Antminer S23 Hyd. Product Manual
Published: May. 2025
Manufacturer: BITMAIN TECHNOLOGIES INC.
Website: www.bitmain.com
1. Specification
Product Glance
Product Glance | Value |
---|---|
Model | S23 Hyd. |
Version | 580T-10 |
Crypto algorithm/coins | SHA256|BTC/BCH/BSV |
Typical hashrate, TH/s(1-1) | 580 |
Power on wall @35°C(1-2), Watt(1-1) | 5510 |
Power efficiency on wall@35°C(1-2), J/T(1-1) | 9.5 |
Detailed Characteristics
Detailed Characteristics | Value |
---|---|
Power supply | |
Phase | 3 |
Input voltage, Volt(2-1) | 380~415 |
Input frequency range, Hz | 50~60 |
Input max current, Amp | 12 |
Hardware configuration | |
Network connection mode | RJ45 Ethernet 10/100M |
Server size (length*width*height, w/o package), mm | 410*170*209 |
Server size (length*width*height, with package), mm | 570*316*430 |
Net weight, kg | 13.5 |
Gross weight, kg | 14.8 |
Environment requirements | |
Inlet coolant temperature, °C | 20~50 |
Coolant flow, L/min | 8.0~10.0 |
Coolant pressure, bar | ≤3.5 |
Working Coolant (2-2) | Antifreeze/Pure water/Deionized water |
Coolant pH value | Antifreeze: 7.0~9.0 Pure water: 6.5~7.5 Deionized water: 8.5~9.5 |
Diameter of Coolant pipe connector, mm | OD10 |
Storage temperature, °C | -20~70 |
Operation humidity(non-condensing), RH | 10~90% |
Notes
(1-1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power on wall and power efficiency on wall fluctuate by ±5%.
(1-2) Inlet coolant temperature.
(2-1) Caution: Wrong input voltage may cause server damaged.
(2-2) For detailed working coolant use and maintenance instructions, please refer to "ANTSPACE HK3 Water Cooling Container & Dry-Wet Tower Product Manual", Chapter 9, Article 3, Point 6, "Maintenance of Coolant".
2. Performance Curve
(1) Hashrate vs. Inlet Coolant Temperature
The graph shows that the Antminer S23 Hyd. maintains a consistent hashrate of approximately 580 TH/s across inlet coolant temperatures ranging from 15°C to 55°C. Both water and antifreeze coolants result in similar performance.
(2) Power Efficiency vs. Inlet Coolant Temperature
This graph displays the Antminer S23 Hyd. power efficiency (J/T) against inlet coolant temperature (°C). For water cooling, the efficiency is around 9.5 J/T. For antifreeze cooling, the efficiency is also around 9.5 J/T at lower temperatures, increasing slightly to about 10.7 J/T at 55°C.
(3-1) The hashrate value, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power efficiency on wall fluctuate by ±5%.