Instruction Manual for EPEVER models including: 51.2V 212Ah Solid State Lithium Battery, 51.2V 212Ah, Solid State Lithium Battery, State Lithium Battery, Lithium Battery, Battery

hujj

Download File

51.2V 212Ah Solid-state Lithium Battery - EPEVER


File Info : application/pdf, 27 Pages, 670.42KB

PDF preview unavailable. Download the PDF instead.

LFP10.85KWH51.2V-P65F1QT50-Manual-EN-V1.0
LiFePO4 (LFP) Battery Product manual
LFP10.85KWH51.2V-P65F1QT50

Contents
1 Important Safety Instructions ........................................................ 1 2 General Information ........................................................................ 3
2.1 Appearance ....................................................................................................................... 3 2.2 Product size ...................................................................................................................... 4
3 Basic Information ............................................................................ 5
3.1 Interface definition ............................................................................................................5 3.2 Product features ............................................................................................................... 6 3.3 LED Indicator .................................................................................................................... 7
4 Instructions ......................................................................................8
4.1 Packing list ........................................................................................................................8 4.2 Installation requirements ................................................................................................. 9 4.3 Charging operation .........................................................................................................15 4.4 Discharge operation ....................................................................................................... 15 4.5 Description of battery parallel capacity and voltage .................................................. 16
5 Protection Features .......................................................................17 6 Specifications ................................................................................ 22 7 Precautions ....................................................................................23
7.1 Maintenance precautions ...............................................................................................23
8 Disclaimers .................................................................................... 24

1 Important Safety Instructions
 Thank you for choosing EPEVER Lithium Iron Phosphate (LFP) battery, please read this manual carefully before using this product.  It is strictly forbidden to install this product in harsh environments such as moisture, salt spray, corrosion, greasy, flammable and explosive, or a large amount of dust accumulation.  Please keep this product manual for future reference.
Precautions for work and storage
a) Please keep the battery in a cool, dry place. The environment should be free of corrosive, explosive and insulation-damaging gases or conductive dust, and away from fire and heat sources and high pressure; It is forbidden to immerse the battery in water; Keep out of reach of children; Pay attention to anti-static electricity (static electricity may damage the battery protection circuit, causing battery damage).
b) The battery should be safely fixed in a reasonable use of the environment, the connector must be reliably connected to avoid contact friction caused by arc and sparks.
c) When handling the battery, please handle it gently to avoid mechanical vibration, collision and pressure shock.Otherwise, it may cause internal short circuit of the battery, resulting in high temperature and fire.
d) Do not short-circuit the positive and negative poles of the battery, and do not disassemble or assemble the battery to avoid danger.
e) Please keep the battery in a semi-charged state (40%~80% SOC is appropriate). Please wrap the battery with non-conductive materials to avoid direct metal contact with the battery, which may cause battery damage.
f) Please dispose of waste batteries safely and properly, and do not put them into fire or liquid. g) This battery cannot be used in series.
Danger warning a) It is strictly forbidden to crush, drop, collide, puncture, burn and other destructive behaviors on the
battery. b) It is forbidden to disassemble and assemble the battery. Improper disassembly and assembly may
damage the protective function of the battery, resulting in deformation, heating, smoke or combustion of the battery. c) It is forbidden to short circuit the battery. It is prohibited to connect the positive and negative electrodes of the battery with conductive materials; Do not store or transport the battery with the conductor to avoid battery damage due to short circuit
1

d) It is forbidden to heat and incinerate batteries. It may melt battery components, lose safety features, or burn electrolyte. Overheating can deform, heat, smoke, or burn the battery. Emergency treatment method
a) When the electrolyte leaks, avoid skin and eye contact with the electrolyte. In case of contact, wash immediately with plenty of water and seek help from a doctor. It is forbidden for any person or animal to swallow any part of the battery or the substances contained in the battery.
b) b) If the battery is seriously deformed or the electrolyte leaks due to collision and extrusion, the battery should be placed in the explosion-proof box or an open place, and the personnel should be evacuated quickly if conditions permit,.
c) If the battery catches fire during use or storage, use a high-pressure water cannon to extinguish the fire under the condition of ensuring personal safety.
d) d) If the battery catches fire during charging, be sure to turn off the charger as soon as possible before executing the next fire extinguishing action.
2

2 General Information
2.1 Appearance

Front

Side

Black

A B C
D&E&K&M
F&N G&O
H

Battery SOC indicator

I

Malfunction indicator

J

Running indicator

L

P Metal handle

Negative connector

Q

Positive connector

R

Inverter communication interface

Side
Parallel communication interface Weak-current switch
Grounding screw interface PC upper computer communication
interface Parallel communication interface
Pressure reducing value

3

2.2 Product size
4

3 Basic Information

3.1 Interface definition

(1) The RS232 communication interface pin are defined as follows, and the RJ11 communication interface is used to connect the upper computer of the lithium battery PC.

