Product Specification
Product Name | Clean Air Optima CA-807 |
Rated Voltage and Frequency | 220V - 230V |
Rated Power Consumption | 344W (Rapid humidifying) / 44W (Natural humidifying) |
Mode | Artificial Intelligence, Sleep, Baby, Health protection |
Humidity | 400ml/h (Rapid humidifying) / 200ml/h (Natural humidifying) |
Water Tank Volume | 5 Liter |
Continuous Humidifying | 12h (Rapid humidifying) / 25h (Natural humidifying) |
Suitable for rooms up to | 70m² / 175m³ / 750ft² |
Weight | 6.9kg |
Dimension (mm) | 391 (Width) x 238 (Length) x 444 (Height) |
Note: Dimensions may vary slightly to improve product performance.
Caution for Safety
Follow the indications below to prevent unexpected risks or damage. Safety cautions are divided based on the size of expected risk and urgency level.
[Mandatory Symbol]: Indicates obligatory compliance.
[Prohibited Symbol]: Indicates a ban.
[Caution Symbol]: Raises awareness about facts and organizations that can pose a risk.
- [Prohibited] Don't disassemble, repair, or renovate the unit. Abnormal operation can result in electric shock, injury, and fire. Consult customer service for repairs.
- [Prohibited] Connect the power only after verifying the product's voltage is for 220V and 60Hz. Incorrect voltage can cause fire and electric shock.
- [Prohibited] Pull the plug out during cleaning. Do not pull or insert the plug with wet hands. This can cause fire and electric shock.
- [Prohibited] Do not soak the main frame in water or spray water on it. This can cause electric shock and fire.
- [Prohibited] Do not move the unit while it is in use. This can cause errors or electric shock.
- [Prohibited] Do not use the unit if the electrical cord or power plug is damaged, or if the electrical outlet is loose. This can cause electric shock, short circuits, and fire. In case of a damaged power cord, contact the place of purchase or customer service for replacement.
- [Prohibited] Do not insert foreign objects such as fingers or metal into the discharge or suction ports. Be especially careful with children.
- [Prohibited] Do not damage, process, bend by force, pull, twist, or tie the cord. Do not place heavy objects on or in the cord. A damaged cord can cause fire and electric shock.
- [Prohibited] Do not let infants get close to, touch, or manipulate the product. This can cause electric shock or injury.
- [Prohibited] When pulling the plug out, do not hold the cord. Ensure you pull the plug by holding the front. Clean any dirt or foreign objects from the power plug before use. This can cause electric shock or short circuits, triggering fire.
- [Prohibited] Do not clean the unit with benzene, thinner, or spray pesticide on it. This can cause cracking, electric shock, and fire.
- [Prohibited] Do not keep the product in places exposed to direct sunlight or heaters. This can cause deformation, smearing, and discoloration.
- [Prohibited] Do not put water into the nebulizer. This can cause errors, injury, fire, and electric shock.
- [Prohibited] If water gets into the power supply part, pull the plug out and contact the service center. This can cause electric shock and fire.
- [Prohibited] If you notice unusual noise, a burning smell, or smoke, immediately cut off the power and contact the service center. This can cause deformity or discoloration.
- [Prohibited] Do not put other foreign objects, such as metal, inside the product. This can cause electric shock and injury.
- [Prohibited] Do not inhale humidity directly from the product.
- [Prohibited] Do not install the unit in wet, dirty places, or where water or rainwater can splash. This can cause electric shock and fire.
- [Prohibited] Do not use the unit with multiple product power plugs inserted into one electrical outlet simultaneously. This can cause errors and fire.
- [Prohibited] When cleaning, cut off the power and clean after the fan stops rotating. This can cause electric shock and injury.
- [Prohibited] Do not sit on or lean against the body frame. This can cause damage.
- [Prohibited] Do not use the unit in a place where wind blows from a window or air conditioner. Avoid placing it where the unit's humidity can directly contact ceilings, walls, furniture, or electronic appliances. This can prevent the humidity sensor from working correctly.
