User Guide for Yotto models including: v3, v3 Version Of The Combusto, v3, Version Of The Combusto, The Combusto, Combusto
Combusto - Overlander's All in One 5kw Diesel Heater – Yotto Overland Read through the
Combusto Diesel Guide Yotto Overland *This manual is for the v3 version of the Combusto. Instruction Manual Diesel Heater Controller Fuel Pump Prime Mode (Before First Use) To prime the pump without running the heater: 1. Unplug the control panel. 2. While plugging the control panel back in, press and hold the Fuel Level Reset key. 3. After approximately 15 seconds, the screen will display the tank and pump icon. 4. Release the key. The pump will begin operating. 5. The system will automatically stop after 180 seconds. Warning: Do not allow too much fuel to be pumped into the heater during this process. Basic Operations · Turn Heater ON/OFF: Press and hold the ON/OFF key to turn the heater on or off. · Change Run Mode: Press the adjust knob to toggle between Manual Mode and Automatic Mode. · Adjust Output Power or Temperature: Combusto Diesel Guide Yotto Overland In Manual Mode, turn the knob to adjust power output (displayed at the bottom of the screen). In Automatic Mode, turn the knob to set the target temperature (flashing on screen). Remote Control Authorization While the heater is ON: 1. Press and hold the SET and ON/OFF keys for more than 3 seconds until the display shows "En00". 2. Turn the knob to "En08". 3. Press and hold the adjust knob for more than 3 seconds until "P1" appears. Pair the remote with the corresponding buttons: · P1 "Up" button · P2 "Down" button · P3 "Mode" button · P4 "ON/OFF" button Bluetooth Password Setup 1. Open the AirHeaterBLE app and begin setup. 2. Turn on the heater. 3. Press and hold SET and ON/OFF for more than 3 seconds until "En00" appears. 4. Turn the knob to "bLE" to display the 4-digit password (default: 1234). 5. Press and hold the adjust knob for more than 3 seconds until the password blinks. 6. When "SUC" is displayed, the password has been successfully set. Fuel Settings Combusto Diesel Guide Yotto Overland · Reset Fuel Level: While ON, press and hold the Fuel Level Reset key for more than 7 seconds. · Set Fuel Tank Capacity: 1. While ON, hold SET for more than 4 seconds until "F0" appears. 2. Turn the knob to "F6" and press to enter setup. 3. Adjust tank size between 550L in 5L steps. "--" disables this function. 4. Press the knob again to save. (Default: 10L) · Set Fuel Pump Flow Rate: 1. While ON, hold SET for more than 4 seconds until "F0" appears. 2. Turn the knob to "F7", press to enter. 3. Adjust flow rate (16, 22, 28, or 32). 4. Press the knob again to save and exit. Time and Timer Settings 1. While ON, hold SET for more than 4 seconds until "F0" is shown. 2. Turn the knob to cycle between the following: F0 Local Time F1 Appointment Time F2 Running Time F3 Timer ON/OFF To configure a setting: · Select the option and press the knob to enter edit mode. · Adjust the time (0.5 to 10 hours, in 0.5-hour steps). · "tOF" = Timer OFF "tON" = Timer ON · Press the ON/OFF key to exit edit mode. Combusto Diesel Guide Yotto Overland Intelligent Start-Stop Mode 1. While ON, hold SET for more than 4 seconds until "F0" is displayed. 2. Turn the knob to "F9", press the knob to enter. 3. Toggle between: AUon Enable Intelligent Start-Stop Mode AUoF Disable Intelligent Start-Stop Mode 4. Press the knob again to save and exit. Language Setting 1. While ON, hold SET for more than 4 seconds until "F0" is displayed. 2. Turn the knob to "F4", press the knob. 3. Select your language: C Chinese E English R Russian -- Disable 4. Press the knob to save. Combusto Diesel Guide Yotto Overland Error Codes · E01 Startup Failure: Check the fuel line from the nozzle to the engine for blockages. May occur if the heater was not primed properly. · E02 Lack of Fuel: Check the fuel tank and refill if empty. · E03 Supply Voltage Error: Check the power source. Use a 110V adapter if necessary. · E04 Outlet Sensor Fault: Check sensor connection. Replace if necessary. · E05 Inlet Sensor Fault: Check sensor connection. Replace if necessary. · E06 Pulse Pump Fault: Check pump connection. Replace if necessary. · E07 Fan Fault: Check fan connection. Replace if necessary. · E08 Ignition Unit Fault: Check ignition connection. Replace if necessary. · E09 Overheating: Check for blockages at the air inlet and outlet.macOS Version 15.2 (Build 24C101) Quartz PDFContext Pages