Instruction Manual for Godox models including: MG2400Bi, MG2400Bi K1, MG2400Bi K2, MG2400Bi LED Bi Color LED Light, MG2400Bi, LED Bi Color LED Light, Color LED Light, LED Light, Light

合格证

19 nov 2024 — Instruction Manual Version: V1.1. Controller Firmware Version: V0.13. Lamp ... 1.4 Install the light on the roller stand and lock the fixing knob on the roller ...


File Info : application/pdf, 34 Pages, 10.70MB

PDF preview unavailable. Download the PDF instead.

1731998486108084
QC PASS

Wechat Official Account


V1.1 V0.13 V0.03

Instruction Manual Version: V1.1 Controller Firmware Version: V0.13 Lamp Head Firmware Version: V0.03

 : 2 : 0755-25723423 : godox@godox.com

: 0755-29609320(8062)

GODOX Photo Equipment Co.,Ltd. Add.: Building 2, Yaochuan Industrial ZoneTangwei Community, Fuhai Street, Bao'an District, Shenzhen 518103, China Tel: +86-755-29609320(8062) Fax: +86-755-25723423 E-mail: godox@godox.com

godox.com Made in China 705-MG24B0-03

LED KNOWLED Bi-color LED Light
 Instruction Manual


 
1.  2. 
 3. 
 4. LED 5. 
 6. 
 7. 20~45 8.  9. 
 10. 
 11. 
  12.    13.  14.   15.  16.  17.  18.  19. ROHSCEFCC 20.   21. -- 22.  23. 

01


  LED  MG2400Bi 2900W 100V-240V~50/60Hz IP54 4 2800K-6500K  CRI96 TLCI96 

2600W 1000 2800K-6500K CRI96TLCI96 4S DMX 512/LumenRadio CRMX/App G IP54  11FXSOS

LED    

02





1

4

1. 1 2. 2 3.  4. DC 5.  6. U 7.  8. G 9. 
8 7
03



12

3

1. 

2

2. 

3. DC

4. PRESET

5. LOCK

3

6. MENU

7. MODE

8. 

9. CRMX

5

10. 

11. 

12. DMX OUT

6

13. DMX IN

11 4 5 6 7 8 9 10

14. AC

15. 

9

12

14

13

15

04

MG2400Bi

MG2400Bi K1

×1

U×1

×1

×1

U×1

×1

×1

×1

×1

×1

×1

×1

×1

×1

×1

×1

×1

DC×1

×1 DMX×1 ×1

×1

DC×1

×1 DMX×1 ×1

SC18×1

SC19×1

05

06

MG2400Bi K2



×1

U×1

×1

UG2400BY01

GRK

×1

×1

×1

×1

×1

GF14 GO3

GO4

GO5

×1

DC×1

×1 DMX×1 ×1

 ×1

  
07

GP3

GP4

GP5

GRK2

08


1.U

GP19K

GP26K

GP36K

1.1

1.2 

SC18

SC19

FC05

GR45B

GR30B

09

1.3 U "" 

1.4   


10

2.U

4. /

2.1  

2.2U 

3./

3.1 

3.2 

11

4.1 


4.2 

5. 

5.1 

6. AC
123 

 

12

7. DMX 7.1DMX
CRMX TX DMX512

CRMX CRMX CRMX

7.2DMX DMX 
DMX512 DMX

DMX 

DMX 

13

8. 


CRMX

CRMX CRMX CRMX

DMX 

DMX 

14




           

AC100V-240V



MODE/

                  0%-100%
0.1            0 .1  
 2800K-6500K
100 100

85.2 % 2800 K

15

FX
MODEFX ////// ////SOS11


8 

1. 
                                           /MODE 


 : / 0-100 2800K-6500K 1-100 /

2. 
                                                      /   M O D E 


 : / 0-100 2800K-6500K /1-10 /2-20

3. 
                                      /   M O D E   

 : / 0-100 10-90 /1-100

16

4. 
                                    /   M O D E   

 / 0-100 2800K-6500K 1-100

5. 
                             /MODE 
6. 
                                              /MODE 
7. 
                                             /MODE  

 / 0-100 1-100
 / 0-100 1-100
 / 0-100 1-100

8. 
                                /MODE 

 / 0-100 1-100 01-100

17

9. 
                                                  /MODE  
10. 
                                /MODE 

 /  0-100 2800K-6500K 1-100 1-100
 /  0-100 2800K-6500K 1-100

11. S0S
S0S                                   /MODE   FX

 / : 0-100 2800K-6500K

18


  M E N U              D M X C R M X    A rt - N e t & sACN          

1
DHCP



 V0.13
MG2400Bi

1.DMX
DMX /DMX/RDM/DMX/    /                                                MENU

DMX RDM DMX 

01CCT 8 Bit 2

DMX DMX

CRMX CRMX

  DMX
RDM DMX
 

 1-512 01:CCT 8 Bit 02:FX 8 Bit 03:CCT 16 Bit 04:FX 16 Bit 05:ULTIMATE DMX 8 Bit 06:ULTIMATE DMX 16 Bit   
 2
   

