Instruction Manual for Value Testers models including: sp100-v, LevelPro ShoPro SP100 Level Display Controller, LevelPro ShoPro SP100, Level Display Controller, Display Controller, Controller
Quick Start Manual. Read the user's manual carefully before starting to use the unit. Producer reserves the right to implement changes without prior notice ...
File Info : application/pdf, 11 Pages, 3.27MB
DocumentDocumentLevelPro® -- ShoPro® SP100 Level Display | Controller Quick Start Manual Read the user's manual carefully before starting to use the unit. Producer reserves the right to implement changes without prior notice. 2F4i-n05d47Q©uaIcolintPyroPcersos Cdounctrtolss LOtdn. line at: Valuetesters.com info@valuetesters.com1 LevelPro® -- ShoPro® SP100 Level Display | Controller Safety Information De-pressurize and vent system prior to installation or removal! Confirm chemical compatibility before use! DO NOT exceed maximum temperature or pressure specifications! ALWAYS wear safety goggles or face-shield during installation and/or service! DO NOT alter product construction! Warning | Caution | Danger Indicates a potential hazard. Failure to follow all warnings may lead to equipment damage, or failure, injury, or death. Note | Technical Notes Highlights additional information or detailed procedure. Basic Requirements & User Safety ? Do not use the unit in areas threatened with excessive shocks, vibrations, dust, humidity, corrosive gasses and oils. ? Do not use the unit in areas where there is risk of explosions. ? Do not use the unit in areas with significant temperature variations, exposure to condensation or ice. ? Do not use the unit in areas exposed to direct sunlight. ? Make sure that the ambient temperature (e.g. inside the control box) does not exceed the recommended values. In such cases forced cooling of the unit must be considered (e.g. by using a ventilator). ? The manufacturer is not responsible for any damages caused by inappropriate installation, not maintaining the proper environmental conditions and using the unit contrary to its assignment. ? Installation should be conducted by qualified personnel . During installation all available safety requirements should be considered. The fitter is responsible for executing the installation according to this manual, local safety and EMC regulations. ? GND input of device should be connected to PE wire. ? The unit must be properly set-up, according to the application. Incorrect configuration can cause defective operation, which can lead to unit damage or an accident. ? If in the case of a unit malfunction there is a risk of a serious threat to the safety of people or property additional, independent systems and solutions to prevent such a threat must be used. ? The unit uses dangerous voltage that can cause a lethal accident. The unit must be switched off and disconnected from the power supply prior to starting installation of troubleshooting (in the case of malfunction). ? Neighboring and connected equipment must meet the appropriate standards and regulations concerning safety and be equipped with adequate overvoltage and interference filters. ? Do not attempt to disassemble, repair or modify the unit yourself. The unit has no user serviceable parts. Defective units must be disconnected and submitted for repairs at an authorized service center. The unit is designed for operation in an industrial environment and must not be used in a household environment or similar. 2F4i-n05d47Q©uaIcolintPyroPcersos Cdounctrtolss LOtdn. line at: Valuetesters.com info@valuetesters.com2 LevelPro® -- ShoPro® SP100 Level Display | Controller Pipe | Pole Mount Brackets NEMA 4X Enclosure Bright LED Display The ShoPro® Series Level Display | Controller is engineered to be the most durable and dependable wall or pipe-mount remote display in the industry. This all-in-one unit is ready to use straight out of the box, featuring a bright LED display, NEMA 4X enclosure, polycarbonate cover, cord grips, and plastic captive screws. Designed for industrial applications, it withstands even the harshest corrosive environments and is available with