R. STAHL Miniature Circuit Breaker

Model: 8530/1-MCB-STA103N-B6-000-4

Article No.: 293843

Components for System Solutions

The R. STAHL 8530 series miniature circuit breakers (MCBs) are overcurrent devices designed for system solutions. They offer excellent current limiting for short circuits and a high switching capacity of 10, 15, or 25 kA, resulting in reduced load on cables and improved selectivity for upstream fuses.

These components feature a modular design and are available in 1- to 4-pole versions, with rated currents ranging from 0.5-63 A. The maximum installation capacity is 4.5 subunits.

Key Features:

Technical Data

Explosion Protection

Application range (zones) 1, 2
Application range (Zone) note For use in Zone 21/22 when protected by Ex tb/tc enclosure
IECEx gas certificate IECEx FMG 19.0029U
IECEx gas explosion protection Ex db eb IIC Gb
ATEX gas certificate FM19ATEX0191U
ATEX gas explosion protection II 2 G Ex db eb IIC Gb
Certificates ATEX (FM), Brazil (ULB), China (CQST), IECEx (FM)
Declaration of conformity Certificate of conformity (ATEX)

Electrical Data

Rated operational voltage AC 230/400 V
Rated operational current 6 A
Frequency 50/60 Hz
Rated switching capacity 10 kA
Electrical service life 2 x 10⁴
Mechanical service life 2 x 10⁴
1st auxiliary function without
2nd auxiliary function without
Tripping characteristic B
No. of poles 3-pole + N

Ambient Conditions

Ambient temperature -40 °C ... 70 °C
Ambient temperature -40 °F ... 158 °F
Ambient temperature note Deviating ambient temperatures based on current certificates available on request

Mechanical Data

Degree of protection (IP) (IEC 60529) IP2X
Enclosure material Thermoplast
Connection cross section min. 1.5 mm²
Connection cross-section max. 25 mm²
Connection cross-section AWG min. 16 AWG
Connection cross-section AWG max. 4 AWG
Connection cross-section 2 min. 1.5 mm²
Connection cross-section 2 max. 10 mm²
Connection cross-section 2 AWG min. 16 AWG
Connection cross-section 2 AWG max. 8 AWG
Min. tightening torque 2 N·m
Max. tightening torque 3 N·m
Connection cross-section note 2-conductor connection (upper and lower chamber at the same time): upper and lower chamber max. 16/10 mm² (A maximum difference of one cross section may be clamped between the upper and lower chamber.) The permitted combinations of connection cross-sections can be found in the operating instructions.
Width 110 mm
Width, inches 4.33 in
Length 165 mm
Length in inches 6.5 in
Mounting depth 138.3 mm
Mounting depth in inches 5.44 in
Weight 1.8 kg
Weight 3.969 lb

Mounting / Installation

Tightening torque 2-3 N·m
Tightening torque lbf in 17.7 to 26.6 lbf-in
Tightening torque auxiliary contact 0.4 - 0.6 N·m
Tightening torque auxiliary contact lbf in 3.5 to 5.3 lbf in

Technical Drawings

Tripping Characteristic B:

A graph illustrates the tripping time in seconds and minutes against the multiple of rated current for tripping characteristic B, showing the performance from a cold state for AC and DC.

Dimensional Drawings:

Diagrams show the dimensions of the MCB in millimeters and inches, including width, length, and mounting depth. It also depicts a 3-pole + N configuration without an auxiliary contact.

Accessories

Note: R. STAHL reserves the right to make alterations to technical data, dimensions, weights, designs, and products without prior notice. Illustrations are not binding.

PDF preview unavailable. Download the PDF instead.

ex-ficha-tecnica-individual-disyuntor-8530-1-mcb-sta103n-b6-000-4-293843-en-gb-rstahl Adobe PDF Library 17.0

Related Documents

Preview R. STAHL 8530 Series Miniature Circuit Breaker (MCB) - Technical Data and Specifications
Detailed technical specifications for the R. STAHL 8530 series miniature circuit breaker (MCB), model 8530/1-MCB-STA103N-C20-000-4. Includes information on explosion protection, electrical data, mechanical data, ambient conditions, and accessories.
Preview R. STAHL Miniature Circuit Breaker 8530/1-MCB-STA103N-B32-000-4: Technical Specifications and Features
Detailed technical specifications, features, and accessories for the R. STAHL Miniature Circuit Breaker, model 8530/1-MCB-STA103N-B32-000-4. Includes explosion protection, electrical data, mechanical data, and installation information.
Preview R. STAHL 8530/1-MCB-STA101-B6-500-2 Miniature Circuit Breaker - Technical Specifications
Detailed technical specifications for the R. STAHL 8530/1-MCB-STA101-B6-500-2 miniature circuit breaker, including explosion protection, electrical data, mechanical data, and accessories.
Preview R. STAHL MCB Miniature Circuit Breaker 8530/1-MCB-STA103N-C16-100-4: Technical Specifications and Features
Detailed technical specifications, features, and accessories for the R. STAHL MCB Miniature Circuit Breaker, model 8530/1-MCB-STA103N-C16-100-4 (Art. No. 293876). Includes explosion protection, electrical data, mechanical data, and mounting information.
Preview R. STAHL 8530/1-MCB-STA102-B6-500-3 Miniature Circuit Breaker Technical Data
Detailed technical specifications and features of the R. STAHL 8530/1-MCB-STA102-B6-500-3 miniature circuit breaker, including explosion protection, electrical data, mechanical data, and accessories.
Preview R. STAHL MCB Miniature Circuit Breaker 8530/1-MCB-STA103-C10-000-3: Technical Specifications and Features
Detailed technical specifications, features, and accessories for the R. STAHL 8530/1-MCB-STA103-C10-000-3 miniature circuit breaker, including explosion protection, electrical data, ambient conditions, and mechanical data.
Preview R. STAHL 8530/1-MCB-STA103N-B6-000-4 Line Protection Circuit Breaker Technical Data
Technical specifications and features of the R. STAHL 8530/1-MCB-STA103N-B6-000-4 line protection circuit breaker, including explosion protection, electrical characteristics, mechanical specifications, and accessories.
Preview R. STAHL MCB Miniature Circuit Breaker 8530/1-MCB-STA102-B10-000-2: Technical Specifications and Features
Detailed technical specifications, features, and accessories for the R. STAHL 8530 series MCB miniature circuit breaker (Art. No. 293915), including explosion protection, electrical data, mechanical data, and mounting information.