Instruction Manual for LARSON ELECTRONICS models including: IND-SFC Series Solid State Frequency Converter Mobile Wheels, IND-SFC Series, Solid State Frequency Converter Mobile Wheels, Frequency Converter Mobile Wheels, Converter Mobile Wheels, Mobile Wheels

GoHz Frequency Converter User Manual

GoHz.com


File Info : application/pdf, 17 Pages, 9.69MB

PDF preview unavailable. Download the PDF instead.

301623
Solid-state Frequency Converter Mobile w/ Wheels Instruction Manual

IND-SFC Series

Larson Electronics, LLC

Phone: (877) 348-9680

Fax: (903) 498-3364

www.larsonelectronics.com

IND-SFC Series
Safety Information
 Read this user manual before using frequency converter.  Keep this user manual near the frequency converter for reading at any time.  Careful in transporting the frequency converter to avoid impact.  Do not put the frequency converter on uneven or inclined surface.  Do not block the venting holes or slits to keep the frequency converter well-cooling effect, the back of the
frequency converter should keep 10 cm (4 inches) away from the wall.  Double check the frequency converter and power supply specifications are matched and well-wired before
power connection to avoid any careless damage.  Frequency converters have different installations according to different capacities and voltage levels,
choose an appropriate configuration and cable diameter.  Do not overload the frequency converter to prevent the electric shock or cause fires.  Please follow all applicable local and national electrical and building code.  In case of abnormal phenomenon happens, follow this user manual in troubleshooting or contact the
manufacturer.  Please keep frequency converter clean and do not put heavy objects on top of it.  Prevent any liquids and sundries into the frequency converter, in order to avoid poor contact or short circuit,
electric shock, or fire.  Unplug the power cord in stormy weather.  Avoid placing in direct sunlight, raining or humid place.  Keep it away from the source of ignition and heat to prevent overheat.  Unplug the power cord during moving or maintaining the frequency converter.

Larson Electronics, LLC

Phone: (877) 348-9680

Fax: (903) 498-3364

www.larsonelectronics.com

IND-SFC Series
Product Features  Frequency converter is suitable for use with resistive, capacitive, inductive and non-linear loads.  Compatible with 50 Hz & 60 Hz input frequency.  Adjustable single phase 0-300v AC, three phase 0-520v AC output voltage.  Adjustable 40.0 to 120 Hz output frequency, customize 499.9Hz.  Precise 4 LED digital display output frequency, voltage, ampere and wattage.  Isolated operation, no harmonic distortion (EMI, EMC).  Pure sine wave output.  IGBT/PWM technology enhances compact size, low noise and high reliability.  Capable to simulate global voltage, frequency power supplies.  Frequency converters are equipped with electronic circuit/instant trip breaker/buzzer alarm for over
voltage, over current, over temperature, output short circuit protection. Checklist
Every frequency converter has functional testing before leaving factory, the frequency converter is wooden
packaged, includes:  1 unit frequency converter  Operation manual























LNG LNG

RSTNG LNG

Single Phase

Larson Electronics, LLC

Phone: (877) 348-9680

Three Phase to Single Phase

Fax: (903) 498-3364

www.larsonelectronics.com




 

RSTNG UVWNG



 

Three Phase
 Operation Panel  Input Air-switch  Output Air-switch  Input Terminals  Output Terminals  Low/High Voltage Switch (For 30kVA and Above)  Low/High Voltage Indicator (For 3-Phase 3kVA to 20kVA)  Phase/Line Voltage Switch (For 3-Phase 3kVA to 20kVA)

