RUCKUS R670 Access Point Quick Setup Guide
Brand: RUCKUS (CommScope)
Introduction
This Quick Setup Guide provides step-by-step instructions on how to install and begin using your RUCKUS R670 tri-band 802.11be Wi-Fi 7 indoor Wi-Fi access point (AP).
Note: The minimum software version for the R670 AP is SmartZone (SZ) 7.0 or later.
FIGURE 1 R670 Access Point: Top View
Diagram showing the top view of the R670 Access Point, highlighting ventilation grills and its overall shape.
Other Languages
This guide is also available in the following languages:
Before You Begin
Before deploying RUCKUS products, please check for the latest software and release documentation.
- Release Notes and other user documentation are available at support.ruckuswireless.com/documents.
- Software upgrades are available at support.ruckuswireless.com/software.
- Software license and limited warranty information are available at support.ruckuswireless.com/warranty.
Before deploying your RUCKUS Access Point, verify that all items listed in Package Contents are included. If any item is damaged or missing, notify your authorized RUCKUS sales representative. Ensure you have the required hardware and tools.
RUCKUS WLAN Configuration for 6GHz APs
For configuring a 6GHz WLAN, download the RUCKUS Solo APs Configuration Guide - 6 GHz Radio Configuration Using CLI from https://support.ruckuswireless.com/documents/4017 for reference.
Package Contents
A complete R670 installation package includes all of the following items:
- R670 Access Point
- One T-bar mounting bracket
- Four T-bar mounting clips
- Two #6 x 0.75-in. long plastic wall anchors
- Two #8 x 1.0-in. long metal screws
- One 66-mm long unit removal pin
- Declaration of Conformity/Regulatory flyer
Required Hardware and Tools
Required hardware:
- Admin PC (computer with an Ethernet port and Wi-Fi adapter)
- CAT 5e (or better) Ethernet cable
- RUCKUS 48 VDC power adapter (902-1170-XX00) (sold separately) or 802.3at/bt-compliant Power over Ethernet (PoE) switch or PoE injector (902-1180-XX00)
Required installation tools for mounting on a flat surface using factory-supplied screws and anchors:
- An electric drill with a 4.75-mm (3/16-in.) drill bit
- Phillips-head screwdriver
Optional hardware and tools:
- Customer-ordered RUCKUS secure mounting bracket kit (902-0120-0000):
- If mounting on a flat surface using the secure mounting bracket kit, you need an electric drill with a 4.75-mm (3/16-in.) drill bit.
- If mounting on a pipe or pole using the secure mounting bracket kit, you will also need a 38.1-mm to 63.5-mm (1.5-in. to 2.5-in.) pipe or pole, two pole clamps, and hand tools to tighten the clamps.
Step 1: Connecting Your Computer to the AP
Note: The AP enters a low power mode during transition while booting.
- If DC powered, connect your computer network port to the PoE port on the AP using an Ethernet cable. Refer to Figure 2.
- Connect the AC cable of the DC power adapter to a convenient and protected power source. Connect the DC output cable of the DC power adapter to the 48 VDC port on the AP.
- a. Connect the AP to a switch port.
- b. Connect the computer to another switch port and manually assign an IP address to configure the AP.
- Verify that the LED on the AP is blinking amber (may also be in a green state if a WLAN has been configured).
Note: Alternatively, connect the AP PoE port to a PoE injector or switch for both power and network connectivity. Connect your computer network port to the data port of the PoE Injector or to another port of the switch.
Note: In general, switches must have the Link Layer Discovery Protocol (LLDP) enabled. The PoE switch port must run LLDP and Power over Ethernet/MDI (BT5) for the R670 AP to operate in full-power mode.
Note: To configure the AP, connect the computer to another switch port and manually assign an IP address in the same subnet as the default management IP address that is depicted on the AP's label.
Note: Alternatively, connect the computer and the AP with a basic PoE switch in the following ways:
FIGURE 2 R670 AP Ports on the Bottom Panel
Diagram showing the bottom panel of the R670 Access Point, labeling the ports: 1. USB, 2. Reset, 3. 1G ETH, 4. 5G ETH PoE, 5. 48 VDC.
