Safety Precautions

Please read all instructions carefully before using the dehumidifier. Improper use can lead to death, injury, or property damage.

General Safety Instructions

  1. Read all instructions carefully before using. Hazards that may cause death, injury or property damages from misuse.
  2. Be sure of correct voltage is used and plug is well plugged in socket.
  3. Remove plug from socket for cleaning maintenance or storage.
  4. To avoid danger, please do not cover inlet/outlet with cloth or curtain. Poor ventilation may cause fire.
  5. Please do not operate dehumidifier in a closed or narrow space. If used in a closet, keep the door open and clothing at least 30 cm away from air inlets/outlets to avoid obstruction. A closed space may cause temperature rise and damage the machine.
  6. Please do not insert fingers, nails, or metal rods into the unit.
  7. Do not stand on or lean against the unit. This may cause it to fall over, resulting in personal injury.
  8. Before moving the unit, please empty water and remove the plug from the socket.
  9. To avoid short circuit or leakage, do not spray water on the unit.
  10. Never immerse the body, power cord, or plug in water or let them get wet to avoid functional damage or electric shock.
  11. Do not spray solvent or flammable liquid.
  12. Do not lay down the unit, as this may damage it and cause noise.
  13. If the unit is out of order, do not attempt to disassemble it.
  14. Avoid leaving an operating dehumidifier unattended.
  15. This appliance can be used by children aged 8 years and above, and persons with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, if they have been given supervision or instruction concerning safe use and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

Warning Symbols and Meanings

Ignoring symbols and incorrect operation can result in harm or damage.

The product's designed useful life is ten years. If it exceeds this period, parts may deteriorate, leading to dust accumulation, lack of maintenance, and potential fire hazards.

Specific Prohibitions and Actions

Specific Warnings:

Parts Description

The dehumidifier consists of the following parts:

Front View:

Rear View:

Control Panel:

The control panel features various buttons and indicators for operating the unit:

Operation Instructions

Follow these steps to operate the dehumidifier:

  1. Power On: Ensure the correct voltage is used and plug the unit into a socket. The unit automatically detects ambient humidity. If humidity is above RH75%, the LCD backlight will turn deep blue.
  2. Press the Power ON/OFF button. The unit starts and operates in ECO mode by default. When room humidity is over RH50%, the compressor will turn on in 3 minutes (or immediately if plugged in for over 3 minutes).
  3. Adjust Dehumidification Mode: Press the Mode button to cycle through: ECO (energy saving, 50-60% RH), Low Humidity Dry (under 50% RH), Comfort (suitable level for human body), Continuous Dry (runs until tank is full or turned off).
  4. Adjust Dry Clothes Mode: Press the Dry Clothes button to select: Standard (medium fan speed), Quiet (low fan speed for sleeping), Speed (high fan speed for quick drying). The unit operates for a maximum of 8 hours in this mode.
  5. Humidity Selection: Press the Humidity Selection button to set the desired humidity level (40%-70%). The display shows the set level for 4 seconds, then returns to the current humidity.
  6. Air Clean Mode: Select Air Clean mode to purify the air. The compressor is off, and you can choose low or high air volume.
  7. Louver Setting: Press the Louver button to adjust the air outlet direction (Down, Up, Wide swing, or Swinging stops). Do not manually move the louver while it is swinging.
  8. Timer Setting: Press the Timer button to set the auto-shutdown time (1-12 hours). The remaining time will be displayed.
  9. Error Indicators: If the unit is tipped over, the water tank is full, or not in place, the Humidity Indicator will flash and an alarm will sound. The display may show 'Er'. To reset, disconnect power, place the unit upright, and reconnect power. The compressor will start after a 10-minute delay.
  10. Key Lock: Press and hold the Key Lock button for 3 seconds to activate. All other buttons become inactive. Press and hold again for 3 seconds to deactivate.
  11. Air Purifying Function: Press the Ion button to turn the negative ion generator on/off for air purification.
  12. Operating Temperature Range: The unit operates optimally between 5°C and 35°C.

Important Features

  1. Easy to carry: Features handles and casters for convenient movement.
  2. Timer setting: Allows for automatic shut-off from 1 to 12 hours.
  3. LCD display: Shows function and humidity settings clearly.
  4. Auto louver: Provides three angles for air outlet direction control.
  5. ECO mode: Automatically adjusts humidity to keep it between 50-60% for energy efficiency.
  6. Large water tank: 6L capacity with automatic shut-off at 5L.
  7. Easy drying: Efficiently dries clothes and fabrics, even on rainy days.
  8. Moisture removal: Helps dry wet ceilings and walls.
  9. Odor and mold prevention: Removes moisture from rugs, carpets, cabinets, and helps prevent mold on fabrics and leather goods.
  10. Suitable for sensitive items: Can be used to protect pianos and similar musical instruments from humidity.

