PRODUCT MANUAL
Professional DMX AES/EBU Cable Assemblies
1 PRODUCT EXAMPLE
The product Professional DMX AES/EBU Cable uses a 20 m cable. It is assembled with NEUTRIK NC3FXX-B and NC3MXX-B. It contains exclusive re-usable velcro straps and unshrinked tubes for labeling.
2 GENERAL
When flawless signal transmission is critical on stage, in the studio, or across complex installations the NEUTRIK® Professional DMX AES/EBU Cable Assemblies deliver exactly what professionals need. Designed for digital lighting control (DMX512 / DMX512-A) and digital audio interconnects (AES/EBU), these cable assemblies ensure stable, interference resistant performance in any professional environment. Whether you're managing moving lights in a live show, integrating a theatre lighting grid, or routing audio control data in a broadcast facility, these assemblies provide extreme reliability with the build quality and signal consistency expected from Neutrik.
A TECHNICAL DATA
Product | Profesional DMX AES/EBU Cables Assemblies (NKX*D1*-X*X*-M*) |
Title | premium DATA CABLES |
Product group | DATA CABLES |
Product family | NEUTRIK® XLR |
Connection type | |
Electrical | |
Characteristical impedance | 120 Ω @ 1 kHz (nominal) |
Attenuation | 2.0 dB/100 m @ 1 MHz (nominal) |
Capacitance | Cable conductor to conductor: 55 pF/m @ 1 kHz Cable conductor to shield: 110 pF/m @ 1 kHz 3 Pin connector contact to contact: ≤ 4 pF 5 Pin connector contact to contact: ≤ 7 |
Conductor resistance | 0.22 mm²/AWG 24: ≤ 80 mΩ/m @ 20 °C (nominal) 0.34 mm²/AWG 22: ≤ 55 mΩ/m @ 20 °C (nominal) |
Contact resistance | ≤ 3 mΩ |
Insulation resistance | Cable: > 1 GΩ/m @ 20 °C, 500 VDC Connector: > 10 GΩ (initial) |
Dielectric strenght | Cable conductor to screen: 1000 VAC @ 50 Hz, 1 min. Connector: 1.5 kVDC |
Mechanical | |
Insertion force | ≤ 20 N |
Withdrawal force | ≤ 20 N |
Lifetime | min. 1000 mating cycles |
Locking device | Latch lock |
Minium bending radius | approx. 65 mm |
Wiring | Soldered |
Composition of conductor | 0.22 mm² / AWG 24: 7 x 0.20 mm OFC 0.34 mm² / AWG 22: 19 x 0.15 mm OFC |
Composition of drain wire | 7 x 0.20 mm OFC (0.22 mm² / AWG 24 only) |
Shielding | 0.22 mm² / AWG 24: Foil + Braided (≥60%) 0.34 mm² / AWG 22: Spiral (≥95%) |
Overall diameter | 6.5 +/- 0.15 mm |
Mechanical | |
Wire | Annealed copper |
Wire Insulation | Foamed PE |
Drain Wire | Tinned copper (0.22 mm² / AWG 24 only) |
Filler | Cotton (0.34 mm² / AWG 22 only) |
Shield | 0.22 mm² / AWG 24: AL/PT Foil + Tined Copper 0.34 mm² / AWG 22: Tinned Copper |
Outer Jacket | PVC |
Connector | See datasheets of NEUTRIK® NC3FXX-B, NC3MXX-B, NC5FXX-B, NC5MXX-B |
Environmental | |
Standard compliance | DMX512 / DMX512-A according to ANSI E1.11 AES/EBU according to AES3 RoHS according to 2011/65/EU |
Ingress protection class | IP20 |
Temperature range | Mobile: -10 °C to +70 °C Fixed: -20 °C to +70 °C |
B ASSEMBLY HEAT SHRINK TUBING
The shrink tubing serves as an optional protective device for a label applied to the cable by a third person.
- Shrinking of the shrink tubing is not necessary for the operation of the cable
- Shrinking of the heat shrinkable tubing is done at your own risk. The manufacturer is not liable for any damage to the cable caused by processing the shrink tubing.
- Shrinking of the shrink tubing with open flame and hot air devices without temperature adjustment is not permitted.
- Permissible temperature range for shrinking is 70°C to 90°C.
- The cable must be free of tension during shrinking.
C „TYPE KEY“ EXAMPLE FOR ARTICLES
NEUTRIK XLR Cable
CONNECTOR TYPE
3: 3 Pin Connectors
5: 5 Pin Connectors
CABLE TYPE
D1: 1 DMX Channel (PVC Sheath)
D2: 2 DMX Channels (PVC Sheath)
TD1: 1 DMX Channel (PUR Sheath - TOP)
TD2: 2 DMX Channels (PUR Sheath -
CROSS SECTION TYPE
22: 0.22mm² Cross Section Wires
34: 0.34mm² Cross Section Wires.
CONNECTOR COMBINATION
X1X1: NC3FXX-B / NC3MXX-B
X2X2: NC5FXX-B / NC5MXX-B
LENGTH
M0050: 0.5 m
M0100: 1 m
M0150: 1.5 m
M0300: 3 m
M0500: 5 m
M1000: 10 m
M1500: 15 m
M2000: 20 m
M2500: 25 m
M3000: 30 m
M4000: 40 m
M5000: 50 m
UNIT OF LENGTH
Metric: in m
D DISPOSAL
Electronic devices are recyclable materials and do not belong in household waste. Dispose of the product at the end of its service life in accordance with the applicable legal regulations.
E APPLICATION AND SAFETY INSTRUCTIONS
3 Application and Safety Instructions
A Assembly
Replacement parts are suitable only when used in combination with the designated components. The product's characteristics are guaranteed only in the intended combination.
B Application
- When used with other products, suitability and safety must be assessed and appropriate safety measures must be taken if necessary.
- The product is not intended for use in medical applications.
- The product is not intended for for use in potentially explosive or flammable environments.
C Operation
- Before plugging in, check the contact area for dry surfaces.
- Product surfaces may cause burns at elevated ambient temperatures. Ensure the use of appropriate protective equipment.
- Neutrik products should only be combined with products from Neutrik Group brands.
D Cleaning
- Clean only with dry and lint-free materials or compressed air. of cleaning agents.
- The product must not be cleaned while under load. The product may only be cleaned while it is not connected to any voltage and without the use of cleaning agents.
E Damages
- Handle products with care.
- In case of visible damages, check the suitability of the product for use.
i More Information on the website
https://www.neutrik.com/de/Professional%20DMX%20AES/EBU%20Cable%20Assemblies