IND-SFC Series

Larson Electronics, LLC

Phone: (877) 348-9680

Fax: (903) 498-3364

www.larsonelectronics.com

IND-SFC Series

Wiring Precaution
 Whether the capacity of the frequency converter in accordance with your loads.  Whether the frequency converter damaged during transportation, if so, do not connect it to power source.  Shut down power before wiring, check the input voltage before installation.  Make sure the specification of the cable in accordance with the frequency converter before wiring. The
cable diameter should follow the voltage level and capacity of the frequency converter.  Please refer to electrician wiring regulations, or following the "Cable Diameter Reference" table.  Avoid sharing the power switch of the frequency converter with other appliances.  Use O-type wiring terminals, make sure it's well-wired, tighten screws to avoid poor contact and prevent
electric shock.  Make sure the power source is correct to match single phase or three phase frequency converter.  For grounding, refer to the next page.  Make sure all switches on "OFF" status before connecting the frequency converter to power source.  Make sure the power source, frequency converter and loads are matching before power on.  Internal semiconductor components are sensitive to static electricity, be careful in touching the metal
control panel.
Grounding System  In addition to safety consideration, well-grounded system also can avoid the power system interferes
equipment normal operation.  Ground Cable should be separated with Neutral Cable, unless special applications.  Ground Cable should be 8AWG cable at least or the diameter is basically the same.  Ground Cable is for specified frequency converter only, poor ground will cause interference to other
machines.  Use ground rods in grounding for the best.  Ground Types:

Item 1 2 3
4

Application

Resistance value

Low voltage power supply system or high voltage electrical equipment of three-phase four-wire multi-grounded systems 10 or less grounding

Ungrounded high-voltage electrical equipment grounding system.

25 or less

Low voltage power supply system of three-phase three-wire 50 or less
ungrounded system.

1.

Low voltage electrical equipment grounding

2.

Inner system grounding

3.

Frequency converter secondary grounding

4.

Low voltage electrical equipment metal body

grounding.

1. round voltage less than 150V is 100 or less. 2. round voltage 151V to 300V is 50 or less. 3. round voltage higher than 301V is 10 or less.

