EMPIRE SR-18T-4 Owner's Manual
Shop genuine replacement parts for EMPIRE SR-18T-4
Find Your EMPIRE Fireplace Parts - Select From 642 Models -------- Manual continues below --------

INSTALLATION INSTRUCTIONS AND
OWNER'S MANUAL
unVented room heater
ModELS SR-10T-4 SR-18T-4 SR-30T-4

SR-30T SHOWN

Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.
WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
-- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
-- WHAT TO DO IF YOU SMELL GAS · Do not try to light any appliance. · Do not touch any electrical switch; do not use any phone in your building. · Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. · If you cannot reach your gas supplier, call the fire department.
-- Installation and service must be performed by a qualified installer, service agency or the gas supplier.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to page 6.
WARNING: If not installed, operated and maintained in accordance with the manufacturer's instructions, this product could expose you to substances in fuel or from fuel combustion which can cause death or serious illness.
Water Vapor: A By-Product of Unvented Room Heaters Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU's (.3KW's) of gas input per hour. Refer to page 6.

Page 1

TABLE OF CONTENTS
SectionPage
Important Safety Information..........................................................................3 Safety Information for Users of LP Gas.........................................................4 Introduction....................................................................................................5 Specifications.................................................................................................5 Water Vapor: A By-Product of Unvented Room Heaters................................6 Provisions for Adequate Combustion and Ventilation Air...............................6 Gas Supply.....................................................................................................7 SR-10T Clearances .......................................................................................8 SR-18T Clearances .......................................................................................9 SR-30T Clearances .......................................................................................9 Wall Mount Installation............................................................................10-11 Optional Floor Stand Installation.................................................................. 11 Lighting Instructions ....................................................................................12 Main Burner Flame Characteristics .............................................................13 Pilot Flame Characteristics .........................................................................14 Thermostat Operation..................................................................................14 Appliance Maintenance................................................................................15 Troubleshooting............................................................................................16 SR-10T Parts List ........................................................................................16 SR-18T and SR-30T Parts List ....................................................................17 SR-10T Parts View ......................................................................................18 SR-18T Parts View ......................................................................................19 SR-30T Parts View ......................................................................................20 Optional Blower Installation Instructions ................................................21-22 Master Parts Distributor List.........................................................................23 How To Order Repair Parts..........................................................................23

Page 2

35964-0-0615

IMPORTANT SAFETY INFORMATION
This Is a Heating Appliance
Do Not Operate This Appliance Without Front Panel Installed.

DANGER: Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING: Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION: Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE: Addresses practices not related to personal injury. · An unvented room heater having an input rating of
more than 6,000 Btu per hour shall not be installed in a bathroom.
· An unvented room heater having an input rating of more than 10,000 Btu per hour shall not be installed in a bedroom or bathroom.
· Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
· Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition.
· Young children should be carefully supervised when they are in the same room with the appliance.
· Do not place clothing or other flammable material on or near the appliance.

· Due to high surface temperatures, keep children, clothing and furniture away.
· Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.
· Do not use this room heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

·

Warning: Any change to this HEATER or its

controlS can be dangerous.

Any safety screen or guard removed for servicing

an appliance must be replaced prior to operating the

heater.

· Keep appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids

·

WARNING: Failure to keep the primary air opening(s)

of the burner(s) clean may result in sooting and property

damage.

warning

When used without adequate combustion and ventilation air, heater may give off CARBON MONOXIDE, an odorless, poisonous gas.
Do not install heater until all necessary provisions are made for combustion and ventilation air. Consult the written instructions provided with the heater for information concerning combustion and ventilation air. In the absence of instructions, refer to the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation, or applicable local codes.
This heater is equipped with a pilot light safety system designed to turn off the heater if not enough fresh air is available.
Do NOT TAMPER WITH PILOT LIGHT SAFETY SYSTEM!
If heater shuts off, do not relight until you provide fresh air.
If heater keeps shutting off, have it serviced. Keep burner and control compartment clean.

Carbon monoxide poisoning may lead to death.
Early signs of carbon monoxide poisoning resemble the flu, with headache, dizziness and/or nausea. If you have these signs, heater may not be working properly. Get fresh air at once! Have heater serviced.
Some people -- pregnant women, persons with heart or lung disease, anemia, those under the influence of alcohol, those at high altitudes -- are more affected by carbon monoxide than others.
The pilot light safety system senses the depletion of oxygen at its location. If this heater is installed in a structure having a high vertical dimension, the possibility exists that the oxygen supply at the higher levels will be less than that at the heater. In this type of application, a fan to circulate the structure air will minimize this effect. The use of this fan will also improve the comfort level in the structure. When a fan is used to circulate air, it should be located so that the air flow is not directed at the burner.

35964-0-0615

Page 3

SAFETY INFORMATION FOR USERS OF LP-GAS

Propane (LP-Gas) is a flammable gas which can cause fires and explosions. In its natural state, propane is odorless and colorless. You may not know all the following safety precautions which can protect both you and your family from an accident. Read them carefully now, then review them point by point

with the members of your household. Someday when there may not be a minute to lose, everyone's safety will depend on knowing exactly what to do. If, after reading the following information, you feel you still need more information, please contact your gas supplier.

LP-GAS WARNING ODOR
If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas. That's your signal to go into immediate action!

· Do not operate electric switches, light matches, use your phone. Do not do anything that could ignite the gas.
· Get everyone out of the building, vehicle, trailer, or area. Do that IMMEDIATELY.
· Close all gas tank or cylinder supply valves. · LP-Gas is heavier than air and may settle in low areas such
as basements. When you have reason to suspect a gas leak, keep out of basements and other low areas. Stay out until firefighters declare them to be safe. · Use your neighbor's phone and call a trained LP-Gas service

person and the fire department. Even though you may not continue to smell gas, do not turn on the gas again. Do not re-enter the building, vehicle, trailer, or area. · Finally, let the service man and firefighters check for escaped gas. Have them air out the area before you return. Properly trained LP-Gas service people should repair the leak, then check and relight the gas appliance for you.

