Product Name | Clean Air Optima CA-807 |
Rated Voltage and Frequency | 220V - 230V |
Rated Power Consumption | 344W (Rapid humidifying) / 44W (Natural humidifying) |
Mode | Artificial Intelligence, Sleep, Baby, Health protection |
Humidity Output | 400ml/h (Rapid humidifying) / 200ml/h (Natural humidifying) |
Water Tank Volume | 5 Liter |
Continuous Humidifying | 12h (Rapid humidifying) / 25h (Natural humidifying) |
Suitable for rooms up to | 70m² / 175m³ / 750ft² |
Weight | 6.9kg |
Dimension (mm) | 391(Width) x 238(Length) x 444(Height) |
Dimensions may change slightly to improve product performance.
Caution for Safety
Please follow the indications below to prevent unexpected risks or damage.
Symbols:
- ⚠️: Indicates facts and organizations that can pose a risk.
- ?: Indicates a ban.
- ✔️: Indicates obligatory compliance.
- ? Do not disassemble, repair, or renovate. Abnormal operation can result in electric shock, injury, and fire. Consult customer service for repairs.
- ⚡ Ensure the product voltage is 220V and 60Hz before connecting power. Incorrect voltage can cause fire and electric shock.
- ? Pull the plug out with dry hands during cleaning. Do not pull or insert the plug with wet hands, as this can cause fire and electric shock.
- ? Do not immerse the main frame in water or spray water on it. This can cause electric shock and fire.
- ? Do not move the humidifier during its use. This can cause errors or electric shock.
- ? Do not use if the electrical cord, power plug, or outlet is damaged or loose. This can cause electric shock, short circuits, and fire. In case of a damaged power cord, contact the place of purchase or customer service for exchange.
- ? Do not insert fingers or metal objects into the discharge or suction ports. Be especially careful with children.
- ? Do not damage, process, bend by force, pull, twist, or tie the cord line. Do not place heavy objects over or into the cord. Damaged cords can cause fire and electric shock.
- ? Do not let infants go closer to, touch, or manipulate the product. This can cause electricity hazards or injury.
- ? When pulling the plug out, hold the plug body, not the cord. Ensure the plug is clean before use. Pulling by the cord can cause electric shock or short circuits, triggering fire.
- ? Replace the water in the tank with new water daily. Keep the water tank clean. Using the product without regular cleaning can lead to bad smells from fungi or germs. Tap water is suitable.
- ☣️ Do not clean with benzene, thinner, or spray pesticides. This can cause cracks, electric shock, and fire.
- ☀️? Do not keep the product in places exposed to direct sunlight or heaters. This can cause deformation, smearing, and discoloration.
- ⚡ If water enters the power supply part, pull the plug out immediately and contact the service center. This can cause electric shock and fire.
- ? If you notice noise, a burning smell, or smoke from the product, immediately cut off the power and contact the service center. This can cause deformity or discoloration.
- ? Do not put other foreign objects, such as metal, into the product. This can cause electric shock and injury.
- ? Do not inhale humidity directly from the product's discharge port.
- ?️ Do not install in places that are wet, dirty, or where water or rainwater can be splashed. This can cause electric shock and fire.
- ? Do not use the product with the power plugs of multiple devices plugged into a single electrical outlet simultaneously. This can cause errors and fire.
- ⚙️ When cleaning, cut off the power and clean after the fan stops rotating. This can cause electric shock and injury.
- ?️ Do not sit on or lean against the body frame. This can cause damage.
- ?️ Do not use in places where wind blows from windows or air conditioners. Avoid locations where humidity from the product can directly contact ceilings, walls, furniture, or electronic appliances, as this can affect sensor accuracy.
- ? Do not place combustibles, burning cigarettes, or incense near the product. This can cause a fire.
- ? Ensure all parts, including the humidity filter (Rotor), ECO-Air Plus filter, Nano-Zilver Filter, water tank, and cover, are correctly reassembled before operation. Operating without them can cause errors.
- ☠️ Do not use the product when indoor smoking or fuming pesticides are used. Chemicals accumulated in the product can be emitted from the discharge port, harming health.
- ? Do not place objects on top of the product. This can cause injury, electric shock, or errors.
- ⏳ When the product is not used for a long time, pull the plug out and empty all water from the water tank and body frame. Fungi or germs may increase.
- ? Install the product on a strong and flat floor. Failure to do so can cause the product to fall, spill water, and potentially lead to fire or electric shock.
- ? Do not use a damaged water tank. This can cause water leakage or overflow, triggering electric shock and errors.
