Legrand Galion Double Pole Switch with Indicator - Product Environmental Profile

Brand: Legrand

Product Type: Double pole with indicator Switches

Legrand's Environmental Commitments

Legrand is committed to incorporating environmental management into its industrial sites, with over 85% of its global sites being ISO 14001-certified. The company strives to offer environmentally friendly solutions by developing innovative products that help customers design more energy-efficient and environmentally friendly installations. Legrand prioritizes the environment in product design, aiming to reduce the environmental impact of products throughout their lifecycle and provide customers with comprehensive information on composition, consumption, and end-of-life details.

Reference Product

Function: Establishes, supports, and interrupts the rated current 20AX and rated voltage 250V with an indicator, suitable for wall-mounted installation. Designed for a reference service life of 20 years.

Reference Product:

Cat.No: 282408

1 gang 1 way double pole switch 20A with amber LED power indicator and earth terminal.

The company reserves the right to change specifications and designs without notice. All illustrations, descriptions, dimensions and weights in the document are for guidance and cannot be held binding on the company.

Products Concerned

The environmental data presented is representative of the following products:

Constituent Materials

This Reference Product contains no substances prohibited by regulations applicable at the time of its introduction to the market. It respects the restrictions on the use of hazardous substances as defined in the RoHS directive 2011/65/EU, amended by delegated directive (EU) 2015/863 and its amendment 2017/2102/EU.

Description Total weight of Reference Product Product alone weight Packaging (alone)
Weight 0.12 kg (all packaging included) 0.09 kg 0.03 kg

Material Composition:

Category Percentage by Weight Details
Plastics 63.0% PC: 61.1%, PP: 1.2%, PE: 0.7%, PET: <0.1%
Metals 20.9% Steel: 11.4%, Copper and copper alloys: 4.7%, Silver alloys: <0.1%, Aluminium: <0.1%
Others 16.1% Electrical wire (high current): 0.7%, PWB < 10cm² (intermediate): <0.1%, Various components: <0.1%, Cardboard: 14.9%, Wood: 5.3%, Paper: <0.1%

Recycled Material Content:

Manufacture

This Reference Product is manufactured at a site certified with ISO14001. The final assembly is conducted in China.

Distribution

Products are distributed from logistics centers optimized for transport efficiency. The Reference Product is transported an average of 19,000 km by sea and 1,000 km by road from the company's warehouse to the local point of distribution worldwide. Packaging complies with applicable regulations.

Installation

Standard tools are required for the installation of the product.

Use

Under normal operating conditions, this product requires no servicing, maintenance, or additional products.

End of Life

End-of-life factors are considered during the design phase. Components and materials are designed for easy dismantling and sorting for recycling or reuse. The evaluation of environmental impacts covers the entire product lifecycle: manufacturing, distribution, installation, use, and end-of-life. The datasets used are representative of the year 2025.

Environmental Impacts

The following tables detail the environmental impacts across various life cycle stages:

Summary of Environmental Impacts (per kg CO₂ eq.)