- [Prohibited] Do not place combustibles, burning cigarettes, or incense near the product. This can cause a fire.
- [Prohibited] Do not use the product when indoor smoking or fuming pesticides are used. Harmful substances accumulated in the product can be emitted from the discharge port, harming health.
- [Prohibited] Do not place objects on top of the product. This can cause injury, electric shock, and errors.
- [Prohibited] When not using the product for a long time, pull the plug out and empty any remaining water from the body frame and water tank. This can cause electric shock and fire, and fungi or germs may increase.
- [Prohibited] Install the product on a strong and flat floor. Failure to do so can cause the product to fall, spill water, and potentially lead to fire or electric shock.
- [Prohibited] Do not use a damaged water tank without replacement. This can cause water to leak or overflow, leading to electric shock and errors.
- [Prohibited] When using the product, do not position the side with the filter facing a wall, especially in poorly ventilated rooms, as this can lead to poor performance and potential fire hazards.
- [Prohibited] Do not drink the water remaining in the body frame or water tank. This can degrade water quality and cause accidents.
- [Prohibited] Do not block the discharge port with curtains or towels, as this can cause errors.
- [Prohibited] Do not use the unit near places with strong magnetic fields, such as microwaves or TVs, as this can affect sensor performance.
- [Prohibited] Do not drop the body frame. If it falls, pull the plug and dry it thoroughly before use.
- [Prohibited] When the product is not in use, do not store it for a long time with water in the tank, as fungi or germs may increase.
- [Prohibited] Do not move the product by pulling the power cord. This can cause electric shock and fire.
- [Prohibited] Ensure all water is dried completely from the unit.
- [Prohibited] Use clean tap water. Do not use water hotter than 40°C or water contaminated with salt, detergent, or drugs. Using hot water can cause product errors.
- [Prohibited] Do not use the product for special purposes like preservation of food, artwork, or academic journals, as this can lead to low quality.
- [Mandatory] Replace water in the tank with new water daily. Clean the water tank regularly. Using the product without cleaning can lead to bad odors from fungi or germs.
- [Mandatory] Make sure to put parts back in their original places after cleaning. Do not operate without the humidity filter (Rotor), ECO-Air Plus filter, Nano-Zilver Filter, water tank, or cover. This can cause errors.
- [Mandatory] Dump water if freezing is a concern. Empty the water tank and body frame to prevent damage from freezing.
- [Mandatory] Dump water remaining in the body frame or water tank during movement to prevent overflow.
- [Mandatory] Do not place magnets or metal objects on the body frame. This can cause errors.
- [Mandatory] Do not drain water from the water tank by holding the body frame. Drain water by removing the water tank. Water entering the body frame can cause errors.
- [Mandatory] Clean the unit regularly according to the 'How to Clean' section (pages 19-22). Serious contamination can increase fungi, cause bad odors, and reduce humidity performance.
Name and Function of Each Part
Front Side and Inside Parts
- Operation Part: Controls the unit's functions. Refer to the Operation Part description.
- Humidity Display Part: Shows the current humidity level. Refer to the Operation Part description.
- Window: Allows viewing the water level in the water tank.
- Discharge Port: Where humidified air is released.
- Water Tank: Holds the water for humidification. Use only water.
- Humidity Filter (Rotor): Coated with water-friendly and antibacterial material to prevent germ growth and filter contaminated air during humidification.
- Nano-Zilver Filter: Cleans and prevents germs from growing in the water.
- Cap of Water Tank: Seals the water tank to prevent leaks. Ensure it is closed properly.
- Air Inlet: Where dry air is drawn into the unit.
- Eco-Air Plus Filter: Provides deodorizing and antibacterial functions, filtering contaminated air.
- Air Inlet Cover: Protects the filters.
- Water Bassin: Holds water and submerges the humidification filter.
Operation Part
- Button for Rapid Humidifying: Turns rapid humidification ON or OFF.