- ?️ When using the product, ensure adequate ventilation. Do not place the side with the filter facing a wall, especially in poorly ventilated rooms, as it can affect performance and potentially cause fire.
- ? Do not drink the water remaining in the body frame or water tank. The water quality may degrade, and it could lead to unexpected accidents.
- ? Do not block the discharge port, for example, with a curtain or towel. This can cause errors.
- ? Do not use the product near places with strong magnetic fields, such as microwaves or TVs, as this can affect sensor performance.
- ⚠️ If the unit falls, unplug it immediately and dry it thoroughly before attempting to use it again.
- ? When the product is not used, do not store it for a long time with water in the water tank, as fungi or germs may increase.
- ? Do not move the product by pulling the power cord. This can cause electric shock and fire.
- ? Ensure the unit is completely dry after cleaning or if water has entered the power supply part.
- ❄️ If there is a concern for freezing, dump all water from the body frame and water tank. Frozen products can cause errors.
- ? Dump the water remaining in the body frame or water tank during movement. Moving the product with water inside can cause overflow.
- ? Do not place magnets or metal objects on the body frame. This can cause errors.
- ? Empty the water tank by removing the tank itself, not by tilting the main body frame. Water entering the body frame can cause errors.
- ? Clean the unit regularly according to the 'How to clean' instructions. Serious contamination can lead to increased fungi, bad smells, and reduced humidity output.
- ?️ Use clean tap water, preferably not exceeding 40°C. Avoid water contaminated with salt, detergent, or medication. Using water over 40°C can cause product errors.
- ?️ Do not use the product for special purposes such as preservation of food, artwork, or academic journals. This can lead to low quality results.
Name and Function of Each Part
Front Side and Inside Parts:
- Operation Part: Controls and indicators for the device. (Refer to Operation Part section on page 11)
- Part displaying humidity: Shows the current room humidity level. (Refer to Operation Part section on page 11)
- Window: Allows viewing the water level in the water tank.
- Discharge port: Where humidified air is released.
- Water tank: Holds the water for humidification. Use only water.
- Humidity filter (Rotor): Coated with water-friendly and antibacterial material to prevent germ growth and filter air.
- Nano-Zilver Filter: Cleans and prevents germ growth in the water.
- Cap of water tank: Seals the water tank to prevent leaks. Ensure it is closed properly.
- Air inlet: Where dry air is drawn into the unit.
- Eco-Air Plus Filter: Provides deodorizing and antibacterial functions, filtering contaminated air.
- Air inlet cover: Protects the Eco-Air Plus Filter.
- Water bassin: Holds water and submerges the humidification filter.
Operation Part Details
Buttons:
- Rapid humidifying ON/OFF Button: Activates or deactivates rapid humidification.
- Natural humidifying Button: Activates or deactivates natural humidification.
- Mode button: Selects operating modes: Sleep, Baby, Artificial Intelligence, Health Protection, Manual.
- Power button: Turns the product on and off.
- Humidity button: Adjusts humidity levels (Weak, Strong, Turbo).
- Reserving button: Sets the timer for operation.
Displays:
- Part for displaying humidity: Shows current room humidity with LED indicators (e.g., 30%, 40%, 50%, 60%, 70%).
- Display of no water condition: Illuminates with a melody when the water tank is empty.
Humidity Zones indicated by LEDs:
- Dry Zone (30%~45%)
- Fresh Zone (45%~60%)
- Wet Zone (Over 60%)
How to Install
The airwasher should be installed on a strong, flat surface with good air circulation. Facing the unit towards the center of the room can create more effective airflow.
Recommended Placement:
- Over 1 meter from the ceiling.
- Over 20cm from the left and right walls.
- 30cm from the front.
- Do not block the filters on the side.
Additional Installation Notes:
- Pull the plug and empty the water tank if the unit is moved or used for a long time to prevent overflow and germ growth.
- Do not use the unit while it is leaning. It may not function correctly or may overflow.
- Ensure suction and discharge ports are not obstructed.
- Install at least 2 meters away from AV devices like TVs or radios to prevent interference or noise.
- Avoid placing near direct light or heaters, which can cause deformation or discoloration.
- Install on a flat surface. Slanted placement may activate the water sensor and stop the product.
- Use in indoor environments with low humidity. High ambient humidity can reduce the product's effectiveness.
How to Use
Preparation Before Using:
- Ensure the unit is clean.
- Do not put combustibles into the water tank; it can cause fire.
How to Supply Water:
- Use clean tap water daily.
- Open the cap of the water tank and remove the water tank from the body.
- Open the cap of the water tank and fill it with tap water.