  8CCT 8FX 16CCT 16FX 8 DMX 16 DMX RDM RDM DMXDMX DMX  DMXDMX 222 DMXDMX DMX DMX  

DMX/RDMDMX https://www.godox.com.cn 

19

20

2.CRMX
CRMXCRMX/ MENU  /





CRMX

 CRMX  


     5dBm 11dBm 16dBm 20dBm  

CRMX
 CRMX CRMX CRMX CRMX 5dBm 11dBm 16dBm 20dBm  

3.
         /                      MENU "Godox Light"App 
App                AppAppV3.0
21

4.
   DHCP/Art-Net 2.x/Art-Net 10.x/ MENU



DHCP

MAC:020000000000

 
IP

 DHCP Art-Net 2.x Art-Net 10.x  AAA.BBB.CCC.DDD



255.BBB.CCC.DDD



AAA.BBB.CCC.DDD

Godox KNOWLED App
 DHCP 2.B.C.D 10.B.C.D IP DHCPIDDHCP Art-Net 2.xID2.B.C.D Art-Net 10.xID10.B.C.D AAA0-255 BBB0-255 CCC0-255 DDD0-255 DHCP/Art-Net 2.x/Art-Net 10.x 255.BBB.CCC.DDD  AAA0-255 BBB0-255 CCC0-255 DDD0-255 DHCPDHCP Art-Net 2.x2.B.C.D Art-Net 10.x10.B.C.D AAA0-255 BBB0-255 CCC0-255 DDD0-255
22

5.Art-Net&sACN
Art-Net&sACN        A rt - N e t & s AC N        A rt- N e t & s AC N        /A rt- N e t /s ACN /                      M E N U     

sACN 101 12

 Art-Net&sACN

 /Art-Net/sACN/

Art-Net Net Art-Net Sub-Net Art-Net Port Art-Net Universe sACN Universe

0-127 0-15 0-15 0...32767 1...63999

 Art-Net&sACN Art-NetArt-Net sACNsACN  Art-Net Art-NetArt-Net Art-Net Art-Net sACN

6.
 / MENU


7          M E N U       10-100
 +MODE 50%
8.         S      /MENU 
9.   /MENU 



S 

23

24

10.    10-10 0     M E N U 
11.                /English    MEN U  

12.
                                MENU 


U 

Box:V0.13

Lamp:V0.03

13.   /  English  100 
14.            UID              MENU 
0   

LOCK          LO C K                       







MG2400Bi Box:V0.12 Lamp:V0.01

8 

25

26


PRESET 1-20                // PRESET
   

1.  1.1 https://www.godox.com.cn/firmware-continuous-lightU 1.2 U USB-A 1.3 MG2400Bi 1.4 
2.  2.1 https://www.godox.com.cnG3.bin 2.2 USB-CUSB 2.3 G3"".bin  

 LEDLED  -- LED 
27







2800K

3200K

4300K 

5600K

6500K

 lux fc lux fc lux fc lux fc lux fc

3m 8810 818 9700 901 11600 1080 12000 1120 11300 1050

5m 3540 329 3950 367 4740 440 4890 454 4650 432

7m 2120 197 2360 220 2840 264 2900 269 2730 254

9m 1480 137 1640 152 1920 179 1970 183 1870 174

10m 1250 116 1380 128 1650 153 1700 158 1600 149

  2800K

 lux fc

3200K

lux

fc

4300K

lux

(45°)

fc

5600K

lux

fc

6500K

lux

fc

3m 32200 2990 35900 3340 43200 4020 44600 4140 42100 3910

5m 11700 1090 13000 1200 15700 1460 16200 1500 15300 1420

7m 6240 580 6900 641 8340 775 8590 798 8110 753

9m 4000 372 4450 413 5370 499 5520 513 5260 489

10m 3380 314 3740 348 4490 417 4650 432 4400 408

100

28



       CRI TLCI / 
 USB-A U  

MG2400Bi 100V-240V~50/60Hz 30A(Max.) 2900W 2800-6500K 0-100 /S// 11 96 96 IP54 DMX 512RDM/LumenRadio CRMX/App/ Art-Net & sACN//RC11 100m /5V 1.5A 409mm×385 mm×356mm 280mm×420mm×210mm