no odor detected - odor fade

Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor. Sometimes other odors in the area mask the gas odor. People may not smell the gas odor or their minds are on something else. Thinking about smelling a gas odor can make it easier to smell.
The odorant in LP-gas is colorless, and it can fade under some circumstances. For example, if there is an underground leak, the movement of the gas through soil can filter the odorant. Odorants in LP-Gas also are subject to oxidation. This fading can occur if

there is rust inside the storage tank or in iron gas pipes.
The odorant in escaped gas can adsorb or absorb onto or into walls, masonry and other materials and fabrics in a room. That will take some of the odorant out of the gas, reducing its odor intensity.
LP-Gas may stratify in a closed area, and the odor intensity could vary at different levels. Since it is heavier than air, there may be more odor at lower levels. Always be sensitive to the slightest gas odor. If you detect any odor, treat it as a serious leak. Immediately go into action as instructed earlier.

some points to remember

· Learn to recognize the odor of LP-gas. Your local LP-Gas Dealer can give you a "Scratch and Sniff" pamphlet. Use it to find out what the propane odor smells like. If you suspect that your LP-Gas has a weak or abnormal odor, call your LP-Gas Dealer.
· If you are not qualified, do not light pilot lights, perform service, or make adjustments to appliances on the LP-Gas system. If you are qualified, consciously think about the odor of LP-Gas prior to and while lighting pilot lights or performing service or making adjustments.
· Sometimes a basement or a closed-up house has a musty smell that can cover up the LP-Gas odor. Do not try to light pilot lights, perform service, or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP-Gas.
· Odor fade, due to oxidation by rust or adsorption on walls of new cylinders and tanks, is possible. Therefore, people should be particularly alert and careful when new tanks or cylinders are placed in service. Odor fade can occur in new tanks, or reinstalled old tanks, if they are filled and allowed to set too long before refilling. Cylinders and tanks which have been out of service for a time may develop internal rust which will

cause odor fade. If such conditions are suspected to exist, a periodic sniff test of the gas is advisable. If you have any question about the gas odor, call your lp-gas dealer. A periodic sniff test of the lp-gas is a good safety measure under any condition.
· If, at any time, you do not smell the LP-Gas odorant and you think you should, assume you have a leak. Then take the same immediate action recommended above for the occasion when you do detect the odorized LP-Gas.
· If you experience a complete "gas out," (the container is under no vapor pressure), turn the tank valve off immediately. If the container valve is left on, the container may draw in some air through openings such as pilot light orifices. If this occurs, some new internal rusting could occur. If the valve is left open, then treat the container as a new tank. Always be sure your container is under vapor pressure by turning it off at the container before it goes completely empty or having it refilled before it is completely empty.

Page 4

35964-0-0615

INTRODUCTION

Instructions to Installer 1. Installer must leave instruction manual with owner after
installation. 2. Installer must have owner fill out and mail warranty card supplied
with unvented room heater. 3. Installer should show owner how to start and operate unvented
room heater.
Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of an unvented room heater.
This appliance may be installed in an aftermarket* permanently located, manufactured (mobile) home, where not prohibited by state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
General Information This appliance is design certified in accordance with American National Standards Institute Z21.11.2 by the Canadian Standards Association Laboratories as an Unvented Room Heater and shall be installed according to these instructions.
Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change.
Important All correspondence should refer to complete Model Number, Serial Number and type of gas.
Well Head Gas Installations Some natural gas utilities use "well head" gas. This may affect the Btu output of the unit. Contact the gas company for the heating value. Contact the manufacturer or your gas company before changing spud/orifice size.

Qualified Installing Agency Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term "qualified agency" means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) the installation, testing, or replacement of gas piping or (b) the connection, installation, testing, repair, or servicing of equipment; that is experienced in such work; that is familiar with all precautions required, and that has complied with all the requirements of the authority having jurisdiction.
State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.
In the State of Massachusetts, unvented propane and natural gas-fired space heaters shall be prohibited in bedrooms and bathrooms.
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 (latest edition).* *Available from the American National Standards Institute, Inc., 11 West 42nd St., New York, N.Y. 10036.
High Altitudes For altitudes/elevations above 2,000 feet (610m) ratings should be reduced at the rate of 4 percent for each 1,000 feet (305m) above sea level. Contact the manufacturer or your gas company before changing spud/orifice size.

SPECIFICATIONS

Model Input BTU/HR (KW/H) Five Plaques
BTU/HR (KW/H) Three Plaques BTU/HR (KW/H) One Plaque Height Width Depth Gas Inlet Accessories Blower Floor Stand

SR-10T -
10,000 (2.9) 22" (559mm) 11 7/8" (302mm) 6 1/2" (165mm) 3/8" (10mm)
SRS-10*

SR-18T -
18,000 (5.3) -
22" (559mm) 18" (457mm) 6 1/2" (165mm) 3/8" (10mm)
SRB-18T SRS-18

SR-30T 30,000 (8.8)
22" (559mm) 24 1/8" (613mm) 6 1/2" (165mm) 3/8" (10mm)
SRB-30T SRS-30

*Floor stand can not be used in a bedroom installation. SR-10T must be wall mounted in a bedroom installation. The bathroom or bedroom must be an unconfined space.

35964-0-0615

Page 5

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS

Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU's (.3KW's) of gas input per hour.
Unvented room heaters must be used as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplemental heat applications, the water vapor does not create a problem. In most applications, the water vapor enhances the low humidity atmosphere experienced during cold weather.

The following steps will help insure that water vapor does not become a problem. 1. Be sure the heater is sized properly for the application, including
ample combustion air and circulation air. 2. If high humidity is experienced, a dehumidifier may be used to
help lower the water vapor content of the air. 3. Do not use an unvented room heater as the primary heat source
(an entire house).

PROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION AIR

This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.
A confined space is an area with volume less than 50 cubic feet per 1,000 Btuh of the combined input rates of all appliances drawing combustion air from that space. Small areas such as equipment rooms are confined spaces. Furnaces installed in a confined space which supply heated air to areas outside the space must draw return air from outside the space through tightly sealed return air ducts. A confined space must have 2 openings into the space for combustion air. One opening must be within 12 inches of the ceiling and the other must be within 12 inches of the floor. The required sizing of these openings is determined by whether inside or outside air is used to support combustion, the method by which the air is brought to the space (vertical or horizontal duct) and by the total input rate of all appliances in the space.
The following example is for determining the volume of a typical area in which the SR-30T may be located and for determining if this area fits the definition of an unconfined space.
The input of the SR-30T is 30,000 Btu per hour. Based on the 50 cubic feet per 1,000 Btu per hour formula, the minimum area that is an unconfined space for installation of the SR-30T is 1,500 cubic feet, 50 cubic feet x 30 = 1,500 cubic feet. To determine the cubic feet of the area in which the SR-30T is to be installed, measure the length, width and height of the area. Example: The area measures 16 feet in length, 12 feet in width and 8 feet in height, the area is 1,536 cubic feet. The SR-30T can be installed in this unconfined space with no requirement to provide additional combustion and ventilation air.

Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
Unusually tight construction is defined as construction where: a. Walls and ceilings exposed to the outside atmosphere have
a continuous water vapor retarder with a rating of one perm or less with openings gasketed or sealed, and b. Weatherstripping has been added on openable windows and doors, and c. Caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.
If the SR-30T heater is installed in a building of unusually tight construction, adequate air for combustion, ventilation and dilution of flue gases shall be provided in accordance with ANSI Z223.1/ NFPA54.

WARNING
If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation, or applicable local codes.

Page 6

35964-0-0615

GAS SUPPLY

The gas line can be routed either through the floor or wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing.
Gas Supply Check all local codes for requirements, especially for the size and type of gas supply line required.

A gas valve and ground joint union should be installed in the gas line upstream of the gas control to aid in servicing. It is required by the National Fuel Gas Code that a drip line be installed near the gas inlet. This should consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles may collect.

Recommended Gas Pipe Diameter

Pipe Length Schedule 40 Pipe Inside Diameter

Tubing, Type L Outside Diameter

Nat.

L.P.

Nat.

L.P.

0-10 feet

1/2"

3/8"

1/2"

3/8"

0-3 meters 12.7mm 9.5mm 12.7mm 9.5mm

10-40 feet

1/2"

1/2"

5/8"

1/2"

4-12 meters 12.7mm 12.7mm 15.9mm 12.7mm

40-100 feet

1/2"

1/2"

3/4"

1/2"

13-30 meters 12.7mm 12.7mm 19mm 12.7mm

100-150 feet 3/4"

1/2"

7/8"

3/4"

31-46 meters 19mm 12.7mm 22.2mm 19mm

NOTICE: Never use plastic pipe. Check to confirm whether your local codes allow copper tubing or galvanized.
NOTICE: Since some municipalities have additional local codes, it is always best to consult your local authority and installation code.
Dimensions Apply to SR-10T, SR-18T and SR-30T

Figure 1
Installing a New Main Gas Cock Each appliance should have its own manual gas cock.
A manual main gas cock should be located in the vicinity of the unit. Where none exists, or where its size or location is not adequate, contact your local authorized installer for installation or relocation.
Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied petroleum gases. The gas lines must be checked for leaks by the installer. This should be done with a soap solution watching for bubbles on all exposed connections, and if unexposed, a pressure test should be made.
Never use an exposed flame to check for leaks. Appliance must be disconnected from piping at inlet of control valve and pipe capped or plugged for pressure test. Never pressure test with appliance connected; control valve will sustain damage!

Figure 2
Method of Installing a Tee Fitting Sediment Trap (Figure 2) The use of the following gas connectors is recommended: -- ANS Z21.24 Appliance Connectors of Corrugated Metal Tubing
and Fittings -- ANS Z21.45 Assembled Flexible Appliance Connectors of Other
Than All-Metal Construction The above connectors may be used if acceptable by the authority having jurisdiction.The state of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length.
Pressure Testing of the Gas Supply System 1. To check the inlet pressure to the gas valve, a 1/8" (3mm) N.P.T.
plugged tapping, accessible for test gauge connection, must be placed immediately upstream of the gas supply connection to the appliance. 2. The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). 3. The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
Attention! If one of the above procedures results in pressures in excess of 1/2 psig (14" w.c.) (3.5 kPa) on the appliance gas valve, it will result in a hazardous condition.
Checking Manifold Pressure Natural gas will have a manifold pressure of approximately 6.0" w.c. (1.49kPa) at the pressure regulator outlet with the inlet pressure to the pressure regulator from a minimum of 7.0" w.c. (1.743kPa) for the purpose of input adjustment to a maximum of 10.5" w.c. (2.615kPa). Propane/LP gas will have a manifold pressure approximately 10.0" w.c. (2.49kPa) at the pressure regulator outlet with the inlet pressure to the pressure regulator from a minimum of 11.0" w.c. (2.739kPa) for the purpose of input adjustment to a maximum of 13.0" w.c. (3.237kPa).
A test gage connection is located downstream of the gas appliance pressure regulator for measuring gas pressure. The connection is a 1/8 inch (3mm) N.P.T. plugged tapping.

35964-0-0615

Page 7

SR-10T CLEARANCES
When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.
Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet. Rear wall 0 inches (0mm). Ceiling 24 inches (610mm). Minimum vertical clearance from a projection above the appliance (shelves, window sills, etc.) 14 inches (356mm). Maximum horizontal extension of projection above the appliance 12 inches (305mm). Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and proper operation must be provided.

(610mm)

(356mm)

6" (152mm)

(152mm)

Figure 4 (SR-10T)

(51mm)

Figure 3 (SR-10T)

Page 8

35964-0-0615

SR-18T CLEARANCES

When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.
Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet. Rear wall 0 inches (0mm). Ceiling 36 inches (914mm). Minimum vertical clearance from a projection above the appliance (shelves, window sills, etc.) 36 inches (914mm). Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and proper operation must be provided.

(152mm)

(914mm)

(152mm)

(51mm)
Figure 5 (SR-18T)

SR-30T CLEARANCES

When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.
Left side 8 inches (203mm). Right side 8 inches (203mm). Do not install in alcove or closet. Rear wall 0 inches (0mm). Ceiling 36 inches (914mm). Minimum vertical clearance from a projection above the appliance (shelves, window sills, etc.) 36 inches (914mm). Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and proper operation must be provided.

36" (914mm) (203mm)

(203mm)

35964-0-0615

Figure 6 (SR-30T) Page 9

WALL MOUNT INSTALLATION

Refer to Figures 7, 8 and 9 for measurements in order to locate (4) mounting holes on wall. Figures 7, 8 and 9 are the front views of the heaters.
1. Remove lower louver from casing assembly (2 screws). 2. Remove reflector from casing assembly (2 screws). 3. Remove upper louver from casing assembly (2 screws).

