COMMAX CDL-200P/200R USER MANUAL

Durable Door lock without worry about A/S

Key Features

Products Specifications and Components

NoNameSpecifications
1Battery coverProtects batteries and registration button.
2Opening methodRF key, Password, Interlocking pack (optional)
3Registration buttonUsed to register or change password or smart key.
4MortiseDead bolt, Latch bolt
5Alkaline AA batteryPower source (8 x AA batteries, separate purchase).
6Antenna powerWireless devices for safety systems (optional) 447.275Mhz
7Out bodyAL,ZN,ABS,PC
8In bodyAL,ZN,ABS,PC
9Mortise & StrickerOption 1: Mortise Type, Option 2: Big Mortise Type
10Installation instructionUser manual, Batteries, Construction diagram, Smart key (Key formula only)

Indoor Names and Functions

NoNameSpecifications
1Password4-12 digits (Up to 4 can be registered)
2RF keyCan register within 30
3Wallpad interlockOptional (CDL-447)
4Rated voltageDC 6V
5Emergency powerDC 9V
6Type of productCDL-200PSKF, CDL-200PSNF
7RFIDUsing frequency: 13.56Mhz, Modulation format: ASK
8Wireless devices for safety systems447.275Mhz, FSK, 10mW/under

Outdoor Names and Functions

NoNameSpecifications
1Name boardEnter numbers for registration/password change.
2Battery warning lightAudible alarm at low voltage.
3Smart key input unitRecognizes smart keys for door opening.
4Emergency holeKey formula only (CDL-200PSKF).
5Outdoor handleOpens/closes doors from outdoors.
6Emergency power terminalConnects a 9V battery for power when main batteries are discharged.

How to Register and Change Password

  1. Press the [registration] button.
  2. Press the [1] button on the outdoor number plate.
  3. Enter the new password (4-12 digits) and press the [*] button. A confirmation tone will sound. Press [*] again to complete registration.

Reference: Up to 4 passwords can be registered. Registering a new password deletes existing ones.

Caution: Do not use consecutive numbers for your password.

How to Register the Linker (Optional)

  1. Press the [registration] button.
  2. Press the [3] button on the outdoor number plate.
  3. Press the [Register] or [OP / CL] button on the linker.

Reference: Up to 5 interlocks can be registered.

How to Set and Dismiss 3D Touch

  1. Press the [Registration] button on the outdoor side body to turn the 3D touch function on or off.

Reference: 3D touch mode is off by default. It enhances password security by using virtual numbers. When 3D touch mode is released, the password resets to "1234".

Caution: In case of master registration/deletion or fire/accident, it reverts to normal number mode.

How to Register Smart Key

When registering or re-registering smart keys, all existing smart keys must be registered at once.

  1. Press the [registration] button.
  2. Press the [2] button on the outdoor number plate.
  3. Touch the smart key to the smart key input unit. A confirmation sound will be heard.
  4. Press the [Registration] button on the indoor side body to complete registration.

Reference: Up to 30 smart keys can be registered. Registering a new smart key deletes existing ones.

How to Delete Smart Key, Linker

  1. Press the [registration] button.
  2. Press the [7] button for smart key deletion or the [8] button for linker deletion on the number plate.
  3. Press and hold the [#] button for 5 seconds to delete registered smart keys or linkers.

How to Set Auto Lock, Manual Lock

Ensure the Mortise Square Lock on the indoor body is turned off.

Auto lock setting: Press the [4] button and then the register button. A confirmation tone will sound.

Manual lock setting: Press the [7] button and then the register button. A confirmation tone will sound.

Open the Door in Outdoor

Method 1: Open the door by password

  1. Touch the outdoor license plate to turn on the LED.
  2. Enter the registered password.
  3. Press the [#] button twice.

Method 2: Open door with smart key

  1. Touch the registered smart key to the smart key input unit.
  2. Open the door.

Method 3: Open door by interlocking (Optional)

  1. Press the [OP/CL] button on the interlock to open the door.

Door locking in indoor and outdoor

Set lock

Outdoor

Reference: Pressing the [double lock] button in manual lock mode will sound a "beep" to confirm the door is locked.

Internal double lock setting

This function prevents the door from being opened with a password or smart key from the outside.

Setting

  1. While the door is locked, press and hold the [double lock] button for 3 seconds. The setting is completed with an "OK" sound.

How to release internal double lock

  1. Push or pull the knob from inside to open the door.
  2. Press the [double lock] button inside and dismiss.
  3. Press the [Regist.] button.

Volume Adjustment

  1. Input password.
  2. Press the [#] button.
  3. Press [3] for volume up or [6] for volume down on the number plate.

Reference: Available in 8 volume levels. In sound pause mode, numbers flicker without sound.

