Danfoss EM-PMI375-T800-690V Electric Machine Data Sheet

Features

Generator Specific Features

Motor Specific Features

General

The machine is developed especially for demanding applications. It is smaller, lighter and more efficient than conventional products on the market.

Typical Applications

Specifications

General Electrical Properties

PropertyValue
Nominal voltage (line-to-line)690 VAC
Nominal efficiency96%
Pole pair number6
Power supplyInverter fed
Minimum inverter switching frequency4 kHz
Maximum phase-to-phase peak-to-peak voltage without du/dt2 kV
Maximum voltage rise time without du/dt8 kV/μs

Basic Information

PropertyValue
Machine typeSynchronous reluctance assisted permanent magnet
Frame materialAluminum
Mounting directionCan be used in all directions, see user guide for details. Greased for life bearings required.
Mounting (IEC 60034-7)IM 3009-B5 (flange horizontal), IM 3019-V1 (flange and D-end down)
Standard flange D-end (SAE J617)SAE 3 transmission housing
Standard axle spline D-endDIN5480 W50x2x24x8f
Standard flange N-end (SAE J617)SAE 4 flywheel housing
Standard rotation directionClockwise (both directions possible)
Bearing typeStandard: 6211-2RS1/C3WT
+BHS option: 6211/C3 (with LGHP2 grease)
+BIN option: D-end: 6211-2RS1/C3WT, N-end: 6211-2RS1/HC5C3WT
+BIA option: 6211-2RS1/HC5C3WT
+BHS+BIN options: D-end: 6211/C3 (with LGHP2 grease), N-end: 6211/HC5C3WT (with LGHP2 grease)
+BHS+BIA options: 6211/HC5C3 (with LGHP2 grease)
Protection classIP65 (IP67 available as option)
Duty type (IEC 60034-1)S1/S9
Machine coatingDark grey RAL7024
AltitudeUp to 3000 m, see Picture 2

Mechanical

PropertyValue
Total weight210 kg (no options)
Moment of inertia0.63 kgm²
Torsional stiffness of shaft drive end4*10^5 Nm/rad (from middle of the D-end spline to rotor air gap)
Rotating mass70.2 kg

Dimensions

PropertyValue
Length (frame)428 mm
Diameter (frame)450 mm

Cooling

PropertyValue
Cooling liquidPlain water with appropriate corrosive inhibitor (max. 50% corrosive inhibitor)
Cooling liquid corrosive inhibitor typeEthylene glycol (Glysantin G48 recommended)
Cooling method (IEC 60034-6)IC 71 W
Minimum cooling liquid flow20 l/min
Coolant circuit capacity1.9 l
Maximum operating pressure3 bar
Pressure loss0.4 bar with 20 l/min (+25°C coolant)
Nominal cooling liquid temperature+65°C, +40°C with +CL option
Minimum cooling liquid temperature-20°C
Maximum cooling liquid temperature+65°C

Temperature Rating

PropertyValue
Insulation class (IEC 60034-1)H (+180°C)
Temperature rise (IEC 60034-1)+85°C (F)
Maximum winding temperature+150°C
Nominal ambient temperature+65°C / +45°C with +CL option
Min. ambient temperature-40°C

Vibration & Shock Tolerance

Mechanical Vibration

Value5.9 GRMS
StandardISO 16750-3:2003 Test VII - Commercial vehicle, sprung masses – Table 12
NotesTest duration 8h axis (two axes tested; radial and axial)
Total spectral acceleration5.91 GRMS
Test done withEM-PMI375-T800 (with flange mounting)

Mechanical Shock

Value50 G
StandardISO 16750-3:2003 4.2.2 Test for devices on rigid points on the body and on the frame
Notes-acceleration: 500 m/s²; -duration: 6 ms; -number of shocks: 10 per test direction
Test done withEM-PMI375-T800 (with flange mounting)