Larson Electronics, LLC

Phone: (877) 348-9680

Fax: (903) 498-3364

www.larsonelectronics.com

Cable Diameter Reference Table

IND-SFC Series

1Ø 2W / 220V

Capacity 2kVA

Input

L

N

2.5mm2

3kVA

4mm2

5kVA

6mm2

10kVA

10mm2

15kVA

16mm2

20kVA

25mm2

30kVA

35mm2

G 2.5mm2 2.5mm2 6mm2 10mm2 10mm2 10mm2 10mm2

1Ø 2W / 0-300V

Max. O/P Current

Output

Low 16.8A

Hi 8.4A

L

N

2.5mm2

25A

12.5

4mm2

41.6A 20.8A

6mm2

83.2A 41.6A

16mm2

125A 62.5A

25mm2

166.6A 83.3A

35mm2

250A

125A

50mm2

G 2.5mm2 2.5mm2 6mm2 10mm2 10mm2 10mm2 10mm2

3Ø 4W / 380V

Input Capacity
RST N

10kVA

4mm2

15kVA

6mm2

20kVA

6mm2

30kVA

10mm2

45kVA

16mm2

50kVA

16mm2

60kVA 75kVA 90kVA 100kVA

25mm2 30mm2 35mm2 50mm2

120kVA

70mm2

150kVA

95mm2

G 6mm2 6mm2 6mm2 10mm2 10mm2 10mm2 10mm2 10mm2 10mm2 10mm2 10mm2 10mm2

1Ø 2W / 0-300V

Max. O/P Current

Output

Low

Hi

L

N

83.2A 41.6A

16mm2

G 10mm2

125A

62.5A

25mm2

10mm2

166.6A 83.3A

35mm2

10mm2

250A

125A

50mm2

10mm2

375A 187.5A

75mm2

10mm2

416.6A 208.3A

83mm2

10mm2

500A 625A 750A 833.3A

250A 312.5A 375A 416.7A

100mm2 150mm2 180mm2 200mm2

10mm2 10mm2 10mm2 10mm2

1000A 500A

250mm2

10mm2

1250A 625A

300mm2

10mm2

Larson Electronics, LLC

Phone: (877) 348-9680

Fax: (903) 498-3364

www.larsonelectronics.com

IND-SFC Series

3Ø 4W/ 380V

Capacity R
3kVA

Input ST N 1.5mm2

10kVA

4mm2

15kVA

6mm2

20kVA

6mm2

30kVA

10mm2

45kVA 60kVA

16mm2 25mm2

75kVA

30mm2

90kVA 100kVA 120kVA 150kVA

35mm2 50mm2 70mm2 95mm2

200kVA

120mm2

300kVA

180mm2

G 2.5mm2 2.5mm2 6mm2 6mm2 6mm2 10mm2 10mm2 10mm2 10mm2 10mm2 10mm2 10mm2 10mm2 10mm2

3Ø 4W / 0-520V

Max. O/P Current

Low Hi

U

8.4A

4.2A

Output VW N 2mm2

27.6A 13.8A

6mm2

41.6A 20.8A

8mm2

55.6A 27.8A

10mm2

83.2A 41.6A

16mm2

125A 62.5A 166.6A 83.3A

25mm2 35mm2

208.3A 104.2A

42mm2

250A 125A 277.7A 138.8A 333.3A 166.6A 416.6A 208.3A

50mm2 70mm2 95mm2 120mm2

555.5A 277.7A

185mm2

833.3A 416.6A

240mm2

G 6mm2 6mm2 6mm2 6mm2 6mm2 10mm2 10mm2 10mm2 10mm2 10mm2 10mm2 10mm2 10mm2 10mm2

Note: user can choose different cables according to the input and output conditions, when the input or output cable length exceeds 20 meters, the cable diameter should be doubled.

Larson Electronics, LLC

Phone: (877) 348-9680

Fax: (903) 498-3364

www.larsonelectronics.com

Wiring Terminals

IND-SFC Series

Single Phase Input, Single Phase output.

L N G
Input

L NG
Output

Three Phase Input, Single Phase Output.

RS T NG LNG

Input

Output

Three Phase Input, Three Phase Output.

RS T NGU VWNG

Input

Output

Larson Electronics, LLC

Phone: (877) 348-9680

Fax: (903) 498-3364

www.larsonelectronics.com

Chapter V. Operation Panel

IND-SFC Series

*Some models may differ slightly in layout*

Larson Electronics, LLC

Phone: (877) 348-9680

Fax: (903) 498-3364

www.larsonelectronics.com

IND-SFC Series
Chapter VI. Operation Guide
Proper operating procedures allow you to use the frequency converter more smoothly and avoid unnecessary troubles. 1. Make sure the POWER ON switch is on OFF position. 2. Make sure the switches, rotary buttons, displays are not loosen or damaged. 3. Make sure the power supply is matching with the frequency converter specifications (110V, 220V etc.)
before turning the input POWER ON switch to ON position. 4. Set the output frequency by "FREQUENCY SET" switch. Note, press OFF/RESET for setting hundreds
frequency (1xx.x). 5. Choose the Low/High Voltage output voltage according to the loads, for 150V change 0-150V (low) and
1-300V (high) base on required voltage. 6. Press to POWER ON switch (ON). 7. Connect loads cable and turn on the AC OUTPUT switch to obtain required standard AC power supplies. 8. Frequency converter has overcurrent (overload), over temperature, short circuit, instantaneous power off
protection and warning indicators. In case of above phenomenon happens, the protection circuit cut off output immediately and trigger warning buzzer. 9. Press OFF / RESET switch to cut off the output.
Caution: For 30kVA frequency converter (and above), to switch Low/High voltage, if the frequency converter is connected loads, the frequency converter must be powered off and turn off the output switch before switching the voltage.

