Safety Precautions
Please read all instructions carefully before using the dehumidifier. Improper use can lead to death, injury, or property damage.
General Safety Instructions
- Read all instructions carefully before using. Hazards that may cause death, injury or property damages from misuse.
- Be sure of correct voltage is used and plug is well plugged in socket.
- Remove plug from socket for cleaning maintenance or storage.
- To avoid danger, please do not cover inlet/outlet with cloth or curtain. Poor ventilation may cause fire.
- Please do not operate dehumidifier in a closed or narrow space. If used in a closet, keep the door open and clothing at least 30 cm away from air inlets/outlets to avoid obstruction. A closed space may cause temperature rise and damage the machine.
- Please do not insert fingers, nails, or metal rods into the unit.
- Do not stand on or lean against the unit. This may cause it to fall over, resulting in personal injury.
- Before moving the unit, please empty water and remove the plug from the socket.
- To avoid short circuit or leakage, do not spray water on the unit.
- Never immerse the body, power cord, or plug in water or let them get wet to avoid functional damage or electric shock.
- Do not spray solvent or flammable liquid.
- Do not lay down the unit, as this may damage it and cause noise.
- If the unit is out of order, do not attempt to disassemble it.
- Avoid leaving an operating dehumidifier unattended.
- This appliance can be used by children aged 8 years and above, and persons with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, if they have been given supervision or instruction concerning safe use and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Warning Symbols and Meanings
Ignoring symbols and incorrect operation can result in harm or damage.
- WARNING: Improper handling may lead to serious injury or even death.
- CAUTION: Improper handling may lead to injury or property damage.
The product's designed useful life is ten years. If it exceeds this period, parts may deteriorate, leading to dust accumulation, lack of maintenance, and potential fire hazards.
Specific Prohibitions and Actions
- Never do: Do not cover air inlets/outlets.
- Be sure to follow instructions: Always adhere to the manual's guidance.
- Do not wet: Avoid exposing the unit to water.
- Keep away from flames: Do not use near open flames or heat sources.
- Caution or Notice: Pay attention to these advisories.
- Disconnect the power plug: Always unplug before cleaning or maintenance.
- Do not handle with wet hands: Avoid touching plugs or controls with wet hands.
- Prohibit disassembling: Do not attempt to repair the unit yourself.
Specific Warnings:
- Do not modify or disassemble the unit: Improper handling may lead to fire, short circuits, electric shocks, or injury. Contact Shun Hing Electric Service Centre Limited for repairs.
- Disconnect power cord before cleaning, maintenance, or moving: Prevents electric shock.
- Do not pull out the power plug with wet hands: May cause electric shocks.
- Do not use if power cord or plug is damaged or loose: Can lead to fire or electric shock. Periodically clean dust from the plug.
- Insert power plug completely: Incomplete connections can cause electric shock or fire due to overheating.
- Do not damage, bend, pull, twist, or place heavy objects on the power cord: Using a damaged cord can cause fire or electric shock.
- Use only a 220V-240V power supply: Other voltages may cause fire or electric shock.
- Accumulation of dust and foreign objects: May cause insulation failure and lead to fire.
- Do not use on an uneven floor: Can cause instability and potential damage.
- Do not unplug roughly: Pulling the cord can cause fire, short circuit, or electric shock.
- Do not use near flammable gas: Flammable gas can cause fire.
- Do not spray volatile substances (gasoline, solvent, insecticide): May cause fire or electric shock.
- Do not use where airborne oil is present: Airborne oil can lead to cracking or ignition.
- Before long periods of disuse, disconnect the power plug: Degraded insulation can lead to electric shock or fire. The dehumidifier must not be left unattended while connected to the supply cord.
- Do not use where water may splash onto the unit: Avoid product damage or electric shock.
- Do not use an extension power cord: May result in overheating and fire.
- Do not use a damaged power cord or plug: May cause electric shock, short-circuit, or fire.
- Do not trample on the cord: Can cause damage. If the cord is damaged, it must be replaced by a qualified person.
Parts Description
The dehumidifier consists of the following parts:
Front View:
- Louver: Controls air outlet direction.
- Air outlet: Where dehumidified air is expelled.
- Front plate: The front casing of the unit.
- Outfall Tank Cover: Covers the water tank.
- Water tank: Collects condensed water.
- Handles (left and right): For carrying the unit.
Rear View:
- Air inlet: Where room air is drawn in.
- Handles (left and right): For carrying the unit.
- Polyfoam floater: Located inside the water tank, indicates water level.
- Cord holder: For storing the power cord.
- Tank handle: For carrying the water tank.
- Power cord: Connects the unit to the power supply.
- Drain hole: For continuous drainage (optional).
- Power plug: Connects to the electrical outlet.
Control Panel:
The control panel features various buttons and indicators for operating the unit:
- Key Lock (按鍵鎖): Locks/unlocks control buttons.
- Ion (離子清淨): Activates negative ion purification.
- Timer (定時): Sets automatic shut-off time (1-12 hours).
- Louver Setting (風向調節): Adjusts the direction of the air outlet.
