CommScope Fiber Indoor Cable
760259056 | P-036-MP-CM-F12RD/8W012 /5K024
This document provides detailed specifications for the CommScope 760259056, a fiber indoor cable featuring TeraSPEED® and LazrSPEED® Plenum MPO Trunk technology. It is a 36-fiber multi-unit cable with 12-fiber subunits, a gel-free construction, feet jacket marking, and a red jacket color.
Product Classification
Regional Availability: Asia | Australia/New Zealand | Latin America | Middle East /Africa | North America
Portfolio: CommScope®
Product Type: Fiber indoor cable
Product Series: P-MP
General Specifications
Cable Type | MPO trunk cable |
Construction Type | Non-armored |
Subunit Type | Gel-free |
Jacket Color | Red |
Fiber Color Code | TIA-598 |
Jacket Marking | Feet |
Subunit, quantity | 3 |
Fibers per Subunit, quantity | 12 |
Composite Fiber Count | 12 + 24 |
Total Fiber Count | 36 |
Dimensions
Buffer Tube/Subunit Diameter | 3 mm | 0.118 in |
Diameter Over Jacket | 9.1 mm | 0.358 in |
Cable Construction
The cable features an outer jacket, a rip cord for easy access, 12 individual fiber subunits, and a central member providing structural integrity.
Mechanical Specifications
Minimum Bend Radius, loaded | 136 mm | 5.354 in |
Minimum Bend Radius, unloaded | 91 mm | 3.583 in |
Tensile Load, long term, maximum | 400 N | 89.924 lbf |
Tensile Load, short term, maximum | 1335 N | 300.12 lbf |
Compression | 10 N/mm | 57.101 lb/in |
Compression Test Method | FOTP-41 | IEC 60794-1 E3 |
Flex | 300 cycles |
Flex Test Method | FOTP-104 | IEC 60794-1 E6 |
Impact | 0.74 N-m | 6.55 in lb |
Impact Test Method | FOTP-25 | IEC 60794-1 E4 |
Strain | See long and short term tensile loads |
Strain Test Method | FOTP-33 | IEC 60794-1 E1 |
Twist | 10 cycles |
Twist Test Method | FOTP-85 | IEC 60794-1 E7 |
Vertical Rise, maximum | 500 m | 1,640.42 ft |
Optical Specifications
Fiber Type: G.652.D and G.657.A1, TeraSPEED® | OM4, LazrSPEED® 550
Environmental Specifications
Installation temperature | 0 °C to +70 °C (+32 °F to +158 °F) |
Operating Temperature | 0 °C to +70 °C (+32 °F to +158 °F) |
Storage Temperature | -40 °C to +70 °C (-40 °F to +158 °F) |
Cable Qualification and Environmental Test Specifications
Cable Qualification Standards: ANSI/ICEA S-83-596 | Telcordia GR-409
Environmental Space: Plenum
Flame Test Listing: NEC OFNP (ETL) and c(ETL)
Flame Test Method: NFPA 130 | NFPA 262
Environmental Test Specifications
Heat Age | 0 °C to +85 °C (+32 °F to +185 °F) |
Heat Age Test Method | IEC 60794-1 F9 |
Low High Bend | 0 °C to +70 °C (+32 °F to +158 °F) |
Low High Bend Test Method | FOTP-37 | IEC 60794-1 E11 |
Temperature Cycle | 0 °C to +70 °C (+32 °F to +158 °F) |
Temperature Cycle Test Method | FOTP-3 | IEC 60794-1 F1 |
Packaging and Weights
Cable weight: 75 kg/km | 50.398 lb/kft
Included Products
- CS-5K-MP: LazrSPEED® 550 OM4 Bend-Insensitive Multimode Fiber
- CS-8W-MP: TeraSPEED® OS2 Singlemode Fiber
Footnotes
Operating Temperature: Specification applicable to non-terminated bulk fiber cable