Larson Electronics, LLC

Phone: (877) 348-9680

Fax: (903) 498-3364

www.larsonelectronics.com

IND-SFC Series

Chapter VII. Specification
Single Phase Input, Single Phase Output

Capacity Voltage (Optional) Input
Frequency

500VA

Voltage

Frequency Low-grade 4.2A
Current High-grade 2.1A
Load stabilization Rate
Output Frequency Stability Harmonic Distortion
Frequency meter Voltmeter Ammeter Watt meter

Protection

Working Environment

Temperature Humidity

1kVA

2kVA

3kVA

5kVA

10kVA 15kVA

1 Phase 2 Wire: 110V/220V/230V/240 ± 10% 50Hz or 60Hz ± 5%
0-150V (Low Voltage range)

0-300V (High Voltage range)

40.0Hz to 120Hz (Higher than 120Hz is customized)

8.4A

16.8A

25A

41.6A

83.2A

125A

4.2A

8.4A

12.5A

20.8A

41.6A

62.5A

±1%

±0.01%

Pure Sine Wave 2%

4 digit, digital frequency meter, resolution 0.1Hz/Step

4 digit, digital voltage meter, resolution 0.1V

4 digit, digital ammeter, resolution 0.1A

4 digit, digital Watt meter, resolution 0.1W

With overload, short circuit, over temperature

Instantaneous power failure protection and alarm device 0 - 40 deg. 
0 - 90% (Non condensation)

20kVA
166.6A 83.3A

Larson Electronics, LLC

Phone: (877) 348-9680

Fax: (903) 498-3364

www.larsonelectronics.com

Three Phase Input, Single Phase Output

IND-SFC Series

Capacity
Voltage (Optional) Input
Frequency

10kVA

15kVA

20kVA

30kVA

45kVA

50kVA

60kVA

3 Phase 4 Wire: Wye Type 190/110, 200/115, 208/120, 220/128, 230/132, 240/139V±10%

3 Phase 4 Wire: Wye Type 380/220, 400/230, 415/240, 440/254, 460/265, 480/277V ± 10%

3 Phase 4 Wire: Della Type 220, 230, 240, 380, 400, 415, 440V ± 10%

50Hz or 60Hz ± 5%

Voltage

0-150V (Low Voltage range) 0-300V (High Voltage range)

Frequency
Low-grade Current
High-grade
Load stabilization Rate Output Frequency Stability

83.2A 41.6A

40.0Hz to 120Hz (Higher than 120Hz is customized)

125A

166.6A

250A

375A

416.6A

62.5A

83.3A

125A

187.5A

208.3A

±1%

±0.01%

500A 250A

Harmonic Distortion

Pure Sine Wave 2%

Frequency meter

4 digit, digital frequency meter, resolution 0.1Hz/Step

Voltmeter

4 digit, digital voltage meter, resolution 0.1V

Ammeter

4 digit, digital ammeter, resolution 0.1A

Watt meter Protection Working Environment

Temperature Humidity

4 digit, digital Watt meter, resolution 0.1W With overload, short circuit, over temperature Instantaneous power failure protection and alarm device
0 - 40 deg.  0 - 90% (Non condensation)

Larson Electronics, LLC

Phone: (877) 348-9680

Fax: (903) 498-3364

www.larsonelectronics.com

Three Phase Input, Single Phase Output

IND-SFC Series

Capacity

75kVA

90kVA

100kVA

120kVA

150kVA

3 Phase 4 Wire: Wye Type 190/110, 200/115, 208/120, 220/128, 230/132, 240/139V±10%

Input

Voltage(Optional)

3 Phase 4 Wire: Wye Type 380/220, 400/230, 415/240, 440/254, 460/265, 480/277V ± 10% 3 Phase 4 Wire: Della Type 220, 230, 240, 380, 400, 415, 440V ± 10%

Frequency

50Hz or 60Hz ± 5%

Voltage

0-150V (Low Voltage range) 0-300V (High Voltage range)

Frequency

40.0Hz to 120Hz (Higher than 120Hz is customized)

