1. SPECIFICATIONS
CX-91S-06-TDS | CX-91S-12-TDS | Performance Levels | |
Static Strength | 600 lbs. (Factory Tested) ** 500 lbs. (UL Verified) |
1200 lbs. (Factory Tested) ** 1000 lbs. (UL Verified) |
- Destructive Attack = Level I - Line Security = Level I - Standby Power = Level I - Endurance = Level IV (Relay Source #2 and #3) |
Dynamic Strength | 50 ft-lb | 70 ft-lb | |
Voltage Input | 12/24V DC | 12/24V DC | |
Current Draw | 510mA/285mA | 500mA/265mA | |
Dimensions (Body) | 9-7/8"W x 2"H x 1"D (250mm x 50mm x 25mm) |
10-1/2"W x 2-5/8"H x 1-1/2"D (266mm x 67mm x 39mm) |
|
Dimensions (Armature Plate) | 7-5/32"W x 1-3/4"H x 15/32"D (182mm x 44mm x 12mm) |
7-9/32"W x 2-13/32"H x 5/8"D (185mm x 61mm x 16.5mm) |
|
Endurance | 250 000 | 250 000 |
Figure 1: Basic Installation Concept & Accessories
2. INSTALLATION
- Drill the armature plate holes in the door using the sticker template provided.
- Attach the armature plate to the door with the hardware provided as per Figure 2.3.
- With the door closed, mark the door frame at the edge of the armature to properly align the electromagnet to the armature.
- Attach the mounting plate to the door frame using the self-tapping screws provided. Align the mounting plate with the mark from Step 3.
- Insert the wires through the hole in the mounting plate and into the electromagnet unit. Attach the electromagnet unit to the mounting plate with the Allen head fixing screw.
- Screw in the anti-tamper nuts to prevent unauthorized access and make sure to fully tighten the fixing screw with proper tool. A “T” Handle Allen Key.
- The electromagnetic lock must be installed in accordance with the following:
- Life Safety Code ANSI / NFPA 101.
- Local Authority having Jurisdiction.
- Manufacturer's installation instructions provided with each unit.
- Typical wiring method shall be in accordance with CSA C22.1, Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, Section 32.
Note: Install in indoor dry location. Use caution when changing factory default setting. It is recommended to apply a light coat of silicon lubricant to the mating surface on a monthly basis to prevent rust. Manufacturer's Instructions provided in each unit.
NOTICE: All models are recognized to: UL 294 and ULC S533-15 : Standard for Access & Egress. Models CX-91S-06 & CX-91S-12 are listed to: UL 1034, Standard for Burglary-Resistant Electric Locking Mechanism. UL 294, Access Control System Units ** Value not verified by UL.
Remark: All drawings shown are for illustration purpose only. Actual product may vary due to product enhancement.
3. TROUBLE SHOOTING
- Sensor not functioning:
- Improper attachment of electromagnet and armature plate.
- Modification of the PCB
- Door not locked:
- Incorrect wiring or no power from power supply
- Reduced holding force:
- Poor contact of electromagnet and armature. Be sure armature is loose enough that it can fully contact electromagnet along the entire length.
- Mating surface is dusty or damaged.
- Improper input voltage or wire size.
Door Contact Sensor; Max. Contact Rate: 40VDC, 0.25A
LED Status:
- Red = Locked
- Green = Released
- Off = No Input (Only for LED-TB Models)
IMPORTANT! Set the jumper position according to the power input correctly before switch ON the power.
Diagram showing wiring connections for power supply, push switch, dry contact, and timer settings (5s, 10s, 15s, 25s). Includes labels for PS, C, NO, NC, and jumper settings for 12 VDC and 24 VDC.
4. REGULAR INSTALLATION GUIDE (FIGURE 2)
Step 1: Fold the CX-91S Template along the dotted line up to 90°. Note: Installation Template Only for In-door E.M. Lock Model 300, 600, 1200.
Step 2: Close the door, position the EM lock mounting location as close to the door upper corner with a gap of 10mm.
Step 3: Place the template against the door & frame and drill holes according to template indications.
Step 4: Drill 2 holes on the frame and 3 holes on the door as indicated on the template.
Step 5: Install the Armature Plate to the door. Note: Actual installation may vary according to door figures.
Step 6: This allows the armature plate to pivot around the armature screw to compensate for door misalignment.
