Lutron Caséta Load Controls
Caséta Load Controls
The Caséta family of dimmers, switches, and fan controls offers direct and remote control capabilities when paired with Pico remote controls, providing a system that delivers convenience and ease of installation. Caséta dimmers, switches, and fan controls utilize Lutron's patented Clear Connect RF Technology, enabling wireless communication with Pico remote controls, Caséta motion sensors, and the Lutron Smart Hub and Smart Hub PRO (formerly Smart Bridge and Smart Bridge PRO).
Features
- Works with Pico remote control
- Works with Caséta motion sensor
- Works with the Lutron App (via a Smart Hub or Smart Hub PRO)
- Lutron patented Clear Connect RF Technology works through walls and floors
- Includes Front Accessible Service Switch (FASS) for safe lamp replacement
- Works with Lutron Radio Powr Savr occupancy and vacancy sensors in standalone applications (sensors do not work with Smart Hub or Smart Hub PRO)
Note: Certain models or load types will require a neutral connection (see Load Type and Capacity sections).
The Lutron App is required for setup and usage with the Smart Hub and Smart Hub PRO. For version compatibility, please see the Google Play™ store for Android™ devices or the App Store online store for Apple® devices.
Specifications
Regulatory Approvals
- cULus Listed
- NOM Certified
- FCC Approved: Complies with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules
- Industry Canada Certified
- IFTEL Certified
- NEMA 410: PD (-5ANS, -6ANS, -5WS, -10NXD, -5NE), DVRF (-6L, -5NS, -5NE)
Power
Operating voltage:
- 120 V~ 50/60 Hz: PD (-3PCL, -6WCL, -10NXD, -6ANS, -5ANS, -5NE, -FSQN), DVRF (-6L, -5NS, -AS, -5NE)
- 120/277 V~ 50/60 Hz: -5WS-DV
Key Design Features
- Tested to withstand electrostatic discharge without damage or memory loss, in accordance with IEC 61000-4-2.
- Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991 Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits.
- Load controls always operate locally and do not require system control.
- Power failure memory: upon power interruption, the control returns to its previously set level when power is restored.
- PD-5WS-DV, PD-5ANS, PD-6ANS, PD-10NXD, DVRF-5NS, and DVRF (-6L, -5NE) use conventional 3-way wiring.
- PD-5WS-DV, PD-5ANS, PD-6ANS, PD-10NXD, DVRF-5NS, and DVRF (-6L, -5NE) can be used with a mechanical switch in 3-way applications.
- DVRF (-6L, -5NE) and DVRF-5NS can also be wired with an accessory switch, DVRF-AS.
- Uses Lutron Claro wallplates or designer-style wallplates from other manufacturers (sold separately).
- Lutron Claro wallplates snap on with no visible means of attachment.
Key Design Features (continued)
- Requires a 1-gang U.S. wallbox with 3½ in (89 mm) depth recommended, or 2¼ in (57 mm) depth minimum.
- PD- models use green status LED(s) to indicate load status.
- DVRF (-6L, -5NE) uses a white soft glow light bar, and the DVRF-5NS uses a white status LED to indicate load status.
- PD-FSQN provides 4 quiet fan speeds plus OFF for a single ceiling fan.
- Claro Smart accessory switches (DVRF-AS) control Diva Smart dimmers and switches from additional locations and do not directly control the load.
System Communications and Capacity
- Caséta switches, dimmers, and fan controls communicate with Pico remote controls, Caséta motion sensors, and the Lutron Smart Hub/Smart Hub PRO through Radio Frequency (RF).
- Devices must be located within 60 ft (18 m) line-of-sight or 30 ft (9 m) through walls of a Lutron Smart Hub, Smart Hub PRO, or Caséta Repeater.
- Devices must be located within 60 ft (18 m) line-of-sight or 30 ft (9 m) through walls of Pico remote controls or Caséta motion sensors (with no Smart Hub installed).