- Mode Button: Selects operating modes: Artificial Intelligence, Sleep, Baby, Health Protection, or Manual.
- Power Button: Turns the unit ON and OFF.
- Humidity Button: Adjusts humidity levels (Weak, Strong, Turbo).
- Reserving Button: Sets a timer for operation.
Display Areas
- Part for Displaying Humidity: Indicates humidity zones: Wet Zone (Over 60%), Fresh Zone (45-60%), Dry Zone (30-45%).
- Display of No Water Condition: Illuminates with a melody when the water tank is empty.
- Displaying the Current Humidity: Shows the current room humidity using LEDs: Orange (Dry, <49%), Blue (Proper, 50-69%), White (Excessive, >70%). The LED Bar indicates humidity in 3% increments within each zone (e.g., 30-33%, 34-36%).
How to Install
The unit should be placed on a strong, flat floor with good air circulation. For optimal airflow, position the unit facing the center of the room.
Recommended Clearances:
- Over 1 meter from the ceiling.
- Over 20 cm from walls on the left and right sides.
- 30 cm from the front.
Important Installation Notes:
- Do not block the filters located on the sides.
- When moving or for long-term storage, unplug the unit and empty the water tank. This prevents water overflow and the growth of fungi or germs.
- Do not use the unit while it is leaning; this can lead to malfunction or water overflow.
- Ensure the suction port and discharge port are not obstructed.
- Install at a distance of over 2 meters from AV devices like TVs or radios to prevent operational noise.
- Avoid placing the unit near sources of electronic waves (e.g., speakers, electronic cookers) as this may affect the water level sensor's accuracy.
- Do not place the unit next to sources of direct light or heaters, as this can cause the unit's body to deform or discolor.
- Install on a flat surface. If placed on a slanted surface, the water sensor may malfunction, causing the product to stop working.
- Use the unit indoors in environments with low humidity. If the surrounding humidity is already high, the unit's effectiveness may be reduced.
Using the Airwasher
How to Supply Water
- Ensure the unit is clean at all times by replacing water daily.
- Open the cap of the water tank and remove the water tank from the body frame.
- Open the cap of the water tank and fill it with tap water.
- Close the cap of the water tank securely. Ensure it is inserted in the correct direction.
- Insert the water tank back into the body frame, ensuring it is properly seated. Close the water tank cover.
Notes:
- Use tap water that is less than 40°C.
- Do not use water containing chemical agents, dirty water, or detergent, as this can cause deformity and errors.
Operation
After inserting the power plug into a 220V-230V outlet, press the Power button. The unit will start operating with a melody. The initial setting is Manual mode, Humidity-Turbo.
Create a clean indoor environment by using the operation controls as described below. When not in use, unplug the unit.
Notice:
- Remove all water from the tank when not using the unit for an extended period.
- If the air from the discharge port feels cold, or if the water level in the tank decreases rapidly, it may be due to cold water or high ambient humidity. Using Rapid Humidity mode can increase humidity by approximately double.
Humidity Control
Press the Humidity button to cycle through and select the desired humidity level: Weak, Strong, or Turbo.
- For initial indoor humidity below 30%, select 'Turbo' for rapid humidity increase.
- The unit defaults to Turbo mode upon initial startup.
Mode Selection
Press the Mode button to cycle through the operating modes in the following order: Sleep, Baby, Artificial Intelligence, Health Protection, and Manual.
You can return to Manual Mode by pressing the [Humidity] and [Mode] buttons.
- If the current indoor humidity is higher than the set level, the unit may stop humidifying and the fan may operate at the 'Weak' setting.
- 1. Sleep Mode: Operates at low noise levels suitable for sleep. All mode LEDs are OFF, and the Sleep LED is ON. Humidity is set to 'Weak'.
- 2. Baby Mode: Aims to maintain approximately 66% humidity, suitable for babies, by alternating between Weak and Strong humidifying operations.