(51) (28mm)

(613mm) (511mm)

(28 mm)

(300 mm)

(198 mm)

(51)

(51)

(479 mm)

(51) (559 mm)

(479 mm)

(559 mm)

(102 mm) MIN

2" (51 mm)

(102 mm)

(28mm)

Figure 7 (SR-10T)
(457mm) (356mm)

(479mm) (102mm)

(52mm)

(51 mm)
(559mm) (51mm)

Figure 9 (SR-30T)
On Solid Wall 1. After locating mounting holes, attach (4) #10 x 1" (25mm) screws provided into the wall. Do not completely tighten screwheads to the wall, leave a 1/8" (3mm) gap between screwheads and wall. 2. Mount heater onto the (4) screwheads and complete tightening screwheads into the wall. Attention! Use the following steps to properly align the upper louver and the reflector with the heat shield. a. When replacing upper louver, be sure the bottom lip of upper louver goes behind the heat shield. b. When replacing reflector, be sure the top lip of reflector goes in front of the heat shield. 3. Connect the gas line.
On Sheet Rock Wall 1. After locating mounting holes, drill (4) 5/16" (8mm) diameter holes into the wall. 2. Insert (4) plastic expansion anchors provided into the holes. 3. Tighten (4) #10 x 1" (25mm) screws provided into the plastic expansion anchors. Do not completely tighten screwheads to the plastic expansion anchors, leave a 1/8" (3mm) gap between screwheads and plastic expansion anchors.

Figure 8 (SR-18T)

Page 10

35964-0-0615

4. Mount heater onto the (4) screwheads and complete tightening the screwheads to the plastic expansion anchors. Attention! Use the following steps to properly align the upper louver and the reflector with the heat shield. a. When replacing upper louver, be sure the bottom lip of upper louver goes behind the heat shield. b. When replacing reflector, be sure the top lip of reflector goes in front of the heat shield.
5. Connect the gas line.

Figure 10

OPTIONAL FLOOR STAND INSTALLATION

1. Align clearance holes on floor stand with screw holes on bottom of heater, as shown in Figure 11.
2. Attach floor stand to heater with (4) screws provided with floor stand.
3. Connect the gas line.
*Floor stand can not be used in a bedroom installation. SR-10T must be wall mounted in a bedroom installation.

Installation on Rugs and Tile If this appliance is installed directly on carpeting, tile or other combustible material, other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.
Attention: Optional Floor Stand meets requirement.
The base referred to above does not mean the fire-proof base as used on wood stoves. The protection is for rugs that are extremely thick and light colored tile.

35964-0-0615

SR-30T Shown Figure 11

Page 11

LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
Warning: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
B. Before lighting smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. What To Do If You Smell Gas · Do not try to light any appliance. · Do not touch any electrical switch; do not use any phone in your building. · Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. · If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

Lighting Instructions

1. Stop! Read the safety information above. 2. Set thermostat (gas control knob) to lowest setting. 3. Turn off all electric power to the appliance (if applicable). 4. Push in gas control knob slightly and turn clockwise
to "OFF". Do not force. 5. Wait ten (10) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.
6. Find pilot - the pilot is attached at the bottom of the burner assembly .

back up. Pilot should remain lit. If it goes out, repeat steps 4

through 8.

· If knob does not pop up when released, stop and imme-

diately call your service technician or gas supplier.

· If the pilot will not stay lit after several tries, turn the gas

control knob to "OFF" and call your service technician or

gas supplier.

9. Attention! Gas control has an INTERLOCK latching device.

When the pilot is initially lit and the safety magnet is energized

(pilot stays "ON") the INTERLOCK latching device becomes

operative. If the gas control is turned to the "OFF" position or

gas flow to the appliance is shut off, the pilot cannot be re-

lighted until the safety magnet is de-energized (approximately

60 seconds). There will be an audible "click" when the safety

magnet in the gas control is de-energized. Pilot can now be

relighted. Repeat steps 4 through 8.

10. Turn gas control knob counterclockwise

to "HI".

11. Turn on all electric power to appliance (if applicable).

12. Set thermostat (gas control knob) to desired setting from "HI"

to "LO".

7. Turn gas control knob

counterclockwise

to "PILOT."

8. Push in gas control knob all the way and hold in. Repeatedly

push the piezo ignitor button until pilot is lit (or use a match to

light pilot). Continue to hold the control knob in for about one

(1) minute after the pilot is lit. Release knob and it will pop

To Turn Off Gas To Appliance

1. Set thermostat (gas control knob) to lowest setting.
2. Turn off all electric power to appliance if service is to be performed (if applicable).

3. Push in gas control knob slightly and turn clockwise to "OFF". Do not force.

Page 12

35964-0-0615

MAIN BURNER FLAME CHARACTERISTICS

SR-10T, SR-18T and SR-30T Main Burner Flame (Figure12) The main burner flame will have a red-orange glow over the surface of the ceramic plaques. A few small, hairline cracks may form over the surface of the ceramic plaques or at the edges of the ceramic plaques where they have been cemented into position on the burner assembly frame. These small, hairline cracks will not affect the operation or performance of the ceramic plaques. Only, when large cracks develop, with blue flames escaping from the large cracks, should you contact your Qualified Service Person.
A red-orange haze that is visible on the ceramic plaques is acceptable. A blue flame that rolls out at the top of the ceramic plaques indicates an accumulation of dust, lint or spider webs inside the casing assembly and main burner assembly. Use the following procedure to inspect the casing assembly and main burner assembly.
1. Turn OFF gas supply to the heater. 2. Turn OFF electric supply to the heater if optional blower is
installed in heater. 3. Remove lower louver from casing assembly ( 2 screws). 4. Remove reflector from casing assembly (2 screws). 5. Inspect interior of casing assembly for accumulation of dust, lint
or spider webs. If necessary, clean interior of casing assembly with a vacuum cleaner or apply air pressure. Do not damage any components within casing assembly when you are cleaning. 6. Remove pilot bracket from main burner assembly (2 screws). 7. Pivot pilot bracket with attached pilot away from main burner assembly (do not damage pilot tubing). 8. Inspect main burner orifice(s) through the rectangular opening(s) in the venturi (throat) of the main burner(s). Dust, lint and spider webs can accumulate on top of the main burner orifice(s). If necessary, clean main burner orifice(s) with a vacuum cleaner or apply air pressure. To thoroughly clean the main burner orifice(s) proceed to Step 9.

