u-blox Product Change Note

Topic: TOBY/MPCI-L201-02S, TOBY-L200-03S, TOBY-L210-03S, TOBY-L280-03S

Document Information

Document ID: UBX-19000820

Author: Drazen Drinic

Date: 12-Apr-2019

Copyright © u-blox AG.

Copying, reproduction, modification or disclosure to third parties of this document or any part thereof is only permitted with the express written permission of u-blox. The information contained herein is provided "as is" and u-blox assumes no liability for its use. No warranty, either express or implied, is given, including but not limited, with respect to the accuracy, correctness, reliability and fitness for a particular purpose of the information. This document may be revised by u-blox at any time. For most recent documents, visit www.u-blox.com.

1 Affected Products

Product Name Order Code Type No (Old) Type No (New)
TOBY-L201 TOBY-L201-02S TOBY-L201-02S-00 TOBY-L201-02S-01
TOBY-L200 TOBY-L200-03S TOBY-L200-03S-00 TOBY-L200-03S-01
TOBY-L210 TOBY-L210-03S TOBY-L210-03S-00 TOBY-L210-03S-01
TOBY-L280 TOBY-L280-03S TOBY-L280-03S-00 TOBY-L280-03S-01
MPCI-L201 MPCI-L201-02S MPCI-L201-02S-00 MPCI-L201-02S-01

2 Type of Change

3 Description of Change

Component suppliers have announced end of life (EOL) for specific components currently used in TOBY-L2 products (Power Amplifier operating on Band 17, Band 20 and memory component). u-blox has introduced changes with new product type numbers to ensure TOBY-L2 product availability. The products with new type numbers include new firmware and hardware versions.

Hardware Changes Description

Description of the hardware changes in each type number:

Old Type Number New Type Number Description of HW Changes
TOBY-L201-02S-00 TOBY-L201-02S-01 Single band power amplifier LTE FDD B17 replaced with another PA electrically equivalent. System memory replaced with another equivalent memory component. Copper balance introduced to improve PCB coplanarity.
TOBY-L200-03S-00 TOBY-L200-03S-01 Single band power amplifier LTE FDD B17 replaced with another PA electrically equivalent. System memory replaced with another equivalent memory component. Copper balance introduced to improve PCB coplanarity.
TOBY-L210-03S-00 TOBY-L210-03S-01 Single band power amplifier LTE FDD B20 replaced with another PA electrically equivalent. System memory replaced with another equivalent memory component. Copper balance introduced to improve PCB coplanarity.
TOBY-L280-03S-00 TOBY-L280-03S-01 System memory replaced with another equivalent memory component. Copper balance introduced to improve PCB coplanarity.
MPCI-L201-02S-00 MPCI-L201-02S-01 Single band power amplifier LTE FDD B17 replaced with another PA electrically equivalent. System memory replaced with another equivalent memory component.

The firmware of the module has been updated in order to support the alternative components. The firmware appropriately configures and controls the components to ensure full compatibility in the general operations of the module.

The version of firmware can be identified according to the type number as follows:

Old Type Number Current Firmware Version New Type Number New Firmware Version
TOBY-L201-02S-00 For AT&T: Modem: 09.93
Application: A02.50
For VZW: Modem: 09.94
Application: A01.02
TOBY-L201-02S-01 For AT&T: Modem: 20.03
Application: A01.02
For VZW: Modem: 20.03
Application: A01.02
TOBY-L200-03S-00 Modem: 15.90
Application: A01.50
TOBY-L200-03S-01 Modem: 16.19
Application: A01.02
TOBY-L210-03S-00 Modem: 15.63
Application: A01.50
TOBY-L210-03S-01 Modem: 16.19
Application: A01.02
TOBY-L280-03S-00 Modem: 15.63
Application: A01.50
TOBY-L280-03S-01 Modem: 16.19
Application: A01.02
MPCI-L201-02S-00 For AT&T: Modem: 09.93
Application: A02.50
For VZW: Modem: 09.94
Application: A01.02
MPCI-L201-02S-01 For AT&T: Modem: 20.03
Application: A01.02
For VZW: Modem: 20.03
Application: A01.02

For full details of changes contained in this new version, see Annex A.

