Safety Instructions & Precautions
IMPORTANT SAFETY INSTRUCTIONS
READ, UNDERSTAND AND FOLLOW ALL INSTRUCTIONS. ALWAYS PLUMB AND INSTALL ALL SUCTION FITTINGS ACCORDING TO ALL BUILDING CODES THAT APPLY IN YOUR AREA.
⚠️ WARNING: When using two or more suction fittings on a common suction line, suctions must be separated by a minimum of 3 ft or they must be located on two different planes.
⚠️ WARNING: DO NOT locate suction outlets on seating areas or on backrests for such seating areas.
ℹ️ NOTICE: This manual contains important information about the installation, operation and safe use of this product. Before installing, read and follow all warning notices and instructions. This information should be given to the owner and/or operator.
⚠️ WARNING: To reduce the risk of drowning from hair and body entrapment, install suction fittings with a marked flow rate in gallons per minute that exceeds the flow rate of your system by at least 25%. Always use multiple suction outlets. If the fitting/cover breaks, is damaged, or is missing, shut the system down immediately. Do not use the system until damaged parts have been replaced.
ℹ️ NOTICE: Keep hair and clothing a minimum of 12 inches from all suction fittings and drains at all times. Persons with long hair should secure hair to a minimal length or wear swimming cap. Children should never be left unattended at any time in a swimming pool, spa, or bathtub. Be sure the water temperature never exceeds the manufacturer's recommendations.
ℹ️ NOTICE: Installation and service should be done by a qualified Service Professional, certified electrician or authorized CMP representative.
❗ NOTE: In the event that one suction outlet is completely blocked, the remaining suction outlet(s) serving that system MUST have a flow rating capable of the full flow of the pump(s) for the specific suction system.
⚠️ WARNING: Increasing size of the pump may increase flow rate of suction beyond rated safety limits causing entrapment or death.
ℹ️ NOTICE: All Suction Outlet Fitting Assemblies (SOFAs) shall be installed in accordance with the manufacturer's installation instructions, or for Registered Design Professional SOFAs, in accordance with the registered design professional's engineering plans. Field modification made to a SOFA not authorized by the manufacturer's installation instructions shall void the SOFA certification.
⚠️ WARNING: Hair or body parts blocking the spa or pool suctions may become trapped and held against the suction fitting. Entrapment against the suction fittings can result in drowning or other severe injury. Never sit on or lean up against suction fittings. Never exceed the maximum allowable flow rate stated on the suction fitting. The suction fitting and fasteners should be inspected for damage or tampering before use. Missing, broken, or cracked suction fittings shall be replaced. Loose suction fittings shall be reattached or replaced before use of this facility.
ℹ️ NOTICE: The maximum hose length difference between any self-contained SOFA and the tee leading to the pump shall not exceed 13 feet (3.96 m).
ℹ️ NOTICE: CMP drain covers are only certified for use with CMP sumps and frames. Do not mismatch with parts from other manufacturers.
SAVE THESE INSTRUCTIONS
Sizing & Specification Reference
- Suction fitting configuration specific flow ratings MUST NOT be exceeded at any time the pool is open to bathers.
- A system must install a suction fitting, or combination of multiple suctions, such that the resulting individual suction system flow rating is greater than the pumping system's maximum system flow rate.
- To reduce the risk of drowning from hair and body entrapment, install suction fittings with a marked flow rate in gallons per minute that exceeds the flow rate of your system by at least 25%. Increasing size of the pump may increase flow rate of suction beyond rated safety limits causing entrapment or death.
- Any modification that increases the flow rate of the circulation system shall require reevaluation of the cover/grate and sump to ensure that the flow rating of the Suction Outlet Fitting Assembly is not exceeded.
- The flow rating for pools with multiple, blockable SOFAs piped together in one body of water without isolation valves shall be determined by combining the flow rating of all SOFAs, minus the flow rating of one. If the flow ratings of all SOFAs are not equal, subtract the flow rating of the SOFA with the highest flow rating.
- ℹ️ NOTICE: No modification shall be made to a SOFA structure or flow path unless the new configuration has been certified as new SOFA.