U20kg

13kg



: CMIIT ID:23J44811A003,

29

Important Safety Instructions and Precautions
First of all, as the most basic principle: This product is a professional lighting set equipment and should be used by professional lighting engineers or under the guidance of professionals. Basic safety attentions must always be followed during use, as follows:
1. Before use, please read and understand these instructions and attentions.
2. Professional lighting is prohibited for children. When children are near, parents or accompanying persons must supervise closely to prevent children from personal injury due to collision with lamps or private use of lamps.
3. This lighting product is not ordinary lighting product and cannot be used for general lighting. Anyone who has suffered eye damage or has sensitive eyes should avoid using this product.
4. When the lamp is on, it must be used with care. Do not touch high-temperature parts, such as LED lamp beads, to avoid burns.
5. When the lamp is on, it is forbidden to look directly at the lamp beads under any circumstances. Strong light should be used under the guidance of professional lighting engineers. Avoid prolonged exposure to strong light under any circumstances. If eye discomfort, please turn off the lamp in time, suspend use, and see a doctor immediately.
6. If the lamp bead is damaged or deformed by heat, stop using this equipment, and contact the manufacturer, service agent or qualified maintenance personnel to replace the lamp bead in time to avoid accidents.
7. This product is only suitable for use in -20¥ to 45¥ operating environment and normal humidity environment.
8. Do not use damaged equipment or accessories, and wait for professional maintenance personnel to check and repair to confirm being normal before use.
9. During using, if the casing of this product is broken due to being dropped, squeezed or subjected to strong impact, please do not use it, so as to avoid electric shock injury due to contact with internal electronic components.
10. If an extension cord is required, please use an extension cord with a current rating greater than or equal to that of the equipment. If an extension cord is rated less than the equipment, overheating may result.
11. Some products have long power cords, please place the power cords properly and keep them in a safe place. Avoid contacting the power cord with overheating surfaces, avoid improper placement that could cause pulling damage, or trip on-site personnel. Please use the certified power cord from the original manufacturer. If the product is damaged by using a non-certified power cord, it will not be repaired by our factory.
12. Be sure to unplug equipment from the power outlet before cleaning and repairing. When not in use, do not pull the power cord to unplug the equipment. For normal power-off, please hold both ends of the plug of the equipment with your hands and pull the plug out of power outlet. This equipment needs to be connected to a grounded outlet.
13. Do not disassemble the product without permission. If the product fails, it must be checked and repaired by authorized maintenance personnel.
14. Before storing, make sure that the equipment has cooled down completely. For storage, unplug the power cord from the equipment. The equipment should be placed in the carrying case or in a ventilated dry place.
30

15. Do not place equipment near flammable and volatile solvents such as alcohol and gasoline. 16. Do not use accessories that are not recommended by our factory to avoid fire, electric shock
or personal injury. 17. When cleaning, do not wipe it with a damp cloth, please use a dry cloth or a soft cloth to wipe
the dirt of the equipment. 18. Please take off the protective cover before using. 19. This product complies with ROHSCEand FCC certification, please refer to the relevant
national standards for use and operation. 20. The safety instructions are formulated according to the strict testing of the factory, and the
design and specifications of the equipment are subject to change without prior notice. For latest product information, please check the GODOX website and view latest electronic instruction. 21. One-year warranty period, accessories such as consumable batteries, adapters, power cords, etc. are not covered by this warranty. 22. If it is found that the equipment is repaired without authorization, the one-year warranty period will be cancelled and relevant fees will be charged for maintenance. 23. Machine failures caused by non-standard operation are not covered by the warranty. keep these instructions!
31

Forword
Thank you for purchasing MG2400Bi is a brand new high power LED light, with the following powerful features and functions: input power of 2900W, support 100V-240V~50/60Hz power supply which allows you to use it anywhere in the world, ultra-high and thousand-bit adjustable brightness, separate design of light body and controller, IP54 rate, four dimming curves, wide CCT range from 2800K to 6500K, CRI96 & TLCI96, various wireless controlling methods, and etc. This new product is suitable for shooting scenes in large-scale photography studios, film and television studios, broadcast studios, outdoor exteriors and large field scenes.
Main Features
2600W strong output power in full CCT range. Thousand-bit adjustable brightness from 0 to 100. Wide CCT range adjustable from 2800K to 6500K. Super high CRI: CRI96TLCI96 Four dimming curves: linear, S-curve, exponential, logarithmic. · Various wireless controlling methods: support DMX 512/LumenRadio CRMX/Bluetooth App control. With the brand new Godox G-Mount, communication contacts and intelligent accessory recognition, the safety index for the use of high-power lighting fixture is significantly improved. IP54 rate keeps the light head and controller from dust and water. Adopt efficient heat dissipation system design with large fan to meet the cooling needs of large LED light. 11 FX modes: flash, lightning, cloudy, broken bulb, TV, candle, fire, firework, explosion, welding, SOS.
Warning
Do not look directly at the LED light or illuminate at others' eyes. Do not plug or unplug the power cable or connecting cable when the power is turned on, otherwise personal injuries may occur. Do not cover the heat dissipation vent in working status. Keep out of reach of children. Please make sure to follow the instruction manual and correctly use this professional lighting device.
Don't stare at a bright light source
32