9. Disconnect supply tubing from orifice holder(s). 10. Remove orifice holder from venturi of main burner assembly
(1 screw for each orifice holder). 11. Remove main burner orifice from orifice holder. 12. Apply air pressure through main burner orifice and orifice holder
to remove dust, lint or spider webs. 13. Apply air pressure into ceramic plaque(s) to remove dust, lint
or spider webs. 14. As parts are being replaced in reverse order, check for gas
leaks at all gas connections before lower louver is replaced onto casing assembly.
SR-30T SHOWN Figure 12

35964-0-0615

Page 13

PILOT FLAME CHARACTERISTICS

The correct flame will be blue and will extend beyond the thermocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet.

2. Blow air pressure through the holes indicated by the arrows. This will blow our foreign materials such as dust, lint and spider webs. Tighten nut B also by grasping nut A.

Figure 13
Oxygen Depletion Sensor Pilot (Figure 14) When the pilot has a large yellow tip flame, clean the Oxygen Depletion Sensor as follows:
1. Clean the ODS pilot by loosening nut B from the pilot tubing. When this procedure is required, grasp nut A with an open end wrench.

Figure 14
Never use needles, wires, or similar cylindrical objects to clean the pilot to avoid damaging the calibrated ruby that controls the gas flow.

THERMOSTAT OPERATION

To ignite main burner, turn gas control knob counterclockwise toward HI setting. To shut down main burner, turn gas control knob clockwise toward LO setting.
The SR-10T has an input of 10,000 BTUH (2.9KW/H). The hydraulic thermostat bulb is located at the casing assembly bottom. When the hydraulic thermostat bulb senses the need for heat, the unit cycles "ON" at a full input rate of 10,000 BTUH (2.9KW/H). The unit remains at this full input rate until the hydraulic thermostat bulb is "satisfied." When the hydraulic thermostat bulb is "satisfied" the burner will shut "OFF" with the pilot flame remaining "ON."
The SR-18T has an input of 18,000 BTUH (5.3KW/H). The hydraulic thermostat bulb is located at the casing assembly bottom. When the hydraulic thermostat bulb senses the need for heat, the unit cycles "ON" at a full input rate of 18,000 BTUH (5.3KW/H). The unit remains at this full input rate until the hydraulic thermostat bulb is "satisfied." When the hydraulic thermostat bulb is "satisfied" the burner will shut "OFF" with the pilot flame remaining "ON."
NOTICE: The burner does not modulate between "ON" and the pilot flame. When the SR-18T is "ON," all three ceramic plaques will "glow." There will never be a time when only one or two ceramic plaques are "glowing."
The SR-30T has an input of 30,000 BTUH (8.8KW/H). The hydraulic thermostat bulb is located at the casing assembly bottom. When the hydraulic thermostat bulb senses the need for heat, the unit cycles "ON" at a full input rate of 30,000 BTUH (8.8KW/H). The unit remains at this full input rate until the hydraulic thermostat bulb is "satisfied." When the hydraulic thermostat bulb is "satisfied" the burner will shut "OFF" with the pilot flame remaining "ON."

NOTICE: The burner does not modulate between "ON" and the pilot flame. When the SR-30T is "ON," all five ceramic plaques will "glow." There will never be a time when only one or three ceramic plaques are "glowing."
The LO and HI setting has temperature range of approximately 55°F (12.78°C) to 90°F (32.22°C), respectively. This is the temperature at the hydraulic thermostat bulb not the room temperature. The owner is advised to determine the particular heat setting that is desired for comfort, as heating requirements are different for every owner.
Attention: If the owner does not want the main burner to ignite and turns the gas control knob to the Lo setting, the main burner will still ignite if the temperature at the hydraulic thermostat bulb drops to 55°F (12.78°C).
If no heat is desired, turn the gas control knob to the PILOT position.
Main Burner Operation Description of Gas Control Knob:
OFF position.
PILOT position.
LO/HI will allow the hydraulic thermostat bulb to cycle the heater ON and OFF.

Page 14

35964-0-0615

APPLIANCE MAINTENANCE

Removing Pilot/Thermocouple From Main Burner Assembly Attention: The thermocouple CAN NOT be replaced as an individual item. You must order a new pilot when replacing thermocouple.
1. Turn OFF gas supply to the heater. 2. Turn OFF electrical supply to the heater if optional blower is
installed in heater. 3. Remove lower louver from casing assembly (2 screws). 4. Remove reflector from casing assembly (2 screws). 5. Disconnect pilot tubing from pilot (see Figure 14, Page 14).
Grasp nut A with a wrench when removing nut B with a second wrench. 6. Remove pilot from pilot bracket (2 screws). 7. Remove thermocouple lead from gas valve. 8. As parts are being replaced in reverse order, check for gas leaks at all gas connections before lower louver is replaced onto casing assembly.
Removing Main Burner Orifice(s) From Main Burner Assembly 1. Turn off gas supply to the heater. 2. Turn off electrical supply to the heater if optional blower is
installed in heater. 3. Remove lower louver from casing assembly (2 screws). 4. Remove reflector from casing assembly (2 screws). 5. Remove pilot bracket from main burner assembly (2 screws). 6. Pivot pilot bracket with attached pilot away from main burner
assembly (do not damage pilot tubing). 7. Disconnect supply tubing from orifice holder(s). 8. Remove orifice holder from venturi of main burner assembly
(1 screw for each orifice holder). 9. Remove main burner orifice from orifice holder. Attention: The
number stamped on the main burner orifice is a millimeter diameter. 10. As parts are being replaced in reverse order, check for gas leaks at all gas connections before lower louver is replaced onto casing assembly.
Removing Gas Valve From Casing Assembly 1. Turn off gas supply to the heater. 2. Turn off electrical supply to the heater if optional blower is
installed in heater. 3. Remove lower louver from casing assembly (2 screws). 4. Remove reflector from casing assembly (2 screws). 5. Remove upper louver from casing assembly (2 screws). 6. If installed, remove optional blower assembly (4 screws). 7. Disconnect inlet supply tubing, outlet supply tubing, pilot supply
tubing and thermocouple lead from gas valve. 8. If heater is attached to wall, disconnect gas supply line from
inlet regulator. 9. Remove heater from wall.