multiple output options. Features ? All-in-one | Out of the Box Ready to Use ? Visual Alarm -- High | Low Level ? NEMA 4X Enclosure ? Corrosion Resistant Thermoplastic ? Cord Grips Included No Tools Required Push Buttons Polycarbonate Cover Model Selection ShoPro® SP100 -- Liquid Level LED Display Part Number SP100 SP100-A SP100-V SP100-A-V Input 4-20mA 4-20mA 4-20mA 4-20mA Output 4-20mA 2 Relay + 4-20mA + Audible 2 Relay + 4-20mA + Visual 2 Relay + 4-20mA + Audible & Visual Technical Specifications General Display Displayed Values Transmission Parameters Stability LED | 5 x 13mm High | Red -19999 ~ 19999 1200...115200 bit/s, 8N1 / 8N2 50 ppm | °C Housing Material Polycarbonate Protection Class NEMA 4X | IP67 Input Signal | Supply Standard Voltage Current: 4-20mA 85 - 260V AC/DC | 16 - 35V AC, 19 - 50V DC* Output Signal | Supply Standard Voltage Passive Current Output * 4-20mA | 2 x Relays (5A) + 4-20mA 24VDC 4-20mA | (Operating Range Max. 2.8 - 24mA) Performance Accuracy 0.1% @ 25°C One Digit Accuracy According to IEC 60770 - Limit Point Adjustment | Non-Linearity | Hysteresis | Repeatability Temperatures Operating Temperatures -20 to 158°F | -29 to 70°C *Optional 2F4i-n05d47Q©uaIcolintPyroPcersos Cdounctrtolss LOtdn. line at: Valuetesters.com info@valuetesters.com3 LevelPro® -- ShoPro® SP100 Level Display | Controller Installation Instructions The unit has been designed and manufactured in a way assuring a high level of user safety and resistance to interference occurring in a typical industrial environment. In order to take full advantage of these characteristics installation of the unit must be conducted correctly and according to the local regulations. ? Read the basic safety requirements on page 2 prior to starting the installation. ? Ensure that the power supply network voltage corresponds to the nominal voltage stated on the unit's identification label. The load must correspond to the requirements listed in the technical data. ? All installation works must be conducted with a disconnected power supply. ? Protecting the power supply connections against unauthorized persons must be taken into consideration. Package Contents Please verify that all listed parts are consistent, undamaged and included in the delivery / your specified order. After removing the unit from the protective packaging, please verify that all listed parts are consistent, undamaged and included in the delivery/your specified order. Any transportation damage must be immediately reported to the carrier. Also, write down the unit serial number located on the housing and report the damage to the manufacturer. Wall Mounting 1 2 3 111.75 mm 62.5mm Ø4.4 R dSP SET F AL R1 SP100 R2 Sht To install device on the wall, pinholes should be made. The distances between holes are mentioned above. This part of the case should be mounted to a wall by screws. Loosen Box Screws & Open Display Cover 4 5 6 R dSP SET F AL R1 SP100 R2 Sht Remove Display Cover R dSP SET F AL R1 SP100 R2 Sht Mount on Wall using Screws 2F4i-n05d47Q©uaIcolintPyroPcersos Cdounctrtolss LOtdn. line at: R dSP SET F AL R1 SP100 R2 Sht R dSP SET F AL R1 SP100 R2 Sht Tighten Srews Place Display Cover and Tighten Box Screws Valuetesters.com info@valuetesters.com4 LevelPro® -- ShoPro® SP100 Level Display | Controller Pipe | Pole Clamp Installation 1 2 3 Do Not Use Tools Do Not Use Tools Open Clamp Wiring 1 R SP100 ddSSPP SSEETT F AL AL R R1 1 SP100 RR2 2 SShhtt 2 R SP100 dSP dSP SET SET F F Sht Sht AL AL R1 SP100 R2 R 1 R2 Lock Clamp on Pipe 3 R SP100 dSP dSP SET SET F F Sht Sht AL R1 SAPL100 R2 R 1 R2 Wire Clamp Open Turn Cord Grip Counter-Clockwise 4 R SP100 dSP SET F dSP SET F Sht Sht w w w ww.wi.cicoonpnropcorn.ococm o n . c o m AL AL R1 SP100 R2 R 1 R2 Power Red Tab : 120VAC wire Blue Terminals : 0VAC wire 4-20mA Output Sensor Red Tab : +mA Blue Tab : -mA Remove Cord Grip 5 R SP100 dSP dSP SET SET F F Sht Sht w w www.wi .cicoonpnropcorn.ococmo n . c o m AL R1 SAPL100 R2 R 1 R2 Insert Wire into Cord Grip 6 R SP100 dSP SET F dSP SET F Sht Sht w w w ww.wi.cicoonpnropconr.coom c o n . c o m AL R1 SP A1L 00 R2 R 1 R2 Insert Wire in theTerminals & Close Tabs Turn Cable Grip Clockwise to Tighten 2F4i-n05d47Q©uaIcolintPyroPcersos Cdounctrtolss LOtdn. line at: Valuetesters.com info@valuetesters.com5 LevelPro® -- ShoPro® SP100 Level Display | Controller Dimensions 130.00 85.25 80.00 127.00 85.25 Wiring Diagram 130.00 62.50 111.75 Power Yellow Output Yellow Input Yellow Red Blue Red Blue Red Blue 2F4i-n05d47Q©uaIcolintPyroPcersos Cdounctrtolss LOtdn. line at: Valuetesters.com info@valuetesters.com6 LevelPro® -- ShoPro® SP100 Level Display | Controller Wiring - ShoPro + 100 Series Submersible Level Sensor SP-100 ShoPro Tank Level Display Tab 2 : -mA from Sensor (Black) Tab 3 : +mA from Sensor (Red) 34 12 LP100 Junction Box Power Supply 120VAC Red Tab : +ve from Junction Box (Green) Blue Tab : -ve from Junction Box (Blue) Red Black +mA -mA 100 Series Submersible Liquid Level Sensor Wiring - ShoPro + ProScan®3 Radar Level Sensor SP-100 ShoPro Tank Level Display Power Supply 120VAC Red Tab : +ve from Junction Box (Red) Blue Tab : -ve from Junction Box (Black) Red Wire : +ve Terminal Black Wire : -ve Terminal 2F4i-n05d47Q©uaIcolintPyroPcersos Cdounctrtolss LOtdn. line at: Rotate display anti-clockwise to access wiring terminals ProScan®3 Radar Liquid Level Sensor Valuetesters.com info@valuetesters.com7 LevelPro® -- ShoPro® SP100 Level Display | Controller Display Description & Button Functions Bright Large Display Programming Push Buttons SP100 dSP SET F Alarm LED Indicator (AL) AL R1 R2 Sht Relay 1 & 2 LED Indicators (R) dSP = Display Programming Menu (Press + Hold for 3 sec.) SET = Save the Value F = [F] [] Press & Hold Back Menu for 3 SEC for Alarm Set = Changing the Values Sht = [F] Back to Main Display [ ] Changing Menu Programming 4-20mA STEPS 1 Main Menu dSP 3 Sec. 2 4mA Settings SET 3 Enter 4mA Value SET F DISPLAY Move Selection Left Sht Change Digit Value OPERATION Main Display R SP100 ddSSPP SSEETT FF FSht www.iconprocon.com www.iconprocon.com AL AL R1 R1 SP100 RR22 4mA Settings 4mA = Low Level Enter 4mA Value Factory Default = 0 4mA Empty 4 20mA Settings SET 5 Enter 20mA Value SET 20mA Settings 20mA = High Level Enter 20mA Value 20mA R SP100 ddSSPP SSEETT FF SFht www.iwcwow.incopnprroococn.oconm .com AL AL RR1 1SP100 RR2 2 6 Main Display Main Display dSPL = Low Level Value | Empty or Lowest Liquid Level | Factory Default = 0. dSPH = High Level Value | Enter Maximum Level. 2F4i-n05d47Q©uaIcolintPyroPcersos Cdounctrtolss LOtdn. line at: Valuetesters.com info@valuetesters.com8 LevelPro® -- ShoPro® SP100 Level Display | Controller Alarm Programming STEPS 1 Main Display F 3 Sec. 2 Alarm 1 Settings SET 3 Alarm 1 Value SET 4 Alarm 2 Settings SET 5 Alarm 2 Value SET 6 Hysteresis SET 7 Hysteresis Value SET 8 Main Display DISPLAY Main Display F Move Selection Left OPERATION Sht Change Digit Value Alarm 1 Settings Alarm 1 Value Enter Alarm 1 Value Alarm 2 Settings Alarm 2 Value Enter Alarm 2 Value Hysteresis Hysteresis Value Enter Hysterisis Value Main Display Alarm Mode Selection ALt No. ALt = 1 ALt = 2 ALt = 3 · CV AL1 AL1 Relay ON · CV < (AL1-HYS) AL1 Relay OFF Description · CV AL2 AL2 Relay ON · CV < (AL2-HYS) AL2 Relay OFF · CV AL1 AL1 Relay ON · CV < (AL1-HYS) AL1 Relay OFF · CV AL2 AL2 Relay ON · CV > (AL2+HYS) AL2 Relay OFF · CV AL1 AL1 Relay ON · CV > (AL1+HYS) AL1 Relay OFF · CV AL2 AL2 Relay ON · CV > (AL2+HYS) AL2 Relay OFF CV = Current Value Note: To access the Alarm Mode Selection Menu, press SET + F 3 Sec. And then press SET X 6 2F4i-n05d47Q©uaIcolintPyroPcersos Cdounctrtolss LOtdn. line at: Valuetesters.com info@valuetesters.com9 LevelPro® -- ShoPro® SP100 Level Display | Controller Reset Programming STEPS 1 Main Display SET + F 3 Sec. 2 Lock Settings SET X 2 3 Input Settings SET X 7 4 Home Screen SET + F 3 Sec. 5 Lock Settings SET X 2 6 Input Settings SET X 7 DISPLAY Main Display F Move Selection Left OPERATION Sht Change Digit Value Lock Settings Factory Default : Lk.10 Otherwise meter will enter Lockout Mode* Input Settings Int.2 will be displayed. Change Int.2 to Int.4 using or Sht button. Main Display The Value displayed will be 0.00. This value is equal to 4mA output from the sensor Lock Settings Input Settings Int.4 will be displayed. Change Int.4 to Int.2 using or Sht button. 