Twin-Line Concentrate Doorway Foam Unit For 2-Part Products
DS-WC-2P-TL
The Good Stuff
-
Consistent dilution rates
Regardless of water pressure changes, this unit reliably dilutes chemistry.
-
Nozzle assembly
Supports up to 3 twin-line nozzle assemblies with a total of 100 ft (30.5 m) total distance between the control box and nozzle(s).
-
On schedule chemical delivery
Easy to use repeat cycle digital timer (adjustable via traffic flow) with set delays to ensure coverage.
Features
- Draws from two concentrated products simultaneously.
- Ideal for 2-part products that need to be mixed on the fly.
- Dilutes at ratios of 7:1 to 125:1 (water:chemical) for each product.
- Dilution rates can be independently controlled for each product.
- Repeat cycle digital timer.
- Quick-change pump.
- Supports up to 3 twin-line stainless steel nozzle assemblies.
- Up to 100 ft. (30.5 m) total distance between control box and nozzle(s) (Note: distance does not need to be evenly distributed).
- Consistent, reliable dilution rates, regardless of changes in water pressure.
Specifications
- Power type: compressed air and electricity
- Chemical pickup type: draws from concentrated product
- Dilution ratio range (water:chemical): 7:1 to 125:1 (Note: dilution rate can be set independently for each product)
- Number of products: two products, simultaneously
- Suction line length/diameter: two 8 ft. (2.4 m) clear hose with 1/4 in. (6.4 mm) inside diameter
- Flow rate: 2 gal/min (7.6 l/min)
- Pump seals: Santoprene, Viton, or Kalrez
- Timer operation type: repeat cycle
- Coverage area: ONE NOZZLE: up to 9x5 ft. (2.7x1.5 m); TWO NOZZLES: up to 8x4 ft. (2.4x1.2 m) each; THREE NOZZLES: up to 6x3 ft. (1.8x0.9 m) each
- Nozzle type: twin-line stainless steel nozzle assembly
- Number of nozzles: one control box can support up to three nozzle assemblies
- Distance from nozzles to control box: the combined distance between control box and nozzle(s) must equal 100 ft. (30.5 m) or less
- Tubing/fitting sizes: designed for use with 1/2 in. (12.7 mm) outside diameter tubing between control box and nozzle(s)
Industries
- Institutional
- Food and Beverage
- Manufacturing
Requirements
- Compressed air requirements: 40-80 psi (2.8-5.5 bar) with 5-10 CFM (141.6-283.2 l/min)
- Water requirements: 10-100 psi (0.7-6.9 bar); backflow prevention is required
- Liquid temperature range: 40-100°F (4.4-37.8°C)
- Electrical requirements: 100-240 VAC, 50-60Hz, 1A (GFCI protected outlet)
- Operating voltage: 24 VDC
- Chemical compatibility: chemical products used with this equipment must be formulated for this type of application and compatible with unit materials and pump seals. For more information on chemical compatibility, consult the manufacturer or SDS for your product or contact customer service department.
How to Buy
Contact FOAMit at 800 567 5420 or sales@foamit.com.
A visual representation shows a grey, rectangular control box unit with hoses and nozzles attached, mounted on a wall or surface.
Related Documents
![]() |
DS-WC-2P-TL Twin-Line Concentrate Doorway Foam Unit Service Manual Comprehensive service manual for the FOAMit DS-WC-2P-TL Twin-Line Concentrate Doorway Foam Unit. Covers safety, maintenance, troubleshooting, and detailed assembly instructions for control box and nozzle components. |
![]() |
Single-Line Concentrate Doorway Foam Unit DS-WC | FOAMit Detailed specifications and features of the FOAMit Single-Line Concentrate Doorway Foam Unit (DS-WC), including dilution ratios, coverage, and operational requirements. |
![]() |
Twin-Line Concentrate Doorway Foam Unit Service Manual Service manual for the FOAMit Twin-Line Concentrate Doorway Foam Unit (DS-WC-TL), providing comprehensive safety instructions, detailed maintenance procedures, effective troubleshooting guides, and assembly breakdowns for control boxes and nozzle systems. |
![]() |
Twin-Line Pre-mix Doorway Foam Unit Service Manual DS-WL-TL Comprehensive service manual for the FOAMit DS-WL-TL Twin-Line Pre-mix Doorway Foam Unit, detailing safety precautions, maintenance procedures, troubleshooting steps, and component assembly information. |
![]() |
Twin Line Central Doorway Foam Station DS-WSTN-TL | FOAMit Discover the FOAMit Twin Line Central Doorway Foam Station (DS-WSTN-TL). This system offers secure chemical location, no refills, and on-schedule chemical delivery for efficient foam application. Learn about its features, specifications, and requirements for food and beverage and manufacturing industries. |
![]() |
FOAMit DS-WC Single-Line Concentrate Doorway Foam Unit Service Manual Comprehensive service manual for the FOAMit DS-WC Single-Line Concentrate Doorway Foam Unit, covering safety, maintenance, troubleshooting, and detailed parts identification for various assemblies. |
![]() |
FOAMit DS-WL Single-Line Pre-mix Doorway Foam Unit Service Manual Comprehensive service manual for the FOAMit DS-WL Single-Line Pre-mix Doorway Foam Unit, detailing safety procedures, maintenance, troubleshooting, and assembly instructions for various components. |
![]() |
Single Line Central Doorway Foam Station Operation Manual DS-STN | FOAMit Operation manual for the FOAMit DS-STN Single Line Central Doorway Foam Station. Provides instructions on installation, operation, safety, and maintenance for this chemical application equipment. |