- Close the cap of the water tank securely.
- Insert the water tank back into the body frame, ensuring it is correctly oriented. Close the water tank cover.
Use tap water below 40°C. Do not use water containing chemical agents, dirty water, or detergent, as this can cause deformity and errors.
Notice:
- Evaporative humidifying system: Steam is not visible as it is a natural evaporative type without boiling water.
- Air from ventilator: The air from the ventilator is not warm because it cools down during evaporation. It may feel cool depending on room size.
- Rapid humidifying: Can be set to increase humidity quickly using a Hybrid method.
- Humidity changes: Humidity levels can vary based on room temperature and existing humidity. In Manual Mode, if humidity exceeds 70% for over 2 hours, it may switch to 'Weak' operation. It returns to normal if humidity drops below 60%.
- Operating sensor: The unit automatically adjusts based on nearby humidity levels. The sensor monitors current humidity to maintain the set mode's optimal level. Humidity readings may differ slightly due to temperature variations or airflow. It may take a few minutes for the sensor to stabilize during initial operation.
- Displaying room humidity: The unit displays the current room humidity. The humidity sensor in the body frame indicates levels with colors: Orange for dry, Blue for proper humidity, and White for excessive humidity. Readings can vary based on location and initial operating conditions.
Humidity Control
Notice:
- If initial indoor humidity is below 30%, select 'Turbo' for rapid humidification.
- Initial setting is 'Turbo'. Press the humidity button to cycle through Weak, Strong, and Turbo settings.
Mode Selection
Press the Mode button to cycle through the following modes: Sleep, Baby, Artificial Intelligence, Health Protection, and Manual. You can return to Manual Mode by pressing the Humidity and Mode buttons.
If current humidity is higher than the set level, humidifying may stop, and the fan may operate at 'Weak' speed.
- 1. Sleep mode: Operates with low noise suitable for sleep. All LEDs are off except the Sleep LED. Humidity output is set to 'Weak'.
- 2. Baby Mode: Alternates between 'Weak' and 'Strong' humidifying to maintain humidity suitable for babies (around 66%).
- 3. Artificial Intelligence mode: Alternates between 'Turbo', 'Strong', and 'Weak' operations to maintain humidity suitable for infants (around 55%).
- 4. Health Protection Mode: Alternates between 'Turbo', 'Strong', and 'Weak' operations to maintain humidity beneficial for preventing colds and protecting skin. The target humidity adjusts between 50-70% within a temperature range of 10-40°C.
Rapid Humidity (Warm)
Use the Rapid Humidity button when you want to increase humidity quickly. This function can double the humidity output for a faster environmental improvement.
Reserving Time
Notice: Reserving Time can be operated in all modes. Changing modes cancels the reservation. Press the reserving time button to set the desired operation time. Cycle through settings: Continuous (Co), 1, 2, 3, 4, 5, 6, 7, 8 hours, and back to Continuous (Co).
When the set time is reached, the unit stops automatically and enters standby mode with the power LED on. If the water runs out, the 'No Water' indicator will light up with a melody, and humidification will stop.
Displaying the Current Humidity
The LED indicators on the operation part and the humidity display part show the current room humidity.
Operation Part Display:
- 40% LED: Current humidity is less than 49%.
- 50% LED: Current humidity is 50-59%.
- 60% LED: Current humidity is 60-69%.
- 70% LED: Current humidity is 70% or more.
Part to Display Humidity (LED Bar):
- The LED bar displays humidity in ranges:
- 30% range: 30%-33%, 34%-36%, 37%-39%
- 40% range: 40%-43%, 44%-46%, 47%-49%
- 50% range: 50%-53%, 54%-56%, 57%-59%
- 60% range: 60%-63%, 64%-66%, 67%-69%
How to Clean
Important: Always pull the plug out before cleaning. Regular cleaning is essential to maintain performance and prevent odors.
Water tank (Daily):
- Shake the water tank with water inside 4-5 times after closing the cap.
- Do not add chemical agents.
- Clean inside the water tank regularly by hand.
Body frame (When contaminated):
- Wipe with a soft cloth dampened and wrung out from a diluted neutral detergent.
- Finally, wipe dry with a towel.
- Do not use benzene, thinner, alkaline detergent, or powdered detergent, as they can cause deformation and discoloration.
ECO-Air Plus filter:
- Recommended to clean once a week.
- Remove dust from the surface using a cleaner or a soft brush.
- Do not clean the ECO-Air Plus filter with water, as it may impair performance.
- Do not operate the unit without the ECO-Air Plus filter.