10. Remove gas valve bracket from casing assembly (4 screws to be removed are located on casing assembly back).
11. Remove hydraulic thermostat bulb from thermostat bulb clip located at casing assembly bottom.
12. Remove gas valve from gas valve bracket. 13. As parts are being replaced in reverse order, check for gas
leaks at all gas connections before upper louver, reflector and lower louver are replaced onto casing assembly.
Removing Main Burner From Casing Assembly 1. Turn off gas supply to the heater. 2. Turn off electrical supply to the heater if optional blower is
installed in heater. 3. Remove lower louver from casing assembly (2 screws). 4. Remove reflector from casing assembly (2 screws). 5. Disconnect supply tubing from orifice holder(s). 6. Remove pilot bracket from main burner assembly (2 screws). 7. Remove main burner assembly from casing assembly (4
screws). 8. Remove orifice shield from main burner assembly. Attach orifice
shield to new main burner assembly. 9. As parts are being replaced in reverse order, check for gas
leaks at all gas connections before lower louver is replaced onto casing assembly.
Piezo Pilot Ignitor Instructions Depressing the ignitor button completely causes a spark to occur at the pilot.
To light the pilot, it is important that the electrode be 1/8" (3mm) from the pilot. The spark must occur at the point the pilot flame hits the thermocouple.
On a new installation with air in the gas line, it is suggested that a match be used. The match will light the pilot faster than the piezo under this condition.

35964-0-0615

Page 15

TROUBLESHOOTING

1. Spark electrode does not produce spark. a. Spark electrode broken - replace. b. Ignitor wire may not be attached to spark electrode attach. c. Ignitor wire damaged - replace. d. Piezo ignitor defective - replace.
2. Spark electrode produces spark but pilot does not light. a. No gas to heater - turn on gas. b. PILOT position not properly aligned - turn gas control knob to Pilot position and depress. c. Pilot is blocked from spider web or dirt - clean pilot, see Page 14.
3. Pilot flame does not stay "ON" when control knob is released. a. Control knob in pilot position not completely depressed or held in long enough. b. INTERLOCK latching device is operative - see "Lighting Instructions," Page 12, Step 9. c. Thermocouple not tightened into gas control - tighten thermocouple.

d. Pilot flame not surrounding thermocouple - clean pilot, see Page 14.
e. Inlet gas pressure too low, contact gas supplier. f. Thermocouple defective - replace. g. Gas control defective - replace. 4. Main burner does not ignite. a. Main burner orifice is blocked - clean, see "Main Burner Flame
Characteristics," Page 13. Attention: The number stamped on the main burner orifice is a millimeter diameter. b. Inlet gas pressure too low, contact gas supplier. 5. Heater keeps shutting "OFF" during normal operation. a. Pilot is blocked - clean pilot, see Page 14. b. Inlet gas pressure too low, contact gas supplier

PARTS LIST

SR-10T
PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide.

INDEX NO. 1 2 3 4 5 6 7
8
9 10 10 11 12 13 13 14
15
15
16 17

PART NO. DESCRIPTION

13347 SR-180 R-2313 SR-008 SR-113 R-6563 12438
12437
10753 R-5097 R-5098 SR-158 R-2314 R-2317 R-2476 R-2331
R-6308
R-6307
R-6310 R-6309

CASING SIDE ASSEMBLY - LEFT CASING BACK PIEZO IGNITOR CASING SIDE ASSEMBLY - RIGHT VALVE BRACKET GAS VALVE -SIT TUBING - GAS VALVE TO BURNER TUBING - INLET REGULATOR TO GAS VALVE INLET REGULATOR BRACKET INLET REGULATOR - NAT INLET REGULATOR - LPG TUBING - GAS VALVE TO PILOT ORIFICE HOLDER MAIN BURNER ORIFICE - NAT MAIN BURNER ORIFICE - LPG BURNER PILOT ASSEMBLY (LPG ONLY) (INCLUDES ITEMS 16 & 17) PILOT ASSEMBLY (NAT ONLY) (INCLUDES ITEMS 16 & 17) PILOT THERMOCOUPLE SPARK IGNITOR

INDEX PART NO. DESCRIPTION NO.

18

SR-179 PILOT BRACKET (NAT)

18

SR-032 PILOT BRACKET (LPG)

19

SR-153 ORIFICE SHIELD

20

R-2305 CHROME GRILL

21

SR-134 CASING LOUVER (2 REQUIRED)

22

35953 REFLECTOR ASSEMBLY

23

SR-135 HEAT SHIELD

24

R-1992 BULB CLIP

25

SRS-10 OPTIONAL FLOOR STAND KIT

NS

R-2390 IGNITOR WIRE

NS

SR-216 HARDWARE PACKAGE

NS - NOT SHOWN

Page 16

Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-0529 35964-0-0615

PARTS LIST

SR-18T

SR-30T

PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide.

INDEX NO. 1 2 3 4 5 6 7 8 9
10
10
11 12 13 13 14 15
16
17 18 19 19 20 21 22 23 24 25 26 27 28
29
30 31 32 33 34 35 36
37
NS NS NS

PART NO.
13348 SR-090 R-2313 SR-008 SR-113 R-6563 R-2330 SR-119 SR-032
R-6307
R-6308
R-6310 R-6309 R-2315 R-2498 R-2314 SR-204
SR-201
SR-098 R-2334 R-5097 R-5098 10753 12439 12437 R-2304 SR-076 35954 SR-077 R-1992 SR-120
SR-122
R-1454 R-1499 SR-196 R-2099 R-1468 R-2395 R-2503
R-2396
SR-219 R-2390 SR-216