Sound Pause Mode

Temporary silence function (1 time) regardless of the latest volume setting.

  1. Touch the number plate and press [#].
  2. Press [*] after the password or touch the card to open the door.

Reference: Sound returns to the original volume after the pause mode is operated once.

High Temperature Alarm

If extremely high temperature (60℃ ± 10℃) is detected, the lock automatically releases to open the door with a loud sound for user safety.

Emergency Power

When the door cannot be opened due to fully discharged batteries.

  1. Connect the terminals of a 9V battery to the emergency power outlet.
  2. Enter the password and press [*] to open the door while the 9V battery is connected.

Caution: Use a 9V battery (sold separately).

Emergency Key

Use when the door cannot be opened due to malfunction.

  1. Open the bottom cover of the outdoor body to access the mechanical key box.
  2. Insert and turn the mechanical key to open the door for emergency release.

Caution: It is recommended to store your mechanical key outside the door for emergency use.

Anti-mischief alert and 1 minute pause

If an unregistered password or smart key is used more than 5 times continuously, the operation freezes for 1 minute with an alert sound.

Door Open Alert during automatic lock setting

To inform the door open status during automatic lock setting, an alert sound rings twice with a 15-second interval if the door is opened.

Self-Diagnosis Table by each LED number flicking

Self-DiagnosisAction
Flicking ALL LEDs-Anti-mischief alert and 1 minute pause
Flicking LED number 2-Error on password, card
Flicking LED number 3Full of registered password, card
Flicking LED number 4Deadbolt Jam
Flicking LED number 5Burglar Alert
Flicking LED number 6Unregistered password, card
Flicking LED number 7Already registered address
Flicking LED number 8Fire Alarm
Flicking LED number 9Dual lock from Indoor unit
Flicking LED number 0Function

Factory Reset Mode

  1. Press the [Registration] button.
  2. Input "123578951" when the number plate lights on.
  3. Press the [#] button for 2 seconds.

Factory default mode is completed with a beep sound.

Caution: All settings revert to default after factory reset.

Battery Replacement Alert

If the battery alert light is on or a beep sounds, the batteries must be replaced. Replace all batteries with new ones at once.

Caution: Battery lifetime varies. Check batteries every 6 months. Wireless module activation may shorten battery life.

Deadbolt Jam alert

If the deadbolt is jammed during door open/close, an alert sound "bee bee bee bee" rings 3 times.

Caution: If the alert sound does not deactivate or the door lock malfunctions, the product's installation position may need adjustment. Contact your local installer or service provider.

Summary of how to use

This section provides a quick reference for common operations.

Models: CDL-200P, CDL-200R, CDL-200P Durable Door lock, Durable Door lock, Door lock, lock

File Info : application/pdf, 2 Pages, 14.73MB

PDF preview unavailable. Download the PDF instead.

COMMAX CDL-200P (01)

References

Adobe Illustrator(R) 15.0

Related Documents

Preview COMMAX CDL-400M/410M Series Digital Door Lock User Manual
Comprehensive user manual for the COMMAX CDL-400M, CDL-410M, CDL-400MC, and CDL-410MC digital door locks, covering product features, specifications, operation, and safety. Learn how to register passwords, smart keys, set auto locks, and utilize advanced security features.
Preview COMMAX CDL-400M/410M/400MC/410MC User Manual
User manual for COMMAX CDL-400M/410M/400MC/410MC digital door locks, covering features, installation, operation, and troubleshooting.
Preview COMMAX CDL-400M/410M/400MC/410MC User Manual
User manual for COMMAX CDL-400M, CDL-410M, CDL-400MC, and CDL-410M digital door locks. Covers features, installation, operation, and troubleshooting.
Preview How to Use the Commax CDV-70QT Video Door Phone: A Simple Manual
A concise guide on connecting and using the Commax CDV-70QT video door phone with your smartphone, including features like visitor calls, motion detection, and security settings.
Preview COMMAX DR-nUM / DR-nUS Door Station User Manual
User manual for the COMMAX DR-nUM and DR-nUS door stations, covering introduction, safety precautions, overview, operation methods, wiring, part lists, and specifications.
Preview COMMAX DR-2L Door Station User Manual
User manual for the COMMAX DR-2L Door Station unit, providing an overview, installation instructions, specifications, and operation details for this smart home security device.
Preview COMMAX CDV-70K User Manual: Color Video Door Phone
Comprehensive user manual for the COMMAX CDV-70K Color Video Door Phone, covering installation, operation, settings, safety precautions, and specifications.
Preview COMMAX DP-LA01M, LA01S Door Phone User Manual
User manual for COMMAX DP-LA01M and DP-LA01S door phones, covering warnings, overview, operation, wiring, and specifications. Includes information for the COMMAX DR-2K panel.