- Humidity Indicator (濕度顯示): Shows current and set humidity levels.
- Mode Indicators (運轉模式): ECO, Low Humidity Dry, Comfort, Continuous Dry.
- Dry Clothes Indicators (乾衣模式): Standard, Quiet, Speed.
- Power ON/OFF (開關/電源): Turns the unit on and off.
- Indicators: Water Tank Full (滿水), Defrost (除霜), Anti-mold (防霉).
- LCD Display: Shows current humidity, set humidity, timer settings, and error codes.
Operation Instructions
Follow these steps to operate the dehumidifier:
- Power On: Ensure the correct voltage is used and plug the unit into a socket. The unit automatically detects ambient humidity. If humidity is above RH75%, the LCD backlight will turn deep blue.
- Press the Power ON/OFF button. The unit starts and operates in ECO mode by default. When room humidity is over RH50%, the compressor will turn on in 3 minutes (or immediately if plugged in for over 3 minutes).
- Adjust Dehumidification Mode: Press the Mode button to cycle through: ECO (energy saving, 50-60% RH), Low Humidity Dry (under 50% RH), Comfort (suitable level for human body), Continuous Dry (runs until tank is full or turned off).
- Adjust Dry Clothes Mode: Press the Dry Clothes button to select: Standard (medium fan speed), Quiet (low fan speed for sleeping), Speed (high fan speed for quick drying). The unit operates for a maximum of 8 hours in this mode.
- Humidity Selection: Press the Humidity Selection button to set the desired humidity level (40%-70%). The display shows the set level for 4 seconds, then returns to the current humidity.
- Air Clean Mode: Select Air Clean mode to purify the air. The compressor is off, and you can choose low or high air volume.
- Louver Setting: Press the Louver button to adjust the air outlet direction (Down, Up, Wide swing, or Swinging stops). Do not manually move the louver while it is swinging.
- Timer Setting: Press the Timer button to set the auto-shutdown time (1-12 hours). The remaining time will be displayed.
- Error Indicators: If the unit is tipped over, the water tank is full, or not in place, the Humidity Indicator will flash and an alarm will sound. The display may show 'Er'. To reset, disconnect power, place the unit upright, and reconnect power. The compressor will start after a 10-minute delay.
- Key Lock: Press and hold the Key Lock button for 3 seconds to activate. All other buttons become inactive. Press and hold again for 3 seconds to deactivate.
- Air Purifying Function: Press the Ion button to turn the negative ion generator on/off for air purification.
- Operating Temperature Range: The unit operates optimally between 5°C and 35°C.
Important Features
- Easy to carry: Features handles and casters for convenient movement.
- Timer setting: Allows for automatic shut-off from 1 to 12 hours.
- LCD display: Shows function and humidity settings clearly.
- Auto louver: Provides three angles for air outlet direction control.
- ECO mode: Automatically adjusts humidity to keep it between 50-60% for energy efficiency.
- Large water tank: 6L capacity with automatic shut-off at 5L.
- Easy drying: Efficiently dries clothes and fabrics, even on rainy days.
- Moisture removal: Helps dry wet ceilings and walls.
- Odor and mold prevention: Removes moisture from rugs, carpets, cabinets, and helps prevent mold on fabrics and leather goods.
- Suitable for sensitive items: Can be used to protect pianos and similar musical instruments from humidity.
Water Tank Installation and Drainage
Water Tank Operation
When the water tank is full (approximately 5L), the 'Water Tank Full' indicator will light up and flash, and the unit will stop operation. Empty the tank to resume operation.
- Remove water tank: Insert fingers into the lower groove of the tank and gently pull it out.
- Empty water tank: Hold the tank handle, tilt it to the drain hole, and empty the water. Ensure the polyfoam floater is in place; if lost, the unit may not operate correctly or may leak. Replace the tank handle.
- Install water tank: Place the water tank back into the unit until it clicks into position. The 'Water Tank Full' indicator will turn off, and the unit will resume operation.
- Do not remove float: Never remove or discard the polyfoam floater from the water tank, as this will cause the auto-stop function to fail.
Notice:
- Wait a few minutes after the 'Water Tank Full' indicator lights up before removing the tank to allow residual water to drain.
- Turn off the unit and empty the water tank before moving it to prevent spills.
- In low temperatures, dehumidified water may freeze on the evaporator, preventing it from dripping into the tank. This is not a malfunction.
- Keep the water drain hole clear to prevent blockages.
- The polyfoam floater contains a magnet that signals the water level. Do not remove it, or the unit will not operate correctly.
Continuous Drainage (Hose Drain Installation)
For continuous drainage, connect a hose:
- Use a tool to open the continuous drain hole on the back of the unit.
- Insert a hose (13-15mm inner diameter, self-purchase) through the drain hole.
- Connect the L-shaped drain port to the hose.
- Reinstall the water tank in its proper position. The dehumidifier will not function if the tank is not installed correctly.
Caution: Do not drain water continuously if there is a possibility of leaving the unit unattended for long periods.