Device Limits
- Pico remote controls and Caséta motion sensors: up to 10 devices (total) may be paired to each Caséta switch/dimmer (with no Smart Hub installed).
- Smart Hub or Smart Hub PRO system: up to 75 total wireless devices (Caséta dimmers/switches, Pico remote controls, Caséta motion sensors, and shades) are supported per system. Smart Hub or Smart Hub PRO counts as one device. The Caséta repeater counts as one device.
Environment
- Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity, non-condensing. Indoor use only.
Features Comparison: Original and Diva/Claro Smart Models
Feature | Original Smart Models (2-wire Switch, Neutral Switch, Dimmer, PRO Dimmer, ELV+ Dimmer, Plug-In Dimmer, Fan Control) | Diva and Claro Smart Models (Diva Smart Dimmer, Diva Smart ELV+ Dimmer, Claro Smart Switch, Claro Smart Accessory Switch) |
---|---|---|
Figure # (from page 1) | 1, 2, 3, 4, 5 | 6, 7, 8 |
Simple two-wire installation (no neutral wire required) | ✔️ (PD-5WS-DV, PD-6WCL, PD-3PCL, PD-FSQN) | ✔️ (DVRF-6L, DVRF-5NE, DVRF-5NS) |
Capable of dimming loads | ✔️ (PD-6WCL, PD-10NXD, PD-5NE, DVRF-6L, DVRF-5NE) | ✔️ (DVRF-6L, DVRF-5NE) |
Preset (user defined favorite level) | ✔️ (PD-5WS-DV, PD-5ANS, PD-6ANS, PD-10NXD, PD-5NE, DVRF-6L, DVRF-5NE) | ✔️ (DVRF-6L, DVRF-5NE) |
Works with Hi-lume 1% 2-Wire LED Drivers (forward-phase only) | ✔️ (PD-6WCL, PD-10NXD, PD-5NE, DVRF-6L, DVRF-5NE) | ✔️ (DVRF-6L, DVRF-5NE) |
Works with Power Interfaces (PHPM and GRX-TVI) | ✔️ (PD-5WS-DV, PD-5ANS, PD-6ANS, PD-10NXD, PD-5NE) | ✔️ (DVRF-6L, DVRF-5NE) |
Works with Power Interfaces (PHPM-SW) | ✔️ (PD-5WS-DV, PD-5ANS, PD-6ANS) | ✔️ (DVRF-6L, DVRF-5NE) |
Works with ELV load type | ✔️ (PD-6WCL, PD-10NXD, PD-5NE, DVRF-6L, DVRF-5NE) | ✔️ (DVRF-6L, DVRF-5NE) |