Name of Parts

Light Body

1

4

1. Handle 1

2. Handle 2

3. Direction Adjustment H andle

4. DC Input Port

5. Lanyard Attachment

6. Yoke

7. Mount Locking Pusher

8. Godox G-Mount

9. Quick Install Device

8

7

33

Controller

12

3

2

1. Antenna Port

2. Remove Controller Port

3. DC Output Port

4. PRESET Button

3

5. LOCK Button

6. MENU Button

7. MODE Button

8. Adjust Dial

5

9. Wireless CRMX Indicator

10. Power Switch

11. Display

6

12. DMX OUT Port

13. DMX IN Port

11 4 5 6 7 8 9 10

14. AC Input Port

15. Ethernet Port

9

12

14

13

15

34

What's Inside MG2400Bi

What's Inside MG2400Bi K1

Light Body × 1

Yoke × 1

Controller × 1

Light Body × 1

Yoke × 1

Controller × 1

Antenna × 1 Reflector × 1

Pipe Clamp × 1

Light Protection Cover × 1

Safety Wire × 1

Antenna × 1 Reflector × 1

Pipe Clamp × 1

Light Protection Cover × 1

Safety Wire × 1

Main Cable × 1

DC Cable × 1

Tying Rope × 1 DMX Practical Instruction

Table × 1

Manual × 1

Main Cable × 1

DC Cable × 1

Tying Rope × 1 DMX Practical Instruction

Table × 1

Manual × 1

Light Body Soft Case SC18 × 1

Accessory Soft Case SC19 × 1

35

3 6

What's Inside MG2400Bi K2

Optional Accessories

Light Body × 1

Yoke × 1

Controller × 1

Yoke G2400BY01

Reflector Kit GRK

Antenna × 1 Reflector × 1

Pipe Clamp × 1

Light Protection Cover × 1

Safety Wire × 1

Fresnel Lens GF14

Octa GO3

Octa GO4

Octa GO5

Main Cable × 1

DC Cable × 1

Tying Rope × 1 DMX Practical Instruction

Table × 1

Manual × 1

Flight Case × 1

Note: Due to continuous updates and upgrades of the products, there may be differences between the actual products and the pictures. Therefore, the pictures are for reference only, products to prevail in kind.
37

Parabolic Softbox GP3

Parabolic Softbox GP4

Parabolic Softbox GP5

Reflector Kit GRK2

38

Installation and Disassembly
1. Installing the Yoke

Projection GP19K

Projection GP26K

Projection GP36K

1.1 Place the light on a flat surface with the heat dissipation side upward.

1.2 Press down the quick install device button and remove the wrench.

Soft Case SC18

Soft Case SC19

Flight Case FC05

Barndoor GR45B

Barndoor GR30B

39

1.3 Align both ends of the yoke with the quick install device, lock the wrenches on both sides, and then the "click" indicates successful installation.

1.4 Install the light on the roller stand and lock the fixing knob on the roller stand.
Note: The roller stand is sold separately. Please be careful when installing the light as it is quite heavy.

40

2. Disassembling the Yoke

4. Installing/Disassembling the Reflector

2.1 Hold the handle of the light and remove it from the roller stand then place it on a flat surface.

2.2 Press and hold the quick install device button and release the wrench to remove the yoke.

3. Installing/Disassembling the Light Protection Cover

3.1 Align the light protection cover with the mount and rotate clockwise to install.

3.2 Press and hold the mount locking pusher and rotate counterclockwise to remove the light protection cover.

41

4.1 Align the reflector with the mount, insert and then rotate clockwise to install.
Note: Make sure to align the reflector with the mount of the lamp head.

4.2 Press and hold the mount locking pusher and rotate counterclockwise to remove the light protection cover.

5. Installing the Controller on the Light Stand

5.1 Loosen the handle of pipe clamp and insert the light stand pole, rotate the handle clockwise to lock the mounting device, then align the quick install device with the slot of mounting device and insert it.

6. AC Power Cord Connection Instructions
Wire 1 (yellow) is the ground wire, wire 2 (black) is the neutral wire, while wire 3 (red) is the live wire. Please ensure proper connection by matching the corresponding wires to the appropriate terminals on the plug before use.

 

42

7. Connect to DMX 512 Controller 7.1 Wireless DMX Connection
CRMX TX DMX512

CRMX CRMX

7.2 Wired DMX Connection
DMX Connection

DMX Connection

DMX 512 Note: The DMX cable is sold separately.

CRMX
DMX Connection

8. Connect to Ethernet Connection 1

CRMX

CRMX

Ethernet
Connection 2 DMX Connection
Ethernet

CRMX CRMX

DMX Connection

DMX Connection

43

44

Power Supply

AC100V-240V
Note: Do not plug or unplug the power cord or connecting cable when the power is turned on, otherwise injuries may occur.
Power On/Off
Connect the device to the power source and briefly press the power switch button on the controller to turn it on or off.

CCT Mode
Briefly press the MODE button to switch to CCT mode. Briefly press the adjust dial to switch between the brightness setting interface and color temperature setting interface.

In the brightness setting interface, turn the adjust dial to adjust the brightness ratio from 0% to 100%. Turning the adjust dial clockwise once will increase the value by 0.1 unit, while turning it counterclockwise once will decrease the value by 0.1 unit. Quick adjustment is also available during rapid rotation.

85.2 % 2800 K

45

In the color temperature setting interface, turn the adjust dial to adjust the color temperature from 2800K to 6500K.
Turning the adjust dial clockwise once will increase the value by 100 units, while turning it counterclockwise once will decrease the value by 100 units.

FX Mode
Briefly press the MODE button to switch to FX mode. Turn the adjust dial to switch among the following 11 effects: flash, lightning, cloudy, broken bulb, TV, candle, fire, firework, explosion, welding, SOS.
Select the desired lighting effect and briefly press he adjust dial to enter the effect setting interface.

8 Firework

1. Flash Effect In the flash effect setting interface, turn the adjust dial to select options among switch, dim, CCT, auto, manual, speed, mode, etc. Briefly press the adjust dial to select the desired option then turn the dial to adjust the options (except for the auto and manual options). Finally, continuously press the adjust dial/briefly press the MODE button to return to the previous menu.
2. Lightning Effect In the lightning effect setting interface, turn the adjust dial to select options among switch, dim, CCT, auto, manual, times, frequency, etc. Briefly press the adjust dial to select the desired option then turn the dial to adjust the options (except for the auto and manual options). Finally, continuously press the adjust dial/briefly press the MODE button to return to the previous menu.

