Buderus G115 & G115WS Boilers
Technical Specifications and Setup Data
Riello Burner Specifications
Boiler Model | Input BTU/HR | Vent System | Burner Model | Insertion Depth | Firing Rate GPH | Burner Part No. | Air Tube Comb. | Head Setting | Specified Nozzle Type/Brand | Alternate Nozzle Type/Brand | Pump Pressure PSI | Breech Press W.C. | Over-fire Press W.C. Based on Breech Press W.C. Shown | Air Setting gate | Appx Gross Stack Temp. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
G115WS Series - Upfired | |||||||||||||||
G115WS/3 | 105000 | Chimney | R40 F3 | 6" | 0.75 | C8511443 | LBT* | 2 | Del. 0,60 x 60°B | Del. 0,60 x 60°W | 145 | 0 to -0,03 | 0 to Slightly + 4.00 | 350°F | |
G115WS/4 | 126000 | Chimney | R40 F5 | 6" | 0.90 | C8512543 | LBT* | 1 | Del. 0,75 x 60°B | Del. 0,75 x 60°A | 145 | 0 to -0,03 | 0 to Slightly + 2.50 | 326°F | |
G115WS/5 | 161000 | Chimney | R40 F5 | 10" | 1.15 | C8512443 | LBT* | 3 | Del. 0,85 x 60°B | Del. 0,85 x 60°A | 165 | 0 to -0,03 | 0 to Slightly + 3.00 | 325°F | |
G115 Series - Chimney Vent | |||||||||||||||
G115/21 | 84000 | Chimney | R40 F3 | 6" | 0.60 | C8511443 | LBT* | 0 | Del. 0,50 x 60°B | Del. 0,50 x 70°A | 145 | 0 to -0,03 | 0 to Slightly + 2.25 | 289°F | |
G115/28 | 112000 | Chimney | R40 F5 | 6" | 0.80 | C8512543 | LBT* | 0 | Del. 0,65 x 60°B | Del. 0,65 x 60°W | 145 | 0 to -0,03 | 0 to Slightly + 2.25 | 297°F | |
G115/34 | 140000 | Chimney | R40 F5 | 10" | 1.00 | C8512443 | LBT* | 2 | Del. 0,85 x 60°B | Del. 0,85 x 60°W | 145 | 0 to -0,03 | 0 to Slightly + 2.50 | 284°F | |
G115 Series - Direct Vent | |||||||||||||||
G115/21 | 84000 | Direct vent | R40 BF3 | 6" | 0.60 | C8511343 | LBT* | 0 | Del. 0,50 x 60°W | Del. 0,50 x 60° B | 145 | N/A | N/A | 3.50 | 316°F |
G115/28 | 112000 | Direct vent | R40 BF3 | 6" | 0.80 | C8511344 | LBT* | 3 | Del. 0,65 x 60°W | Del. 0,65 x 60°B | 145 | N/A | N/A | 5.50 | 304°F |
G115/34 | 140000 | Direct vent | R40 BF5 | 10" | 1.00 | C8512343 | LBT* | 3 | Del. 0,85 x 60°W | Del. 0,85 x 60°B | 145 | N/A | N/A | 4.50 | 310°F |
Carlin Burner Specifications
Boiler Model | Input BTU/HR | Vent System | Burner Model | Firing Rate GPH | Burner Part No. | Air Tube Comb. | Head Setting | Specified Nozzle Type/Brand | Alternate Nozzle Type/Brand | Pump Pressure PSI | Breech Press W.C. | Over-fire Press W.C. Based on Breech Press W.C. Shown | Air Setting Air Band Air Boot | Stack Temp. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
G115WS Series | ||||||||||||||
G115WS-3 | 105,000 | Chimney | EZ-1HP | 0.76 | 9748611J21 | 5" EZ-1 | .60/.65 | .60-60B Delavan | .60-60W Delavan | 160 | -0.03 | Slightly + | 0.60 | 390-440°F |
G115WS-4 | 133,000 | Chimney | EZ-1HP | 0.95 | 9748611J28 | 5" EZ-1 | 0.75 | .75-60B Delavan | .75-60B Hago | 160 | -0.03 | Slightly + | 0.75 | 390-440°F |
G115WS-5 | 170,000 | Chimney | EZ-1HP | 1.16 | 9748611J34 | 5" EZ-1 | 0.75 | 0.85-60B Hago | 0.85-60B Delevan | 185 | -0.03 | Slightly + | 1.00 | 400-460°F |
G115 Series - Chimney Vent | ||||||||||||||
G115-21 | 84,000 | Chimney | EZ-1HP | 0.61 | 9748611J21 | 5" EZ-1 | 0.50 | .50-70A Delavan | .50-60W Delavan | 150 | -0.03 | Slightly + | 0.50 | 330-360°F |
G115-28 | 112,000 | Chimney | EZ-1HP | 0.80 | 9748611J28 | 5" EZ-1 | .60/.65 | .65-60ES Hago | .65-70A Delavan | 150 | -0.03 | Slightly + | 0.65 | 340-370°F |
G115-34 | 140,000 | Chimney | EZ-1HP | 1.04 | 9748611J34 | 5" EZ-1 | .85/1.00 | .85-60B Delavan | .85-60W Delavan | 150 | -0.03 | Slightly + | 0.85 | 380-420°F |
G115 Series - Direct Vent | ||||||||||||||