Maintenance
Regular maintenance ensures the longevity and efficiency of your dehumidifier. Always disconnect the unit from the power socket before cleaning.
Cleaning of Filter:
A clogged filter reduces dehumidification efficiency and can cause failure. Clean the filter every 2 weeks.
- Remove the air inlet cover.
- Remove the prefilter. Clean dust using a vacuum cleaner (place dirty side up) or wash under tap water (place dirty side down). Dry the filter completely before reinstalling.
- Reinstall the prefilter in its original position. Ensure it is completely dry to prevent water from entering the unit.
Notice:
- Do not use water above 40°C or expose the filter to direct sunlight, as this may deform it.
- Ensure the filter is properly reinstalled to prevent dust from entering the unit.
Cleaning the Main Unit:
- Wipe the unit with a soft cloth moistened with warm water (below 40°C) or mild detergent.
- Clean with a neutral detergent and then wipe with a damp cloth.
- Clean the control panel with a dry cloth to avoid short circuits.
- Do not use solvents, alcohol, or thinners, as they can damage the surface.
- Avoid using volatile chemicals, gasoline, or harsh detergents.
Storage:
- Completely empty and dry the water tank.
- Turn off the unit, unplug it, and tidy the power cord.
- Clean the air filter.
- Cover the unit with a plastic bag and store it in a well-ventilated area away from direct sunlight.
Photocatalytic Filter Cleaning and Replacement
The photocatalytic filter helps purify the air. Its lifespan is about 5 years.
- Remove the photocatalytic filter from its plastic bag.
- Remove the air inlet cover and insert the filter into the fixed hook completely.
- Using this filter may decrease dehumidifying capacity by 3-5%.
- Before cleaning, stop the unit and turn off the power.
- Cleaning: Clean the filter every 6 months. Remove the filter, wash it under tap water, and dry it in sunlight for about 6 hours. Do not wash with soap or squeeze to avoid damage.
If the filter becomes damaged, it should be replaced. Filter life depends on usage and environmental conditions. It is a consumable item and should be replaced as scheduled. Contact your nearest service center.
Specifications
Model No. | RPD-YS27GU |
---|---|
Rated Voltage/Frequency | 220-240V~ 50Hz |
Rated Capacity(L/Day) | 14.9L (26.7°C RH60%) 27L (30°C RH80%) |
Rated Power | 265W |
Rated current | 1.25A |
Refrigerant & Amount | R134a,350g |
Tank Capacity | 6L (5L Shut off) |
Net Weight | 15.8 kg |
Dimension(mm) | 600H x 370W x 263D(mm) |
Note:
- Dehumidify capacity is subject to room temperature and humidity.
- If the power cord is damaged, it must be repaired by Shun Hing Electric Service Centre Co., Ltd. to avoid danger.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless supervised by a responsible person. Children should be supervised to ensure they do not play with the appliance. Cleaning and user maintenance shall not be performed by children without supervision.
- The guarantee period is one year from the date of purchase. Free repair service is available for damage under proper use. Present the official invoice for repair service. For inquiries, contact Shun Hing Electric Service Centre Limited hotline at 2406 5666.
Special Avowal:
- The information provided has been verified. The company reserves the right to interpret any printing errors or misunderstandings.
- Technical improvements may lead to updated manuals without prior notice. Product appearance and color are subject to the actual appliance.
- An electronic copy of the user manual can be emailed upon request. Contact Shun Hing Electric Works and Engineering Co., Ltd. at 28612767.
Troubleshooting and Emergency Handling
Before requesting repairs, check the following points:
Trouble | Problem Cause |
---|---|
Unit is not operating |
|
Poor performance |
|
Water leakage |
|
No humidity removal |
|
Unit makes a noise |
|
No wind flow out |
|
For Emergency:
- If any abnormalities occur, turn off the unit and disconnect the power cord.
- If the problem cannot be resolved, contact Shun Hing Electric Service Centre Limited for check and repair.
Contact Information
Shun Hing Electric Works and Engineering Co., Ltd.
Office: 9/F Peninsula Centre, 67 Mody Road, Tsimshatsui East, Kowloon, Hong Kong
Tel: (852) 2861 2767 | Fax: (852) 2865 6706
Website: http://www.rasonic.com | E-mail: shew@shunhinggroup.com
Shun Hing Electric Service Centre Ltd.
11th Floor, Shun Hing Centre, 2 Shing Yiu Street, Kwai Chung, New Territories, Hong Kong
Tel: (852) 2406 5666 | Fax: (852) 2408 0316
Consumables/Accessories Sales Hotline: (852) 2406 5666
Website: www.shesc.com
Customer Service Centres:
Hong Kong: 1st Floor, Shun Hing Centre, 2 Shing Yiu Street, Kwai Chung, New Territories, Hong Kong
Tel: (852) 2406 5439 | Fax: (852) 2408 1389
Macau: Avenida de Venceslau de Morais, No. 193~199, 5 andar - I, Edf. Industrial Nam Leng, Macau
Tel: (853) 2836 2928 | Fax: (853) 2833 6405
For the latest information, please visit www.shesc.com or call our hotline.