Rev. | Motor manufacturer | JIANGSU SHANGQI GROUP CO., LTD. |
Axial fan | ErP Directive 2009/125/EC COMMISSION REGULATION (EU) No 327/2011 | ZKSN-200-10-2L+ ZL-580*190*12-3 Rev. | Motor manufacturer | JIANGSU SHANGQI GROUP CO., LTD. |
Design Change Record
This table documents design changes made to the product.
Version Upgrade | Changer | Change Date | Main Content of Change | Affected Page(s) (Print Page Number) |
---|---|---|---|---|
B | Zhao Haowei | 21.11.30 | Upgrade parameters | P1\P8-11 pages |
V. B-V. C | Luo Liang | 2024.03.11 | See attachment revision record | See attachment revision record |