Low-grade
Current High-grade

625A 312.5A

750A 375A

833.3A 416.6A

1000A 500A

1250A 625A

Output Load stabilization Rate

±1%

Frequency Stability Harmonic Distortion

±0.01% Pure Sine Wave 2%

Frequency meter

4 digit, digital frequency meter, resolution 0.1Hz/Step

Voltmeter

4 digit, digital voltage meter, resolution 0.1V

Ammeter

4 digit, digital ammeter, resolution 0.1A

Protection

With overload, short circuit, over temperature Instantaneous power failure protection and alarm device

Working Environment

Temperature Humidity

0 - 40 deg.  0 - 90% (Non condensation)

Larson Electronics, LLC

Phone: (877) 348-9680

Fax: (903) 498-3364

www.larsonelectronics.com

Three Phase Input, Three Phase Output

IND-SFC Series

Capacity
Voltage (Optional) Input
Frequency

3kVA

10kVA

15kVA

20kVA

30kVA

45kVA

60kVA

3 Phase 4 Wire: Wye Type 190/110, 200/115, 208/120, 220/128, 230/132, 240/139V±10%

3 Phase 4 Wire: Wye Type 380/220, 400/230, 415/240, 440/254, 460/265, 480/277V ± 10%

3 Phase 4 Wire: Della Type 220, 230, 240, 380, 400, 415, 440V ± 10%

50Hz or 60Hz ± 5%

Voltage

0-260V (Low Voltage range) 0-520V (High Voltage range)

Frequency

40.0Hz to 120Hz (Higher than 120Hz is customized)

Low-grade

8.4A

Current

High-grade

4.2A

Load stabilization Rate Output
Frequency Stability

27.6A 13.8A

41.6A 20.8A

55.6A 27.8A
±1% ±0.01%

83.2A 41.6A

125A 62.5A

166.6A 83.3A

Harmonic Distortion

Pure Sine Wave 2%

Frequency meter

4 digit, digital frequency meter, resolution 0.1Hz/Step

Voltmeter

4 digit, digital voltage meter, resolution 0.1V

Ammeter

4 digit, digital ammeter, resolution 0.1A

Watt meter

4 digit, digital Watt meter, resolution 0.1W

Protection Working Environment

Temperature Humidity

With overload, short circuit, over temperature Instantaneous power failure protection and alarm device
0 - 40 deg.  0 - 90% (Non condensation)

Larson Electronics, LLC

Phone: (877) 348-9680

Fax: (903) 498-3364

www.larsonelectronics.com

Three Phase Input, Three Phase Output

IND-SFC Series

Capacity Voltage (Optional) Input
Frequency

75kVA

100kVA

120kVA

150kVA

200kVA

300kVA

3 Phase 4 Wire: Wye Type 190/110, 200/115, 208/120, 220/128, 230/132, 240/139V±10%

3 Phase 4 Wire: Wye Type 380/220, 400/230, 415/240, 440/254, 460/265, 480/277V ± 10%

3 Phase 4 Wire: Della Type 220, 230, 240, 380, 400, 415, 440V ± 10%

50Hz or 60Hz ± 5%

Voltage

0-260V (Low Voltage range) 0-520V (High Voltage range)

Frequency

40.0Hz to 120Hz (Higher than 120Hz is customized)

Low-grade Current
High-grade
Load stabilization Rate Output
Frequency Stability

208.3A 104.2A

277.7A 138.8A

333.3A

416.6A

166.7A

208.3A

±1%

±0.01%

555.5A 277.7A

833.3A 416.6A

Harmonic Distortion

Pure Sine Wave 2%

Frequency meter

4 digit, digital frequency meter, resolution 0.1Hz/Step

Voltmeter

4 digit, digital voltage meter, resolution 0.1V

Ammeter

4 digit, digital ammeter, resolution 0.1A

Watt meter Protection

4 digit, digital Watt meter, resolution 0.1W With overload, short circuit, over temperature Instantaneous power failure protection and alarm device

Working Environment

Temperature Humidity

0 - 40 deg.  0 - 90% (Non condensation)

Larson Electronics, LLC

Phone: (877) 348-9680

Fax: (903) 498-3364

www.larsonelectronics.com

IND-SFC Series

Chapter VIII. Troubleshooting

Please pay attention to internal high voltage components, only qualified electricians can maintain the frequency converter. Turn off the frequency converter before proceeding troubleshooting procedures if it's not necessary to do live troubleshooting.

