CommScope P-012-MP-8W-F12YL Fiber Indoor Cable

This document provides detailed specifications for the CommScope P-012-MP-8W-F12YL, a TeraSPEED® Plenum fiber indoor cable designed for MPO Trunks. It features 12 fibers of Singlemode G.652.D and G.657.A1, with Feet jacket marking and a Yellow jacket color.

Cable Structure

The cable construction includes a yellow outer jacket, a ripcord, aramid yarn for strength, and a 12-fiber subunit.

Product Classification

Regional AvailabilityAsia/Africa, Australia/New Zealand, North America, Latin America, Middle East
PortfolioCommScope®
Product TypeFiber indoor cable
Product SeriesP-MP

General Specifications

Cable TypeMPO trunk cable
Construction TypeNon-armored
Subunit TypeGel-free
Jacket ColorYellow
Jacket MarkingFeet
Total Fiber Count12

Dimensions

Buffer Tube/Subunit Diameter3 mm | 0.118 in
Diameter Over Jacket4.9 mm | 0.193 in

Mechanical Specifications

Minimum Bend Radius, loaded74 mm | 2.913 in
Minimum Bend Radius, unloaded49 mm | 1.929 in
Tensile Load, long term, maximum200 N | 44.962 lbf
Tensile Load, short term, maximum667 N | 149.948 lbf
Compression10 N/mm | 57.101 lb/in
Compression Test MethodFOTP-41 | IEC 60794-1 E3
Flex300 cycles
Flex Test MethodFOTP-104 | IEC 60794-1 E6
Impact0.74 N-m | 6.55 in lb
Impact Test MethodFOTP-25 | IEC 60794-1 E4
StrainSee long and short term tensile loads
Strain Test MethodFOTP-33 | IEC 60794-1 E1
Twist10 cycles
Twist Test MethodFOTP-85 | IEC 60794-1 E7
Vertical Rise, maximum500 m | 1,640.42 ft

Optical Specifications

Fiber TypeG.652.D and G.657.A1, TeraSPEED® | OS2 | OS2

Environmental Specifications

Installation temperature0 °C to +70 °C (+32 °F to +158 °F)
Operating Temperature0 °C to +70 °C (+32 °F to +158 °F)

Storage and Environmental Testing

Storage Temperature-40 °C to +70 °C (-40 °F to +158 °F)
Cable Qualification StandardsANSI/ICEA S-83-596 | Telcordia GR-409
Environmental SpacePlenum
Flame Test ListingNEC OFNP (ETL) and c(ETL)
Flame Test MethodNFPA 130 | NFPA 262
Heat Age0 °C to +85 °C (+32 °F to +185 °F)
Heat Age Test MethodIEC 60794-1 F9
Low High Bend0 °C to +70 °C (+32 °F to +158 °F)
Low High Bend Test MethodFOTP-37 | IEC 60794-1 E11
Temperature Cycle0 °C to +70 °C (+32 °F to +158 °F)
Temperature Cycle Test MethodFOTP-3 | IEC 60794-1 F1

Packaging and Weights

Cable weight23 kg/km | 15.455 lb/kft

Regulatory Compliance and Certifications

AgencyClassification
CHINA-ROHSBelow maximum concentration value
ISO 9001:2015Designed, manufactured and/or distributed under this quality management system
REACH-SVHCCompliant as per SVHC revision on https://www.commscope.com/ProductCompliance
ROHSCompliant
UK-ROHSCompliant

Included Products

  • CS-8W-MP - TeraSPEED® OS2 Singlemode Fiber

Fiber Specifications (CS-8W-MP)

General Specifications

Cladding Diameter125 µm
Cladding Diameter Tolerance±0.7 µm
Cladding Non-Circularity, maximum0.7%
Coating Diameter (Colored)249 µm
Coating Diameter (Uncolored)242 µm
Coating Diameter Tolerance (Colored)±13 µm
Coating Diameter Tolerance (Uncolored)±5 µm
Coating/Cladding Concentricity Error, maximum12 µm
Core Diameter8.3 µm
Core/Clad Offset, maximum0.5 µm
Proof Tensile Stress100,000 psi (0.69 GPa)

Dimensions

Fiber Curl, minimum4 m | 13.123 ft

Mechanical Specifications

Macrobending, 20 mm Ø mandrel, 1 turn0.75 dB @ 1,550 nm | 1.50 dB @ 1,625 nm
Macrobending, 30 mm Ø mandrel, 10 turns0.25 dB @ 1,550 nm | 1.00 dB @ 1,625 nm
Macrobending, 60 mm Ø mandrel, 100 turns0.05 dB @ 1,550 nm | 0.05 dB @ 1,625 nm
Coating Strip Force, maximum8.9 N | 2.001 lbf
Coating Strip Force, minimum1.3 N | 0.292 lbf
Dynamic Fatigue Parameter, minimum20