Step 7: Mount the FB600 on the door frame by screwing in the self-tapping screws on the holes as indicated on the template.
Step 8: Once the position is correct, screw in the other screws to permanently mount the plate, and drill the wire cable access hole.
Step 9: Use an Allen key wrench to unscrew the anti-tamper nut and tighten the fixing screws on the mounting plate.
Step 10: Connect to power supply and test unit.
5. LZ BRACKET FOR IN-SWING DOOR INSTALLATION GUIDE (FIGURE 3)
Step 1: Position the L-Bracket mounting location as close to the door upper corner with a gap of min. 10mm; ensure the door can close. The door frame minimum height value "L" is needed to accommodate the bracket Model: 800 LZ (H: 2-1/16" / 52mm), 1200 LZ (H: 2-7/8" / 73mm).
Step 2: Place the bracket and secure with fixing screws.
Step 3: Tighten the EM Lock on the L-Bracket by using the Allen Wrench.
Step 4: Assemble the Z-bracket and ensure the Z-bracket can be adjusted freely, before permanent tightening.
Step 5: Install the armature plate on the Z-Bracket, using the CSK screw provided in the screw pack.
Step 6: Close the door, and position the Z-Bracket by bringing the armature plate close to the EM Lock surface.
Step 7: Turn on the power of the EM Lock, let the armature plate attach to the EM Lock; adjust the position between the Z-Bracket and the door.
Step 8: Once the position is correct, screw in the self-tapping screws on the Z-Bracket to the door.
Wire Gauge Chart: A table shows recommended wire gauge (AWG) for different distances (25f to 1000f) and current draws (0.25A to 2.00A) for both 12VDC and 24VDC.
5. INSTALLATION
- Drill the armature plate holes in the door using the sticker template provided.
- Attach the armature plate to the door with the hardware provided as per Figure 2.3.
- With the door closed, mark the door frame at the edge of the armature to properly align the electromagnet to the armature.
- Attach the mounting plate to the door frame using the self-tapping screws provided. Align the mounting plate with the mark from Step 3.
- Insert the wires through the hole in the mounting plate and into the electromagnet unit. Attach the electromagnet unit to the mounting plate with the Allen head fixing screw.
- Screw in the anti-tamper nuts to prevent unauthorized access and make sure to fully tighten the fixing screw with proper tool. A “T” Handle Allen Key.
- The electromagnetic lock must be installed in accordance with the following:
- Life Safety Code ANSI / NFPA 101.
- Local Authority having Jurisdiction.
- Manufacturer's installation instructions provided with each unit.
- Typical wiring method shall be in accordance with CSA C22.1, Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, Section 32.
Note: Install in indoor dry location. Use caution when changing factory default setting. It is recommended to apply a light coat of silicon lubricant to the mating surface on a monthly basis to prevent rust. Manufacturer's Instructions provided in each unit.
NOTICE: All models are recognized to: UL 294 and ULC S533-15 : Standard for Access & Egress. Models CX-91S-06 & CX-91S-12 are listed to: UL 1034, Standard for Burglary-Resistant Electric Locking Mechanism. UL 294, Access Control System Units ** Value not verified by UL.
Remark: All drawings shown are for illustration purpose only. Actual product may vary due to product enhancement.
4. TROUBLE SHOOTING
- Sensor not functioning:
- Improper attachment of electromagnet and armature plate.
- Modification of the PCB
- Door not locked:
- Incorrect wiring or no power from power supply
- Reduced holding force:
- Poor contact of electromagnet and armature. Be sure armature is loose enough that it can fully contact electromagnet along the entire length.
- Mating surface is dusty or damaged.
- Improper input voltage or wire size.
Door Contact Sensor; Max. Contact Rate: 40VDC, 0.25A
LED Status:
- Red = Locked
- Green = Released
- Off = No Input (Only for LED-TB Models)
IMPORTANT! Set the jumper position according to the power input correctly before switch ON the power.
Diagram showing wiring connections for power supply, push switch, dry contact, and timer settings (5s, 10s, 15s, 25s). Includes labels for PS, C, NO, NC, and jumper settings for 12 VDC and 24 VDC.
5. REGULAR INSTALLATION GUIDE (FIGURE 2)
Step 1: Fold the CX-91S Template along the dotted line up to 90°. Note: Installation Template Only for In-door E.M. Lock Model 300, 600, 1200.
