User Guide for ZKTeco models including: ProFace X, TD, ZKTeco
2020-04-01 14:20:43 Area Name 192.168.1.120 192.168.1.120-1 2 36.0 Normal 2 0-4 1 1 :5 1 Ar ea N ame 1 9 .1 68 1 J k S l s 3 N Exc ption Close Number 1 First Name Jack Depertment Sales Body temperature 37.7 Area Area Name Device 192.168.1.120 Time 2020-04-01 10:50:21
For more details, please refer to the ZKBioAccess EP User Manual. 1. Click [Access] > [Access Device] > [Device] > [Search Device] to add the device to the software. When the device has set the server address and port, it can be added automatically. Step 1 Step 2 Step 3 Step 4 Add Device Name Ic on Type Area Add to Level Clear Data in the ...
File Info : application/pdf, 17 Pages, 3.14MB
DocumentDocumentQuick Start Guide ProFace X [TD] Version: 1.0 Date: April 2020 1Overview Flash Thermal infrared temperature measurement module Near-infrared flash Camera & palm collector Microphone (Optional) 8-inch touchscreen Tamper switch RS232 RS485 12V 12V GND GND GND RXD1 TXD1 485B 485A GND 12V Wiegand Out Wiegand In WD1 WD0 INWD1 INWD0 GND 12V Speaker Reset button 1 Power interface +12V GND GND AUX GND SEN GND BUT NO COM NC ALAL+ Power Auxiliary input Sensor Exit button Lock Alarm Networkinterface 2 Installation Environment Please refer to the following recommendations for installation. window 6.5ft 10ft INDOOR USE KEEP DISTANCE 3 Device Installation AVOID GLASS REFRACTION AVOID DIRECT SUNLIGHT AND EXPOSURE KEEP EFFECTIVE DISTANCE 0.3-2.5m Install on the wall Attach the mounting template sticker to the wall, and drill holes according to the mounting paper. Fix the back plate on the wall using wall mounting screws. Attach the device to the back plate. Fasten the device to the back plate with a security screw. 1 2 1.5m 3 4 2 3 Device Installation Install on the barrier gate Please thread the wire through the bracket before installation. Drill a hole on the barrier gate, insert the bracket into the hole and fix it with a nut. Adjust the angle of the device. 1 2 3 4 Standalone Installation Alarm Door sensor Reader Lock dSemteocktoer Exit button TCP/IP PC 5 Door Sensor, Exit Button & Alarm Connection Detector power + + - - + Smokedetector Exitbutton Alarm - GND AUX GND SEN GND BUT NO COM NC ALAL+ - + Alarm power Door sensor 4 6 Lock Relay Connection The system supports Normally Opened Lock and Normally Closed Lock. The NO LOCK (normally unlocked when power-on) is connected with 'NO' and 'COM' terminals, and the NC LOCK (normally locked when power-on) is connected with 'NC' and 'COM' terminals. Take NC Lock as an example below: 1)Device not sharing power with the lock2)Devicesh aring power with the lock DC12V GND +12V DC12V +12V GND Maximum 30V 3A input. DC12V FR107 Normally Closed Lock GND AUX GND SEN GND BUT NO COM NC ALAL+ FR107 Normally Closed Lock GND AUX GND SEN GND BUT NO COM NC ALAL+ 7 Wiegand Reader Connection WD1 WD0 INWD1 INWD0 GND 12V 5 Access controller GND +12V Wiegand reader 8 Barrier Connection 12V 12V GND GND GND RXD1 TXD1 485B 485A GND 12V 9 RS485 Connection Barrier gate 12V 12V GND GND GND RXD1 TXD1 485B 485A GND 12V +12V GND 485485+ GND 485 reader Note: 485A and 485B can be connected to the barrier gate or the 485 reader, but cannot be connected to the gate and the reader at the same time. 6 10 Power Connection 12V3ADC Recommended power supply: 12V - 3A To share the power with other devices, use a power supply with higher current ratings. 11 Ethernet Connection Connect the device and computer software over an Ethernet cable. An example is shown below: ZKBioAccessEP Default IP address: 192.168.1.201 Subnet mask: 255.255.255.0 IP address: 192.168.1.130 Subnet mask: 255.255.255.0 Note: In LAN, IP addresses of the server (PC) and the device must be in the same network segment when connecting to ZKBioAccess EP software. Click on [Comm.] > [Ethernet] > [IP Address], input the IP address and click on [OK]. 