COMMAX CDL-200P/200R USER MANUAL
Durable Door lock without worry about A/S
Key Features
- Durable body of metal
- Auto lock/rewind/double lock function
- Use of 3D touch and imaginary function to secure password
- Password/Smart key can be registered multiple times
- Multi-level volume control / Selectable silence function
- Light button that is visible even in dark places
- Emergency power function (9V square battery)
- High-voltage protection/Fire protection/Anti-hack system
- Intuitive registration UI
Products Specifications and Components
No | Name | Specifications |
---|---|---|
1 | Battery cover | Protects batteries and registration button. |
2 | Opening method | RF key, Password, Interlocking pack (optional) |
3 | Registration button | Used to register or change password or smart key. |
4 | Mortise | Dead bolt, Latch bolt |
5 | Alkaline AA battery | Power source (8 x AA batteries, separate purchase). |
6 | Antenna power | Wireless devices for safety systems (optional) 447.275Mhz |
7 | Out body | AL,ZN,ABS,PC |
8 | In body | AL,ZN,ABS,PC |
9 | Mortise & Stricker | Option 1: Mortise Type, Option 2: Big Mortise Type |
10 | Installation instruction | User manual, Batteries, Construction diagram, Smart key (Key formula only) |
Indoor Names and Functions
No | Name | Specifications |
---|---|---|
1 | Password | 4-12 digits (Up to 4 can be registered) |
2 | RF key | Can register within 30 |
3 | Wallpad interlock | Optional (CDL-447) |
4 | Rated voltage | DC 6V |
5 | Emergency power | DC 9V |
6 | Type of product | CDL-200PSKF, CDL-200PSNF |
7 | RFID | Using frequency: 13.56Mhz, Modulation format: ASK |
8 | Wireless devices for safety systems | 447.275Mhz, FSK, 10mW/under |
Outdoor Names and Functions
No | Name | Specifications |
---|---|---|
1 | Name board | Enter numbers for registration/password change. |
2 | Battery warning light | Audible alarm at low voltage. |
3 | Smart key input unit | Recognizes smart keys for door opening. |
4 | Emergency hole | Key formula only (CDL-200PSKF). |
5 | Outdoor handle | Opens/closes doors from outdoors. |
6 | Emergency power terminal | Connects a 9V battery for power when main batteries are discharged. |
How to Register and Change Password
- Press the [registration] button.
- Press the [1] button on the outdoor number plate.
- Enter the new password (4-12 digits) and press the [*] button. A confirmation tone will sound. Press [*] again to complete registration.
Reference: Up to 4 passwords can be registered. Registering a new password deletes existing ones.
Caution: Do not use consecutive numbers for your password.
How to Register the Linker (Optional)
- Press the [registration] button.
- Press the [3] button on the outdoor number plate.
- Press the [Register] or [OP / CL] button on the linker.
Reference: Up to 5 interlocks can be registered.
How to Set and Dismiss 3D Touch
- Press the [Registration] button on the outdoor side body to turn the 3D touch function on or off.
Reference: 3D touch mode is off by default. It enhances password security by using virtual numbers. When 3D touch mode is released, the password resets to "1234".
Caution: In case of master registration/deletion or fire/accident, it reverts to normal number mode.
How to Register Smart Key
When registering or re-registering smart keys, all existing smart keys must be registered at once.
- Press the [registration] button.
- Press the [2] button on the outdoor number plate.
- Touch the smart key to the smart key input unit. A confirmation sound will be heard.
- Press the [Registration] button on the indoor side body to complete registration.
Reference: Up to 30 smart keys can be registered. Registering a new smart key deletes existing ones.
How to Delete Smart Key, Linker
- Press the [registration] button.
- Press the [7] button for smart key deletion or the [8] button for linker deletion on the number plate.
- Press and hold the [#] button for 5 seconds to delete registered smart keys or linkers.
How to Set Auto Lock, Manual Lock
Ensure the Mortise Square Lock on the indoor body is turned off.
Auto lock setting: Press the [4] button and then the register button. A confirmation tone will sound.
Manual lock setting: Press the [7] button and then the register button. A confirmation tone will sound.
Open the Door in Outdoor
Method 1: Open the door by password
- Touch the outdoor license plate to turn on the LED.
- Enter the registered password.
- Press the [#] button twice.
Method 2: Open door with smart key
- Touch the registered smart key to the smart key input unit.
- Open the door.
Method 3: Open door by interlocking (Optional)
- Press the [OP/CL] button on the interlock to open the door.