TABLE 1: IAPMO LISTED MAX FLOW RATES
PLUMBING SIZE | PORTS | FLOOR FLOW RATE | WALL FLOW RATE |
---|---|---|---|
3" | BOTTOM | 184 GPM | 128 GPM |
3" | SIDE | 188 GPM | 124 GPM |
2.5" | BOTTOM OR SIDE | 156 GPM | 124 GPM |
2" | BOTTOM | 150 GPM | 120 GPM |
2" | SIDE | 124 GPM | |
1.5" | BOTTOM OR SIDE | 144 GPM | 124 GPM |
FLOW RATE VERIFIED TO CPSC TEST PROTOCOL
TABLE 2: SPECIFICATIONS
PIPE SIZE | 25513-5x - 2" FIP (ADAPTABLE TO 1.5") 25513-6x, 25516 - 2" SOCKET 25517, 25518 - 1.5" SOCKET × 2" SPIGOT 25513-2XX, 25516-2XX - 2.5" SOCKET 25513-4XX, 25513-3XX, 25516-4XX - 3" SOCKET DO NOT adapt suction fitting to any pipe size smaller than listed above. |
OPEN AREA | 14.57in² |
DRAIN COVER LIFE | 7 Years. Replace drain cover and screws every seven years. |
SUMP BODY LIFE | 30 Years |
NOTES | Multiple drain use ONLY. PVC Sump Body. Use PVC glue to attach plumbing fittings. Floor or wall installation. |
Head Loss Charts
Graph: Head Loss Chart for 1.5in PIPE
X-axis: FLOW RATE - 1.5in PIPE (0 to 200 GPM). Y-axis: TOTAL HEAD LOSS (Feet of Head) (0 to 7 feet).
Data points shown: (0 GPM, 0.36 ft), (40 GPM, 1.13 ft), (80 GPM, 2.31 ft), (120 GPM, 4.38 ft), (160 GPM, 6.75 ft).
Graph: Head Loss Chart for 2in PIPE
X-axis: FLOW RATE - 2in PIPE (0 to 200 GPM). Y-axis: TOTAL HEAD LOSS (Feet of Head) (-0.5 to 3.5 feet).
Data points shown: (0 GPM, -0.079 ft), (40 GPM, 0.20 ft), (80 GPM, 0.72 ft), (120 GPM, 1.97 ft), (160 GPM, 3.22 ft).
Graph: Head Loss Chart for 2.5in PIPE
X-axis: FLOW RATE - 2.5in PIPE (0 to 250 GPM). Y-axis: TOTAL HEAD LOSS (Feet of Head) (-0.2 to 1.4 feet).
Data points shown: (0 GPM, 0.03 ft), (50 GPM, 0.18 ft), (100 GPM, 0.38 ft), (150 GPM, 0.88 ft), (200 GPM, 1.45 ft).
Graph: Head Loss Chart for 3in PIPE
X-axis: FLOW RATE - 3in PIPE (0 to 250 GPM). Y-axis: TOTAL HEAD LOSS (Feet of Head) (0 to 1.8 feet).
Data points shown: (0 GPM, 0.55 ft), (50 GPM, 0.72 ft), (100 GPM, 0.89 ft), (150 GPM, 1.34 ft), (200 GPM, 1.84 ft).
Installation & Maintenance Procedures
1. REQUIRED FOR INSTALLATION
Your Nova Drain includes the following:
- Drain Sump Body
- Drain Suction Cover
- Cover Screws
- 2" Plugs (2)
- Protective Plaster Installation Cover
- 2" to 1.5" FPT Bushings (if threaded model)
2. INSTALLATION LOCATION
- This suction fitting is designed for installation on the floor or wall of gunite/shotcrete hot tubs or pools.
- Do not mount directly under seats.
- Always use multiple suction outlets. DO NOT use with single drain applications. Single drain installation voids warranties and increases the risk of entrapment, which can result in drowning or other severe injury. Blockable SOFAs shall be installed in a multiple SOFA system only.
- When using two or more suction fittings on a common suction line, suctions must be separated by a minimum of 3 ft or they must be located on two different planes.
SAFETY CHECKLIST:
- Suction fitting and fasteners should be observed for damage or tampering before each use.
- DO NOT adapt suction fitting to any pipe size smaller than sizes listed for model in Table 2.
- Missing, broken, or cracked suction fittings shall be replaced before use. Loose suction fittings shall be reattached or replaced before use.
3. INSTALLATION PROCEDURE
PLUMBING:
- Install sump in floor or wall. If the sump is installed in the pool/spa floor, install in the center of the pool/spa OR the deepest point.
- Cover/grates, when installed, shall not protrude more than 2 in. (51 mm) from the finished surface of the pool in which the SOFA is installed.
- See Specifications chart for plumbing size of your model.
- Plumb with either the bottom port OR side port. Plug the unused port with the included plug. On sumps with two bottom ports, the second port can be plugged or used for a hydrostatic valve.
- Maximum flow rates will vary depending on plumbing option chosen. See Table 1 for details.
GUNITE INSTALLATION:
- IMPORTANT! Leave the protective cover in place until plaster installation is complete. Use included cover screws to attach protective cover during installation.
- Finish pool with gunite/shotcrete and plaster so that it is completely level with the sump body and cover. Ensure the finish is completely level. Pool finish should not exceed the top of the sump.
- Remove the protective cover.
- When any SOFA component is held in place by the interior finish of the pool, that surface shall be free of deterioration and voids.