Step 2: Close the door, position the EM lock mounting location as close to the door upper corner with a gap of 10mm.
Step 3: Place the template against the door & frame and drill holes according to template indications.
Step 4: Drill 2 holes on the frame and 3 holes on the door as indicated on the template.
Step 5: Install the Armature Plate to the door. Note: Actual installation may vary according to door figures.
Step 6: This allows the armature plate to pivot around the armature screw to compensate for door misalignment.
Step 7: Mount the FB600 on the door frame by screwing in the self-tapping screws on the holes as indicated on the template.
Step 8: Once the position is correct, screw in the other screws to permanently mount the plate, and drill the wire cable access hole.
Step 9: Use an Allen key wrench to unscrew the anti-tamper nut and tighten the fixing screws on the mounting plate.
Step 10: Connect to power supply and test unit.
6. LZ BRACKET FOR IN-SWING DOOR INSTALLATION GUIDE (FIGURE 3)
Step 1: Position the L-Bracket mounting location as close to the door upper corner with a gap of min. 10mm; ensure the door can close. The door frame minimum height value "L" is needed to accommodate the bracket Model: 800 LZ (H: 2-1/16" / 52mm), 1200 LZ (H: 2-7/8" / 73mm).
Step 2: Place the bracket and secure with fixing screws.
Step 3: Tighten the EM Lock on the L-Bracket by using the Allen Wrench.
Step 4: Assemble the Z-bracket and ensure the Z-bracket can be adjusted freely, before permanent tightening.
Step 5: Install the armature plate on the Z-Bracket, using the CSK screw provided in the screw pack.
Step 6: Close the door, and position the Z-Bracket by bringing the armature plate close to the EM Lock surface.
Step 7: Turn on the power of the EM Lock, let the armature plate attach to the EM Lock; adjust the position between the Z-Bracket and the door.
Step 8: Once the position is correct, screw in the self-tapping screws on the Z-Bracket to the door.
Wire Gauge Chart: A table shows recommended wire gauge (AWG) for different distances (25f to 1000f) and current draws (0.25A to 2.00A) for both 12VDC and 24VDC.
File Info : application/pdf, 8 Pages, 1.06MB
DocumentDocumentRelated Documents
![]() |
Camden Door Controls Price List February 2011 A comprehensive price list from Camden Door Controls for February 2011, detailing their range of electronic door controls including electric strikes, magnetic locks, push buttons, relays, timers, and power supplies. |
![]() |
Camden CX-PS600UL Power Supply/Charger Installation Instructions Comprehensive installation guide for the Camden CX-PS600UL Power Supply/Charger, detailing specifications, features, fault indications, and wiring for access control systems. |
![]() |
Camden CX-CL-LZBRK L & Z Cabinet Lock Brackets Installation Guide Detailed installation instructions for Camden Door Controls CX-CL-LZBRK L & Z brackets, designed for CX-EPD0009 cabinet locks. Covers normal and sliding door installations, including package contents, specifications, and dimensions. |
![]() |
Camden CM-221M Touchless Exit Switch: Installation Guide and Features Comprehensive installation guide for the Camden CM-221M ValueWave™ touchless exit switch. Learn about features, specifications, wiring diagrams, configuration, and power requirements for ADA compliant access control. |
![]() |
CV-800SES Serial to Wiegand Converter Installation Instructions Installation instructions for the Camden CV-800SES Serial to Wiegand Converter, detailing its features, specifications, and connection procedures for SES, TEC/CAT, and Viscount Elektra Telephone Entry Systems. |
![]() |
Camden CI-1KX, CI-1KF, CI-1KXS, CI-1KFS Installation Instructions Detailed installation instructions for Camden Door Controls CI-1KX, CI-1KF, CI-1KXS, and CI-1KFS operators, including wiring schematics and safety precautions. |
![]() |
Camden CM-3000 Series Illuminated Switches Installation Instructions Comprehensive installation guide for Camden Door Controls CM-3000 Series illuminated exit switches, detailing product specifications, applications, wiring diagrams, parts information, and mounting options. |
![]() |
Camden CM-4085 and CM-5085 Series Mushroom Push Buttons Installation Instructions Installation instructions for Camden CM-4085 and CM-5085 Series Mushroom Push Buttons, including general description, specifications, application, installation, and wiring. |