RJ11 Pin 126

RJ11 Definition NC

3

TX

4

RX

5

GND

( RJ11)

(2) The pins of the CAN/RS485 communication interface are defined as follows, and the RJ45

communication interface is used for the communication connection between the lithium battery and

the inverter host.

Pin No 1 2 3 4 5 6 7 8

RJ45 Definition RS485-B RS485-A GND CAN-H CAN-L NC RS485-A RS485-B

(RJ45 )

(3) The DIP communication interface pin is defined as follows: RJ45 communication interface is used for parallel communication between lithium battery and lithium battery parallel machine.

Pin No 1 2 3 4 5 6 7 8

RJ45 Definition RS485-B RS485-A GND GND OP+ NC RS485-A RS485-B

(RJ45 )

5

(4) The BMS communication interface pins are defined as follows, and the RJ45 communication interface is used for the communication connection between lithium battery and lithium battery parallel machine.

Pin No 1 2 3 4 5 6 7 8

RJ45 Definition RS485-B RS485-A GND GND UP-IN NC RS485-A RS485-B

(RJ45 )

3.2 Product features
 It has the function of single voltage and overall voltage detection, over-voltage and under-voltage alarm and protection
 It has the functions of charge and discharge current detection, alarm and protection  It has the function of cell, environment and PCB temperature detection, and can alarm and protect
when charging and discharging at high and low temperature  It has the function of detection and protection of output short circuit  With the battery SOC calculation, charge and discharge cycle calculation function  With a charge balancing function, reduce the charging current of the high-voltage cell (the reduced
current is the balance current set by the BMS)  With LED indicator function, indicating the current battery SOC, battery fault status, operating status,
etc  BMS manual and automatic sleep function  With charge current limiting function  With history storage function (not less than 500 storage capacity)  With RS485 communication function, real-time monitoring of BMS and battery status  The two-stage over-current protection function of discharge has different response speed to different
current values, which protects the battery more reliably.

6

3.3 LED Indicator
The L1 to L10 of the LED indicator corresponds to the position where the SOC of the battery is 0% to 100%, as shown in the following diagram:

 A total of 12 LED lights on the light board, each light can display red, yellow, blue, green and other colors. It is divided into 3 categories according to the use of the light:

Light

State

Description

Normal state Green light : on solid

Run-led

Charging state Green light : flashing(1Hz) Discharge state Green light : flashing(1Hz)

Alarm-led
Power indicator
light
Power On Self Test
Dormancy

Normal state Alarm state
Protection state
Invalid/failure state
Charging state Discharge state
Normal state

No alarm or no protection status: off
Yellow light : flashingOver-voltage and under-voltage do not make alarm indications, and do not flash yellow lights
Red light : flashing
Red light : on solid
Blue light: indicates the power level
Green light: battery statuslow batteryflashing Flashing frequency: 2 times/second
The self-test status of led (red, blue, green) is as follows:  Red running light: The red display increases sequentially from
the battery indicator Led-01. After the LED light is fully on, it will be completely turned off and enter the next round;  Blue running light: The blue display increases sequentially from the battery indicator Led-01. After the LED light is fully on, it will be completely turned off and enter the next round;  Green running light: The green display increases sequentially from the battery indicator Led-01. After the LED light is fully on, it will be completely turned off and enter the next round;
All LED lights: off

7

4 Instructions
4.1 Packing list
Before unpacking, please check the outside of the battery for damage to the packaging and check the model of the battery. If there is any abnormality, please do not open the package and contact the after-sales service center as soon as possible. After unpacking the battery, please check whether the product is complete according to the packaging information. If you have any questions, please contact the after-sales service center as soon as possible.