Controls speed of a single ceiling fan | ✔️ (PD-FSQN) | N/A |
No wiring required | N/A | N/A |
1 In some low-wattage applications the PD-10NXD will require a neutral wire connection.
Load Type and Capacity - Switches and Fan Control
Model Number | Description | Voltage | Load Type | Minimum Load | Maximum Load (Not Ganged) | Maximum Load (End of Gang) | Maximum Load (Middle of Gang) |
---|---|---|---|---|---|---|---|
PD-5WS-DV | Two-wire switch | 120 V~ | Incandescent/Halogen | 25 W | 600 W | 450 W | 350 W |
277 V~ | Incandescent/Halogen | 25 W | 1350 W | 1100 W | 800 W | ||
120 V~ | MLV | 25 W | 600 VA/475 W | 450 VA/350 W | 350 VA/275 W | ||
277 V~ | MLV | 25 W | 1350 VA/1075 W | 1100 VA/875 W | 800 VA/625 W | ||
120 V~ | General Purpose Fan | 0.4 A | 3 A | 3 A | 3 A | ||
120/277 V~ | LED | Use LUT-MLC² | 5 A | 4 A | 3 A | ||
120/277 V~ | Fluorescent | Use LUT-MLC² | 5 A | 4 A | 3 A | ||
120 V~ | ELV | Use LUT-MLC² | 600 W | 450 W | 350 W | ||
277 V~ | ELV | Use LUT-MLC² | 1350 W | 1100 W | 800 W | ||
PD-5ANS, DVRF-5NS | Neutral-wire switch (neutral connection required) | 120 V~ | Incandescent/Halogen | 10 W | 600 W | 600 W | 600 W |
MLV | 10 W | 600 VA | 600 VA | 600 VA | |||
Fan | 0.1 A | 3 A | 3 A | 3 A | |||
LED | 1 bulb | 5 A | 5 A | 5 A | |||
Fluorescent | 1 ballast | 5 A | 5 A | 5 A | |||
ELV | 10 W | 600 W | 600 W | 600 W | |||
PHPM-SW | 1 interface | 2 interfaces | 2 interfaces | 2 interfaces | |||
PD-6ANS, PD-6ANS-XX-C | Neutral-wire switch (neutral connection required) | 120 V~ | Incandescent/Halogen | 10 W | 720 W | 720 W | 600 W |
MLV | 10 W | 720 VA | 720 VA | 600 VA | |||
Fan | 0.1 A | 3.6 A | 3.6 A | 3.6 A | |||
LED | 1 bulb | 6 A | 6 A | 5 A | |||
Fluorescent | 1 ballast | 6 A | 6 A | 5 A | |||
ELV | 10 W | 720 W | 720 W | 600 W | |||
PHPM-SW | 1 interface | 3 interfaces | 3 interfaces | 3 interfaces | |||
PD-FSQN | Fan speed control (neutral connection required) | 120 V~ | Single Ceiling Fan (permanent split-capacitor motor) | 0.1 A | 1.5 A | 1.5 A | 1.5 A |
1 No neutral wire required.
² To ensure proper operation with LED, fluorescent, or ELV loads, a LUT-MLC may be required. If the status LED is flashing or solid red, a LUT-MLC must be installed. Installing a LUT-MLC is recommended for best performance, regardless of wattage. In rare cases, some load types may still flicker or glow when off, requiring a different load or multiple LUT-MLCs.
³ See "Ganging and Derating" section.
4 Not for use with fans that have integrated fan speed/light control modules, DC motor fans, remote control fans, or bathroom/kitchen exhaust fans.
Load Type and Capacity - Dimmers
Model Number | Description | Voltage | Load Type | Minimum Load | Maximum Load (Not Ganged) | Maximum Load (End of Gang) | Maximum Load (Middle of Gang) |
---|---|---|---|---|---|---|---|
PD-10NXD, PD-10NXD-XX-C | Dimmer PRO (neutral connection required for certain load types)⁴ | 120 V~ | Incandescent/Halogen | 10 W with neutral (25 W without neutral) | 1000 W | 800 W | 600 W |
MLV Halogen | 10 W | 1000 VA | 800 VA | 600 VA | |||
MLV LED | See Application Note #559 (P/N 048559) at www.lutron.com | ||||||
LED (120 V~ Rated)³ | 1 bulb³ | 250 W | 250 W | 250 W | |||
Hi-lume 1% 2-Wire LED drivers | 1 driver | 13 drivers | 13 drivers | 13 drivers | |||
Dimmable Ballasts⁵ | 1 ballast | 1000 VA | 800 VA | 600 VA | |||
PHPM-PA/3F and GRX-TVI⁴ | 1 interface | 3 interfaces | 3 interfaces | 3 interfaces | |||