Connections

ConnectionDescription
Coolant connection2 x G3/4 bore (see dimension drawing for details)
Cable directionStandard cable direction towards D-end
HV cables3 x 70 mm² max. (SINGLE winding model)
2 x 3 x 70 mm² max. (DUAL winding model)
HV cable glandsPflitsch blueglobe TRI bg 225ms tri
HV cable recommended typeHUBER+SUHNER Radox Elastomer S, screened, single core, automotive cable (FHLR4GC13X)
HV cable lug size35-8, 50-8, 70-8
Recommended cable lug35 mm²: Druseidt with narrow flange 03901
50 mm²: Druseidt with narrow flange 03903
70 mm²: Druseidt with narrow flange 03906
HV connection boxes- 1 x 3 phase box (SINGLE winding model)
- 2 x 3 phase box (DUAL winding model)
LV connector47 pin DEUTSCH HD34-24-47PE for resolver and temperature measurement
LV connector typeDEUTSCH HD34-24-47PE
LV connector pin typeGold plated
LV mating connector typeDEUTSCH HD36-24-47SE or DEUTSCH HD36-24-47SE-059
LV mating connector pin typeDEUTSCH 0462-201-1631, DEUTSCH 0462-005-2031
LV connector pin configurationPlug: DEUTSCH 0413-204-2005 (size 20)
Plug: DEUTSCH 0413-003-1605 (size 16)
LV connections (+LVB1 option)Connection box with 2x M25 cable glands (reserve 2x plugged M16 threads available) and terminal block for LV connections. See Table 2
Anti-condensation heater (+HEAT1 option)65 W 230 VAC Single phase heater resistor
Angle/Speed sensorType: Externally excited SIN/COS resolver
Pole pair number: 6
Input: 7 V
Frequency: 10 kHz
Output: 2 V +/- 0.2 V
Input impedance: 110 Ohm +/- 10%
Output impedance: 330 Ohm +/- 15%
Heater connector (+HEAT1 option)Hummel art no. 7651 0 51 01 D (combination of housing 7651 0 00 00 0, insert 7084 9 51 101/7084 9 51 12 1, crimp pins 7010 9 42 01 1)
Heater mating connectorHummel art no. 7550 6 51 02 D (combination of housing 7550 6 00 00 0, insert 7084 9 51 10 2 / 70849 51 12 2 and crimp socket 7010 9 42 00 2)
Heater connector pin typeHummel 7010 9 42 01 1
Heater connector pin configurationSee Table 3
Bearing temp. measurement connector type4-pin M12 A coded male
Bearing temp. measurement mating type4-pin M12 A coded female
Bearing temp. measurement connector pin configurationSee Table 4

Product Code and Options

Use product code including all needed options for ordering. Standard options are not given with the code as they are selected by default if a non-standard option is not selected. Standard options are indicated by a star (*).

Product codeDescription
EM-PM1375-T800-690V-20002000 rpm unit with the standard options
EM-PM1375-T800-690V-2000+BIN+RES12000 rpm unit that has insulated bearing in N-end and resolver

Table 5 Product code examples

VariantCodeDescriptionAdditional information
High voltage connections*One three-phase systemOne connection box containing one three-phase system with one M25 cable gland per phase, total of 3 pcs M25 cable glands
-DUALTwo galvanically isolated three-phase systemsTwo connection boxes each containing one three-phase system with one M25 cable gland per phase, total of 6 pcs M25 cable glands
Low voltage connections*Low voltage connections done with connectorDEUTSCH HD34-24-47PE connector for LV connections
+LVB1Low voltage connections done with connection box and terminal stripConnection box with 2x M25 cable glands (reserve 2x plugged M16 threads available) and terminal block for LV connections (not available with +TEMP5 option)
N-end attachment*FlangeSAE 4 flywheel housing
+NE2Male shaft + FlangeDIN5480 W50x2x24x8f + SAE 4 flywheel housing
Bearing lubrication and mounting direction*Greased for lifeDeep groove ball bearing, non-contact seal on both sides, any mounting direction (see user guide for details)
+BHSGrease lubricatedDeep groove ball bearing, open design, horizontal mounting direction (see user guide for details)
Bearing insulation*Non-insulated bearingsNon-insulated bearings
+BINInsulated bearing in N-endInsulated bearing in N-end
+BIAInsulated bearing in both endsInsulated bearing in both ends
Shaft grounding*NoneNone
+SG1D-end shaft groundingInbuilt grounding ring
Protection class*Standard protection classIP65 protection class
+IP67IP67 protection classIP67 protection class (not available with +BHS option)
Cable direction*Cable direction fixedCable direction towards D-end
+CNECable direction towards N-endCable direction towards N-end
Rotation sensor*NoneNo resolver
+RES1ResolverInbuilt non-contacting resolver, 6-pole pair
Side mounting*Side mounting12 x side mounting threaded holes M10x1.5. Plugged by default with M10x10, DIN 913, (ISO 4026), set screw
+SM1Side mountingNo side mounting holes available. In case side mounting holes are present, they are plugged by default.

