User Guide for LANCOM Systems models including: 1793VA, VDSL Voip VPN Router, Voip VPN Router, VPN Router, 1793VA, Router

Hardware Quick Reference Guide LANCOM 1793VA

LANCOM 1793VA Hardware Quick Reference Guide

Connectors, Ports, HWS, Initial Operation, Installation, Technical Details

LANCOM Systems GmbH

Quick Reference Guide

LANCOM 1793VA: LANCOM Systems GmbH


File Info : application/pdf, 1 Pages, 587.89KB

HWS 1793VA EN
Hardware Quick Reference
LANCOM 1793VA

Gigabit Ethernet 10/100/1000

TE / NT

NT

VDSL / ADSL

ETH 4

ETH 3

ETH 2

ETH 1 Analog 2/4 Analog 1/3 Config (Com) ISDN 1

ISDN 2

USB DC 12 V













 VDSL / ADSL interface Use the supplied DSL cable for the IP-based line to connect the VDSL interface and the provider's telephone socket. For more information, please contact your Internet service provider.
 Ethernet interfaces Use an Ethernet cable to connect one of the interfaces ETH 1 to ETH 4 to your PC or a LAN switch.
 Analog interfaces Connect analog terminal devices to the analog interfaces either directly via RJ11, or with the help of the enclosed TAE adapters. Further adapters are optionally available.
 Configuration interface Use a serial configuration cable to connect the serial interface (COM) to the serial interface of the device you want to use for configuring / monitoring (separately available).

 ISDN interfaces ISDN 1: Internal (NT) or external (TE) ISDN bus. This feature is controlled by LCOS. ISDN 2: Internal (NT) ISDN bus.
A 100-Ohm resistor for line termination is switchable in LCOS.
 USB interface You can use the USB interface to connect a USB printer or a USB memory stick.
 Power After connecting the cable to the device, turn the bayonet connector 90° clockwise until it clicks into place. Use only the supplied power adapter.

Cloud-ready

Before initial startup, please make sure to take notice of the information regarding the intended use in the enclosed installation guide!
Operate the device only with a professionally installed power supply at a nearby power socket that is freely accessible at all times.

Please observe the following when setting up the device

i

 The power plug of the device must be freely accessible.  For devices to be operated on the desktop, please attach the adhesive rubber footpads

 Do not rest any objects on top of the device

 Keep all ventilation slots on the side of the device clear of obstruction

 In case of wall mounting, use the drilling template as supplied

 Rack installation with the optional LANCOM Rack Mount (separately available)

Mounting & connecting

LANCOM 1793VA

 











 Power

Off Green, permanently*
Red / green blinking
Red blinking 1x green inverse blinking* 2x green inverse blinking* 3x green inverse blinking*

Device switched off
Device operational, resp. device paired / claimed and LANCOM Management Cloud (LMC) accessible
Configuration password not set. Without a configuration password, the configuration data in the device is unprotected.
Charge or time limit reached
Connection to the LMC active, pairing OK, device not claimed
Pairing error, resp. LMC activation code not available
LMC not accessible, resp. communication error

 Online Off Green, blinking
Green, permanently Red, permanently

WAN connection inactive
WAN connection is established (e.g. PPP negotiation)
WAN connection active
WAN connection error

 DSL

Off

Interface deactivated

Green, permanently DSL connection active

Green, flickering

DSL data transfer

Red, flickering

DSL transfer error

Red / orange, blinking DSL hardware error

Orange, blinking

DSL training

Orange, permanently DSL sync

Green, blinking

DSL connecting

 ISDN 1, 2

Off

Interface deactivated

Green, permanently D-channel active

Green, flickering

ISDN data transfer

Red, flickering

ISDN transfer error

Red / orange, blinking ISDN hardware error

 ETH 1, 2, 3, 4 Off Green, permanently
Green, flickering

No networking device attached
Connection to network device operational, no data traffic
Data transmission

 VoIP Off Green, permanently
Red, permanently
Red or green, inverse flashing

No SIP accounts defined or VCM is off
All defined and active SIP accounts (outgoing) were successfully registered
Not all defined and active SIP accounts were registered (possibly still in process)
Number of currently used lines (connecting or connected)

 VPN
Off Green, permanently Green, flashing

VPN connection inactive VPN connection active VPN connecting

 Reset Reset button

Operated e.g. with a paper clip short press: Restart the device long press: Reset the device