X1 Lithium battery

X1
Fasteners strips for installation against a wall

X2
Fasteners pieces for installation against a wall

X1 Positive output power cable

X1 Negative output power cable

X2 RNB60-8 wiring terminal

X1 Positive connector quick plug

X1 Negative connector quick plug

X2 M8×60 expansion bolt

X1 Battery pack parallel communication cable

X1 RS485 communication cable

X1 USB-A to RS232 communication
cable

X12 M6×14 bolt group

X2 M8×16 bolt group
8

4.2 Installation requirements
a. Space installation distance Master and check the performance of all tools and devices to ensure safety before using them. The left and right distance between battery packs is recommended. Minimize the distance as much as possible.
b. Installation environment  The battery works best at 20~40°C.  Avoid installation in environments with direct high temperature and rain.  Avoid installation close to high temperature heat source or low temperature cold source.  Avoid installation in places where the ambient temperature changes drastically.  Avoid installation in strong interference environments.  Avoid installation in places where children can enter.  Avoid installation in places where water is likely to accumulate.  It is forbidden to place flammable and explosive materials around the equipment.
9

c. Prepare tools

Hammer Drill

Rubber Hammer

Claw Safety Hammer

Insulated Cross Screwdriver

Insulated Slotted Screwdriver

Spirit Level

Tape Ruler

Insulation Tape

Dustproof Cover

Protective Glasses

Utility Knife

Wire Stripper

Diagonal Pliers

MC4 Crimper

Multimeter

AC/DC Clamp-On Ammeter

Marker Pen

Electric Screwdriver

10

d. Space installation requirements 1. Place the wall fixing strip close to the wall (level correction), mark the screw holes with a marker pen with reference to the size shown in the diagram, and then remove the wall fixing strip.
2. Use a hammer drill to drill a hole in the wall (diameter:10mm, depth: 65mm), insert the M8 expansion screw and tighten it.
3. As shown in Figure 3, the M6X14 locking fastener fittings are used respectively. After completion, it is shown in Figure 4.
11

4. Move the stacked and fixed lithium battery packs to the position shown in Figure 6, align the fixing strips against the wall, move them horizontally, and affix the fixing strips. As shown in Figure 7, use two M6X14 screws to lock the lithium battery pack from both sides. The final completion is shown in Figure 8.
12

e. Wiring diagram

PoPsoitisvietivoeuotpuutpt uptopwoewr elirnecable (1500mm) NeNgeagtiavetivoeuotpuutpt uptopwoewr elirnecable (1500mm) RSR4S8458c5ocmommumnuicnaictiaotniolninecable (1500mm) LitLhituhmiumbabttaetrtyerpyopsoitisvietivpeapraalrlaelleplopwoewr elirnecable LitLhituhmiumbabttaetrtyernyengeagtiavteivpeapraalrlealleplopwoewr elirnecable LitLhituhmiumbabttaetrtyerpyapraalrleallecol cmommumnuicnaictiaotniolnineca(DbIleP~(DBIMPS~B) MS)

(1200mm)

13

Positive output power cable (1500mm) Negative output power cable (1500mm) RS485 communication cable (1500mm)
Warning
1. For operational safety and compliance, please disconnect the communication and cable link with the inverter when storing the battery. 2. During the handling and installation of the battery, it is recommended to wear safety helmets, goggles, protective shoes and other safety equipment suitable for the work to prevent accidental injury; 3. All wiring must be carried out by professionals. With the right cables, the battery connection is essential for the safe and efficient operation of the system. In order to reduce the risk, please use the cable provided by our company, or our recommended cable specifications.
14

4.3 Charging operation
1. Check before charging.  Inspect the appearance of the battery and inverter or other connected equipment to ensure that the power cord and all wiring harnesses are connected.  Make sure the power supply meets the specification requirements for the battery.
2. Turn off the inverter or other equipment, connect the positive and negative terminals of the battery, and connect the communication cable normally.
Warning: Before connecting the battery, ensure that the positive and negative terminals are connected. Do not reverse connect. 3. Connect the charger to the power supply and turn on the charger. 4. Start the battery, the POWER indicator is on, and the SOC indicator flashes to start charging normally.  Standard Charging: First, charge the battery to 57.6V with a constant current of 40A (0.2C), and then charge to 10A (0.05C) with a constant voltage of 57.6V. Note: All tests stated in this document shall be performed at 25±2.
4.4 Discharge operation
1. Before discharging, check whether the load and equipment are turned off. 2. Properly connect the positive and negative terminals of the battery to the load/inverter or other equipment.
Warning: Before connecting the load and equipment, please confirm the positive and negative wiring of the battery, and prohibit reverse connection. 3.Turn on the load/inverter or other device. 4. Start the battery. The POWER indicator is steady on, the RUN indicator is on for 0.5 seconds, and the discharge starts for 1.5 seconds. Standard discharge After the battery is standard charged, discharging the battery with a constant current of 40A (0.2C) till the battery voltage drops to 41.6V. Note: All tests stated in this document shall be performed at 25±2.
Precautions for charging and discharging operation
a) When the temperature is high ( 35 °C) in summer, the battery should not be charged more than 0.5C during the day, and it is recommended to stand for more than 30 minutes in the middle of the charge-discharge conversion to avoid the battery being used often in a high-temperature environment (a high-temperature environment will affect the battery life).
b) When the temperature is low (<0 ° C) in winter, the depth of battery discharge <70% to avoid over-discharge of the battery caused by too low temperature and affect the battery life. Warning: This lithium battery should only be used with a manufacturer or
manufacturer-matched compatible inverter or other equipment. When the lithium battery does not communicate with the inverter or other equipment, it is forbidden to use the lithium battery.
15