7 12 UserRegistration When there is no super administrator set in the device, click on to enter the menu. After setting the super administrator, the system will request for the administrator's verification before entering the menu. For the security purpose, it is recommended to register a super administrator at the first time you use the device. Method1: Register on the device Clickon> [User Mgt.] > [New User] to register a new user. Settings include entering user ID and name, registering palm, face, password and user photo, setting user role and access control role. L L L Enroll Palm 8 Method 2: Register on ZKBioAccess EP software Please set the IP address and cloud service server address on the device. 1. Click [Access] > [Access Device] > [Device] > [Search Device] to add the device to the software. When the device has set the server address and port, it can be added automatically. Refresh Search TotalProgress IP Address New Delete Export Search Device Device Control Set up Step1 No device found? Download Search Tools to Local Disk Search Device Step2 Device Type Searched devicescount:1 Serial Number IP Address 192.168.213.79 MAC Address Subnet Mask 255.255.255.0 Gateway Address 192.168.213.1 Serial Number Device Type View and Get Device Info Communication Set Server OperationsStep3 Add Add Device Name Icon Type Area The current systen communication port is 6609, please make sure the device is set correctly. Add to Level Clear Data in the Device wChleonseAdding 192.168.213.79 Door Area Name [ClearDataintheDevicewhenAdding]willdeletedatainthedevice(exceptevent record), pleaseusewithcaution! SStetepp44 OK Cancel 2. Click [Personnel] > [Person] > [New] to register users in the software. 3. Add users to access levels. 4. Click [Access] > [Device] > [Device Control] > [Synchronize All Data to Devices]. For more details, please refer to the ZKBioAccess EP User Manual. 9 Method 3: Register on the phone Once ZKBioAccess EP software installed, users could enroll face via browser application on their own mobile phone. 1. Click [Personnel] > [Parameters], input `'http://Server address:Port'' in the QR Code UGL bar. The software will automatically generates a QR code. Scan the QR code or login onto `'http://Server address:Port/app/v1/adreg''by the mobile phone to register users. Personnel Registration Personnel Registration Personnel ID 4835 First Name Mike Last Name Last Name Personnel Person Department Temporary Personnel Custom Attributes Parameters Personnel ID Setting The Maximum Length: 9 Support Letters: Yes No Personnel ID Auto-increment: Yes No Card Setting The Maximum Length: 32 Bits(Binary) Card Format Display: Decimal Hexadecimal Temporary Personnel Setting Enable Temporary Personnel Auto-audit: Yes No Self-service Registration QR Code URL: http://Server address:Port Download QR code image Card Management OK 2. The users will display in [Personnel] > [Temporary Personnel], click [Review]. Personnel Person Department Temporary Personnel Custom Attributes Parameters Personnel ID The current query conditions None Refresh Review Delete Name Personnel ID First Name Last Name 4835 Mike Mobile Phone Welcome, admin Status Create Time Operations Delete Card Management 1-1 50 rows per page Jump To 1 /0 Page Total of 0 records 10 13 Access Control Settings Clickon > [Access Control]to enter the access control management interface and set relevant parameters of access control. L 14 Ethernet and Cloud Server Settings Clickon > [Comm.] > [Ethernet]to set the network parameters. If the TCP/IP communication of the device is successful, the icon will be displayed in the upper right corner of the standby interface. Clickon > [Comm.] > [Cloud Server Setting] to set the server address and server port,that is, the IP address and port number of the server after the software is installed. If the device communicates with the server successfully, the icon will be displayed in the upper right corner of the standby interface. L 11 15 Detection Management Settings Click on > [System] > [Detection Management]to enter the detection management interface. You can set the value of High temperature alarm threshold. The device will send an alarm prompt when the temperature