Neutrik etherCON CAT6A Cable Connector Assembly Instructions

NE8MX6-T & NE8MX6-B-T

Tools Required

Cable Specifications

Cable O.D.: 7.0 - 9.5 mm (0.28 - 0.37")

Wire Size: AWG 26/1 - AWG 24/1 (solid) / AWG 27/7 - AWG 24/7 (stranded)

Insulation Diameter: > 0.85 - 1.1 mm (0.033 - 0.043")

Assembly Steps

  1. Step 1: Prepare Cable Entry

    Slide the boot (1) and the chuck (2) onto the cable. For easier assembly, apply some cable pulling lubricant to the cable ends.

    [Diagram A Description: Shows the boot and chuck being slid onto the end of a network cable.]

  2. Step 2: Strip Cable Jacket

    Prepare the cable as shown and strip the outer jacket to a length of 40 mm.

    [Diagram B Description: Illustrates stripping the cable jacket to expose the inner shielding and wires.]

  3. Step 3: Prepare Shielding and Wires

    Follow the procedure based on your cable type:

    • S/FTP: Cut off the braided shield to approximately 10 mm and fold it backwards.
    • U/FTP: Remove the foil of the paired wires and bend back the drain wire for easier handling. The drain wire will be used for grounding.
    • SF/UTP: Cut off the braided shield to approximately 10 mm and fold it backwards. Cut and remove the foil screen.

    [Diagram 2.A, B, C Description: Shows different methods for preparing the shield and drain wire depending on the cable construction (S/FTP, U/FTP, SF/UTP).]

  4. Step 4: Trim Pair Screening

    Remove the pair screening (if existing) to a maximum length of 6 mm.

    [Diagram 3 Description: Shows trimming the individual pair shielding.]

  5. Step 5: Untwist and Arrange Pairs

    Presort and untwist the wire pairs as shown.

    [Diagram 4 Description: Illustrates untwisting the twisted pairs of wires.]

  6. Step 6: Insert Wires into Management

    Insert the wires into the designated positions of the wire management according to the T568A or T568B wiring scheme.

    [Diagram C Description: Shows wires being inserted into the wire management structure, aligning with specific slots.]

    Wiring Scheme:
    ? [Component Side] Connection Color Code (T568A) Color Code (T568B) RJ 45 PIN No.
    1 2 8 7
    3 6 4 5
    1 W-G W-O 1
    2 W-O W-G 2
    3 BL BL 3
    4 W-BL W-BL 4
    5 W-BL W-BL 5
    6 G O 6
    7 W-BR W-BR 7
    8 BR BR 8
  7. Step 7: Press Wire Management

    Use the HX-CAT6A or pliers wrench to press the wire management together.

    Attention: Distance between the cable jacket and the wire management shall not exceed 15 - 17 mm (0.59" - 0.67"). Best return loss: < 15 mm.

    Cut all wires with a wire cutter, allowing them to protrude a maximum of 0.5 mm. Remove the assembly guidance.

    [Diagram D Description: Shows using a tool to compress the wire management and trimming the wire ends.]

  8. Step 8: Position Ground Shells

    Position the ground shells over the wires as shown.

    Attention: Align the coding nibs of the ground shells to the grooves in between the wire pairs in the wire management.

    [Diagram E Description: Illustrates placing the ground shells onto the prepared wires.]

  9. Step 9: Prepare Shield and Drain Wire

    • A. S/FTP & SF/UTP: Put the cable shield over the ground shell and distribute the shield wires circumferentially.
    • B. U/FTP: Put the drain wire over the ground shell and wrap it circumferentially.

    [Diagram F Description: Shows how to position the cable shield and drain wire around the ground shell.]

  10. Step 10: Slide Chuck

    Slide the chuck over the cable-shield / drain wire and the ground shell towards the end-position.

    Attention: Align the slots of the chuck to the ribs of the ground shell.

    [Diagram G Description: Shows sliding the chuck component over the cable assembly.]

  11. Step 11: Insert into Housing

    Slide the pre-assembled cable (from Step 10) into the connector housing.

    Attention: Align the side of the wire management with wire numbers 1/2, 8/7 to the side of the housing that has the Neutrik logo and the slot.

    Slide the gasket onto the chuck.

    [Diagram H Description: Depicts inserting the assembled cable into the main connector body and placing the gasket.]

  12. Step 12: Finish Installation

    Finish the installation by turning the bushing onto the connector.

    ? Option: Use the handtool HTXX-14 to tighten the bushing.

    [Diagram I Description: Shows the final step of screwing the bushing onto the connector.]

Models: NE8MX6-T, NE8MX-T, etherCON NE8MX6-T NE8MX6-B-T CAT6A Cable Connector, etherCON NE8MX6-T NE8MX6-B-T, CAT6A Cable Connector, Cable Connector, Connector

File Info : application/pdf, 2 Pages, 997.88KB

PDF preview unavailable. Download the PDF instead.

BDA 462 V5 - NE8MX6-T - etherCON C6A - Cable Connector (1)

References

Corel PDF Engine Version 26.1.0.143 CorelDRAW 2025

Related Documents

Preview Neutrik etherCON CAT6A Cable Connector Assembly Instructions
Detailed assembly instructions for the Neutrik etherCON NE8MX6-T and NE8MX6-B-T CAT6A cable connector. This guide covers required tools, technical specifications, step-by-step assembly procedures, wire management, and wiring schemes (T568A/T568B), with important attention points for correct installation.
Preview NEUTRIK NE8MXR-B-TOP etherCON Connector - Product Overview
Detailed information on the NEUTRIK NE8MXR-B-TOP etherCON TOP connector, featuring a retractable shell for robust outdoor Ethernet connectivity. Includes technical specifications, features, and benefits.
Preview Neutrik etherCON TOP Cable Connector NE8MXR-B-TOP Product Manual
Detailed product manual for the Neutrik etherCON TOP Cable Connector (NE8MXR-B-TOP). Learn about its rugged design for outdoor use, technical specifications, assembly instructions, application guidelines, and safety information.
Preview Neutrik speakON NL2FXX-W & NL4FXX-W Assembly Instructions
Detailed assembly and disassembly guide for Neutrik speakON NL2FXX-W and NL4FXX-W loudspeaker cable connectors, including safety information, technical specifications, and wiring instructions.
Preview Neutrik NL2FXX-W-S speakON Cable Connector: Features & Technical Specifications
Neutrik NL2FXX-W-S speakON cable connector. This 2-pole connector offers industry-standard reliability for loudspeaker connections with a robust twist-lock system, screw terminals, and chuck type strain relief for cables 6-12mm. Features include high current rating, IEC certification, and durable materials.
Preview Neutrik speakON NEU-NL2FXX-W-S Assembly Instructions
Detailed assembly and disassembly instructions for the Neutrik speakON NEU-NL2FXX-W-S loudspeaker cable connector, including safety information and technical specifications.
Preview Neutrik NDO Dummy Plug: Simplify Cabling and Protect OpticalCON Connectors
Discover the Neutrik NDO dummy plug, an accessory designed to simplify cabling, prevent miswiring errors, and protect unused opticalCON panel mount connectors from dust and debris.
Preview Neutrik NC5FBH1-B Connector: Technical Drawing and Specifications
Detailed technical drawing and specifications for the Neutrik NC5FBH1-B connector, including panel cutout dimensions, PCB layout, and assembly information. Features a push-button mechanism.