4.5 Description of battery parallel capacity and voltage

Capacity
424Ah 636Ah 848Ah 1060AH 1272Ah 1484Ah
1696Ah

Number of battery
parallel groups
2 groups 3 groups 4 groups 5 groups 6 groups 7 groups
8 groups

Maximum charging voltage
57.6V 57.6V 57.6V 57.6V 57.6V 57.6V
57.6V

Discharge cut-off voltage 41.6V 41.6V 41.6V 41.6V 41.6V 41.6V
41.6V

16

5 Protection Features

No
Cell overcharge protection 1
Cell over-voltage protection release

Item Cell overcharge alarm voltage Cell overcharge protection voltage Cell overcharge protection delay Cell overcharge protection voltage SOC release Discharge release

Factory default parameter

Set state

3600mV

settable

3650mV

settable

1.0S

settable

3380mV
SOC96% Discharge current2A

settable settable

Cell over-discharge

3380mV

alarm voltage

Cell

Cell over-discharge

over-discharge

3380mV

protection voltage

protection

2

Cell over-discharge

1.0S

protection delay

settable settable settable

Cell over-discharge release

Cell over-discharge protection release voltage Release on charge

2950mV

settable

Plug in the charger to activate

Battery overcharge protection
3

Battery overcharge alarm voltage Battery overcharge protection voltage Battery overcharge protection delay

57.6V 58.4V 1.0S

settable settable settable

Battery overcharge protection release

Battery overcharge protection release voltage
SOC release Discharge release

54V
SOC96% Discharge current2A

settable settable

17

Postscript

Battery

over-discharge

44.8V

settable

alarm voltage

Overall over-discharge protection

Battery over-discharge protection voltage Battery

4

over-discharge

protection voltage

43.2V 1.0S

settable settable

delay

Battery over-discharge protection release

Battery over-discharge protection release voltage Release on charge

47.2V

settable

Plug in the charger to activate

Charging

over-current alarm 105A

settable

current

Charge

Charging

over-current

over-current

110A

settable

protection

protects the current

5

Charging

over-current

1.0S

settable

protection delay

Charge

Automatic release Automatically disconnects after 1mins

over-current protection

Discharge release Discharge current1A

release

Discharge

over-current 1

105A

settable

Discharge

alarm current

over-current 1 Discharge

6 protection

over-current 1 Protects current

110A

settable

18

If the status is locked for 10 consecutive times, it cannot be automatically unlocked
Appearing 10 times in a row will lock the state and will no longer be automatically disconnect

Discharge over-current 1 protection release Discharge over-current 2 Discharge 7 over-current 2 protection release
8 Short circuit protection
MOS high 9 temperature
protection
10 Cell temperature protection

Discharge over-current 1 Protection delay Automatic disconnect

1.0S

settable

Automatically disconnects after 1 minute

Charge disconnect
Protection current Protection delay

Discharge current > 1A 150A 500mS

settable settable

Automatic disconnect

Automatically disconnects after 1 minute

Charge disconnect Short-circuit protection function
Short-circuit release
Alarm temperature Protective temperature Release temperature Charge low temperature alarm Charge low temperature protection Charge low temperature protection release Charging high temperature alarm

Discharge current > 1A

Available

When there is charging, the short circuit

protection is removed

After the load is removed, it is automatically

removed

90°C

settable

115°C

settable

85°C

settable

5

settable

0

settable

5 60

settable settable

It can be set 10 consecutive occurrences to lock the state without automatically disconnecting

19

Ambient 11 temperature
alarm

Charging high temperature protection Charge high temperature protection release Discharge low temperature alarm Low temperature discharge protection Discharge low temperature protection release High discharge temperature alarm Discharge high temperature protection Discharge high temperature protection release Ambient low temperature alarm Ambient low temperature protection
Environmental low temperature protection release
Ambient high temperature alarm