Environmental Indicator Total Life Cycle Manufacturing (A1-A3) Distribution (A4) Installation (A5) Use (Total B1-B7) End of Life (C1-C4) Module D
Climate change - total 1.24E+00 6.13E-01 3.53E-02 4.58E-02 4.72E-01 7.36E-02 -5.20E-02
Climate change - fossil fuels 1.22E+00 6.33E-01 3.53E-02 9.36E-03 4.71E-01 7.28E-02 -3.01E-02
Climate change - biogenics 1.79E-02 -1.96E-02 0.00E+00 3.64E-02 3.72E-04 7.65E-04 -2.19E-02
Climate change - land use and land use transformation 1.03E-04 1.03E-04 0.00E+00 0.00E+00 0.00E+00 1.18E-08 0.00E+00
Ozone depletion 2.52E-08 1.97E-08 4.59E-11 3.40E-10 2.22E-09 2.83E-09 -1.71E-09
Acidification (AP) 8.27E-03 3.58E-03 1.23E-03 5.70E-05 2.94E-03 4.63E-04 -6.15E-04
Freshwater eutrophication 3.64E-05 1.37E-05 1.21E-08 7.35E-09 3.40E-07 2.23E-05 2.85E-07
Marine aquatic eutrophication 1.29E-03 5.62E-04 2.89E-04 1.38E-05 3.30E-04 9.90E-05 -2.35E-06
Terrestrial eutrophication 1.46E-02 6.03E-03 3.17E-03 1.82E-04 3.96E-03 1.25E-03 -1.13E-04
Photochemical ozone formation 4.17E-03 1.92E-03 8.16E-04 3.90E-05 1.09E-03 3.05E-04 -9.98E-05
Depletion of abiotic resources - elements 1.04E-04 1.03E-04 0* 0* 6.50E-08 7.26E-07 -7.53E-06
Depletion of abiotic resources - fossil fuels 2.73E+01 1.51E+01 4.46E-01 1.73E-01 8.53E+00 3.01E+00 -3.28E+00
Water requirement (m³ deprivation worldwide eq.) 1.14E+00 1.08E+00 1.16E-04 3.98E-04 2.60E-02 3.26E-02 -4.16E-02
Emission of fine particles (incidence of diseases) 4.87E-08 2.12E-08 6.46E-09 3.94E-10 1.78E-08 2.84E-09 -3.53E-09

*Represents less than 0.01% of the total life cycle of the reference flow.

(1) For the Use phase and according to the current PCR, the information modules B1, B3, B4, B5 and B7, all having indicator values equal to «0» (zero), are not listed in this table.

In accordance with current PCR rules, the environmental indicator values in the «Module D» column must not be summed with the values in the «Total Life Cycle» column.

Environmental Impacts (Continued)

Other Environmental Impacts

Environmental Indicator Total Life Cycle Manufacturing (A1-A3) Distribution (A4) Installation (A5) Use (Total B1-B7) End of Life (C1-C4) Module D
Ionizing radiation, human health (kBq of U235 eq.) 1.67E+00 1.46E+00 0* 3.89E-03 1.86E-01 1.46E-02 -9.46E-01
Ecotoxicity (fresh water) (CTUe) 8.22E+00 5.31E+00 2.11E-02 2.32E-01 8.44E-01 1.81E+00 2.59E-01
Human toxicity, carcinogenic effects (CTUh) 2.81E-08 2.80E-08 0* 0* 5.81E-11 3.72E-11 2.94E-09
Human toxicity, non-carcinogenic effects (CTUh) 2.11E-08 1.66E-08 1.17E-11 7.13E-11 1.98E-09 2.43E-09 -8.21E-09
Impacts related to land use/soil quality 3.82E-01 3.09E-01 0.00E+00 1.81E-04 4.88E-03 6.78E-02 0.00E+00
Use of renewable primary energy, excluding renewable primary energy resources used as raw materials (MJ) 1.77E+00 6.24E-01 5.71E-04 1.30E-02 1.07E+00 5.76E-02 -7.66E-02
Use of renewable primary energy resources used as raw materials (MJ) 2.59E-01 2.59E-01 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2.70E-01
Total use of renewable primary energy resources (primary energy and primary energy resources used as raw materials) (MJ) 2.03E+00 8.83E-01 5.71E-04 1.30E-02 1.07E+00 5.76E-02 1.94E-01
Use of non-renewable primary energy, excluding non-renewable primary energy resources used as raw materials (MJ) 2.48E+01 1.26E+01 4.46E-01 1.73E-01 8.53E+00 3.01E+00 -3.30E+00
Use of non-renewable primary energy resources used as raw materials (MJ) 2.49E+00 2.49E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2.15E-02
Total use of non-renewable primary energy resources (primary energy and primary energy resources used as raw materials) (MJ) 2.73E+01 1.51E+01 4.46E-01 1.73E-01 8.53E+00 3.01E+00 -3.28E+00
Use of secondary materials (kg) 1.76E-02 1.76E-02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
Net use of fresh water (m³) 2.63E-02 2.49E-02 2.70E-06 1.53E-05 6.05E-04 7.78E-04 -9.68E-04
Hazardous waste disposed of (kg) 6.86E-01 5.41E-01 0.00E+00 9.60E-03 1.18E-02 1.23E-01 -4.73E-01
Non-hazardous waste disposed of (kg) 3.93E-01 3.05E-01 1.08E-03 1.36E-03 8.02E-02 5.36E-03 1.00E-02
Radioactive waste disposed of (kg) 1.41E-04 1.27E-04 7.48E-07 5.59E-07 9.75E-06 2.67E-06 4.38E-06
Materials for recycling (kg) 5.62E-02 4.20E-02 0.00E+00 0.00E+00 0.00E+00 1.42E-02 0.00E+00
Total use of primary energy during the life cycle (MJ) 2.93E+01 1.60E+01 4.47E-01 1.86E-01 9.61E+00 3.07E+00 -3.09E+00
Biogenic carbon content of the product (kg of C) 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
Biogenic carbon content of the associated packaging (kg of C) 1.21E-02 1.21E-02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6.41E-03