Phenomenon

Inspection methods

roubleshooting

No input power

1. put switch is turn on or not? 2. put voltage is right or not? 3. The fuse is burn down or not?

1. Turn the power supply input switch. 2. onnect to correct voltage power supply. 3. heck the fuse and replace the fuse with same specification if necessary.

Output power outage

1. Is t power off or momentary power off? 2. Is it overload?

1. Press he activate switch (ON) to reboot. 2. ake sure the loads are within the capacity of the frequency converter.

No output voltage

1. Is he fuse burn down or not? 2. Is t overloaded?

1. heck the fuse and replace the fuse with same specification if necessary. 2. eplace a larger capacity frequency converter.

Voltmeter, ammeter and power show "0" when the output frequency is normal.

1. Turn the power switch to "OFF" position. 2. hange output voltage switch to zero. 3. Turn the power switch to "ON" position.

Voltmeter, ammeter and power show "0" and alarm rings when the output frequency is normal.

1. Check and decrease the loads' current. 2. Press he shutdown/reset button (OFF/RESET). 3. Re-operatio

High temperature

1. Is it overload? 1. Dec ase loads.
2. ooling fan is slowdown or not 2. eplace a new cooling fan.
worked.

Emergency

Please advise: 1. Fr uency converter model & serial number. 2. ate & Time of the failure. 3. oads. 4. etailed description of the failure.

Larson Electronics, LLC

Phone: (877) 348-9680

Fax: (903) 498-3364

www.larsonelectronics.com

Chapter IX. Maintenance

IND-SFC Series

Frequency converters do not require daily maintenance, a regular maintenance is benefited of longer lifetime, the maintain times is in accordance with the environmental conditions.
Preventive Measures:  Do not put any liquid objects on the top of the frequency converter.
 If the frequency converter is installed in a harsh environment, such as windy and dusty, pay more attention
to make the frequency converter clean or do more frequent maintenances.
Maintenances:
 Turn off the power switch.  Clean inner dusts.  Wipe the cabinet, cover and venting holes with a soft towel and detergent.
 Visual inspection of all power lines and terminals, see if there is collision, loose, hot corrosion, moisture,
insect bites or rat bites, do some repairs or replaces if necessary. Note: DO NOT do any maintenance if you are not a qualified electrician, and make sure the frequency converter is discharged completely before proceeding any maintenance.
Chapter X. Storage
The environment of the frequency converter being placed has direct affect to its function and lifetime, the environment should follow the conditions:
Moving:  Please shut down and disconnect all cables before moving the frequency
converter.  Do not move the frequency converter upside down.  Handle the frequency converter with care in moving to avoid impact. Placement:  Do not put the frequency converter on uneven or inclined place.  Avoid direct sunlight, rain or humid place.  Keep it away from fire and high temperature place to prevent overheating.  Avoid oil mist, salt, corrosive gases erosion.  Avoid dust, cotton and small metal objects intrusion.
 Keep the frequency converter in a well-ventilated place, keep the frequency converter's back away from
the wall at least 10cm to ensure sufficient ventilation.  Operating temperature 0 - 40, humidity 0 - 90% (non-condensing).

THESE INSTRUCTIONS MAY NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS. SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT SALES@LARSONELECTRONICS.COM OR BY PHONE AT 1-877-348-9680 FOR FURTHER ASSISTANCE.
PLEASE VISIT LARSONELECTRONICS.COM FOR WARRANTY AND RETURN INFORMATION.

Larson Electronics, LLC

Phone: (877) 348-9680

Fax: (903) 498-3364

www.larsonelectronics.com



References

Acrobat Distiller 11.0 (Windows)