The modem and application version can be polled from the module by sending AT+GMR and ATI9 commands. See u-blox AT commands manual [1] for details.

4 Schedule

Estimated First Shipment Date: 23. Dec 2019

5 Customer Impact and Recommended Action

u-blox has taken utmost care to ensure full backward compatibility to the previous versions. Successor products are pin-to-pin compatible to its predecessor.

Modules with the old type number can be upgraded with new firmware version. New Firmware can be downloaded to the TOBY-L2 module using serial interface USB/ UART or over the Air (FOTA).

After old type numbers have been upgraded with the new firmware version, downgrading to old firmware is no longer possible.

Certifications and approvals available for predecessor products (with old type numbers) are also achieved for the successor products (new type numbers) [A.2].

PTCRB / GCF certification grants have been updated. Customers shall align their products to the updated versions. For example on the PTCRB/GCF website, the customer shall select the new listed version of the u-blox module and submit request; no testing is expected.

For country approvals, u-blox recommends that customers contact their preferred certification body to verify if any action is needed. For example FCC and ISED have been updated, but maintain the same IDs; no action is needed if the same module ID is re-used. RED customers shall update their Technical Documentation using data relevant for the new type number.

Operator approvals have been updated. Please check with your contact at the operator to find out what is needed to align to the updated versions; no testing is expected.

Note that any new operator certification shall be initiated using the latest type number.

6 Known bugs and limitations

See TOBY-L201-02S IP Information Note [2], TOBY-L200/210/280-03S IP Information Note [3].

7 Reference Documents

Annex A: Description of changes

A.1 Firmware

A.1.1 New features

  • [CA-038135]: Enable DHCP in bridge mode¹
    AT command update: +UBMCONF (<networking_mode>=2)
  • [FEAT-54] Security features:
    • Password protected storage
    • Firmware and Firmware signature encryption
      New AT command: +USECCFG
    • Transport Layer Security - TLS 1.2
    • Certificate pinning with parameters configuration, random IV generation and additional AES cyphering algorithm
      New AT command: AT+USECPRF=<pid>,12,<srv_cert>,<pining_level>
    • HTTPS for FOTA
    • Ciphering - ECDHE-RSA-AES128-GCM-SHA256
  • [u-blox ID 1-2457] TOBY/MPCI-L201 - certified against Dec 2018 Verizon requirements (IMS roaming, new Class 6 and Class 7 APN requirements, Class 1 APN network set to IMS, OMA DM nodes to be persistent after power cycle, data retry test cases 2.1 fixed on latest test script on R&S)
  • TOBY-L200, TOBY-L201 - certified against AT&T requirements
    • [u-blox ID 1-2547] enabled IPv6 support
    • [u-blox ID 1-2542] enabled BIP support on TOBY-L201 (aligned to TOBY-L200)
  • [u-blox ID 1-2379] Enabled automatic NITZ update of system clock on TOBY-L201