Door locking in indoor and outdoor
Set lock
- Auto lock: Automatically locked after 2 seconds after the door closes.
- Manual lock: Press the [double lock] button on the indoor side body.
Outdoor
- Auto lock: Locked automatically after 2 seconds after the door closes.
- Manual lock: Touch the number plate for 2 seconds.
Reference: Pressing the [double lock] button in manual lock mode will sound a "beep" to confirm the door is locked.
Internal double lock setting
This function prevents the door from being opened with a password or smart key from the outside.
Setting
- While the door is locked, press and hold the [double lock] button for 3 seconds. The setting is completed with an "OK" sound.
How to release internal double lock
- Push or pull the knob from inside to open the door.
- Press the [double lock] button inside and dismiss.
- Press the [Regist.] button.
Volume Adjustment
- Input password.
- Press the [#] button.
- Press [3] for volume up or [6] for volume down on the number plate.
Reference: Available in 8 volume levels. In sound pause mode, numbers flicker without sound.
Sound Pause Mode
Temporary silence function (1 time) regardless of the latest volume setting.
- Touch the number plate and press [#].
- Press [*] after the password or touch the card to open the door.
Reference: Sound returns to the original volume after the pause mode is operated once.
High Temperature Alarm
If extremely high temperature (60℃ ± 10℃) is detected, the lock automatically releases to open the door with a loud sound for user safety.
Emergency Power
When the door cannot be opened due to fully discharged batteries.
- Connect the terminals of a 9V battery to the emergency power outlet.
- Enter the password and press [*] to open the door while the 9V battery is connected.
Caution: Use a 9V battery (sold separately).
Emergency Key
Use when the door cannot be opened due to malfunction.
- Open the bottom cover of the outdoor body to access the mechanical key box.
- Insert and turn the mechanical key to open the door for emergency release.
Caution: It is recommended to store your mechanical key outside the door for emergency use.
Anti-mischief alert and 1 minute pause
If an unregistered password or smart key is used more than 5 times continuously, the operation freezes for 1 minute with an alert sound.
Door Open Alert during automatic lock setting
To inform the door open status during automatic lock setting, an alert sound rings twice with a 15-second interval if the door is opened.
Self-Diagnosis Table by each LED number flicking
Self-Diagnosis | Action |
---|---|
Flicking ALL LEDs | -Anti-mischief alert and 1 minute pause |
Flicking LED number 2 | -Error on password, card |
Flicking LED number 3 | Full of registered password, card |
Flicking LED number 4 | Deadbolt Jam |
Flicking LED number 5 | Burglar Alert |
Flicking LED number 6 | Unregistered password, card |
Flicking LED number 7 | Already registered address |
Flicking LED number 8 | Fire Alarm |
Flicking LED number 9 | Dual lock from Indoor unit |
Flicking LED number 0 | Function |
Factory Reset Mode
- Press the [Registration] button.
- Input "123578951" when the number plate lights on.
- Press the [#] button for 2 seconds.
Factory default mode is completed with a beep sound.
Caution: All settings revert to default after factory reset.
Battery Replacement Alert
If the battery alert light is on or a beep sounds, the batteries must be replaced. Replace all batteries with new ones at once.
Caution: Battery lifetime varies. Check batteries every 6 months. Wireless module activation may shorten battery life.
Deadbolt Jam alert
If the deadbolt is jammed during door open/close, an alert sound "bee bee bee bee" rings 3 times.
Caution: If the alert sound does not deactivate or the door lock malfunctions, the product's installation position may need adjustment. Contact your local installer or service provider.
Summary of how to use
This section provides a quick reference for common operations.
- Password Registration: [Registration] button → [1] button → Enter Password → [*] button
- Smart Key Registration: [Registration] button → [2] button → Touch Smart Key → [Registration] button (Indoor)
- Linker Registration: [Registration] button → [3] button → [Register] button on Linker
- Delete All Smart Keys: [Registration] button → [7] button → Hold [#] for 5 seconds
- Delete All Linkers: [Registration] button → [8] button → Hold [#] for 5 seconds
- Auto Lock Setting: [Registration] button → [4] button
- Manual Lock Setting: [Registration] button → [7] button
- Dual Authentication Mode: [Registration] button → [1] button
- Registration Authentication Mode: [Registration] button → [8] button
- 3D Touch Authentication Mode: [Registration] button → [0] button
- Volume Setting: Enter Password → [#] button → [3] (Up) or [6] (Down)
- Release Alarm Sound: Remove batteries (Indoor) or use Password/Card authentication (Outdoor).