- 3. Artificial Intelligence Mode: Aims to maintain approximately 55% humidity, suitable for infants, by alternating between Turbo, Strong, and Weak humidifying operations.
- 4. Health Protection Mode: Aims to maintain optimal humidity for preventing colds and protecting skin, by alternating between Turbo, Strong, and Weak humidifying operations. The target humidity adjusts based on ambient temperature (50-70% between 10-40°C).
How to Use Rapid Humidity (Warm)
Press the Rapid Humidity (Warm) button when you want to increase humidity quickly. This mode can double the humidification rate, helping to maintain a clean environment.
How to Use 'Reserving Time'
You can reserve the operation time by pressing the Reserving Time button. The unit cycles through 'Co' (Continuous), 1, 2, 3, 4, 5, 6, 7, 8 hours, and back to 'Co'.
Notice:
- Reserving Time can be operated in all modes. Changing modes will cancel the set reservation time.
- When the set time is reached, the unit stops automatically and enters standby mode with the power LED illuminated.
- If the water runs out, the 'No Water' indicator will light up with a melody, and humidification will stop.
Displaying the Current Humidity
The LEDs on the operation part and the dedicated humidity display part indicate the current room humidity.
- Operation Part LEDs:
- 40% LED: Indicates current humidity is less than 49%.
- 50% LED: Indicates current humidity is 50-59%.
- 60% LED: Indicates current humidity is 60-69%.
- 70% LED: Indicates current humidity is 70% or more.
- Part to Display Humidity (LED Bar):
- The range for each LED bar segment is approximately 3%. For example: 30-33%, 34-36%, 37-39% (for the 30% range); 40-43%, 44-46%, 47-49% (for the 40% range), and so on.
Notice: Humidity readings can vary based on location due to temperature differences and airflow. Readings may also differ slightly from other humidifiers or shortly after operation begins, as the sensor stabilizes.
How to Clean
[Mandatory] Pull the plug out before cleaning. Clean regularly to prevent performance degradation, breakdowns, and unpleasant odors caused by serious contamination.
Water Tank (Daily)
- Close the cap of the water tank.
- Fill the water tank with water and shake it 4-5 times.
- Clean the inside of the water tank by hand.
Notes:
- Do not add chemical agents.
Body Frame (As needed)
- Wipe the body frame with a soft cloth that has been dampened and wrung out. Use a diluted solution of neutral detergent for kitchens.
- Wipe again with a clean, dry towel.
Notes:
- Do not use benzene, thinner, alkaline detergent, or powdered detergent, as these can cause deformation and discoloration.
ECO-Air Plus Filter (Recommended Weekly)
- Remove dust from the surface of the ECO-Air Plus Filter using a vacuum cleaner or a soft brush.
Notes:
- Do not clean the ECO-Air Plus filter with water, as this may degrade its performance.
- Do not operate the unit without the ECO-Air Plus filter installed.
Filter Replacement Schedule
- Nano-Zilver Filter: Exchange once per year.
- ECO-Air Filter: Exchange once every 6 months.
- Where to order: https://www.cleanairoptima.com/accessoires/mg/44/
Water Tank Part (Clean Twice a Week)
If water is left in the tank after use, it can change color or develop an odor.
- Remove the water tank cover.
- Remove the water tank.
- Pull out the water tank and then remove the water bassin part.
- Pull out the humidifying filter (Rotor) and the Nano-Zilver filter.
- Dump the water from the water bassin.
- Wash the Nano-Zilver filter with flowing water.
- Clean the water bassin part with a soft sponge.
- Assemble the parts in the reverse order:
- Install the water level sensor at the bottom of the protrusion.
- Insert the axis of the water level sensor into the hole of the water tank part.
- Insert the humidifying filter (Rotor) into the water bassin part.
- Install the water bassin part into the body frame until it clicks securely.
- Install the water tank into the body frame. Ensure correct orientation.
- Install the water tank cover.
Notes:
- When pulling out the water tank, do not tilt it. Tilting can cause water to overflow, leading to electric shock, injury, or fire.