DESCRIPTION
CASING SIDE ASSEMBLY - LEFT CASING BACK PIEZO IGNITOR CASING SIDE ASSEMBLY - RIGHT VALVE BRACKET GAS VALVE -SIT BURNER ORIFICE SHIELD PILOT BRACKET PILOT ASSEMBLY (NAT ONLY)) (INCLUDES ITEMS 11 & 12) PILOT ASSEMBLY (LPG ONLY)) (INCLUDES ITEMS 11 & 12) PILOT THERMOCOUPLE SPARK IGNITOR MAIN BURNER ORIFICE - NAT (3 REQUIRED) MAIN BURNER ORIFICE - LPG (3 REQUIRED) ORIFICE HOLDER (3 REQUIRED) TUBING - MANIFOLD TO BURNER TWO TUBING - MANIFOLD TO BURNER ONE AND THREE (2 REQUIRED) TUBING - GAS VALVE TO PILOT MANIFOLD INLET REGULATOR - NAT INLET REGULATOR - LPG INLET REGULATOR BRACKET TUBING - GAS VALVE TO MANIFOLD TUBING - INLET REGULATOR TO GAS VALVE CHROME GRILL CASING LOUVER (2 REQUIRED) REFLECTOR ASSEMBLY HEAT SHIELD BULB CLIP OPTIONAL SRS-18 FLOOR STAND KIT OPTIONAL SRB-18T BLOWER KIT (INCLUDES 30 THROUGH 37) BRASS BUSHING (4 REQUIRED) RUBBER GROMMET (4 REQUIRED) BLOWER PAN CORD SET ASSEMBLY BUSHING - HEYCO #SR5KN4 WIRE ASSEMBLY FAN CONTROL BLOWER (INCLUDES MOTOR, FAN, AND FAN HOUSING) BLOWER HARDWARE PACKAGE IGNITOR WIRE HARDWARE PACKAGE

INDEX NO. 1 2 3 4 5 6 7 8 9
10
10
11 12 13 13 14 15
16
17
18 19 20 21 22 22 23 24 25 26 27 28 29
30
31 32 33 34 35 36 37 38 NS NS NS

PART NO. 13348 SR-041 R-2313 SR-008 SR-113 R-6563 R-2329 SR-114 SR-032
R-6307
R-6308
R-6310 R-6309 R-2315 R-2498 R-2314 SR-203
SR-202
SR-201
R-2333 12437 12440 10753 R-5097 R-5098 SR-054 R-2303 SR-017 35955 SR-018 R-1992 SR-115
SR-116
R-1454 R-1499 SR-198 R-2099 R-1468 R-2395 R-2503 R-2396 SR-219 R-2390 SR-216

DESCRIPTION
CASING SIDE ASSEMBLY - LEFT CASING BACK PIEZO IGNITOR CASING SIDE ASSEMBLY - RIGHT VALVE BRACKET GAS VALVE -SIT BURNER ORIFICE SHIELD PILOT BRACKET PILOT ASSEMBLY (NAT ONLY)) (INCLUDES ITEMS 11 & 12) PILOT ASSEMBLY (LPG ONLY)) (INCLUDES ITEMS 11 & 12) PILOT THERMOCOUPLE SPARK IGNITOR MAIN BURNER ORIFICE - NAT (5 REQUIRED) MAIN BURNER ORIFICE - LPG (5 REQUIRED) ORIFICE HOLDER (5 REQUIRED) TUBING - MANIFOLD TO BURNER THREE TUBING - MANIFOLD TO BURNER ONE AND FIVE (2 REQUIRED) TUBING - MANIFOLD TO BURNER TWO AND FOUR (2 REQUIRED) MANIFOLD TUBING - INLET REGULATOR TO GAS VALVE TUBING - GAS VALVE TO MANIFOLD INLET REGULATOR BRACKET INLET REGULATOR - NAT INLET REGULATOR - LPG TUBING - GAS VALVE TO PILOT CHROME GRILL CASING LOUVER (2 REQUIRED) REFLECTOR ASSEMBLY HEAT SHIELD BULB CLIP OPTIONAL SRS-30 FLOOR STAND KIT OPTIONAL SRB-30T BLOWER KIT (INCLUDES 31 THROUGH 38) BRASS BUSHING (4 REQUIRED) RUBBER GROMMET (4 REQUIRED) BLOWER PAN CORD SET ASSEMBLY BUSHING - HEYCO #SR5KN4 WIRE ASSEMBLY FAN CONTROL BLOWER (INCLUDES MOTOR, FAN, AND FAN HOUSING) BLOWER HARDWARE PACKAGE IGNITOR WIRE HARDWARE PACKAGE

35964-0-0615

USE ONLY MANUFACTURED REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

Page 17

PARTS VIEW
SR-10T

Page 18

35964-0-0615

PARTS VIEW
SR-18T

35964-0-0615

Page 19

PARTS VIEW
SR-30T

Page 20

35964-0-0615

OPTIONAL BLOWER INSTALLATION INSTRUCTIONS

SRB-18T and SRB-30T

for Unvented Room Heaters SR-18T and SR-30T

Installing Optional Blower SRB-18T or SRB-30T

12. With the heater standing upright, position the air discharge

If heater is installed onto the wall, in order to install the optional

opening of the blower housing downward. Place the bottom

blower, the heater must be removed from the wall. If heater is

flange of the blower housing over the top edge of the top heat

installed on optional floor stand there is adequate access area

shield. Insert the blower housing into the top portion of the

available to install the optional blower.

heater by pivoting the blower housing upward 90°. Attach

1. Turn "OFF" gas supply to the heater. 2. Remove lower louver from casing assembly (2 screws). 3. Remove reflector from casing assembly (2 screws). 4. Remove upper louver from casing assembly (2 screws). 5. Insert the fan control wires and the upper portion of the fan
control through the 3/4" (19mm) diameter hole on the bottom side of the top heat shield. The fan control wires will enter into the top portion of the heater and the fan control disc will be facing the ceramic plaques. Attach fan control to the bottom side of the top heat shield with (2) screws provided with the optional blower. 6. Route cord set through 9/16" (14mm) diameter hole on casing assembly back. Insert approximately 3" (76mm) of cord set into casing assembly back. 7. When you are facing the front of the heater, position the optional blower assembly onto the top heat shield of the heater. The motor wire harness should be facing into the top, right portion of the heater. 8. Attach (1) pin terminal from black (hot) wire, smooth insulation on cord set to (1) socket terminal on fan control wire harness. 9. Attach (1) pin terminal from black (neutral) wire, ribbed insulation on cord set to (1) socket terminal from white (neutral) wire on motor wire harness. 10. Attach (1) pin terminal on fan control wire harness to (1) socket terminal from black (hot) wire on motor wire harness. 11. Attach the green ground wire from the motor wire harness and the green ground wire from the cord set to the bottom right side of the blower housing with (1) screw provided with the optional blower.