7 Main Display SET + F 3 Sec. 8 Lock Settings SET X 3 Main Display The value displayed is equal to 20mA output from the sensor. Lock Settings 9 Decimal Point SET X 6 Decimal Point Change decimal point to 0. (dP.0) 10 Main Display Main Display Reset Completed After reset, the dSPL (4mA) and dSPH (20mA) values must be reconfigured. See "Programming 4-20mA" (Page 8) for details. 2F4i-n05d47Q©uaIcolintPyroPcersos Cdounctrtolss LOtdn. line at: Valuetesters.com info@valuetesters.com10 LevelPro® -- ShoPro® SP100 Level Display | Controller Warranty, Returns and Limitations Warranty Icon Process Controls Ltd warrants to the original purchaser of its products that such products will be free from defects in material and workmanship under normal use and service in accordance with instructions furnished by Icon Process Controls Ltd for a period of one year from the date of sale of such products. Icon Process Controls Ltd obligation under this warranty is solely and exclusively limited to the repair or replacement, at Icon Process Controls Ltd option, of the products or components, which Icon Process Controls Ltd examination determines to its satisfaction to be defective in material or workmanship within the warranty period. Icon Process Controls Ltd must be notified pursuant to the instructions below of any claim under this warranty within thirty (30) days of any claimed lack of conformity of the product. Any product repaired under this warranty will be warranted only for the remainder of the original warranty period. Any product provided as a replacement under this warranty will be warranted for the one year from the date of replacement. Returns Products cannot be returned to Icon Process Controls Ltd without prior authorization. To return a product that is thought to be defective submit a customer return (MRA) request form and follow the instructions therein. All warranty and non-warranty product returns to Icon Process Controls Ltd must be shipped prepaid and insured. Icon Process Controls Ltd will not be responsible for any products lost or damaged in shipment. Limitations This warranty does not apply to products which: 1) are beyond the warranty period or are products for which the original purchaser does not follow the warranty procedures outlined above; 2) have been subjected to electrical, mechanical or chemical damage due to improper, accidental or negligent use; 3) have been modified or altered; 4) anyone other than service personnel authorized by Icon Process Controls Ltd have attempted to repair; 5) have been involved in accidents or natural disasters; or 6) are damaged during return shipment to Icon Process Controls Ltd reserves the right to unilaterally waive this warranty and dispose of any product returned to Icon Process Controls Ltd where: 1) there is evidence of a potentially hazardous material present with the product; or 2) the product has remained unclaimed at Icon Process Controls Ltd for more than 30 days after Icon Process Controls Ltd has dutifully requested disposition. This warranty contains the sole express warranty made by Icon Process Controls Ltd in connection with its products. ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY DISCLAIMED. The remedies of repair or replacement as stated above are the exclusive remedies for the breach of this warranty. IN NO EVENT SHALL Icon Process Controls Ltd BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING PERSONAL OR REAL PROPERTY OR FOR INJURY TO ANY PERSON. THIS WARRANTY CONSTITUTES THE FINAL, COMPLETE AND EXCLUSIVE STATEMENT OF WARRANTY TERMS AND NO PERSON IS AUTHORIZED TO MAKE ANY OTHER WARRANTIES OR REPRESENTATIONS ON BEHALF OF Icon Process Controls Ltd. This warranty will be interpreted pursuant to the laws of the province of Ontario, Canada. If any portion of this warranty is held to be invalid or unenforceable for any reason, such finding will not invalidate any other provision of this warranty. by 2F4i-n05d47Q©uaIcolintPyroPcersos Cdounctrtolss LOtdn. line at: Valuetesters.com info@valuetesters.com11