- Attach cover/grate with the supplied screws. Verify that the suction cover is properly tightened with the #8 316 stainless steel screws in brass inserts to 16in-lbs. DO NOT over-torque the cover screw. Excessive torque can cause premature failure of threads or damage to suction fitting increasing risk of entrapment. Start install of screws by hand to ensure proper thread engagement and to prevent cross threading. DO NOT USE POWER TOOLS TO INSTALL FASTENERS.
Diagram: IMAGE 1 - INSTALLATION (BOTTOM PORT SHOWN)
Illustrates two suction fittings installed in a pool wall or floor. Shows "Gunite/ Shotcrete" and "Plaster/Pool Finish". A "Threaded Plug" is visible in one of the ports. Text indicates "MIN 3 FT OR DIFFERENT PLANES" between the two fittings.
2. MAINTENANCE & INSPECTION
- Covers/grates and all other SOFA components shall be replaced before the end of their service life. Service life begins the month and year in which a SOFA component is installed with or without water. The cover/grate and screws should be replaced at least every seven (7) years. Sump and frame service life is 30 years.
- Inspect pool or spa regularly to ensure that the drain cover/grate is in place and secure.
- Missing, broken, or cracked SOFA components shall be replaced before bathers are allowed to use the pool or spa. Loose covers/grates shall be reattached before bathers are allowed to use the pool or spa.
- If the cover is found with color changed, broken, cracked, missing, brittle components with chunks or pieces broken off, it must be replaced. Do not use the pool/spa/facility until a replacement is made.
- If there are stripped screw holes or if the brass insert receptacles are missing/removed, the SOFA must be replaced. Do not use the pool/spa/facility until a repair or replacement is made.
- If a drain cover/grate does not pass inspection: Close the pool or spa immediately, Post a closure notice, Keep the facility closed until a new drain cover and screws are properly installed.
3. WINTERIZING
- Requirements for winter will vary depending on region - follow normal winter and freeze protection practices for your area.
- For areas that require partial drainage and/or clearing lines to prevent freeze damage:
- If your suction(s) have a dedicated suction line: Use a blower to clear the suction line of water and cap or close the line with a valve to prevent freeze damage.
- If your suction(s) are connected to a skimmer/equalizer line: Follow skimmer winterization procedures. Optionally blow and cap the suction line or fill line with foam rope/backer rod to protect from freeze damage.
Part Diagrams and Measurements
Diagram: IMAGE 2 - DIMENSIONS
Shows dimension drawings for the Nova drain. Includes:
- NOVA - SIDE VIEW: Overall width 8.5", height 3.75" to 6.6", depth 8".
- LARGE OUTLET NOVA - SIDE VIEW A: Overall height 10.1", width 7.5", outlet diameter 4.9", cover thickness 0.98".
- NOVA - BOTTOM VIEW: Shows bottom outlet and side outlet ports, with dimensions 8.5" width and 6.8" height.
- LARGE OUTLET NOVA - SIDE VIEW B: Overall height 8.0", outlet depth 3.3".
Parts List
Diagram: Exploded view of the Nova drain components with numbered parts corresponding to the list below.
Item # | CMP P/N | DESCRIPTION |
---|---|---|
1 | 61004-083-212 | SCREWS FOR 25513, 25516 |
1 | 61051-052-028 | SCREWS FOR 25515 |
1 | 61050-048-025 | SCREWS FOR 25517 |
2 | 25539-700-011 | COVER |
3 | 25513-250-020 | PLUG FOR 25513-26X, 25516-26X |
3 | 25513-300-020 | PLUG FOR 25513-4XX, 25516-4XX |
3 | 25520-050-010 | PLUG FOR 25513-5XX, 25516-5XX |
4 | 25513-250-010 | SUMP - 25513-26X |
4 | 25513-300-010 | SUMP - 25513-4XX |
4 | 25513-010-010 | SUMP - 25516-5XX |
4 | 25513-110-010 | SUMP - 25513-6XX |
4 | 25516-250-010 | SUMP - 25516-26X |
4 | 25516-300-010 | SUMP - 25516-4XX |
4 | 25516-000-010 | SUMP - 25516-5XX |
4 | 25518-000-010 | SUMP - 25517-5XX |
— | 25516-000-020 | EXTENSION COLLAR |
*Parts numbers not listed in product table are only available as part of a complete assembly. See c-m-p.com or pool products catalog for other color and kit options.
Record Information & Contact
Record Information on this System Below & Keep for Your Records:
Installer: _______________________________________________________________
Purchased From: _______________________________________________________
Installation Date: _____________________________ Model Number: ______________________________
Pool Size in Gallons: __________________________
CMP Customer Service & Tech Support
Toll Free: 1-800-733-9060
FAX: 770-732-7115
Email: support@c-m-p.com
Warranty Questions
Email: RMA@c-m-p.com