Clipsal FireTek Smoke Alarms

Photoelectric Smoke Alarms for Residential Safety

Learn about the advanced features, benefits, and specifications of Clipsal's photoelectric smoke alarm range, designed to protect homes and families.

Visit: clipsal.com/smokealarms

Your Customers' Investment for Life

Clipsal Fire Tek Smoke Alarms represent a small investment for customers, providing crucial protection for their most valuable assets: family, friends, and home. These alarms feature high-quality, robust electronics designed for reliability, ensuring early detection and warning from hazardous smoke and fire. All Clipsal Smoke Alarms utilize photoelectric detection technology, which effectively detects smoke from smouldering fires - the most common and highest-risk type of fire in residential environments.

Image: A man installing a smoke alarm on a ceiling.

Image: A woman kissing a child in a hallway, with a smoke alarm visible on the ceiling.

Complying with the Code is a Must

The Australian Building Code mandates that all new homes must be equipped with AS3786:2014 compliant smoke alarms connected to mains power. For existing homes, a working smoke alarm is essential, with a 10-year Lithium battery-powered alarm recommended as a minimum level of protection. Installing working photoelectric smoke alarms ensures customers have the best chance of preventing the devastating effects of house fires.

Smoke Alarms to Suit Every Aussie Home

Clipsal Fire Tek Smoke Alarms are designed for any residential environment. The range offers both surface-mount options and a low-profile, flush-mounted option for a more discreet installation.

Easy to Fit, Hard to Beat:

Interconnectivity: Generation 4 surface mount smoke alarms are compatible with Clipsal's 755 series mounting bases, simplifying retrofitting. All Fire Tek alarms, new and old, are fully interconnectable.

Image: Various Clipsal smoke alarm models including 755PSMA4, 755RLPSMA4, 755LPSMA4, 755PFM4, 755RB, and 755RFB2.

Stylish Design

Clipsal Smoke Alarms blend technology with taste, complementing modern home interiors. They are designed for quality, style, and superior protection, offering a modern, sleek, and stylish appearance.

The flush-mount option (755PFM4) is ideal for a subtle look, being 60% smaller and 40% thinner than standard alarms, fitting seamlessly amongst downlights.

Innovative Remote Test/Hush Feature

Optional 755RB and 755RFB2 mounting bases incorporate a remote test/hush feature for enhanced safety and ease of use. This feature can be wired to any momentary switch on a Clipsal switch plate. If activated, the alarm will resume normal operation after approximately 10 minutes. If a fire hazard persists, the alarm will reactivate.

Your Best Connection in Fire Safety

The Clipsal 240V Smoke Alarm range supports hard-wire interconnection for up to 40 units. For situations where running interconnect cables is challenging, a wireless interconnect option is available. The 755RFB2 Wireless Mounting Base allows up to 40 alarms to be wirelessly interconnected and also works with the 755LPSMA4 Lithium battery smoke alarm.

For connectivity with third-party hardware like security systems or emergency exit lighting, the 755RB surface-mounting base offers an integral isolated relay. This relay can be configured to activate upon any interconnect alarm or only the local alarm, enabling identification and communication to other systems.

Image: Close-up of a smoke alarm with indicator lights and buttons labeled "BATTERY", "ALARM", "PUSH", "HUSH", "AC", "POWER".

Features and Benefits

Image: Various certification logos including "5 YEAR WARRANTY", "ACTIVFIRE CERTIFIED PRODUCT", "Australian Standard AS3786:2014", and "SAI Global StandardsMark™".

Certified Fire Safety, Guaranteed

All Clipsal Smoke Alarms are manufactured to the highest quality standards, meeting relevant Australian Standards and ActiveFire listed to comply with the Building Code of Australia. They come with a 5-year limited warranty and carry the "Five Ticks StandardsMark™" SAI Global Certification.

Why Choose Photoelectric?

A significant number of home fires occur annually in Australia. Fire hazards pose the highest risk when occupants are sleeping, with smouldering fires being the most common type encountered. As the sense of smell diminishes during sleep, early fire warning is critical for escape. Photoelectric smoke alarms provide the earliest detection of fire hazards, enabling occupants to escape quickly and safely. They are also recommended by Australian Fire Departments and are free from radioactive material, making them environmentally friendly.

Image: A modern living room with large windows overlooking a garden.

Smoke Alarm Maintenance

Like other home electrical accessories, smoke alarms require regular maintenance for efficient and effective operation.

Test the Smoke Alarm and Battery Every Month

Regular testing ensures optimal protection. Press the Test/Hush button on the unit or use the remote Test/Hush switch (available on 240V surface mounting bases). To check battery condition, switch off the mains power; the alarm should sound, indicating an acceptable battery. If it fails to respond, replace the battery immediately. Clean the alarm monthly to prevent dust or insect ingress, which can cause false alarms.