Optical Specifications

Cabled Cutoff Wavelength, maximum1260 nm
Point Defects, maximum0.1 dB
Zero Dispersion Slope, maximum0.092 ps/[km-nm-nm]
Zero Dispersion Wavelength, maximum1324 nm
Zero Dispersion Wavelength, minimum1300 nm

Optical Specifications, Wavelength Specific

ParameterValue
Attenuation, maximum0.40 dB/km @ 1,310 nm | 0.40 dB/km @ 1,385 nm | 0.40 dB/km @ 1,490 nm | 0.40 dB/km @ 1,550 nm | 0.50 dB/km @ 1,270 nm | 0.50 dB/km @ 1,575 nm
Backscatter Coefficient-79.6 dB @ 1,310 nm | -82.1 dB @ 1,550 nm
Dispersion, maximum18 ps(nm-km) at 1550 nm | 3.5 ps(nm-km) from 1285 nm to 1330 nm at 1310 nm
Index of Refraction1.467 @ 1,310 nm | 1.467 @ 1,385 nm | 1.468 @ 1,550 nm
Mode Field Diameter10.4 µm @ 1,550 nm | 9.2 µm @ 1,310 nm | 9.6 µm @ 1,385 nm
Mode Field Diameter Tolerance±0.4 µm @ 1310 nm | ±0.5 µm @ 1550 nm | ±0.6 µm @ 1385 nm
Polarization Mode Dispersion Link Design Value, maximum0.06 ps/sqrt(km)
Standards ComplianceITU-T G.652.D | ITU-T G.657.A1 | TIA-492CAAB (OS2)

Environmental Specifications

Heat Aging, maximum0.05 dB/km @ 85 °C
Temperature Dependence, maximum0.05 dB/km
Temperature Humidity Cycling, maximum0.05 dB/km
Water Immersion, maximum0.05 dB/km @ 23 °C

Footnotes

  • Operating Temperature: Specification applicable to non-terminated bulk fiber cable.
  • Temperature Dependence, maximum: Temperature dependence is conducted at -60 °C to +85 °C (-76 °F to +185 °F).
  • Temperature Humidity Cycling, maximum: Temperature humidity cycling is conducted at -10 °C to +85 °C (+14 °F to +185 °F) up to 95% relative humidity.

PDF preview unavailable. Download the PDF instead.

760038307-product-specifications-comprehensive COMMSCOPE

Related Documents

Preview CommScope P-012-MZ-8W-F12YL TeraSPEED Plenum MPO Trunk Cable Specifications
Detailed technical specifications for the CommScope P-012-MZ-8W-F12YL TeraSPEED Plenum MPO Trunk Cable, including mechanical, optical, environmental, and regulatory compliance details. Features 12 fibers, interlocking aluminum armor, and yellow plenum jacket.
Preview CommScope P-012-MP-8W1C-F30YL Fiber Indoor Cable - Technical Specifications
Detailed technical specifications for the CommScope P-012-MP-8W1C-F30YL MPO trunk cable, featuring 12 fibers, Singlemode G.652.D and G.657.A1, Plenum rating, and yellow jacket.
Preview CommScope TeraSPEED P-024-MP-8W-F12BK Fiber Optic Cable Specifications
Detailed technical specifications for the CommScope TeraSPEED P-024-MP-8W-F12BK fiber indoor cable, covering product classification, general, mechanical, optical, environmental, and regulatory compliance details.
Preview CommScope TeraSPEED® P-096-MP-8W-F12YL Fiber Indoor Cable Specifications
Detailed technical specifications for the CommScope TeraSPEED® P-096-MP-8W-F12YL Plenum MPO Trunk Cable, featuring 96 single-mode fibers, G.652.D and G.657.A1 compatibility, and yellow jacket.
Preview CommScope P-024-MP-8W-F120R TeraSPEED Fiber Indoor Cable Specifications
Detailed technical specifications for the CommScope P-024-MP-8W-F120R TeraSPEED Plenum MPO trunk fiber indoor cable, including mechanical, optical, environmental, and regulatory compliance data.
Preview CommScope P-048-MP-8W-F120R TeraSPEED Plenum MPO Trunk Cable Specifications
Detailed specifications for the CommScope P-048-MP-8W-F120R TeraSPEED Plenum MPO Trunk Cable, featuring 48 fibers, Singlemode G.652.D/G.657.A1, gel-free construction, and orange jacket.
Preview CommScope P-072-MP-8W-F12GR TeraSPEED Fiber Indoor Cable Specifications
Detailed technical specifications for the CommScope P-072-MP-8W-F12GR TeraSPEED Plenum MPO Trunk fiber indoor cable, including mechanical, optical, environmental, and regulatory compliance data.
Preview CommScope TeraSPEED® Plenum MPO Trunk Cable P-048-MP-8W-F12WH - Technical Specifications
Detailed technical specifications for the CommScope TeraSPEED® Plenum MPO Trunk Cable (P-048-MP-8W-F12WH), including product classification, general, mechanical, optical, environmental, and regulatory compliance data.