65 55 -15 -20 -15 65 70
60 -15 -20 -15 65

20

settable settable settable settable settable settable settable
settable settable settable settable settable

Ambient high temperature protection

75

settable

Ambient high temperature

65

settable

protection release

12 Low battery alarm

Low battery alarm condition

SOC5%

settable

No alarm when charging

Sleep voltage

3150mV

settable

Delay time

5min

settable

13 Sleep function

Cell voltage difference

voltage difference1V

settable

Charging and discharging are not allowed

Full charge voltage 56V

settable

When both conditions are met,

14 Full charge

Cut-off current

2A

settable

stop charging and update the SOC to

100%

(Note: Unless otherwise specified, the above parameters are tested at 25°C ambient

temperature.)

21

6 Specifications

Parameter Battery Type Nominal Voltage

LFP10.85KWH51.2V-P65F1QT50 LiFePO4 51.2V

Nominal Capacity Energy

212Ah 10854Wh

Continuous Discharge Current

100A

Charge Cut-off Voltage

57.6V

Discharge Cut-off Voltage

41.6V

Maximum Charge Current

100A

Maximum Discharge Current Peak Discharge Current

200A@30min 240A@10S

Recommend Discharge Current

100A

Open-circuit Voltage

50.88~53.6V

Communication

RS485 RS232 CAN

Display Cycle Life

LED >5000 times (0.5C charge&discharge 80%DOD @25)

Number of series/parallel

Max 8 battery packs in parallel

Certification

UN38.3 MSDS IEC62619 ROHS

Charge&Discharge Temperature

Charge: 0~+55 Discharge: -20~+55

-5~+0/35~+45 (2month);

Storage Temperature Range

5~+35 (3 months, Optimum storage temperature); 15~+35 (6 months)

Relative Humidity Connect Terminal

60%±20% RH Quick-plug

Dimension (L x W x H)

601mm x 160mm x 885mm

Net Weight

100.7±0.5kg

IP Class

IP65

Warranty

3 years (See warranty agreement for details)

 Repeat the operation method of standard charging and standard discharge 3 times, and take

the third result as the initial capacity of the battery.

 When the battery is stored for more than 3 months, the storage voltage should be maintained

at 52~53.6V

 For long-term storage, charge at least once every 3 months (no less than 30 minutes@0.2C).

22

7 Precautions
7.1 Maintenance precautions
Item If the battery is not in use, it needs to be fully charged and discharged to 50%.
Check whether the wall bracket installation is loose. Please tighten the appropriate position if available.
Check the casing for damage. If damaged, please repaint or contact after-sales service center. Check exposed wires for wear and tear. If the cable is worn, replace the appropriate cable or contact the service center. Check for debris buildup around the battery. Clean it to prevent heat dissipation of the battery.
Check water or pests to avoid long-term intrusion and damage to the battery.

Cycle 3 months 6 months 6 months 6 months 6 months 6 months

Warning
1. If you find any problems that may affect the battery or the battery and energy storage system, please contact the after-sales service department, disassembly is strictly prohibited. 2. If you find that the copper wire inside the conductive wire is exposed, please strictly prohibit touching it due to the danger of high voltage. Please contact the after-sales personnel, disassembly is strictly prohibited. 3. If there are other emergencies, please contact the after-sales personnel first, operate under the guidance of the after-sales personnel, or wait for the after-sales personnel to operate on site.

23

8 Disclaimers
The warranty does not apply to the following conditions:  Damage caused by improper use or inappropriate environments (It is strictly forbidden to install the
Energy Storage System in the humid, salt spray, corrosive, greasy, flammable, explosive, dust accumulative or other harsh environments).  The actual current/voltage/power exceeds the limit value of the Energy Storage System.  Damage caused by working temperature exceeding the rated temperature range.  Electric arc, fire, explosion and other accidents caused by failure to follow the Energy Storage System labels or manual instructions.  Unauthorized disassembly and maintenance of the Energy Storage System.  Damage caused by force majeure such as lightning strikes, rainstorms, mountain torrents and Utility failures.  Damage occurred during transportation or loading/unloading the Energy Storage System.
Any changes without prior notice! Version number: V1.0
24

HUIZHOU EPEVER TECHNOLOGY CO., LTD BeiJing Service Hotline010-82894896/82894112 Huizhou Service Hotline0752-3889706 Shenzhen Service Hotline0755-89236770 E-mailsales@epever.com Websitewww.epever.com.cn
25



References