Instrument Set-up and Introduction

⚠️ The safety instructions and the user manual should be read through carefully before the product is used for the first time.

The person responsible for the product must ensure that all users understand these directions and adhere to them.

Device Operation Basics

The STABILA LD 250 BT features a display showing measurements, typically in meters (m). Key controls include:

1. Power/Measure Button: Initiates measurement or turns the device on/off.

2. Function Button (FUNC): Used to cycle through functions like Area, Volume, and Unit selection.

3. Bluetooth Button: Activates or deactivates the Bluetooth connection.

4. Clear/Off Button: Clears the current measurement or turns the device off.

Basic Operations and Setup

Battery Installation: The device requires 2 x AAA batteries. Ensure correct polarity when inserting.

Unit Selection: Press and hold the FUNC button for 2 seconds to change the measurement unit (e.g., meters, feet, inches). The display shows formats like 0.000 m, 0'00"1/16, or 0 in 1/16.

Beep ON/OFF: Press FUNC and the Bluetooth button simultaneously for 2 seconds to toggle audible beeps.

Power Off: Press and hold the Clear/Off button (circular arrow icon) for 2 seconds to turn the device off.

Bluetooth ON/OFF: Press and hold the Bluetooth button for 2 seconds to enable or disable Bluetooth connectivity.

Measurement Scenarios: The device can measure distances from walls or corners. Diagrams illustrate measurements taken from two points in a corner (labeled 1 and 2) and three points along a wall (labeled 1, 2, and 3).

Example Measurements: A distance of 8.532 m is shown being measured from a wall. Another diagram suggests a potential area measurement of 18.462 m².

Connectivity: The device can connect wirelessly via Bluetooth to devices like laptops and smartphones.

Technical Data

ParameterValue
Accuracy with favourable conditions *± 2.0 mm / ± 0.08 in ***
Accuracy with unfavourable conditions **± 3.0 mm / ± 0.12 in ***
Range with favourable conditions *0.2-50 m / 0.6-164 ft
Range with unfavourable conditions **0.2-40 m/0.6-131 ft
Smallest unit displayed1 mm / 0.04 in
Laser class2
Laser type635 nm, < 1 mW
Ø laser point at distances6/30 mm (at 6/30 m)
Protection classIP54
Autom. laser switch offafter 90 s
Autom. power switch-offafter 180 s
Battery durability (2 x AAA)up to 5000 measurements
Dimension (H x D x W)115 x 53 x 25 mm / 4.5 x 2.1 x 1 in
Weight (with batteries)95 g / 3.4 oz
Temperature range: Storage-25 to 70 °C / -13 to 158 °F
Temperature range: Operation0 to 40 °C / 32 to 104 °F

* Favourable conditions: white and diffuse reflecting target (e.g., white painted wall), low background illumination, and moderate temperatures.

** Unfavourable conditions: targets with lower or higher reflectivity, high background illumination, or temperatures at the upper or lower end of the specified range.

*** Tolerances apply from 0.2 m to 5 m with a confidence level of 95%. Tolerance may deteriorate by 0.1 mm/m for distances above 5 m in favourable conditions, and by 0.15 mm/m in unfavourable conditions.

Message Codes and Laser Classification

If the 'Error' message persists after switching the device on repeatedly, contact the dealer. If 'InFo' appears with a number, press the Clear button and consult the following:

Message Codes

No.CauseCorrection
204Calculation errorPerform measurement again.
240Data transfer errorRepeat procedure.
252Temperature too highLet device cool down.
253Temperature too lowWarm device up.
254Battery voltage too low for measurementsChange batteries.
255Received signal too weak, measuring time too longChange target surface (e.g., white paper).
256Received signal too highChange target surface (e.g., white paper).
257Too much background lightShadow target area.
258Measurement outside of measuring rangeCorrect range.
260Laser beam interruptedRepeat measurement.

Laser Classification

ParameterValue
Wavelength635 nm
Maximum radiant output power used for classification0.95 mW
Pulse repetition frequency320 MHz
Pulse duration>400 ps
Beam divergence0.16 mrad x 0.6 mrad

Warranty and Responsibilities

Warranty

STABILA provides a two-year warranty for the product. Further information can be found on the Internet at: www.stabila.de.

Areas of Responsibility

Responsibilities of the manufacturer of the original equipment:

STABILA Messgeräte
Gustav Ullrich GmbH
P.O. Box 13 40/D-76851 Annweiler
Landauer Str. 45/D-76855 Annweiler

USA/Canada:
STABILA Inc.
332 Industrial Drive
South Elgin, IL 60177
1.800.869.7460

The company above is responsible for supplying the product, including the User Manual in a completely safe condition. The company above is not responsible for third party accessories.

Responsibilities of the person in charge of the instrument:
  • To understand the safety instructions on the product and the instructions in the User Manual.
  • To be familiar with local safety regulations relating to accident prevention.
  • Always prevent access to the product by unauthorised personnel.

Use of the product with Bluetooth® and Precautions

⚠️WARNING: Electromagnetic radiation can cause disturbances in other equipment, in installations (e.g., medical ones such as pacemakers or hearing aids) and in aircraft. It can also affect humans and animals.

Precautions:

Although this product conforms to the most stringent standards and regulations, the possibility of harm to people and animals cannot totally be excluded.

  • Do not use the product near petrol stations, chemical plants, in areas with a potentially explosive atmosphere and where blasting takes place.
  • Do not use the product near medical equipment.
  • Do not use the product in airplanes.
  • Do not use the product near your body for extended periods.
Models: LD 250 BT, 165ft Bluetooth Laser Distance Measurer, LD 250 BT 165ft Bluetooth Laser Distance Measurer, Bluetooth Laser Distance Measurer, Laser Distance Measurer, Distance Measurer, Measurer

PDF preview unavailable. Download the PDF instead.

18817 instruction Adobe Acrobat Pro 10.1.15 iLovePDF

Related Documents

Preview STABILA LD 320 Laser Distance Measuring Instrument User Manual
Comprehensive user manual for the STABILA LD 320 laser distance measuring instrument, covering setup, operations, measuring functions, technical specifications, and safety guidelines.
Preview STABILA LAR 350 Rotation Laser: Tough 2-Axis Inclination Laser for Construction
Discover the STABILA LAR 350, a tough 2-axis inclination laser designed for optimal performance on construction sites. Featuring innovative MOTION CONTROL and LED ASSIST systems for intuitive operation and visual monitoring, this laser ensures precision and efficiency in all measuring tasks.
Preview STABILA LAR 160 / LAR 160 G Operating Instructions
Operating instructions for the STABILA LAR 160 and LAR 160 G rotation lasers, covering intended use, safety, components, commissioning, operating modes, functions, LED indicators, accuracy checks, and technical data.