Switch: Turn on/off the effect Dim: 0-100 CCT: 2800K-6500K Speed: 1-100 Mode: Camera Flash/Flash Bulb Note: If manual is selected, the flash effect can be triggered once by briefly pressing the adjust dial.
Switch: Turn on/off the effect Dim: 0-100 CCT: 2800K-6500K Times: Random/1-10 Frequency: Random /2-20 Note: If manual is selected, the lightning effect can be triggered once by briefly pressing the adjust dial.

46

3. Cloudy Effect In the cloudy effect setting interface, turn the adjust dial to select options among switch, dim, ratio, speed, etc. Briefly press the adjust dial to select the desired option then turn the dial to adjust the options. Finally, continuously press the adjust dial/briefly press the MODE button to return to the previous menu.
4. Broken Bulb Effect In the broken bulb effect setting interface, turn the adjust dial to select options among switch, dim, CCT, speed, etc. Briefly press the adjust dial to select the desired option then turn the dial to adjust the options. Finally, continuously press the adjust dial/briefly press the MODE button to return to the previous menu.
5. TV Effect In the TV effect setting interface, turn the adjust dial to select options among switch, dim, speed, etc. Briefly press the adjust dial to select the desired option then turn the dial to adjust the options. Finally, continuously press the adjust dial/briefly press the MODE button to return to the previous menu.
6. Candle Effect In the candle effect setting interface, turn the adjust dial to select options among switch, dim, speed, etc. Briefly press the dial to select the desired option then turn the adjust dial to adjust the options. Finally, continuously press the adjust dial/briefly press the MODE button to return to the previous menu.

Switch: Turn on/off the effect Dim: 0-100 Ratio10-90 Speed: Random/1-100
Switch: Turn on/off the effect Dim: 0-100 CCT2800K-6500K Speed: 1-100
Switch: Turn on/off the effect Dim: 0-100 Speed: 1-100
Switch: Turn on/off the effect Dim: 0-100 Speed: 1-100

47

7. Fire Effect In the fire effect setting interface, turn the adjust dial to select options among switch, dim, speed, etc. Briefly press the adjust dial to select the desired option then turn the dial to adjust the options. Finally, continuously press the adjust dial/briefly press the MODE button to return to the previous menu.
8. Firework Effect In the firework effect setting interface, turn the adjust dial to select options among switch, dim, speed, embers, etc. Briefly press the adjust dial to select the desired option then turn the dial to adjust the options. Finally, continuously press the adjust dial/briefly press the MODE button to return to the previous menu.
9. Explosion Effect In the explosion effect setting interface, turn the adjust dial to select options among switch, dim, CCT, auto, manual, speed, embers, etc. Briefly press the adjust dial to select the desired option then turn the dial to adjust the options (except for the auto and manual options). Finally, continuously press the adjust dial/briefly press the MODE button to return to the previous menu.
10. Welding Effect In the welding effect setting interface, turn the adjust dial to select options among switch, dim, CCT, speed, etc. Briefly press the adjust dial to select the desired option then turn the dial to adjust the options. Finally, continuously press the adjust dial/briefly press the MODE button to return to the previous menu.

Switch: Turn on/off the effect Dim: 0-100 Speed: 1-100
Switch: Turn on/off the effect Dim: 0-100 Speed: 1-100 Embers: 01-100
Switch: Turn on/off the effect Dim: 0-100 CCT: 2800K-6500K Speed: 1-100 Embers: 1-100 Note: If manual is selected, the explosion effect can be triggered once by briefly pressing the adjust dial.
Switch: Turn on/off the effect Dim: 0-100 CCT: 2800K-6500K Speed: 1-100

48

11. SOS Effect
In the SOS effect setting interface, turn the adjust dial to select options among switch, dim, CCT, etc. Briefly press the adjust dial to select the desired option then turn the dial to adjust the options. Finally, continuously press the adjust dial/briefly press the MODE button to return to the previous menu.
Menu Settings
Briefly press the MENU button to enter menu settings, turn the adjust dial to select among the following options: DMX, CRMX, Bluetooth, Network settings, Art-Net & sACN, optics recognition, power limit dimming curves fan, display, language, version & upgrade, factory reset, fixture info.

Switch: Turn on/off the effect Dim: 0-100 CCT: 2800K-6500K Note: The default dimming curve in FX mode is linear.
1
DHCP

ON
English V0.13
MG2400Bi
1. DMX Briefly press the adjust dial to enter DMX setting interface. Turn the adjust dial to select options among address, DMX mode, RDM state, DMX lost, termination, extend DMX channels. Briefly press the adjust dial to select the desired option then turn it to adjust settings. Finally, briefly press the adjust dial to exit the current setting, briefly press the MENU button to return to the previous menu.
49