Table 6 Option list

Winding temperature sensorsCodeDescriptionAdditional information
*Temperature surveillance3 x PT100 (two-wire) in windings
+TEMP4Redundant temperature surveillance6 x PT100 (two-wire) in windings
+TEMP5Redundant temperature surveillance12 x PT100 (two-wire) in windings (not available with +LVB1 option)
Bearing temperature sensors*None
+BTMP1PT100 in bearings
Anti-condensation heaters*None
+HEAT1One anti-condensation heater230 VAC / 65 W (see user guide for more information)
Marine classification*No marine classification
+CL1ABS American Bureau of Shipping
+CL2BV Bureau Veritas
+CL3DNV
+CL4LR Lloyd's Register
+CL5RINA
+CL6CCS China Classification Society

Graphs

Picture 1 Pressure loss vs coolant flow

A graph showing pressure loss in bar against volume flow in l/min. The curve starts at 0 bar at 0 l/min and rises to approximately 0.8 bar at 30 l/min.

Picture 2 Altitude derating

A graph showing altitude in meters against phase cable length in meters. The curve starts at approximately 3200m at 1m cable length and decreases to approximately 500m at 17m cable length.

Motors (temperature class F, maximum winding temperature +150°C)

TypeCoolant temperature +65°CCoolant temperature +40°CCoolant temperature +40 / +65°C
Cont. Torque [Nm]Cont. Power [kW]Nom. Current [A]Cont. Torque [Nm]Cont. Power [kW]Nom. Current [A]Nom. speed [rpm]Peak speed [rpm]Max. speed [rpm]Peak Torque [Nm]Volt/ rpm] (c
EM-PMI375-T800-690V-200062113011465913812620002800186721000.376
EM-PMI375-T800-690V-220064614914171616515722003200144420970.343
EM-PMI375-T800-690V-260059616215167118317226003800123121030.294

(a Peak torque achieved with one 210A inverter

(b Peak torque achieved with two 210A inverters

(c Back EMF for cold (+20°C)

The maximum allowed peak torque duration at stator winding starting temperature +90°C is 1.5 minutes. The given values indicate typical duration and are not verified. In case more accurate values are required, cyclic dimensions are needed.

PDF preview unavailable. Download the PDF instead.

AI506733497379en-000104 Danfoss A/S GPL Ghostscript 10.05.1

Related Documents

Preview Danfoss EM-PMI375-T1100-690V Electric Machine Data Sheet
Technical data sheet for the Danfoss EM-PMI375-T1100-690V electric machine, featuring permanent magnet internal technology. Details include features, general specifications, mechanical properties, cooling, temperature ratings, vibration tolerance, connections, and product code options.
Preview Danfoss EM-PMI540B-T3000 Electric Machine Data Sheet
Technical data sheet for the Danfoss EM-PMI540B-T3000 electric machine, featuring Synchronous Reluctance assisted Permanent Magnet (SRPM) technology, high efficiency, and robust design for demanding applications.
Preview Danfoss EM-PMI375-T800 Electric Machine Data Sheet
Technical specifications and features of the Danfoss EM-PMI375-T800 electric machine, a permanent magnet internal motor designed for demanding applications in electric and hybrid vehicles.
Preview Danfoss EM-PMI375-690V User Guide: Installation, Operation, and Maintenance of Electric Motors/Generators
Comprehensive user guide for Danfoss EM-PMI375-690V electric motors and generators. Covers SRPM technology, installation, operation, safety, maintenance, troubleshooting, and product options for heavy-duty and marine applications.
Preview Danfoss EM-PMI375-T500-690V Electric Machine Data Sheet
Technical specifications and features of the Danfoss EM-PMI375-T500-690V electric machine, a high-efficiency permanent magnet motor designed for demanding applications in hybrid and electric vehicles.
Preview Danfoss EM-PMI540B-T3000 Electric Machine Data Sheet
Technical data sheet for the Danfoss EM-PMI540B-T3000 electric machine, featuring synchronous reluctance assisted permanent magnet technology. Details specifications, features, applications, and product codes.
Preview Danfoss EM-PMI375-T500 Electric Machine Data Sheet
Technical specifications and features for the Danfoss EM-PMI375-T500 electric machine, a permanent magnet internal motor designed for demanding applications in hybrid and electric vehicles.
Preview Danfoss EM-PMI540B-T2000 Electric Machine Data Sheet
Technical data sheet for the Danfoss EM-PMI540B-T2000 electric machine, featuring permanent magnet internal technology. Details specifications, features, applications, and options for this high-efficiency motor.