of the user detected exceeds this value. When the Temperature over the range; access denied is enabled, the user will be forbidden to access, as shown in the following figure. L L Detection Management Enable temperature screening with infrared High temperature alarm threshold Low temperature alarm threshold Temperature over the range; access denied Temperature deviation correction Temp. Unit Enable mask detection Deny access without mask 08:50 Normal temperature Measure Temp. Temp.: 36.65OC 08:50 Temperature over the range Measure Temp. Temp.: 37.65OC Mask Detected Successfully verified Name:Mike User ID:4835 Verify:Face Without mask Successfully verified Name:Mike User ID:4835 Verify:Face 12 Note: 1. The effective distance for temperature detection is within 50cm. 2. Recommended for indoor use. 3. Temperature measurement data is for reference only, not for medical use. 4. Remove the mask to register the face, wear a mask to recognize the face, the type of mask, the size of the face covered by the mask, and bangs will affect the facial recognition effect. 5. Facial verification for masked individuals will increase FAR. Palm verification for masked individuals is recommended. Effective distance Effective distance: Temperature: 30-50cm Face : 0.3-2.5m Real-time monitoring on ZKBioAccess EP software Once ZKBioAccess EP software installed, users could perform epidemic management on browser. Please set the IP address and cloud service server address on the device and add the device to the software. 1. Click [Prevention] > [Epidemic] > [Real-time monitoring] to view all the events include the user whose temperature is over the range. When the Alarm temperature setting has set, the abnormal body temperature will be marked red automatically. 1. Click [Prevention] > [Epidemic] > [Real-time monitoring] to view all the events include the user whose temperature is over the range. When the Alarm temperature setting has set, the abnormal body temperature will be marked red automatically. 2. Click [Epidemic] > [Statistics panel] to view the analysis of statistical data and view the personnels with normal temperature. As shown in the following figure. 13 Area Device Name Temperature management Real-time monitoring Statistics panel Temperature Raw Record Personnel temperature schedule Alarm temperature setting Time Area Device 2020-04-01 14:20:53 Area Name 192.168.1.120 2020-04-01 14:20:43 Area Name 192.168.1.120 2020-04-01 10:50:21 Area Name 192.168.1.120 Abnomal temperature record Departmental body temperature daily statistics report Status ............... Event Point Personnel ID First Name 192.168.1.120-1 2 192.168.1.120-1 2 192.168.1.120-1 2 Jack Welcome, admin Department Sales Body temperature 36.0 36.0 36.0 Mask None Alarm alert Status Normal Normal Exception Total Received:2 Normal:2 Exception:1 Alarm:0 Clear Data Rows Number 1 First Name Jack Depertment Sales Body temperature 37.7 Area Area Name Device Time 192.168.1.120 2020-04-01 10:50:21 Close Sounds Reminder Show Photos Epidemic management Real-time monitoring Statistics panel Temperature Raw Record Personnel temperature schedule Statistics Time This week The current query conditions None Refresh Abnomal temperature record Departmental body temperature daily statistics report dy temperature Normal temperature Welcome, admin ViewNormal temperaturePeople Personnel ID Department Name The current query conditions None Refresh Personnel ID First Name Department Department Name Number 3 1 Sales 2 1 Sales Temperature abnormal Normal temNpoerrmataulrteemperaturTeemperature abnormal Unmeaured body temperature 1-2 50 rows per page Jump To 1 /1 Page Total of 2 records For more details, please refer to the ZKBioAccess EP User Manual. 14 16 Method for Enrolling Palm 30-50cm Note: 1. Place your palm within 30-50cm of the device. 2. Place your palm in the palm collection area, such that the palm is placed parallel to the device. 3. Make sure to keep space between your fingers. 15 www.zkteco.eu Copyright©2020 ZKTeco CO., LTD. All rights reserved.