TABLE 1 R670 AP Ports
No. | Label | Description |
---|---|---|
1 | USB | USB port • Interface: USB 2.0 • Connector: USB - Type-A plug |
2 | Reset | Reset button can be accessed using a rigid, thin wire (such as a straightened paperclip) or the factory-supplied 66-mm unit removal pin. • Soft reset: Press and hold less than 4 seconds. • Factory reset: Press and hold more than 5 seconds and less than 15 seconds. The LED will alternate red and green. • Recovery mode with factory defaults: Press and hold more than 15 seconds. The LED will alternate between red and amber once before the AP reboots. |
3 | 1G ETH | 10/100/1000 Mbps port: RJ-45 Ethernet port (non-PoE) |
4 | 5G ETH PoE | 100/1000/2500/5000 Mbps PoE In port: RJ-45 Ethernet port (supports High Power 802.3bt PoE) |
5 | 48 VDC | 48 VDC input |
LED Signals
The LED on the AP has several color states that determine the various states of the AP. The following table provides a high-level description of each color that may appear on the AP.
TABLE 2 R670 LED Signals
Color | Description |
---|---|
Red | The AP is receiving power and is booting up its firmware. If the AP is cycling between Red and another color, the AP is proceeding with a factory reset process. |
Amber | The AP is booting up software services. These software services include loading the controller and loading a new configuration or firmware update. This color also denotes if there are issues with either the network gateway or controller. |
Green | The AP has finished booting up software services and there are no issues with connectivity or controller management. |
Step 2: Preparing Your Computer for AP Setup
Note: The following procedures assume Windows 10 or Windows 11 as the operating system. Procedures for other operating systems are similar.
- On your Windows PC, navigate to Start > Settings > Network and Internet > Ethernet.
- Click the Edit button next to the IP assignment section to set a static IP address.
- In the Edit IP settings dialog box, change the setting from Automatic (DHCP) to Manual using the drop-down menu.
- Toggle the IPv4 switch to On and enter the following fields:
- IP address:
192.168.0.22
(or any available address in the 192.168.0.x network, except 192.168.0.1) - Subnet mask:
255.255.255.0
(if prompted for Subnet prefix length, enter 24) - Default gateway:
192.168.0.1
- IP address:
- Click Save to save your changes. Your changes go into effect immediately.
Note: Make a note of the currently active settings so you can restore your computer to its current configuration later when the setup process is complete.
Step 3: Logging In to the AP
Note: The admin PC must be directly connected to the AP through one of the Ethernet ports and powered on, ready for setup.
- On your admin PC, open a web browser window.
- Enter the following URL in the browser navigation bar:
https://192.168.0.1
- Press Enter to initiate the connection. When the security alert dialog box displays, click OK/Yes to proceed.
- When the RUCKUS Admin login page displays, enter the following information:
- Username:
super
- Password:
sp-admin
- Username:
- Click Login. On your first login, you will be prompted to change the default password.
- When the Change Password dialog box displays, enter the following information:
- New Password: Enter a new password.
- Confirm Password: Re-enter the new password.
- Click Submit.
- Log in using the new password.
Step 4: Customizing the Wireless Settings
The AP has default wireless settings to facilitate plug-and-play operation. Customize the 6GHz configuration using the CLI (refer to RUCKUS WLAN Configuration for 6GHz APs on page 1). Customize the 2.4GHz and 5GHz configurations through the web browser UI as follows.
TABLE 3 Default AP Settings
Settings | Band | Default |
---|---|---|
Network Names (SSIDs) | 2.4G | wlan0 - 7 Wireless1 - Wireless8 |
5G | wlan8 - 15 Wireless9 - Wireless16 |
|
6G | wlan16 - 23 Wireless17 - Wireless24 |
|
Security (Encryption method) | 2.4G | WEP, WPA2, WPA+WPA2* |
5G | WEP, WPA2, WPA+WPA2* | |
6G | WPA3 (OWE, SAE) | |
Default Management IP Address | 192.168.0.1 |
Note: * WPA3 and WPA2+WPA3 are additional options in the CLI.
Note: By default, IoT radios on standalone APs are disabled. To enable them, you need to configure the AP in the RUCKUS IoT Controller, refer to RUCKUS IoT Controller Configuration Guide.
- On the web interface menu, click Configuration > Radio 2.4G or Configuration > Radio 5G. The Configure > Wireless > Common page is displayed.
- Verify that the following options are active:
- Channel: SmartSelect
- Country Code: If you are not located in the United States of America, select your current country.
- Click Update Settings if you made any changes.
- Click any of the Wireless # (Wireless LAN Number) tabs at the top of the page.
- In Wireless Availability, click Enabled.
- Delete the text in the SSID field, and enter a name for your network that will help your users identify this AP in their wireless network application.
- Click Update Settings to save your changes.
- Repeat for each Wireless # (Wireless LAN Number) interface that you want to enable.
- Click Logout to exit the web interface.
- When the Ruckus Admin login page displays, exit your browser.
- Disconnect the AP from the computer and from the power source, and restore your computer to its original network connection configuration settings.