- Ensure the humidifying filter is inserted correctly into the water tank part.
- The unit will not operate if the water bassin is not completely installed.
Humidification Filter (Rotor) (Clean 2-3 times per week)
Water moss may accumulate depending on water quality. Clean if contamination is severe.
Notes:
- Do not use benzene, thinner, alkaline detergent, detergent for removing fungi, or powdered detergent.
- Refer to page 20 for instructions on removing the humidifying filter (Rotor) from the water tank part.
- Disassemble the humidifying filter (Rotor).
- Wipe it with a soft sponge after soaking it in water.
- Assemble the humidifying filter (Rotor): Insert the filter into the groove of the axis. Close the filter after inserting the right board into the axis.
[How to clean up humidifying filter]:
- If stains are not removed, soak the filter for 3 hours in tepid water (less than 40°C) mixed with neutral detergent. Rinse thoroughly with clean water. Do not boil or wash in boiling water, as this can deform the product.
- If water scum is difficult to remove from the evaporative filter, wash the filter with citric acid. Mix approximately 30g (3 large spoons) of citric acid in 1.5 liters of warm water.
- After installing the humidifying filter (Rotor) into the water bassin, install the water tank and water tank cover into the body frame. Ensure the water tank part is correctly installed.
Troubleshooting
If you suspect an error, perform the checks below. If the issue persists, stop using the unit, unplug it, and contact customer service. Do not attempt self-repair.
Case | Check as follows | Reference Page |
---|---|---|
Not working | Is the plug inserted into the electrical outlet? | 21P |
Is the water tank part installed correctly? Ensure it is installed. | 15P, 13P, 21P | |
Is the 'no water' lamp on? Ensure the water tank is filled with water. | 21P, 13P | |
Turning the lamp for complementing water on | Is the water tank containing water? Fill the water tank with water. | 21P |
Is the water tank part missing? Insert the water tank part completely. | 21P, 13P | |
Is the sensor of water level missing? Install the sensor of water level. | 12P | |
Leaking water | Is the cap of the water tank closed properly? Check the water tank cap. | 19~22P |
Is the body frame tilted? Use the body frame on a flat surface. | 12P | |
Inside water tank staining with powder | This is material accumulated from dirt or hard substances due to long-term use. Ensure regular cleaning. | 19~22P |
Sounding operation even in stopping condition | Is a splashing sound heard? This comes from the water tank when filling it with water (this is not an error). | 14P |
A little humidity | If indoor humidity is high or the temperature is low, humidity output can be reduced. | 14P |
Is the air filter blocked? Clean the filter according to the instructions. | 19P | |
You may perceive low humidity when using the unit in a spacious room. | 14P |
Environmental Information
This product must not be disposed of with normal household waste at the end of its life. It must be brought to a collection point for the recycling of electrical and electronic equipment. The symbol on the product, instruction manual, or packaging indicates this.
The materials are reusable according to their labeling. By recycling, material recycling, or other forms of utilizing old devices, you make an important contribution to protecting our environment. Please inquire at the local town hall for the appropriate disposal center.
Service and Warranty
Clean Air Optima ensures your airwasher against defects in materials and/or workmanship for up to two years after the initial purchase. If material or manufacturing faults occur, they will be resolved by Clean Air Optima, or Clean Air Optima will provide a replacement device with the same or better properties.
The guarantee covers any damage caused by carelessness in handling, accidents, abuse, lack of cleaning and maintenance, or other uses not compatible with the information in these instructions. General commercial law also applies.
In case of failure, it is recommended to return the instrument along with the original sales receipt and a brief description of the defect found. Contact your supplier, or if that is not possible, contact Clean Air Optima.
If the defect is not related to material and/or workmanship, processing or repair costs will be charged.
Contact Information:
- Company: Clean Air Optima Germany GmbH
- Address: Enschedestraße 14, 48529 Nordhorn, Germany
- Email: info@optima-luftreiniger.de
- Website: www.optima-luftreiniger.de