Replace the Battery Every Year

Smoke alarm batteries should be replaced annually. Customers can choose a memorable date, such as a birthday or the start/end of daylight saving. Alternatively, installing a Lithium battery powered alarm or a 240V Rechargeable lithium alarm eliminates the need for battery replacement.

Replace the Smoke Alarm Every 10 Years

All smoke alarms have a service life of 10 years. After this period, the entire unit must be replaced.

Smoke Alarms in the Home

The Building Code of Australia mandates smoke alarm installation outside sleeping areas and at least one on each level of new homes, interconnected. (Always consult local fire safety regulations for requirements beyond the building code.) In Queensland (QLD), new homes approved after January 1, 2017, require photoelectric mains-powered smoke alarms in every bedroom, interconnected. By January 1, 2027, all existing homes in QLD must have either lithium battery or mains-powered alarms. Clipsal recommends installing multiple smoke alarms for optimum family protection. Australia-wide, interconnected smoke alarms are mandatory for new homes since May 2014.

Careful consideration of smoke alarm locations is advised to avoid false alarms or nuisance tripping. It is recommended to install an alarm in every room (excluding kitchens, laundries, and bathrooms) and interconnect them for maximum protection.

Image: A close-up of a smoke alarm unit, showing its top and side details.

Smoke Alarm Specifications

Model755PSMA4755RLPSMA4755PFM4755LPSMA4
Main Power Source:220-240 V a.c., 50 Hz220-240 V a.c., 50 Hz220-240 V a.c. 50HzSealed-in lithium battery
Secondary Power Source:9 V d.c. carbon zinc or alkaline batteryRechargeable lithium battery (sealed in)9V d.c. carbon zinc or alkaline batteryN/A
Operating Current:<40 mA<40 mA< 40mA< 70mA @ 3V
Standby Power:< 3mW< 3mW< 1mW< 0.04mW
Battery Life:One yearTen yearsOne yearTen years
Terminal Provisions:Active, Neutral, Loop and Interconnect terminals, each accommodates 2 x 1.5 mm²Active, Neutral, Loop and Interconnect terminals, each accommodates 2 x 1.5 mm²Active, Neutral, Loop and Interconnect terminals, each accommodates 3 x 2.5mm²N/A
Sensing Type:Photoelectric. This alarm contains NO radioactive materialPhotoelectric. This alarm contains NO radioactive materialPhotoelectric. This alarm contains NO radioactive materialPhotoelectric. This alarm contains NO radioactive material
Sensing Chamber:Optical sensing chamber with 0.6mm stainless steel mesh (for insect ingress protection)Optical sensing chamber with 0.6mm stainless steel mesh (for insect ingress protection)Optical sensing chamber with 0.6mm stainless steel mesh (for insect ingress protection)Optical sensing chamber with 0.6mm stainless steel mesh (for insect ingress protection)
Interconnecting:40 alarms over 150 metres maximum (40 alarms wirelessly using 755RFB2)40 alarms over 150 metres maximum (40 alarms wirelessly using 755RFB2)40 alarms over 150 metres maximumBuilt-in wireless interconnection (up to 40 alarms over 50m or 40 755RFB2 wireless bases over 30m)
Operating Temperature:0 °C to 45 °C0 °C to 45 °C5°C to 45°C0°C to 45°C
Ambient Humidity:5% to 95%5% to 95%5% to 95%0% to 95%
Horn Level:85 dB at three metres minimum85 dB at three metres minimum85dB at three metres minimum85dB at three metres minimum
Visual Indicators:Green LED for mains power ON. Red LED for warning and low battery indicationGreen LED for mains power ON. Red LED for warning and low battery indicationGreen LED for mains power ON. Red LED for warning and low battery indicationFront: Red (normal alarm mode, test, hush) Rear: Yellow/blue/green for wireless pairing modes
Approvals:Activfire SAI Global RCMActivfire SAI Global RCMActivfire SAI Global RCMActivfire SAI Global RCM
Complies with:AS3786:2014, AS/ NZS60065:2012, AS/ NZS60950-1AS3786:2014, AS/ NZS60065:2012, AS/ NZS60950-1AS3786:2014, AS/ NZS60065:2012, AS/ NZS60950-1AS3786:2014, AS/ NZS60065:2012, AS/ NZS60950-1, AS4268