Filter Exchange:
- Exchange the Nano-Zilver filter once per year.
- Exchange the ECO-Air Plus filter once per 6 months.
- Order accessories at: https://www.cleanairoptima.com/accessoires/mg/44/
How to Clean Up
Clean water tank part twice a week: If water is left in the tank after use, it can change color or develop odors.
- Remove the cover of the water tank.
- Remove the water tank.
- Pull the water tank out.
- Remove the water bassin part.
- Dump the water in the water bassin after removing the humidifying filter (Rotor) and Nano-Zilver filter.
- Wash the Nano-Zilver filter with flowing water.
- Clean the water bassin part with a soft sponge and reassemble in reverse order.
Installing Parts:
- Water level sensor: Lay the sensor at the bottom of the protrusion and insert its axis into the hole of the water tank part.
- Water bassin: Install the water bassin part into the body frame after putting the humidifying filter (Rotor) in. Ensure it clicks into place.
- Water tank: Install the water tank and water tank cover into the body frame. Ensure correct orientation.
When removing the water tank, do not tilt it to avoid water overflow and potential electric shock or fire hazards.
Clean the Humidification Filter (Rotor)
Clean the humidification filter (Rotor) 2-3 times per week. Water moss may gather depending on water quality.
Notice: Do not use benzene, thinner, alkaline detergent, or powdered detergent. Refer to page 20 for removing the filter.
- Disassemble the humidifying filter (Rotor).
- Wipe it with a soft sponge after soaking it in water.
- For stubborn stains: Soak the filter in tepid water (under 40°C) with dissolved neutral detergent for 3 hours, then rinse thoroughly with clean water. Do not boil or wash in boiling water, as it can deform the product.
- For water scum: Wash the filter with citric acid. Mix approximately 30g of citric acid with 1.5 liters of warm water.
- Assemble the humidifying filter (Rotor).
- After installing the filter into the water bassin, install the water tank and water tank cover into the body frame. Ensure the filter is correctly seated in its groove.
What if you think there are errors?
If you suspect an error after checking the following, stop using the product immediately, unplug it, and contact customer service to prevent accidents. Do not attempt self-repair.
Contact: Tel: +49(0)5921 878-121, E-mail: info@optima-luftreiniger.de
Cases | Check as follows | Reference Page |
---|---|---|
Not working | Is the plug inserted into the electrical outlet? | 15P |
Is the water tank part installed correctly? | 13P, 21P | |
Turning the lamp for complementing water on | Is the water tank containing water? Fill the water tank. | 13P |
Is the water tank part missing? Insert the water tank part fully. | 21P | |
Is the sensor of water level missing? Install the sensor of water level. | 21P | |
Leaking water | Is the cap of the water tank closed well? Check the cap. | 13P |
Is the body frame leaning? Use the body frame on a flat place. | 12P | |
Inside water tank staining with powder | This is material accumulated with dirt or hard material due to long-term use. Make sure to clean up periodically. | 19~22P |
Sounding operation even in stopping condition | Is splashing sound heard? This comes from water in the tank when filling water (it is not an error). | 14P |
A little humidity | If indoor humidity is high or temperature is low, humidity output can be reduced. | 14P |
Is the air filter blocked? Clean the filter and use. | 19P | |
You may feel low humidity during use in a spacious place. | 15P |
Environmental Information
This product must not be disposed of with normal household waste at the end of its life. It must be brought to a collection point for the recycling of electrical and electronic equipment. The symbol on the product, manual, or packaging indicates this.
Materials are reusable according to their labeling. By recycling, material recycling, or other forms of utilizing old devices, you make an important contribution to protecting our environment. Please inquire at your local town hall for the appropriate disposal center.
Service and Warranty
Warranty:
Clean Air Optima ensures your airwasher against defects in materials and/or workmanship for up to two years after the initial purchase. If material or manufacturing faults occur, they will be resolved by Clean Air Optima, or Clean Air Optima will provide a replacement device with the same or better properties.
The guarantee covers any damage caused by carelessness in handling, accident, abuse, lack of cleaning and maintenance, or other use not compatible with the information in these instructions. General commercial law also applies.
We recommend returning the instrument in case of failure, along with the original sales receipt and a brief description of the defect found. Contact your supplier, or if not possible, contact Clean Air Optima.
If the defect is not due to material and/or workmanship, processing or repair costs will be billed.
Contact:
Clean Air Optima Germany GmbH
Enschedestraße 14
48529 Nordhorn
Germany
E-mail: info@optima-luftreiniger.de
Website: www.optima-luftreiniger.de