G115-21 | 84,000 | Direct Vent | EZ-1HP | 0.61 | 9748512J21 | 5" EZ-1 | 0.50 | .50-70A Delavan | .50-60ES Hago | 150 | N/A | N/A | 0.50 | 330-360°F |
G115-28 | 112,000 | Direct Vent | EZ-1HP | 0.80 | 9748512J28 | 5" EZ-1 | .60/.65 | .65-60ES Hago | .65-60A Delavan | 150 | N/A | N/A | 0.75 | 340-370°F |
G115-34 | 140,000 | Direct Vent | EZ-1HP | 1.04 | 9748512J34 | 5" EZ-1 | .85/1.00 | .85-60B Delavan | .85-60W Delavan | 150 | N/A | N/A | 1.00 | 380-420°F |
Carlin Electrode Settings
Electrodes Settings | Up | Ahead | Gap |
---|---|---|---|
EZ-1, 2, 3 | 5/16 | Flush to 1/16 | 1/8 - 5/32 |
Beckett Burner Specifications
Boiler Model | Input BTU/HR | Vent System | Burner Model | Firing Rate GPH | Burner Part Number | Air Tube Combina- tion | Head Setting | Specified Nozzle Type/Brand | Alternate Nozzle Type/Brand | Pump Pressure PSI | Breech Press W.C. | Over-fire Press W.C. Based on Breech Press W.C. Shown | Air Setting Shutter | Air Setting Band | Stack Temperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
G115WS Series - Chimney Vent - NX | |||||||||||||||
G115WS\3 | 105,000 | Chimney | NX1 | 0.75 | BU2304 | NX70LC3 | 2.5 | 0.60x60°W Delavan | 0.60x60°W Hago | 150 | -.04 | .015 | N/A | N/A | 412 |
G115WS\4 | 133,000 | Chimney | NX | 0.95 | BU2305 | NX70LC3 | 3.25 | 0.75x60°B Hago | 0.75x60°B Delavan | 165 | -.045 | .025 | N/A | N/A | 406 |
G115WS\5 | 161,000 | Chimney | NX | 1.15 | BU2306 | NX70LB3 | 4.00 | 0.85x60°W Delavan | 0.85x60°W Hago | 175 | -.04 | .03 | N/A | N/A | 387 |
G115 Series - Chimney Vent - NX | |||||||||||||||
G115\21 | 84,000 | Chimney | NX1 | 0.60 | BU2301 | NX70LC3 | 1 | 0.50x60°W Delavan | 0.50x60°AS Danfoss | 150 | -.03 | .035 | N/A | N/A | 379 |
G115\28 | 112,000 | Chimney | NX1 | 0.80 | BU2302 | NX70LC3 | 2.5 | 0.60x60°B Delavan | 0.60x60°B Hago | 175 | -.035 | .025 | N/A | N/A | 319 |
G115\34 | 140,000 | Chimney | NX | 1.00 | BU2303 | NX70LB3 | 2.25 | 0.75x60°B Delavan | 0.75x60°B Hago | 175 | -.025 | .045 | N/A | N/A | 330 |
G115 Series - Direct Vent - NX | |||||||||||||||
G115\21 | 84,000 | Direct Vent | NX1 | 0.60 | BU2301 | NX70LC3 | 1 | 0.50x60°W Delavan | 0.50x60°AS Danfoss | 150 | .005 | .065 | N/A | N/A | 417 |
G115\28 | 112,000 | Direct Vent | NX1 | 0.80 | BU2302 | NX70LC3 | 2.5 | 0.60x60°B Delavan | 0.60x60°B Hago | 175 | .035 | .09 | N/A | N/A | 418 |
G115\34 | 140,000 | Direct Vent | NX | 1.00 | BU2303 | NX70LB3 | 2.25 | 0.75x60°B Delavan | 0.75x60°B Hago | 175 | .04 | .135 | N/A | N/A | 412 |
G115 Series - Chimney Vent - AFG | |||||||||||||||
G115\21 | 84,000 | Chimney | AFG1 | 0.60 | BU2101 | AFG90M- PASN2 | N/A | 0.50x45°B Hago | 0.50x60°B Hago | 150 | -.02 | .03 | 9 | 0 | 349 |
G115\28 | 112,000 | Chimney | AFG | 0.80 | BU2102 | AFG90M- PASN2 | N/A | 0.65x60°B Hago | 0.65x60°B Delavan | 150 | -.02 | -.01 | 8 | 0 | 302 |
G115\34 | 140,000 | Chimney | AFG | 1.00 | BU2103 | AFG90M- PASN2 | N/A | 0.85x60°B Hago | 0.85x60°B Delavan | 140 | -.035 | .07 | 10 | 2 | 398 |
Beckett Footnotes
Note | Description |
---|---|
1 | Low fire baffle installed |
2 | Electrode tip settings: 1/4” above nozzle center line; 1/8” in front of nozzle; 1/8” gap; ‘Z” dimension 1-3/4”; 6-1/4” insertion depth |
3 | 4-7/8" insertion depth |
General Notes and Setup Information
* Reverse air flow turbolator disk
Actual operating setting on the burner may differ from factory settings. Adjust burner settings to obtain a #0 smoke reading with a CO2 value of 11% - 12%
Direct vent models: Drafts pressures will vary due to job site locations.
This data sheet is intended to be a setup guide. It is critical that all oil fired heating equipment be installed using combustion efficiency test equipment.