¹ Not applicable to TOBY/MPCI-L201

A.1.2 Changes and issues fixed² implemented on application level

  • [CA-038557 / u-blox ID 2-2838] If triggered and failed due to entrance into out of service, the EPS bearer deactivation required by +CGACT is not effective in NAS despite it is confirmed at AT interface.
  • [CA-038915 / u-blox ID 2-2840] The +COLP URC is not meaningful when the connected line identity is not available (e.g. due to interworking or presentation restrictions).
  • [CA-040298, CA-039773 / u-blox ID 2-2948, 1-2606] RNDIS may not work if linux Kernel version is higher than v.4.8 and RNDIS driver optimization is enabled via AT+UDCONF=67,1.
  • [CA-034663 / u-blox ID 2-2823] The flow control might not work correctly with clients slowly processing downlink data coming from Direct Link.
  • [CA-040611 / u-blox ID 2-2701] UDP packet might not sent out with TOBY-L210.
  • [CA-042115 / u-blox ID 2-2859] Error sending stored SMS to international number using +CMSS.
  • [CA-033918, CA-015312 / u-blox ID 2-2467] New feature AT+UDCONF=9,2: disable uplink packet filter in Bridge mode.
  • [CA-040785 / u-blox ID 2-2857] In case of multiple EPS bearers/PDP context with different DNS, it might not be possible to resolve a hostname via DNS.
  • [CA-042913 / u-blox ID 2-2875, 1-2476] After sending AT+CMGL=0 the module resets if the SMS are listed in more than 20 s due to e.g. their large number.
  • [CA-042841 / u-blox ID 2-2872] If there is no PDP context active the action command AT+CGCONTRDP blocks the AT interface for 5 minutes.
  • [CA-048725 / u-blox ID 2-3035] The module can reset when removing antenna due to wrong handling of system information message at service recovery.
  • [CA-055879 / u-blox ID 2-3082] DCS value in +CMGR in text format is wrong for UCS2 encoded messages. (CL1 is OK).
  • [CA-042553 / u-blox ID 2-2990, 2-3064, 2-3065, 2-3259] Unexpected behavior of the module TOBY-L210 in P3 testing (M2M_009, M2M_011, M2M_012, M2M_068, M2M_072).
  • [CA-050538 / u-blox ID 1-2628] The module can reset when VZW +UMNOCONF configuration is changed (e.g. from IMS test mode to default one).
  • [CA-058962 / u-blox ID 2-2701] The +USOCO AT command might return an error result code.
  • [u-blox ID 1-2031] In VZW configuration: use AT+CFUN=16 in case of IMS registration issues, use AT+CFUN=1,1 instead of AT+CFUN=1 to exit the airplane mode.
  • [u-blox ID 1-2123] In VZW configuration: the IMS client is not properly restarted after a SIM refresh (the first time a new SIM is inserted) SMS over IMS will not work.
  • [u-blox ID 1-2391] The sequence AT+CFUN=19/ AT+CFUN=1 shall not be used when in +COPS: 2.

² For each change and bug, the external and the internal references are reported with this notation [external reference / u-blox reference]

A.1.3 Known limitations

  • [u-blox ID 1-2402] AT+CFUN=4,1 causes IMS to not restart. Workaround: send the command: AT+UIMSCONF="KEY_UIMSRESET",1 which triggers IMS to start back and also resets the +CIREG URC status to 0.
  • [u-blox ID 1-2390] The "operation not allowed" error result code is sometimes returned as "Operation not allowed", they are the same error.
  • [u-blox ID 2-2163 / u-blox ID 1-2226] After the +CFUN=19/1 cycle, the +UUICC read command returns "SIM not inserted" until the SIM is initialized.
  • [u-blox ID 1-2105] In VZW configuration +UMNOCONF: 3,7, the following settings are not stored in NVM after SW reset +CGSMS and "KEY_MO_SMS_FORMAT" (+UIMSCONF AT commands key).
  • [u-blox ID 1-2078] In VZW configuration: when a SMS is stored in "SM" memory in text mode (AT+CMGF=1), the <scts> field does not contain the value of the service center time stamp. Workaround: use the PDU mode (AT+CMGF=0).
  • [u-blox ID 1-2076] Do not close the MUX ports immediately after the termination of a dial-up. It is recommended to wait 3 s.
  • [u-blox ID 2-728 / u-blox ID 1-1920] All the MUX ports shall be opened simultaneously.
  • [u-blox ID 1-2030] During PPP startup some unexpected strings may be sent by the module. Workaround: ignore these strings.
  • [u-blox ID 1-1996] The preferred operator list command (+CPOL) is not available in +COPS: 2.
  • [u-blox ID 1-1980] In +UCGED the LTE indicators <mmeGrId> and <mmeCode> may be wrong.
  • [u-blox ID 1-1928] Use +CESQ for RSSi level indication in LTE RAT instead of +CIEV.
  • [u-blox ID 1-1911] Wrong +UUSORF indication when there are more packets to read available. The URC notifies only the size of next available packet to read.
  • [u-blox ID 1-1906] Downloading a file in the file system at high baudrate (921600 b/s) can lead to data corruption. Workaround: decrease the UART baudrate to 115200 b/s.
  • [u-blox ID 1-1870] The +CMGW and +CMSS AT commands shall not be used on VZW network. Workaround: use +CMGS instead.
  • [u-blox ID 1-1188] After deleting a PDP context with +CGDEL, if the context is later re-defined, all previously existing associated data (QoS profiles, TFTs) will reappear.
  • [u-blox ID 1-804] The +URAT preferred values are not always respected when the setting is done with the sequence +COPS=2, +URAT, +COPS=0. Workaround: use the sequence +CFUN=4, +URAT, +CFUN=1.