the blower housing to the casing assembly with (4) screws provided with the optional blower. 13. Grasp cord set at casing assembly back and pull excess cord set through casing assembly back. Secure cord set in casing assembly back with the strain relief provided with the optional blower. 14. Installation of optional blower is completed. 15. If heater was removed from the wall, in order to install optional blower, check for gas leaks at all gas connections before lower louver is replaced onto casing assembly.
Attention! After optional blower has been installed use the following steps to properly align the upper louver and the reflector with the heat shield.
A. When replacing upper louver, be sure the bottom lip of upper louver goes behind the heat shield.
B. When replacing reflector, be sure the top lip of reflector goes in front of the heat shield.
Excessive Blower Wheel Noise Attention! If your blower assembly develops a squeal, hum or grinding noise, it indicates dirt or debris on shaft of blower wheel. Use the following steps to clean shaft of blower wheel.
1. Remove red rubber grommet with brass bushing or black rubber grommet with brass bushing from end of blower wheel shaft opposite motor.
2. Clean blower wheel shaft with cotton cloth. 3. Place 1 or 2 drops of all purpose oil on END of blower wheel
shaft. 4. Replace red rubber grommet with brass bushing or black rubber
grommet with brass bushing onto end of blower wheel shaft. Attention: The red rubber grommet with brass bushing or the black rubber grommet with brass bushing must "snap-back"

into position.

5. Cleaning of blower wheel shaft is completed.

CCOARSDINSGEBTAHCOKLE IN

HEAT SHIELD

35964-0-0615

FAN CONTROL

GROUND WIRE SCREW

RREEFMLOEVCETDORFRAONMD LCOAUSVINEGRSASASREEMBLY
SR-30T Shown

Page 21

OPTIONAL BLOWER INSTALLATION INSTRUCTIONS (continued)

Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. For an ungrounded receptacle, an adapter, which has two prongs and a wire for grounding, can be purchased, plugged into the ungrounded receptacle and its wire connected to the receptacle mounting screw. With this wire completing the ground, the appliance cord plug can be plugged into the adapter and be electrically grounded.
CAUTION
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
Blower Motor The blower motor does not have oiling holes. Do not attempt to oil the blower motor.
Blower Wheel The blower wheel will collect lint and could require periodic cleaning. If the air output decreases or the noise level increases, it indicates a dirty blower wheel.
To clean blower wheel: 1. Turn OFF gas supply to the heater. 2. Turn OFF electrical supply to the heater. 3. Remove lower louver from casing assembly (2 screws). 4. Remove reflector from casing assembly (2 screws). 5. Remove upper louver from casing assembly (2 screws). 6. Clean blower wheel with a vacuum cleaner. 7. As parts are being replaced in reverse order, check for gas leaks
at all gas connections before lower louver is replaced onto casing assembly.
WARNING
Unplugging of blower accessory will not stop the heater from cycling. To turn off gas to the unvented heater: Push in gas control knob slightly and turn clockwise to "OFF." Do not force.

If any of the original wire as supplied with the appliance must be replaced, it must be replaced with type 125°C wire or its equivalent.

Page 22

Index no. 1
2 3 4 5 6 6 7 8 NOT SHOWN

pARTS list Part No. Description R-2396 BLOWER (INCLUDES MOTOR, FAN, AND
FAN HOUSING) R-2503 FAN CONTROL R-2395 WIRE ASSEMBLY 8720161 BUSHING - HEYCO #SR5KN4 VF-068 CORD SET ASSEMBLY SR-196 BLOWER PAN (SR-18T) SR-198 BLOWER PAN (SR-30T) 8520141 RUBBER GROMMET (4 REQUIRED) 8520142 BRASS BUSHING (4 REQUIRED) SR-219 HARDWARE PACKAGE
35964-0-0615

MASTER PARTS DISTRIBUTOR LIST
To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort. com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the unit. To Order Parts After the Warranty Period, please contact your dealer or one of the Master Parts Distributors listed below. This list changes from time to time. For the current list, please click on the Master Parts button at www.empirecomfort.com. Please note: Master Parts Distributors are independent businesses that stock the most commonly ordered Original Equipment repair parts for Heaters, Grills, and Fireplaces manufactured by Empire Comfort Systems Inc.

Star-Fire Distributors 1355 Evans Avenue Akron, OH 44305
Phone: 330-630-2794 Toll Free: 800-875-6220 Fax: 330-633-8701 Parts: Heater & Hearth and Grills
East Coast Energy Products 10 East Route 36 West Long Branch, NJ 07764
Phone: 732-870-8809 Toll Free: 800-755-8809 Fax: 732-870-8811 Website: www.eastcoastenergy.com Parts: Heater & Hearth and Grills

Dey Distributing 1401 Willow Lake Boulevard Vadnais Heights, MN 55101
Phone: 651-490-9191 Toll Free: 800-397-1339 Website: www.deydistributing.com Parts: Heater & Hearth
Victor Division of F. W. Webb Company 200 Locust Street Hartford, CT 06114
Phone: 860-722-2433 Toll Free: 800-243-9360 Fax: 860-293-0479 Toll Free Fax: 800-274-2004 Websites: www.fwwebb.com & www.victormfg.com Parts: Heater & Hearth and Grills

HOW TO ORDER REPAIR PARTS

Parts Not Under Warranty
Parts can be ordered through your Service Person, Dealer, or a Master Parts Distributor. See this page for the Master Parts Distributors list. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer.
Warranty Parts
Warranty parts will need a proof of purchase and can be ordered by your Service Person or Dealer. Proof of purchase is required for warranty parts.
All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number and Serial Number from the name plate on your equipment. Then determine the Part Number (not the Index Number) and the Description of each part from the following illustration and part list. Be sure to give all this information . . .

Appliance Model Number

Part Description

Appliance Serial Number

Part Number

Type of Gas (Propane or Natural)

Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. Shipments contingent upon strikes, fires and all causes beyond our control.

35964-0-0615

Page 23

Page 24

EMPIRE
Comfort Systems

Empire Comfort Systems Inc. 918 Freeburg Ave. Belleville, IL 62220
If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer.

www.empirecomfort.com

35964-0-0615

