INSTALLATION INSTRUCTIONS

STS 2.0 - Smart Touch Screen Control

CAUTION

[!] WARNING: ALWAYS DISCONNECT THE UNIT BEFORE PERFORMING MAINTENANCE OR MAKING ANY CONNECTIONS. FAILURE TO DISCONNECT POWER COULD RESULT IN ELECTRICAL SHOCK OR DAMAGE, TO THE WALL CONTROL OR THE ELECTRONIC COMPONENTS.

FOLLOW THE INSTRUCTIONS TO ENSURE PROPER OPERATION AND FUNCTIONALITY OF THE CONTROL AND VENTILATION SYSTEM. ONLY ONE WALL CONTROL PER VENTILATION SYSTEM IS POSSIBLE. KEEP WALL CONTROL & LOW VOLTAGE WIRES MINIMUM 2 FEET (610MM) AWAY FROM MOTORS, LIGHT BALLAST, DIMMERS AND ELECTRICAL PANELS. DO NOT ROUTE WALL CONTROL LOW VOLTAGE WIRES ALONG SIDE HIGH VOLTAGE WIRES. RECOMMENDED TYPE OF WIRE: LVT 18/4 CSA/UL.

BEST PRACTICE

For optimal operation of the ventilation control, the following best practices are recommended during installation:

INSTALLATION STEPS

Step 1: Detach Front Module

[Press tab to detach]

Detach the front module from the back plate by pressing the tab located at the top and bottom of the control casing.

Step 2: Route Wires and Mount Back Plate

[Routing the wires]

Guide the signal wires (4) through the central opening of the back plate. Mount this plate to either a standard electrical device box or directly to the wall using screws. If required, use wall anchors.

NOTE: Be sure the screws are secure but do not over tighten. This may result in damage to the back plate.

Step 3: Connect Wires to Terminal Block

[Terminal block (front module backside)]

Insert the wires (4) into the terminal block, located on the backside of the front module. Secure them in place by tightening the terminal screws using a small [3.0mm flat head screwdriver] (not included).

NOTE: For each wire, take note of the wire color chosen and connect to the corresponding terminals for the control and the HRV/ERV. See illustration below.

Terminal connections: B, A, D+

Step 4: Attach Front Module

Attach the front module to the mounted back plate. First, hook the top of the front module to the top clips of the back plate, then press the bottom of the front module until you hear a 'click'. Ensure the ventilation system operates correctly.

NOTE: Be careful not to pinch or trap the wires when attaching the front module to the back plate.

Step 5: Provide Operating Instructions

Leave operating instructions with the homeowner.

TROUBLESHOOTING

If error code 05 is displayed on the touchscreen control, double check the "A" and "B" signal wires. Ensure the DIP switches are in the bottom "OFF" position.

Models: STS 2.0 Smart Touch Screen Control, STS 2.0, Smart Touch Screen Control, Touch Screen Control, Screen Control, Control

PDF preview unavailable. Download the PDF instead.

445535-STS-2.0-Installation-manual Adobe PDF Library 17.0 Adobe InDesign 18.1 (Windows)

Related Documents

Preview Systemair Access Software Quick Guide
Concise guide for Systemair Access software versions 4.0-1-04 to 4.1-1-00, covering general information, alarms, regulator settings, and advanced HMI configurations for HVAC systems.
Preview Systemair Topvex Suspended Air Handling Units: Compact, Efficient Ventilation
Explore the Systemair Topvex series of suspended air handling units, designed for compact installation and energy efficiency. Ideal for various building types, featuring advanced Access control system for easy operation and monitoring.
Preview Systemair Topvex SoftCooler SR09/SR11 Operation and Maintenance Instructions
This document provides comprehensive operation and maintenance instructions for the Systemair Topvex SoftCooler SR09 and SR11 access control systems. It covers product description, installation, function descriptions, cooling flow charts, maintenance procedures, and alarm management.
Preview Manager Purchase Vacancy at Systemair Production B.V. - Waalwijk
Systemair Production B.V. is seeking a Manager Purchase in Waalwijk for a 40-hour week. This role involves leading a purchasing team, developing strategic purchasing policies, and collaborating with stakeholders to ensure quality, price, and delivery. Requirements include HBO/WO education, 5+ years of experience, strong negotiation skills, and fluency in Dutch and English. Systemair offers a competitive salary, benefits, and a positive work environment.
Preview Systemair SAVE VTR 150/B Installation Manual
Comprehensive installation manual for the Systemair SAVE VTR 150/B heat recovery ventilation unit. Covers general information, technical specifications, dimensions, mounting procedures for various kitchen hoods, electrical connections, system checks, commissioning, and disposal guidelines.
Preview Systemair Cleva Heat Recovery Units: Efficient Ventilation Solutions
Systemair's Cleva heat recovery units offer compact, energy-efficient ventilation for commercial spaces, offices, and schools. They provide high air tightness, low noise, advanced control, and flexible configurations, ensuring comfortable indoor climates with minimal energy consumption.
Preview Systemair Topvex SoftCooler SR09, SR11: Operation and Maintenance Manual
This manual provides detailed information on the operation, installation, and maintenance of the Systemair Topvex SoftCooler SR09 and SR11 access control systems. It covers system components, functions, technical specifications, and troubleshooting.
Preview Systemair EC-BASIC-H HUMIDITY Controller - Product Overview
Detailed product information for the Systemair EC-BASIC-H HUMIDITY controller, including technical specifications, dimensions, wiring, and features for humidity control in HVAC systems.