Note: The 6GHz option must be configured only using the CLI command. The GUI does not support this option. Refer to RUCKUS WLAN Configuration for 6GHz APs on page 1 for more information.
Step 5: Placing the AP in Your Site
1. Move the AP to its permanent location (accessible to both power and network connections). For installation instructions, refer to Mounting Instructions on page 3. A site survey must have been performed to assess optimum AP placement.
2. Use an Ethernet cable to connect the PoE port to an appropriate device:
- The network device of the ISP or carrier
- An Ethernet switch that is connected to the network device of the ISP or carrier
Or
Connect the AP power adapter (or PoE power supply) to the AP, and connect to a convenient power source.
Note: If you will be using PoE, you must use a CAT 5e (or better) Ethernet cable to connect the AP to the PoE switch or PoE injector. PoE injector, model 740-64310-001, supports 1, 2.5, 5.0 and 10 Gbps.
3. Verify that the PoE port LED is lit.
After a short pause to re-establish the Internet connection, you can test the AP.
Step 6: Verifying the Installation
- Using any wireless-enabled computer or mobile device, search for and select the wireless network you previously configured.
- When connected, open a browser and connect to any public website.
Mounting Instructions
Mounting on a Drop-Ceiling T-Bar
The factory-supplied T-bar mounting assembly kit allows you to attach the AP to recessed and flush drop-ceiling T-bars.
- Position the studs on the bottom of the T-bar bracket (1 in Figure 3) in the keyholes on the AP enclosure (2 in Figure 3).
- Slide the T-bar bracket away from the Ethernet ports on the bottom of the AP until the AP retainer tab snaps into place, trapping the T-bar bracket studs in the keyholes (2 in Figure 3).
FIGURE 3 Attaching the T-bar Bracket to the AP
Diagram illustrating the attachment of the T-bar bracket to the R670 Access Point enclosure. It shows studs on the bracket fitting into keyholes on the AP, and a locking tab securing the bracket.
- Insert the locking tab (3 in Figure 3) so it is in the first position on the T-bar bracket.
- Gently push the ceiling tiles, if present, up and out of the way.
- Position the T-bar bracket so its two clasps grip one edge of the T-bar (1 in Figure 4). Make sure that both clasps are gripping the T-bar.
- Hold the AP in place and gently push the opposing locking tab (1 in Figure 4) until its clasp grips the other edge of the T-bar. Make sure that all four clasps are gripping the T-bar.
Note: Ensure that the center line of the bracket body is aligned with the center line of the T-bar.
FIGURE 4 Attaching the T-bar Bracket to the T-bar
Diagram showing the T-bar bracket being attached to a ceiling T-bar. It depicts the bracket's clasps gripping the edge of the T-bar.
Mounting on a Flat Surface
The factory-supplied mounting screws and plastic wall anchors allow you to attach the AP to a wall or other flat surface.
- Use the Mounting Template on the last page of this Quick Setup Guide to mark the locations for two drill holes on the mounting surface.
- Use a 4.75-mm (3/16-in.) drill bit to drill holes approximately 25 mm (1 inch) deep into the mounting surface.
- Insert the factory-supplied anchors (2 in Figure 5) and mounting screws (1 in Figure 5) into the mounting surface, leaving approximately 6 mm (0.25 inch) of the screw heads protruding for the AP enclosure keyholes.
FIGURE 5 Flat Surface Mounting
Diagram illustrating flat surface mounting for the R670 Access Point. It shows screws and anchors being used to attach the AP to a wall or flat surface.
- Place the AP onto the mounting screws so the screw heads enter the keyholes on the AP enclosure, and push the AP down until the AP retainer tab snaps into place.
Cautions and Notices
A caution calls your attention to a possible hazard that can damage equipment.
CAUTION! The equipment is intended for installation in a Restricted Access Location.
CAUTION! The equipment can be connected to PoE networks without routing to the outside plant.
Note: The 6GHz radio option is not allowed for use in China.
For More Information
For information on how to configure and manage the AP, refer to the RUCKUS Indoor Access Point User Guide, available from http://docs.commscope.com/?docs-box.
For the product data sheet, refer to https://www.ruckusnetworks.com/products/wireless-access-points/.
RUCKUS, Inc. is a wholly owned subsidiary of CommScope, Inc.
© 2024 CommScope, Inc. All rights reserved. CommScope and the CommScope logo are registered trademarks of CommScope and/or its affiliates in the U.S. and other countries. For additional trademark information see https://www.commscope.com/trademarks. All product names, trademarks, and registered trademarks are the property of their respective owners.