A.2 Certifications

FCC and ISED certification number remain unchanged between old and new type number.

Two additional certifications are achieved:

Overview of certification scheme for new type number.

Certification Scheme TOBY-L200-03S-01 TOBY-L201-02S-01 TOBY-L210-03S-01 TOBY-L280-03S-01
GCF
PTCRB
CE Europe
FCC United States
FCC identification number XPYTOBYL200 XPYTOBYL201 XPYTOBYL210 XPYTOBYL280
ISED Canada
ISED certification number 8595A-TOBYL200 8595A-TOBYL201 8595A-TOBYL210 8595A-TOBYL280
ANATEL Brazil
RCM Australia
NCC Taiwan
IFT Mexico X
AT&T
Verizon
Deutsche Telekom X
Rogers X

X - New certifications achieved with TOBY-L200-03S-01 and TOBY-L210-03S-01

Note: KCC certifications on TOBY-L210 are not renewed.

MPCI-L201-02S-01 certifications are: GCF, FCC, ISED, Verizon.

A.3 AT commands update

PDF preview unavailable. Download the PDF instead.

TOBY-L2-MPCI-L2 PCN (UBX-19000820) Microsoft Word 2013

Related Documents

Preview u-blox EVK-L2 User Guide: TOBY-L2 Series LTE/DC-HSPA+/EGPRS Cellular Evaluation Kits
This guide provides comprehensive instructions for setting up and evaluating the u-blox EVK-L2 evaluation kits, which feature the TOBY-L2 series LTE/DC-HSPA+/EGPRS cellular modules. It covers board setup, software installation, AT command usage, internet browsing configurations for Windows and Linux, and current consumption measurement procedures.
Preview u-blox TOBY-L210-03A Firmware Update and Hardware Modification Details
This document provides detailed information on the product changes for the u-blox TOBY-L210-03A cellular module, including firmware updates, hardware modifications, customer impact, and updated AT commands. It covers new features, fixed issues, and certifications.
Preview u-blox SARA-R4 Series: Firmware Update Guide with uFOTA, FOAT, and EasyFlash
This application note provides a comprehensive guide to updating firmware for u-blox SARA-R4 series cellular modules. It details methods such as Firmware Over-The-Air (FOTA) via uFOTA server, tethered updates via Firmware Over AT command (FOAT), and direct flashing using the EasyFlash tool. The document covers procedures, AT commands, system architecture, and important considerations for seamless firmware management.
Preview u-blox 6 Protocol Specification: Power Save Mode Restriction Update
Technical information note (UBX-TN-11075) from u-blox detailing a new restriction in the 'Power save mode' section of the u-blox 6 protocol specification, including affected products, type of change, description, schedule, customer impact, and reference documents.
Preview LARA-R6-L6 Series Application Development Guide - AT Commands & Integration
Comprehensive guide for developers on using u-blox LARA-R6 and LARA-L6 cellular modules, covering AT commands, cellular technologies, application design, and connectivity.
Preview u-blox ZED-F9R HPS1.00 Release Note
Release note for the u-blox ZED-F9R module with HPS 1.00 firmware, detailing features, supported GNSS constellations, message interfaces, and known limitations.
Preview u-blox NEO-M8M and NEO-M8Q ROM Firmware Upgrade Notification
Product Change Notification (PCN) regarding the ROM firmware upgrade for u-blox NEO-M8M and NEO-M8Q modules. Details the change to ROM SPG 3.01, affected products, schedule, and customer impact.
Preview u-blox Product Catalog: Cellular, Short Range Wireless, and Positioning Solutions
Explore the u-blox product catalog featuring cellular modules, short-range wireless solutions, and positioning modules. Discover advanced technologies for smart cities, Industry 4.0, automotive, wearables, smart homes, mobility, and healthcare.