*Represents less than 0.01% of the total life cycle of the reference flow.

(1) For the Use phase and according to the current PCR, the information modules B1, B3, B4, B5 and B7, all having indicator values equal to «0» (zero), are not listed in this table.

In accordance with current PCR rules, the environmental indicator values in the «Module D» column must not be summed with the values in the «Total Life Cycle» column.

The values of the indicators defined in the PCR-ed4-EN-2021 09 06 are available in the digital database of pep-ecopassport.org website.

Environmental Impacts by Product Category

The following table shows the environmental impacts for products covered by the PEP other than the Reference Product, obtained by applying coefficients to those of the Reference Product.

Cat No Total Life Cycle Manufacturing Distribution Installation Use End of life
282408 1.0 1.0 1.0 1.0 1.0 1.0
282408-C 1.0 1.0 1.0 1.0 1.0 1.0
282408-C1 1.0 1.0 1.0 1.0 1.0 1.0
282408-C2 1.0 1.0 1.0 1.0 1.0 1.0
282408-C3 1.0 1.0 1.0 1.0 1.0 1.0
282409 1.2 1.1 1.1 1.0 1.7 1.2
282409-C 1.2 1.1 1.1 1.0 1.7 1.2
282409-C1 1.2 1.1 1.1 1.0 1.7 1.2
282409-C2 1.2 1.1 1.1 1.0 1.7 1.2
282409-C3 1.2 1.1 1.1 1.0 1.7 1.2
282412 1.2 1.1 1.1 1.0 1.9 1.1
282412-C 1.2 1.1 1.1 1.0 1.9 1.1
282412-C1 1.2 1.1 1.1 1.0 1.9 1.1
282412-C2 1.2 1.1 1.1 1.0 1.9 1.1
282412-C3 1.2 1.1 1.1 1.0 1.9 1.1
282414 1.0 1.0 1.0 1.0 1.0 1.0
282414-C 1.0 1.0 1.0 1.0 1.0 1.0
282414-C1 1.0 1.0 1.0 1.0 1.0 1.0
282414-C2 1.0 1.0 1.0 1.0 1.0 1.0
282414-C3 1.0 1.0 1.0 1.0 1.0 1.0
282426 1.5 1.3 1.3 1.0 2.5 1.4
282426-C 1.5 1.3 1.3 1.0 2.5 1.4
282426-C1 1.5 1.3 1.3 1.0 2.5 1.4
282426-C2 1.5 1.3 1.3 1.0 2.5 1.4
282426-C3 1.5 1.3 1.3 1.0 2.5 1.4
282427 1.4 1.3 1.3 1.0 1.9 1.4
282427-C 1.4 1.3 1.3 1.0 1.9 1.4
282427-C1 1.4 1.3 1.3 1.0 1.9 1.4
282427-C2 1.4 1.3 1.3 1.0 1.9 1.4
282427-C3 1.4 1.3 1.3 1.0 1.9 1.4
282428 1.4 1.3 1.3 1.0 2.5 1.4
282428-C 1.4 1.3 1.3 1.0 2.5 1.4
282428-C1 1.4 1.3 1.3 1.0 2.5 1.4
282428-C2 1.4 1.3 1.3 1.0 2.5 1.4
282428-C3 1.4 1.3 1.3 1.0 2.5 1.4
282429 1.7 1.6 1.6 1.0 2.5 1.8
282429-C 1.7 1.6 1.6 1.0 2.5 1.8
282429-C1 1.7 1.6 1.6 1.0 2.5 1.8
282429-C2 1.7 1.6 1.6 1.0 2.5 1.8
282429-C3 1.7 1.6 1.6 1.0 2.5 1.8