Water Tank Installation and Drainage

Water Tank Operation

When the water tank is full (approximately 5L), the 'Water Tank Full' indicator will light up and flash, and the unit will stop operation. Empty the tank to resume operation.

  1. Remove water tank: Insert fingers into the lower groove of the tank and gently pull it out.
  2. Empty water tank: Hold the tank handle, tilt it to the drain hole, and empty the water. Ensure the polyfoam floater is in place; if lost, the unit may not operate correctly or may leak. Replace the tank handle.
  3. Install water tank: Place the water tank back into the unit until it clicks into position. The 'Water Tank Full' indicator will turn off, and the unit will resume operation.
  4. Do not remove float: Never remove or discard the polyfoam floater from the water tank, as this will cause the auto-stop function to fail.

Notice:

Continuous Drainage (Hose Drain Installation)

For continuous drainage, connect a hose:

  1. Use a tool to open the continuous drain hole on the back of the unit.
  2. Insert a hose (13-15mm inner diameter, self-purchase) through the drain hole.
  3. Connect the L-shaped drain port to the hose.
  4. Reinstall the water tank in its proper position. The dehumidifier will not function if the tank is not installed correctly.

Caution: Do not drain water continuously if there is a possibility of leaving the unit unattended for long periods.

Maintenance

Regular maintenance ensures the longevity and efficiency of your dehumidifier. Always disconnect the unit from the power socket before cleaning.

Cleaning of Filter:

A clogged filter reduces dehumidification efficiency and can cause failure. Clean the filter every 2 weeks.

  1. Remove the air inlet cover.
  2. Remove the prefilter. Clean dust using a vacuum cleaner (place dirty side up) or wash under tap water (place dirty side down). Dry the filter completely before reinstalling.
  3. Reinstall the prefilter in its original position. Ensure it is completely dry to prevent water from entering the unit.

Notice:

Cleaning the Main Unit:

  1. Wipe the unit with a soft cloth moistened with warm water (below 40°C) or mild detergent.
  2. Clean with a neutral detergent and then wipe with a damp cloth.
  3. Clean the control panel with a dry cloth to avoid short circuits.
  4. Do not use solvents, alcohol, or thinners, as they can damage the surface.
  5. Avoid using volatile chemicals, gasoline, or harsh detergents.

Storage:

  1. Completely empty and dry the water tank.
  2. Turn off the unit, unplug it, and tidy the power cord.
  3. Clean the air filter.
  4. Cover the unit with a plastic bag and store it in a well-ventilated area away from direct sunlight.

Photocatalytic Filter Cleaning and Replacement

The photocatalytic filter helps purify the air. Its lifespan is about 5 years.

  1. Remove the photocatalytic filter from its plastic bag.
  2. Remove the air inlet cover and insert the filter into the fixed hook completely.
  3. Using this filter may decrease dehumidifying capacity by 3-5%.
  4. Before cleaning, stop the unit and turn off the power.
  5. Cleaning: Clean the filter every 6 months. Remove the filter, wash it under tap water, and dry it in sunlight for about 6 hours. Do not wash with soap or squeeze to avoid damage.

If the filter becomes damaged, it should be replaced. Filter life depends on usage and environmental conditions. It is a consumable item and should be replaced as scheduled. Contact your nearest service center.

Specifications

Model No. RPD-YS27GU
Rated Voltage/Frequency 220-240V~ 50Hz
Rated Capacity(L/Day) 14.9L (26.7°C RH60%)
27L (30°C RH80%)
Rated Power 265W
Rated current 1.25A
Refrigerant & Amount R134a,350g
Tank Capacity 6L (5L Shut off)
Net Weight 15.8 kg
Dimension(mm) 600H x 370W x 263D(mm)

Note:

Special Avowal:

  1. The information provided has been verified. The company reserves the right to interpret any printing errors or misunderstandings.
  2. Technical improvements may lead to updated manuals without prior notice. Product appearance and color are subject to the actual appliance.
  3. An electronic copy of the user manual can be emailed upon request. Contact Shun Hing Electric Works and Engineering Co., Ltd. at 28612767.