Accessory Specifications

Model755RB755RFB2756
Main Power Source:220-240 V a.c., 50 Hz220-240 V a.c., 50 Hz6V to 10V d.c. Referenced to Neutral
Secondary Power Source:N/ASealed rechargeable lithium batteryN/A
Operating Current:<40 mA<40 mA1mA min
Battery Life:Ten yearsTen yearsN/A
Terminal Provisions:Active, Neutral, Loop and Interconnect terminals, each accommodates 2×1.5 mm²Active, Neutral, Loop and Interconnect terminals, each accommodates 2×1.5 mm²Interconnect, Neutral and Loop terminals, each accommodate 2x 2.5mm²
Interconnecting:Max. 40 alarms (wired over 150 metres maximum)Max. 40 alarms (wireless) Max. 40 alarms (wired over 150 metres maximum) Max. 40 755LPSMA4 alarmsMax. 40 smoke alarms connected to a single 756 unit.
Operating Temperature:0 °C to 45 °C0 °C to 45 °C0 °C to 45°C
Ambient Humidity:5% to 95%5% to 95%5% to 95%
Relay Rating:250 V a.c., 2 AN/A250V a.c. 10A Resistive and inductive.
Relay Contacts:NO/COM/NC voltage freeN/ANO/COM/NC voltage free
Remote Input:Dry contact momentary switch (for Remote Test / Hush function)Dry contact momentary switch (for Remote Test / Hush function)N/A
Approvals:Activfire RCMActivfire RCMRCM
Complies with:AS/NZS 3100AS/NZS 3100 AS/NZS 4268N/A
Transmit Frequency:N/A433.92 MHz (coded)N/A
RF Range (line of sight):N/A100 m free air, 30 m indoorsN/A

Ordering Details

Catalogue No.Description
755PSMA4240 V a.c. Mains Power Surface Mount Photoelectric Smoke Alarm with 9 V d.c. Battery Backup, Gen 4
755RLPSMA4240 V a.c. Mains Power Surface Mount Photoelectric Smoke Alarm with Rechargeable Lithium Battery Backup, Gen 4
755PFM4240 V a.c. Mains Power Flush Mount Photoelectric Smoke Alarm with 9 V d.c. Battery Backup, Gen 4
755LPSMA4Lithium Battery Powered Photoelectric Smoke Alarm with built-in wireless interconnection
Accessories
755RBSmoke Alarm Mounting Base with Integrated Relay
755RFB2Smoke Alarm Mounting Base with Wireless Interconnect, Gen 2
756Smoke Alarm Isolation relay unit
Models: Clipsal, FireTek, Smoke Alarms

File Info : application/pdf, 12 Pages, 3.70MB

PDF preview unavailable. Download the PDF instead.

A0000302

References

Adobe PDF Library 15.0

Related Documents

Preview Clipsal 755RFB2 Smoke Alarm Mounting Base with Wireless Interconnect - Installation and Operation Guide
Comprehensive guide for the Clipsal 755RFB2 Smoke Alarm Mounting Base, covering installation, wireless interconnection pairing, testing, safety, and technical specifications. Designed for electricians and homeowners.
Preview Clipsal Two-Wire Weather Protected Sunset Switch Installation Instructions (31VSSR, 56SSR)
Installation guide for Clipsal's 31VSSR and 56SSR Two-Wire Weather Protected Sunset Switches. Covers product range, features, operation, installation, wiring diagrams, special loads, timer settings, electrical specifications, and warranty.
Preview Clipsal Airflow 6600ADS Installation Instructions
Comprehensive installation guide for the Clipsal Airflow 6600ADS, a 3-in-1 exhaust fan, light, and gentle heat unit. Includes safety precautions, wiring diagrams, installation steps, and technical specifications.
Preview Clipsal 56AI315-GY 56 Series Appliance Inlet - 15A, 250V, Grey
Technical data sheet for the Clipsal 56AI315-GY appliance inlet. Features include 15A rating, 250V voltage, 3-pin configuration, IP66 protection, and grey polycarbonate construction, suitable for power supply applications.
Preview Clipsal TC32V and TC15 Series Timer Range Installation Instructions
Installation instructions for the Clipsal TC32V and TC15 Series 'Timer' Range, covering wiring, mounting, and setting/adjusting the clocks for 1-hour, 24-hour, and 7-day timers.
Preview Wiser Water Leakage Sensor User Guide
A comprehensive user guide for the Wiser Water Leakage Sensor, detailing its features, installation, operation, and troubleshooting. Learn how to pair, configure, and automate the device for effective water leak detection.
Preview Clipsal CLI-5600ICBT40 Bluetooth In-Ceiling Amplified Speaker Installation & User Manual
Comprehensive installation, user, and warranty guide for the Clipsal CLI-5600ICBT40 Bluetooth In-Ceiling Amplified Speaker. Learn how to connect, pair, and troubleshoot your speaker system.
Preview Clipsal 1025-LB Double Switch Power Point - Technical Data
Detailed product data sheet for the Clipsal 1025-LB Double Switch Power Point, part of the Solis T Series. Features include living brass finish, horizontal mounting, 230V-240V operation, and 10A rating.