PD-3PCL, PD-3PCL-WH-C | Plug-In Lamp Dimmer | 120 V~ | Incandescent/Halogen | 10 W | 300 W | N/A | N/A |
LED (120 V~ Rated)³ | 1 bulb³ | 100 W | N/A | N/A | |||
PD-5NE | Phase Selectable Dimmer (neutral connection required) | 120 V~ | Incandescent/Halogen | 10 W | 500 W | 400 W | 300 W |
LED (120 V~ Rated)³,⁶,⁷ | 1 bulb³ | 250 W | 250 W | 250 W | |||
MLV Halogen²,⁶,⁷ | 10 W | 400 VA | 400 VA | 400 VA | |||
ELV Halogen | 10 W | 500 W | 400 W | 300 W | |||
Hi-lume 1% 2-Wire LED drivers²,⁶,⁷ | 1 driver | 20 drivers | 20 drivers | 20 drivers | |||
Dimmable Ballasts⁵,⁶,⁷ | 1 ballast | 400 VA | 400 VA | 400 VA | |||
PHPM-PA/3F and GRX-TVI²,⁷ | 1 interface | 3 interfaces | 3 interfaces | 3 interfaces | |||
ELV LED | See Application Note #559 (P/N 048559) at www.lutron.com | ||||||
MLV LED²,⁶,⁷ | See Application Note #559 (P/N 048559) at www.lutron.com | ||||||
DVRF-5NE | Phase Selectable Dimmer (neutral connection required) | 120 V~ | Incandescent/Halogen⁹ | 5 W | 500 W | 400 W | 300 W |
LED (120 V~ rated)³,⁶,¹⁰ | 1 bulb³ | 250 W | 200 W | 150 W | |||
MLV Halogen²,⁶,¹⁰ | 10 W | 400 VA | 400 VA | 400 VA | |||
ELV Halogen | 10 W | 500 W | 400 W | 300 W | |||
Hi-lume 1% 2-wire LED drivers²,⁶,¹⁰ | 1 driver | 20 drivers | 20 drivers | 20 drivers | |||
Dimmable Ballasts⁵,¹⁰ | 1 ballast | 400 VA | 400 VA | 400 VA | |||
PHPM-PA/3F and GRX-TVI²,¹⁰ | 1 interface | 3 interfaces | 3 interfaces | 3 interfaces | |||
ELV LED | See Application Note #559 (P/N 048559) at www.lutron.com | ||||||
MLV LED²,⁶,¹⁰ | See Application Note #559 (P/N 048559) at www.lutron.com | ||||||
PD-6WCL, DVRF-6L | Dimmer | 120 V~ | Incandescent/Halogen | 25 W | 600 W | 500 W | 400 W |
LED (120 V~ Rated)³ | 1 bulb³ | 150 W | 150 W | 150 W |
1 Cannot be ganged.
² Need to change phase selection to forward-phase. See www.casetawireless.com/change_phase
³ See bulb list at www.lutron.com/led
4 For PD-10NXD, a neutral connection is required for MLV loads, LED drivers, dimmable ballasts, and power modules (PHPM-PA, PHPM-3F, and GRX-TVI).
5 Compatible dimmable ballasts include Tu-Wire, Mark 10, and PowerSense.
6 Consult https://www.casetawireless.com/support to ensure the appropriate phase for bulb models used.
7 SSL7 compliant when in forward-phase.
8 Available in WH only.
9 Reverse-phase only.
10 SSL7 compliant when in forward-phase up to 50 W.
Ganging and Derating
When ganging with other switches/dimmers in the same wallbox, derating is required. Refer to the "Load Type and Capacity" charts.
Original Smart Models
Diagrams show that for ganged switches/dimmers, outside fins on the ends of devices should not be removed, while inside fins on ganged devices and all fins on middle devices must be removed. PD-5WS-DV models ship without fins, so fin removal is not applicable.
Diva and Claro Smart Models
DVRF- models do not have fins, but derating may still be required. Consult the "Load Type and Capacity" charts.
Operation
Original Smart Models
Switches
Features a Status LED that indicates load status, glowing softly as a night light when the load is off. The control has an 'On' and 'Off' state.
Dimmers
Features Status LEDs indicating load status, glowing softly as a night light when the load is off. Controls include 'On', 'Brighter', 'Darker', and 'Favorite' (user-defined favorite light level, available in PD-5NE models).
Plug-In Dimmer
Features a Status LED indicating load status, glowing softly as a night light when the load is off. Controls include 'On', 'Brighter', and 'Darker'.