Verification and Compliance

Registration number: LGRP-02062-V01.01-EN

Verifier accreditation N°: VH08

Date of issue: 06-2025

Validity period: 5 years

Drafting rules: «PEP-PCR-ed4-EN-2021 09 06»

Supplemented by: «PSR-0005-ed3.1-2023 12 08»

Information and reference documents: www.pep-ecopassport.org

Independent verification of the declaration and data, in compliance with ISO 14025:2006

The PCR review was conducted by a panel of experts chaired by Julie ORGELET (DDemain).

PEP are compliant with NF C08-100-1:2016 and EN 50693:2019 or NF E38-500:2022.

The elements of the present PEP cannot be compared with elements from another program.

Document in compliance with ISO 14025: 2006: «Environmental labels and declarations. Type III environmental declarations».

Environmental data in alignment with EN 15804:2012 + A2: 2019.

PDF preview unavailable. Download the PDF instead.

LGRP-02062-V01.01-EN Adobe PDF Library 17.0 Adobe InDesign 20.3 (Windows)

Related Documents

Preview Legrand Modular Devices and Distribution Boards 2025 Catalog
Comprehensive catalog of Legrand modular devices and distribution boards for electrical installations and data distribution, featuring circuit breakers, residual current devices, surge protective devices, switches, and distribution boards. Includes product specifications, technical details, and ordering information.
Preview Legrand Plexo IP55: Versatile and Durable Electrical Solutions
Discover the Legrand Plexo IP55 range, offering robust, waterproof, and stylish electrical devices for indoor and outdoor use. Explore switches, sockets, and smart home solutions designed for easy installation and enhanced functionality.
Preview DEMKO Certificate for Legrand Two-Pole Socket Outlets
This DEMKO certificate confirms that Legrand's two-pole socket outlets for raceway, models 077518 and 077519, have been evaluated and meet the requirements of standard DS 60884-2-D1:2023. The certificate details production sites, trademarks, ratings, and certification marks.
Preview Guide Utilisateur Legrand 069815L : Commande Double Encastrée Plexo Gris IP55
Manuel utilisateur pour la commande double encastrée Legrand 069815L (gamme Plexo Gris IP55). Détails sur les caractéristiques techniques, le contenu du produit, les instructions d'installation, les applications, l'entretien et la garantie.
Preview Legrand Wireless 4 Scenes Control CB0414 - Installation and Usage Guide
Install, reset, and use the Legrand Wireless 4 Scenes Control (CB0414) with the Home + Control app. Includes safety instructions, technical specifications, and EU declaration of conformity.
Preview Legrand Plexo™ Weatherproof Wiring Accessories Catalog
Explore the Legrand Plexo™ range of IP55 weatherproof wiring accessories, offering style, freedom of installation, ruggedness, and a wide array of functions for diverse environments. Discover switches, sockets, and connected solutions.
Preview Guide d'installation Legrand 600321 EasyReno Dooxie : Prise double compacte 16A
Manuel utilisateur détaillé pour la prise double compacte monobloc Legrand 600321 de la gamme Dooxie EasyReno. Instructions d'installation, caractéristiques techniques, applications et informations de garantie.
Preview Legrand Wattstopper Digital Lighting Management Low Voltage Switches Quick Start Guide
Quick start guide for Legrand Wattstopper Digital Lighting Management Low Voltage Switches (v3), including installation, operation, and troubleshooting for models LMSW-101, LMSW-102, LMSW-103, LMSW-104, and LMSW-108.