DMX Mode RDM State DMX Lost

01:CCT 8 Bit On
Black Out After 2 Min

Interface when connected to DMX DMX
ULTIMATE DMX 16BIT

Interface when connected to CRMX CRMX
ULTIMATE DMX 16BIT

Off

Off

Level 1 Option Level 2 Option

Address

1-512

DMX Mode

01:CCT 8 bit

02:FX 8 bit

03:CCT 16 bit

04:FX 16 bit

05:ULTIMATE DMX 8 bit

06:ULTIMATE DMX 16 bit

RDM State

On

Off

DMX Lost

Hold Last Command

Black Out Black Out After 2 Min

Termination On

Off

Extend DMX On

Channels

Off

Description Initial address CCT Mode in 8 bit FX Mode in 8 bit CCT Mode in 16 bit FX Mode in 16 bit DMX Mode in 8 bit DMX Mode in 16 bit Turn on RDM Turn off RDM After the DMX control signal is lost, continue to use the last received DMX control signal until power down or a valid DMX control signal is received again. The light is off immediately. After the DMX control signal is lost, continue to use the last received DMX control signal for 2 minutes then black out. Note: If a valid DMX control signal is received within 2 minutes, then use the new DMX control signal. Turn on DMX terminal Turn off DMX terminal Turn on extend DMX channels Turn off extend DMX channels
50

Note: Please refer to the DMX Practical Table to control the device by DMX/RDM. The electronic version can be downloaded from the official website https://www.godox.com.
2. CRMX
Briefly press the adjust dial to enter CRMX setting interface. Turn the adjust dial to select options between switch and mode. Briefly press the adjust dial to select the desired option then turn it to adjust settings. Finally, briefly press the adjust dial to exit the current setting, briefly press the MENU button to return to the previous menu. Note: Before selecting the transmit mode/receive mode, perform a reset first.

CRMX MODE

Reset

Reset

Transmitter mode in CRMX

MODE Status Reset
Receiver mode in CRMX

Level 1 Option CRMX Mode Output Power
Status

Level 2 Option On Off Transmitter Receiver 5dBm 11dBm 16dBm 20dBm Link Linking

Description Turn on CRMX Turn off CRMX Transmitter mode Receiver mode Output power value = 5dBm (only adjustable in transmitter mode) Output power value = 11dBm (only adjustable in transmitter mode) Output power value = 16dBm (only adjustable in transmitter mode) Output power value = 20dBm (only adjustable in transmitter mode) To enter linked status (only adjustable in transmitter mode) Linking (only adjustable in transmitter mode)

3. Bluetooth
Briefly press the adjust dial to enter Bluetooth setting interface. Turn the adjust dial to select options between switch and reset. Briefly press the adjust dial to select the desired option then turn the dial to adjust settings. Finally, briefly press the MENU button to return to the previous menu.
Scan the QR code to download the "Godox Light" smartphone app version 3.0 or above (can be used in Android and iOS).
Note: The app can be used directly on the firstly installed device (smartphone or iPad). When change to other mobile device (smartphone or iPad), the light shall be reset before the normal connection of the app.

4. Network Settings
Briefly press the adjust dial to enter network settings interface. Turn and briefly press the adjust dial to select network mode, then turn the dial to select among DHCP, Art-Net 2.x, Art-Net 10.x and manual. Finally, briefly press the MENU button to return to the previous menu.

DHCP 020000000000

Godox KNOWLED App

51

52

Level 1 Option Network Mode IP
Subnet Mask
Default Gateway

Level 2 Option DHCP Art-Net 2.x Art-Net 10.x Manual AAA.BBB.CCC.DDD
255.BBB.CCC.DDD
AAA.BBB.CCC.DDD

Description DHCP mode To use 2.B.C.D network To use 10.B.C.D network Set the network IP, subnet mask, and default gateway manually. The ID address is assigned by DHCP in DHCP mode. The ID address is 2.B.C.D in Art-Net 2.x mode. The ID address is 10.B.C.D in Art-Net 10.x mode. In manual mode: AAA0-255 BBB0-255 CCC0-255 DDD0-255 The subnet mask is 255.BBB.CCC.DDD and can not be adjusted by menu settings in DHCP/Art-Net 2.x/Art-Net 10.x mode. In manual mode: AAA0-255 BBB0-255 CCC0-255 DDD0-255 The default gateway is assigned by DHCP in DHCP mode. The default gateway is 2.B.C.D in Art-Net 2.x mode. The default gateway is 10.B.C.D in Art-Net 10.x mode. In manual mode: AAA0-255 BBB0-255 CCC0-255 DDD0-255

5. Art-Net & sACN
Briefly press the adjust dial to enter Art-Net & sACN setting interface. Turn and briefly press the adjust dial to select options among auto, Art-Net, sACN and off, then other level 2 options are available to adjust. Finally, briefly press the MENU button to return to the previous menu.

53

Level 1 Option Art-Net&sACN
Art-Net Net Art-Net Sub-Net Art-Net Port Art-Net Universe sACN Universe

Level 2 Option Auto/Art-Net/sACN/Off
0-127 0-15 0-15 0...32767 1...63999

Description AutoArt-Net & sACN two protocols are accepted. Art-NetOnly Art-Net protocol. sACNOnly sACN protocol. OffNo network protocols are accepted. Art-Net network Choose Art-Net subnet in Art-Net network. Art-Net port Art-Net universe sACN universe

6. Optics Recognition
Briefly press the adjust dial to enter optics recognition setting interface. Turn and briefly press the adjust dial to turn the function on or off. Finally, briefly press the MENU button to return to the previous menu.
Note: The light will not be lightened if the optics is not correctly installed even optics recognition function is turned on.