Fan Control
Features Status LEDs indicating load status, glowing softly as a night light when the fan is off. Controls include 'High', 'Faster', 'Preset' (user-defined favorite fan speed), 'Slower', and 'Off'.
FASS - Front Accessible Service Switch
All models include a FASS. Important Notice: To service the load, pull out the FASS as far as possible. To restore power after servicing, push the FASS back in completely.
Diva and Claro Smart Models
Dimmer
Controls include 'On' (lights go to full), 'Off' (lights go to preset), a soft-glow light bar for adjusting light level (will not turn lights off), and a press-and-hold function for delayed fade-to-off.
Switch
Features a Status LED indicating load status. Controls include 'On' and 'Off'.
Accessory Switch
Controls include 'On' (lights go to full), 'Off' (lights go to preset), and a press-and-hold function for delayed fade-to-off.
Mounting
Installation involves a wallbox, switch/dimmer, switch/dimmer mounting screws, wallplate adapter, and wallplate. Wallplate adapters and wallplates are sold separately. Claro Wallplates (CW-1) are shown as an example. Note: Fin removal is not required for PD-5WS, DVRF-6L, DVRF-5NS, DVRF-5NE, and DVRF-AS as they ship without fins.
Dimensions
Original Smart Models
Switches and Dimmers
Front View: 4¹⁄₁₆ in (119 mm) height, 2¹⁵⁄₁₆ in (75 mm) width. Side View: 1¹⁄₈ in (30 mm) depth.
Fan Control
Front View: 4¹⁄₁₆ in (119 mm) height, 2¹⁵⁄₁₆ in (75 mm) width. Side View: 1¹⁄₁₆ in (39 mm) depth.
Plug-In Dimmer
Front View: 3¹⁄₈ in (79 mm) height, 2³⁄₁₆ in (56 mm) width. Side View: 1³⁄₁₆ in (30 mm) depth.
Diva and Claro Smart Models
Dimmer
Front View: 4¹⁄₁₆ in (119 mm) height, 2¹⁵⁄₁₆ in (75 mm) width. Side View: 2¹⁄₁₆ in (65 mm) depth.
Switch
Front View: 4¹⁄₁₆ in (119 mm) height, 2¹⁵⁄₁₆ in (75 mm) width. Side View: 1¹⁄₈ in (30 mm) depth.
Accessory Switch
Front View: 4¹⁄₁₆ in (119 mm) height, 2¹⁵⁄₁₆ in (75 mm) width. Side View: 2⁹⁄³₂ in (58 mm) depth.
Wiring Diagrams
The document provides detailed wiring diagrams for various installation scenarios. These include:
Switches
- Single Pole Installation (load controlled from 1 location)
- 3-Way Installation (load controlled from 2 locations) with mechanical switch, Pico remote controls, or accessory switch.
- Multi-location Installation (load controlled from 3 or more locations) with Pico remote controls or accessory switches.
Dimmers
- Single Pole Installation (load controlled from 1 location)
- 3-Way Installation (load controlled from 2 locations) with mechanical switch, Pico remote controls, or accessory switch.
- Multi-location Installation (load controlled from 3 or more locations) with Pico remote controls or accessory switches.
- Installation With Power Interfaces and LED Drivers - Neutral Required (Options: PHPM, GRX-TVI, Hi-lume 1% 2-wire LED Drivers).
Fan Controls
- Single Pole Installation (load controlled from 1 location)
- 3-Way Installation (load controlled from 2 locations) with Pico remote controls.
Colors and Finishes
Available finishes include:
- Gloss Finishes: White (WH), Black (BL), Ivory (IV), Light Almond (LA), Gray (GR), Brown (BR).
Due to printing limitations, colors and finishes shown cannot be guaranteed to perfectly match actual product colors.
PD- models of Caséta dimmers are only available in WH, BL, IV, and LA. DVRF- models are available in all six colors.