 Analog 1, 2, 3, 4

Off Green, permanently Orange, blinking Green, blinking

Interface deactivated Interface activated Incoming call Connection active

Hardware

Power supply

12 V DC, external power adapter (230 V); bayonet connector to secure against disconnection

Power consumption Max. 15 W

Environment

Temperature range 0­35 °C; humidity 0­95 %, non-condensing

Housing

Robust synthetic housing, rear connectors, ready for wall mounting, Kensington lock; dimensions 210 x 45 x 140 mm (W x H x D)

Number of fans None; fanless design without rotating parts, high MTBF

Interfaces

WAN: VDSL2

VDSL2 as per ITU G.993.2; profiles 8a, 8b, 8c, 8d, 12a, 12b, 17a, 35b VDSL Supervectoring as per ITU G.993.2 (Annex Q) VDSL2 vectoring as per ITU G.993.5 (G.Vector) Compatible with VDSL2 and U-R2 from Deutsche Telekom (1TR112) ADSL2+ over ISDN as per ITU G.992.5 Annex B/J with DPBO, ITU G.992.3, and ITU G.992.1 ADSL2+ over POTS as per ITU G.992.5 Annex A/M with DPBO, ITU G.992.3, and ITU.G.992.1 Supports just one virtual connection at a time in ATM (VPI-VCI pair)

ETH

4 individual ports, 10 / 100 / 1000 Mbps Gigabit Ethernet, by default set to switch mode.

Up to 3ports can be operated as additional WAN ports. Ethernet ports can be electrically

disabled in the LCOS configuration.

USB

USB 2.0 hi-speed host port for connecting USB printers (USB print server), serial devices (COM-port server) or USB drives (FAT file system)

ISDN 1 / ISDN 2

ISDN 1: Internal (NT) or external (TE) ISDN bus. This feature is controlled by LCOS. According to the settings, connect an ISDN cable either to the NTBA or the ISDN terminal device. ISDN 2: Internal (NT) ISDN bus. Use an ISDN cable to connect the ISDN device to the ISDN interface.

Analog 1 / Analog 3 Use the cable of your analog devices to connect them with the analog interfaces. If Analog 2 / Analog 4 necessary use the adapters from the LANCOM Analog Adapter Set.

Config (Com) / V.24 Serial configuration interface/COM-port (8-pin mini-DIN): 9,600 - 115,200 baud, suitable for optional connection of analog/GPRS modems. Supports internal COM-port server and provides transparent asynchronous serial-data transfer via TCP.

WAN protocols
VDSL, ADSL, Ethernet ISDN

PPPoE, PPPoA, IPoA, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and IPoE (with or without DHCP), RIP-1, RIP-2, VLAN
DSS1 (Euro-ISDN), PPP, X75, HDLC, ML-PPP, V.110/GSM/HSCSD

Package content
Cable Adapters Power adapter

1 DSL cable for an IP-based line, 4.25 m
2 TAE adapters (RJ11 - TAE)
External power supply adapter (230 V), 12 V / 2 A DC/S; barrel / bayonet (EU), LANCOM item no. 111303 (not for WW devices)

*) The additional power LED statuses are displayed in 5-seconds rotation if the device is configured to be managed by the LANCOM Management Cloud.
This product contains separate open-source software components which are subject to their own licenses, in particular the General Public License (GPL). The license information for the device firmware (LCOS) is available on the device`s WEBconfig interface under "Extras > License information". If the respective license demands, the source files for the corresponding software components will be made available on a download server upon request.

Hereby, LANCOM Systems GmbH | Adenauerstrasse 20/B2 | D-52146 Wuerselen, declares that this device is in compliance with Directives 2014/30/EU, 2014/53/EU, 2014/35/EU, 2011/65/EU, and Regulation (EC) No. 1907/2006. The full text of the EU Declaration of Conformity is available at the following Internet address: www.lancom-systems.com/doc

LANCOM, LANCOM Systems, LCOS, LANcommunity and Hyper Integration are registered trademarks. All other names or descriptions used may be trademarks or registered trademarks of their owners. This document contains statements

relating to future products and their attributes. LANCOM Systems reserves the right to change these without notice. No liability for technical errors and/or omissions.

111764/0622

LED description & technical details



References

Adobe PDF Library 16.0.7 Adobe InDesign 17.2 (Windows)