7. Power Limit
Briefly press the adjust dial to enter power limit setting interface. Rotate and briefly press the adjust dial to turn the function on or off. Finally, briefly press the MENU button to return to the previous menu.
Max. limit:10%-100%
Note: If the power supply environment is unable to meet the requirements for powering on, you can activate this function while the device is in the powered-off state. Simultaneously press the Preset button and MODE button, and the device will automatically enter the Power Limit mode upon startup (default power limitation is set to 50%).

54

8. Dimming Curves
Briefly press the adjust dial to enter dimming curves setting interface. Rotate and briefly press the adjust dial to choose among linear, S-curve, exponential and logarithmic. Finally, briefly press the adjust dial/MENU button to return to the previous menu.

9. Fan
Briefly press the adjust dial to enter fan setting interface. Rotate and briefly press the adjust dial to choose among mute, auto, medium, and high. Finally, briefly press the adjust dial/MENU button to return to the previous menu.

FAN OFF

Auto

Medium

High

10. Display
Briefly press the adjust dial to enter display setting interface. Rotate and briefly press the adjust dial to adjust display brightness from 10 to 100%. Finally, briefly press the MENU button to return to the previous menu.

11. Language
Briefly press the adjust dial to enter language setting interface. Rotate and briefly press the adjust dial to select between Simplified Chinese and English. Finally, briefly press the MENU button to return to the previous menu.

Language

12. Version & Upgrade
Briefly press the adjust dial to enter version & upgrade setting interface to check the firmware version of lamp head & controller and upgrade instruction. Then, short press the MENU button to return to the previous menu.
13. Factory Reset
To access the factory reset interface, briefly press the adjust dial. Rotate the adjust dial to select "Yes" or "No," then briefly press the adjust dial to complete the setting. Once you have confirmed the factory reset, the light fixture will restart, and the interface will automatically display options for Chinese and English. Rotate the dial to select an option and then press the dial to confirm the setting. At this point, the brightness value of the light will automatically be set to 100% and the interface will return to CCT mode interface.

Version&Upgrade
Insert The U Disk With New Firmware After Power Off, Then Reboot To Upgrade The Device.

Box:V0.13

Lamp:V0.03

55

56

14. Fixture Info
Briefly press the adjust dial to enter fixture info setting interface to check model, UID NO., firmware version of lamp head and controller, light head temp., lamp maintenance time reminder, certification etc. Then, briefly press the MENU button to return to the previous menu.

When the lamp head displays a remaining maintenance time of 0 hours, it is recommended for the customer to clean the glass or other parts of the lamp head. We suggest using a dry or soft cloth to wipe away any dirt or debris on the equipment. Once the maintenance is complete, if you choose to reset, the lamp head maintenance time will start counting again.

MG2400Bi Box:V0.12 Lamp:V0.01 1000

Lock Setting

Briefly press the LOCK button, the panel is locked

when <

> is displayed on the panel, briefly

press again to unlock.

Note: The locking function only works on the controller panel, other operations are still available.

Preset Setting
Briefly press the PRESET button to enter preset effects interface. Rotate and briefly press the adjust dial to choose and enter preset effects 1-20, then briefly press to select save or cancel. Then, briefly press the adjust dial to return to the previous menu and briefly press the PRESET button to exit.
Apply: Apply this set of preset lighting effects. Save: Save the current lighting effect of the light fixture. Cancel: Return to the previous interface.
Note: If light effect data has been previously saved, there will be an additional option.
57

8 Firework
1 Apply
2 Save 3 Cancel

Software Upgrade
1.Firmware version of controller 1.1 Download the new firmware to the U disk from official website (https://www.godox.com.cn/firmware-continuous-light). 1.2 Turn off the device. Insert the U disk with new firmware into the USB Type-A port. 1.3 Turn on the device, and MG2400Bi controller will automatically enter the upgrading interface. 1.4 It will return to main interface after completion.
2.Firmware version of light head 2.1 Download the firmware upgrade software G3 and the corresponding product firmware (.bin) from the official website (https://www.godox.com). 2.2 Connect the computer interface to the USB-C port of the light head via USB cable. 2.3 Open the G3 application, click `Open File' to open the .bin file, click upgrade, and wait for the upgrade to complete.
Note: There is no need to connect to the controller when upgrading the light head.
Version&Upgrade
Insert The U Disk With New Firmware After Power Off, Then Reboot To Upgrade The Device. Box:0.13 Lamp:V0.03
Maintenance
This product, except consumables, is supported with a one-year warranty. Unauthorized service will void the warranty. Maintenance of the light must be performed by our authorized maintenance department which can provide original accessories. If the product had failures or become wet, do not use it until it is repaired by professionals. Shut down the device immediately should abnormal operation be detected.
58