Troubleshooting and Emergency Handling

Before requesting repairs, check the following points:

Trouble Problem Cause
Unit is not operating
  • Water tank not placed correctly
  • Water tank is full
  • Power cord is unplugged
  • Fuse switch issue
  • Power failure
Poor performance
  • Air filter obstructed by dirt or dust
  • Object obstructing the rear discharge outlet
  • Humidity or temperature may be too low
Water leakage
  • Drain tube is clogged
  • Water tank installed improperly
  • Damaged water tank
No humidity removal
  • Operated area is too large
  • Windows or doors are open
  • Something producing lots of humidity in the room
Unit makes a noise
  • Unit is placed improperly
  • The floor is not flat
No wind flow out
  • Air filter obstructed by dirt or dust

For Emergency:

Contact Information

Shun Hing Electric Works and Engineering Co., Ltd.

Office: 9/F Peninsula Centre, 67 Mody Road, Tsimshatsui East, Kowloon, Hong Kong

Tel: (852) 2861 2767 | Fax: (852) 2865 6706

Website: http://www.rasonic.com | E-mail: shew@shunhinggroup.com

Shun Hing Electric Service Centre Ltd.

11th Floor, Shun Hing Centre, 2 Shing Yiu Street, Kwai Chung, New Territories, Hong Kong

Tel: (852) 2406 5666 | Fax: (852) 2408 0316

Consumables/Accessories Sales Hotline: (852) 2406 5666

Website: www.shesc.com

Customer Service Centres:

Hong Kong: 1st Floor, Shun Hing Centre, 2 Shing Yiu Street, Kwai Chung, New Territories, Hong Kong

Tel: (852) 2406 5439 | Fax: (852) 2408 1389

Macau: Avenida de Venceslau de Morais, No. 193~199, 5 andar - I, Edf. Industrial Nam Leng, Macau

Tel: (853) 2836 2928 | Fax: (853) 2833 6405

For the latest information, please visit www.shesc.com or call our hotline.

Models: RPD-YS27GU Compressor Type Dehumidifier, RPD-YS27GU, Compressor Type Dehumidifier, Type Dehumidifier, Dehumidifier

File Info : application/pdf, 35 Pages, 11.03MB

PDF preview unavailable. Download the PDF instead.

rpd-ys27gu user manual

References

Adobe PDF library 15.00

Related Documents

Preview Rasonic RPD-YL13U Dehumidifier: User Manual and Operating Guide
Comprehensive user manual for the Rasonic RPD-YL13U Dehumidifier, covering safety precautions, operating instructions, maintenance, troubleshooting, and product specifications. Learn how to use and care for your Rasonic dehumidifier.
Preview Rasonic RDW-J6W / RDW-J6P Table Top Dishwasher Operation Manual
Comprehensive operation manual for the Rasonic RDW-J6W and RDW-J6P table top dishwashers, covering installation, usage, maintenance, troubleshooting, and safety precautions.
Preview Rasonic R410A Window Type Air Conditioner User Manual - Models RC-X7KM, RC-X9KM
This user manual provides comprehensive instructions for operating, installing, and maintaining the Rasonic R410A Window Type Air Conditioner, models RC-X7KM and RC-X9KM. It includes safety precautions, parts identification, operating modes, troubleshooting tips, and specifications.
Preview Rasonic EL30H/EL35H Electric Fan User Manual and Operating Instructions
Comprehensive guide to operating, assembling, maintaining, and troubleshooting your Rasonic EL30H and EL35H electric fan. Includes safety precautions and specifications.
Preview Rasonic RDW-ZW39 Table Top Dishwasher: Operation Manual
This comprehensive operation manual provides detailed instructions for the Rasonic RDW-ZW39 Table Top Dishwasher, covering installation, safety precautions, operation, cleaning, maintenance, troubleshooting, and after-sales service.
Preview Rasonic Air Fryer RAF-B281 Operation Manual
Operation manual for the Rasonic Air Fryer RAF-B281, providing safety precautions, product specifications, usage instructions, and troubleshooting tips.
Preview Rasonic RW-AH813 Washing Machine User Manual
Comprehensive user manual for the Rasonic RW-AH813 washing machine, covering safety instructions, installation, operation, maintenance, troubleshooting, and technical specifications.
Preview Rasonic RSG-R80G Built-in Steam Grill Oven: Operation Manual
This operation manual provides comprehensive instructions for the Rasonic RSG-R80G Built-in Steam Grill Oven, covering safety precautions, installation, cleaning, operation, troubleshooting, and after-sales service.