Veridian Healthcare JXB-311 Non-Contact Infrared Thermometer Quick Start Guide

Veridian Healthcare Non-Contact Infrared Thermometer

Model: JXB-311 / Ref No: 09-313

Quick Start Guide

These brief instructions allow you to quickly begin using your Veridian Healthcare Infrared Thermometer for Body Temperature Measurements. For more detailed instructions covering all features, including Object/Surface and Room Temperature measurements, please refer to the full Instruction Manual.

Safety Information

The infrared technology used in this thermometer is safe and not harmful. However, it is recommended to avoid looking directly into the lens during use.

Measurement Modes

The Infrared Thermometer offers a selection of settings for person, object/surface, and room measurements.

How to Measure Body Temperature

Follow these steps to measure body temperature:

  1. Press and release the [Power/Scan Button] to turn the thermometer on. The unit will run a self-test, and all symbols on the display will momentarily appear. (See Figure 1: Display showing self-test sequence with all symbols active.)
  2. The display will show dashed lines, the selected mode, and the temperature unit (°F/°C). The thermometer is ready for measurement. (See Figure 2: Display showing dashed lines, selected mode, and temperature unit (°F/°C), indicating the thermometer is ready for measurement.)
  3. Press and release the [Power/Scan Button] while aiming the infrared lens at the individual's forehead, holding the thermometer approximately 0.5" – 1.0" away.
  4. When the thermometer is in the correct position, it will slightly [vibrate], indicating the positioning sensor has detected the ideal reading location and the measurement has been taken.
  5. The results will be displayed. (See Figure 3: Display showing a measured temperature, e.g., 98.6°F.)
  6. If the results are at or above 100.4°F (38°C), the device will [vibrate] 3 times, indicating a fever may be present.
  7. After approximately 30 seconds of non-use, the thermometer will automatically shut off.

To Toggle Between Modes

  1. Press and release the [Power/Scan Button] to turn the thermometer on. The unit will run a self-test and all symbols on the display will momentarily appear.
  2. Press and release the [Mode Button] to scroll through and select person, object/surface, and room temperatures. (See display examples: [Self-test], [Person Mode])

Customer Support

If you have any questions or are experiencing difficulties, please call the toll-free customer service help line for further assistance at 1-866-326-1313.

Models: JXB-311, Non-Contact Infrared Thermometer

File Info : application/pdf, 2 Pages, 597.30KB

PDF preview unavailable. Download the PDF instead.

93-2162-0720-QSG-VH-Infrared-09-313

References

Adobe PDF Library 15.0 Adobe InDesign 15.1 (Macintosh)

Related Documents

Preview Veridian Healthcare JXB-183 Non-Contact Infrared Thermometer User Manual
Comprehensive user manual for the Veridian Healthcare JXB-183 Non-Contact Infrared Thermometer. Learn about features, operation, troubleshooting, and specifications for accurate body, surface, and room temperature measurements.
Preview SmartHeart Talking Ear & Forehead Thermometer: Simple Step Instructions
A concise guide to using the SmartHeart Talking Ear & Forehead Thermometer, covering features, setup, and measurement procedures for both ear and forehead readings.
Preview Veridian Healthcare Instant Ear Thermometer Model 09-340 User Manual
Comprehensive user manual for the Veridian Healthcare Instant Ear Thermometer (Model 09-340), covering setup, operation, cleaning, troubleshooting, specifications, and warranty information.
Preview Veridian Healthcare Temple Touch Mini Thermometer User Manual | Model 09-330/09-331
Comprehensive user manual for the Veridian Healthcare Temple Touch Mini Thermometer (Model 09-330/09-331). Provides instructions for quick start, operation, mode switching, memory recall, battery replacement, troubleshooting, product specifications, and warranty information.
Preview Veridian Healthcare 2-Second Digital Thermometer Model 08-363 User Manual
Comprehensive instructions for using the Veridian Healthcare 2-Second Digital Thermometer Model 08-363, including operating instructions, measurement techniques for oral, rectal, and axillary use, changing modes, memory recall, battery replacement, care and cleaning, troubleshooting, product specifications, FCC statement, and warranty information.
Preview Veridian Healthcare Temple Touch Mini Thermometer 09-330/09-331 User Manual
Comprehensive user manual for the Veridian Healthcare Temple Touch Mini Thermometer (Models 09-330/09-331), providing instructions for use, troubleshooting, specifications, and warranty information.
Preview Veridian Healthcare Instant Ear Thermometer Model 09-340 Quick Start Guide
Quick start guide for the Veridian Healthcare Instant Ear Thermometer Model 09-340. Learn how to use the device for accurate ear temperature readings, including important notes and user instructions.
Preview SMARTHEART™ Automatic Digital Blood Pressure Wrist Monitor - Quick Start Guide
Quick start guide for the SMARTHEART™ Automatic Digital Blood Pressure Wrist Monitor (Model # 01-541) by Veridian Healthcare. Learn how to apply the cuff and take accurate readings.