Photometric Data

CCT 2800K

Testing Condition

3200K 4300K Bare Light

5600K

6500K

Illuminance Unit lux fc
lux fc
lux fc
lux fc
lux fc

3m 8810 818 9700 901 11600 1080 12000 1120 11300 1050

5m 3540 329 3950 367 4740 440 4890 454 4650 432

7m 2120 197 2360 220 2840 264 2900 269 2730 254

9m 1480 137 1640 152 1920 179 1970 183 1870 174

10m 1250 116 1380 128 1650 153 1700 158 1600 149

CCT

Testing Condition

2800K

3200K

4300K With Reflector (45°)
5600K

6500K

Illuminance Unit lux fc
lux fc
lux fc
lux fc
lux fc

3m 32200 2990 35900 3340 43200 4020 44600 4140 42100 3910

5m 11700 1090 13000 1200 15700 1460 16200 1500 15300 1420

7m 6240 580 6900 641 8340 775 8590 798 8110 753

9m 4000 372 4450 413 5370 499 5520 513 5260 489

10m 3380 314 3740 348 4490 417 4650 432 4400 408

The above data is not absolute values but rather average values. All tests were conducted with the light at 100% brightness.

Technical Data
Model Power Supply Max. Power CCT Brightness Range Dimming Curves FX Modes CRI TLCI Waterproof Grade of Light Body/Controller Controlling Methods

MG2400Bi 100V-240V~50/60Hz 30A(Max.) 2900W 2800-6500K 0-100 linear, S-curve, exponential, logarithmic 11 Average96 Average96 IP54
DMX 512 Control, support RDM protocol/LumenRadioCRMX/Bluetooth App Control /Ethernet (support Art-Net & sACN protocol)/Remove Controller/Light Body ControlRemove Controller RC11 is sold separately

Bluetooth Controlling Distance USB Type-A Port DimensionYoke and reflector are not included in the light body Netweight

Max. 100m Firmware Upgrade/5V 1.5A Power Supply Light Body16.10" ×15.16"×14.02" Controller11.02`*16.54"*8.27"
Light BodyYoke and reflector not included20kg Controller13kg

Specifications and data may subject to changes without notice.

59

60

FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.
Warning
Operating frequency: 2402MHz ­ 2480MHzcBT Maximum EIRP Power: 5dBm
Declaration of Conformity
GODOX Photo Equipment Co.,Ltd. hereby declares that this equipment are in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. In accordance with Article 10(2) and Article 10(10), this product is allowed to be used in all EU member states.For more information of DoC, Please click this web link: https://www.godox.com/eu-declaration-of-conformity/ The device complies with RF specifications when the device used at 0mm from your body.




 

  

 

 





 


         (    )             (    )
  
    


:                               






 

() 12





3





12









   


 0755-29609320-8062

Warranty
Dear customers, as this warranty card is an important certificate to apply for our maintenance service, please fill in the following form in coordination with the seller and safe-keep it. Thank you!

Product Information Customer Information
Seller Information
Note

Model Name Address Name Contact Number
Address Date of Sale

Product Code Number Contact Number
Note: This form shall be sealed by the seller.

Applicable Products
The document applies to the products listed on the Product Maintenance lnformation (see below for further information). Other products or accessories (e.g. promotional items,giveaways and additional accessories attached,etc.) are not included in this warranty scope.
Warranty Period The warranty period of products and accessories isimplemented according to the relevant Product Maintenance Information. The warranty period is calculated from the day(purchase date) when the product is bought for the first time,And the purchase date is considered as the date registered onthe warranty card when buying the product.
How to Get the Maintenance Service If maintenance service is needed, you can directly contact the product distributor or authorized service institutions. You can also contact the Godox after-sale service call and we will offer you service. When applying for maintenance service, you should provide valid warranty card. If you cannot provide valid warranty card, we may offer you maintenance service once confirmed that the product or accessory is involved in the maintenance scope, but that shall not be considered as our obligation.
Inapplicable Cases
The guarantee and service offered by this document are not applicable in the following cases:  The product or accessory has expired its warranty period;  Breakage or damage caused by inappropriate usage, maintenance or preservation, such as improper packing, improper usage, improper plugging in/out external equipment, falling off or squeezing by external force, contacting or exposing to the improper temperature, solvent, acid, base, flooding and damp environments, etc;  Breakage or damage caused by non-authorized institution or staff in the process of installation, maintenance, alternation, addition and detachment;  The original identifying information of product or accessory is modified, alternated, or removed;  No valid warranty card;  Breakage or damage caused by using

illegally authorized, nonstandard or non-public released software;  Breakage or damage caused by force majeure or accident;  Breakage or damage that could not be attributed to the product itself. Once met these situations above, you should seek solutions from the related responsible parties and Godox assumes no responsibility. The damage caused by parts, accessories and software that beyond the warranty period or scope is not included in our maintenance scope. The normal discoloration, abrasion and consumption are not the breakage within the maintenance scope.

Maintenance and Service Support Information

The warranty period and service types of products are implemented according to the following Product Maintenance Information:

Product Type

Name Circuit Board

Maintenance Period(month)
12

Parts

Battery

3

Electrical parts e.g.battery

12

charger, etc.

Other Items

Power cord, lamp cover,lockingdevice, package, etc.

No

Warranty Service Type Customer sends the
product to designated site Customer sends the
product to designated site Customer sends the
product to designated site
Without warranty

Godox After-sale Service Call +86-755-29609320(8062)



References

Adobe Illustrator 24.0 (Windows) iLovePDF